1.
Sensors (Basel) ; 24(2)2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38257648

RESUMO

To achieve optimal operation of the polarimetry-based FOCS, the light polarisation state at the input of the sensing fibre part must be close to a linear one. In the case of a FOCS deployed on a tokamak, the Joint European Torus (JET) in the present work, the long fibre optics link between the laser source and the sensing fibre modifies the polarisation in an unpredictable way, making it unclear which source polarisation state is to be set. A method for performing the necessary polarisation adjustment in a systematic way is proposed based on the FOCS analysis. The method requires performing data acquisition at two different input polarisations. Based on these measurements, the optimal laser source polarisation can be found. The method was experimentally verified using laboratory set-up and then successfully demonstrated with the FOCS installed at JET.

2.
Sensors (Basel) ; 23(3)2023 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-36772496

RESUMO

In this paper, we assess the effect of cryostat bridge vibrations on the plasma current measurement accuracy when using a fiber optic current sensor (FOCS) in ITER. The impact of vibrations on the light polarization state was first experimentally investigated using a miniaturized mock-up which represented a relevant part of the ITER FOCS structure. The set-up was then numerically simulated using the Jones matrix approach. Equivalent vibration matrices obtained from the experiment were used in the simulations to determine the effect of the vibrations on the FOCS accuracy. It is demonstrated that although the vibrations imply some changes in the polarization state, this effect can be strongly reduced when a proper low-birefringent spun optical fiber is used. The ITER requirement regarding the plasma current measurement accuracy can therefore be fulfilled.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA