Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Catheter Cardiovasc Interv ; 94(3): 334-341, 2019 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-30597737

RESUMO

BACKGROUND: The ION Study assessed clinical outcomes for the thin-strut, ION™ (TAXUS Element) Paclitaxel-Eluting Platinum Chromium Coronary Stent System (Boston Scientific, Marlborough, MA) in unselected patients. METHODS: This prospective, open-label registry enrolled the first 1,120 consenting patients treated with the ION stent without clinical or angiographic inclusion criteria at 40 clinical sites. Follow-up was at discharge, 30 days, 180 days, 1 and 2 years. The primary endpoint, the 1-year rate of cardiac death or MI (CD/MI) in PERSEUS-like patients (i.e., patients similar to those enrolled in PERSEUS, the pivotal approval trial), was tested in patients pooled from the ION study (N = 316), the European TAXUS Element post-approval registry (TE-PROVE; N = 306 PERSEUS-like patients), and the PERSEUS WH/SV populations (N = 1,166); and then compared with a prespecified performance goal. Additional outcomes were examined in the overall ION patient population. RESULTS: A total of 1,111 (out of 1,120) enrolled patients received a study stent. Most patients were male (70%) and mean age was 64 years. At 1 year, the primary endpoint of CD/MI occurred in 2.1% (6/292) of PERSEUS-like patients in ION, and 2.3% (40/1,729) of patients in the combined analysis. The upper one-sided 95% confidence interval for the combined analysis was 2.9%, which was significantly less than the performance goal of 7.6% (P < 0.001). Within patients enrolled in the ION study (N = 1,111), the rate of CD/MI was 4.5% at 1 year and 7.5% at 2 years. Definite/probable stent thrombosis occurred in 2.1% of patients at 1 year and 2.5% at 2 years. CONCLUSIONS: The results of the ION Study confirm the mid-term safety and effectiveness of the ION stent for the treatment of coronary artery disease in everyday clinical practice.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Cromo , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Paclitaxel/administração & dosagem , Platina , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Vigilância de Produtos Comercializados , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
2.
Catheter Cardiovasc Interv ; 94(1): 82-90, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30666784

RESUMO

OBJECTIVE: We evaluated 1-year outcomes after platinum chromium everolimus-eluting stents (PtCr-EES) in small versus non-small coronary arteries within a large, diverse sample of men, women, and minorities. BACKGROUND: There exists limited outcomes data on the use of second-generation drug-eluting stent to treat small diameter coronary arteries. METHODS: We pooled patients from the PLATINUM Diversity and PROMUS Element Plus stent registries. Small-vessel percutaneous coronary intervention (SV-PCI) was defined as ≥1 target lesion with reference vessel diameter (RVD) ≤2.5 mm. Endpoints included major adverse cardiac event (MACE; death, myocardial infarction [MI] or target vessel revascularization [TVR]), target vessel failure (TVF; death related to the target vessel, target vessel MI or TVR) and definite/probable stent thrombosis (ST). Multivariable Cox regression was used to risk-adjust outcomes. RESULTS: We included 4,155/4,182 (99%) patients with available RVD, of which 1,607 (39%) underwent small-vessel PCI. SV-PCI was not associated with increased MACE (adjHR 1.02; 95%CI 0.81-1.30) or TVF (adjHR 1.07; 95%CI 0.82-1.39). MI risk was lower in white men compared to women and minorities, both in the setting of SV-PCI (adjHR 0.41; 95%CI 0.23-0.74 and adjHR 0.39; 95%CI 0.20-0.75, respectively) and for non-SV-PCI (adjHR 0.61; 95%CI 0.38-0.99 and adjHR 0.45; 95%CI 0.27-0.74, respectively). There was no significant interaction between RVD and sex or minority status for any endpoint. CONCLUSION: In a large diverse contemporary PCI outcomes database, SV-PCI with PtCr-EES was not associated with increased MACE or TVR and did not account for the increased MI risk noted in women and minorities compared to white men.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Cromo , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Disparidades nos Níveis de Saúde , Saúde das Minorias , Intervenção Coronária Percutânea/instrumentação , Platina , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etnologia , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etnologia , Trombose Coronária/mortalidade , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etnologia , Infarto do Miocárdio/mortalidade , Estudos Observacionais como Assunto , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Fatores Raciais , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
3.
Circ J ; 83(7): 1489-1497, 2019 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-31155604

RESUMO

BACKGROUND: There are limited data on the long-term outcome of platinum chromium-based everolimus-eluting stents (PtCr-EES) vs. cobalt chromium-based zotarolimus-eluting stents (CoCr-ZES).Methods and Results:A total of 3,755 patients undergoing percutaneous coronary intervention (PCI) were randomized 2:1 to PtCr-EES or CoCr-ZES, and 96.0% of patients completed the 3-year clinical follow-up. The primary outcome was target lesion failure (TLF), defined as a composite of cardiac death, target vessel-related myocardial infarction (MI), and clinically-driven target lesion revascularization (TLR). At 3 years, TLF occurred in 5.3% and in 5.4% of the PtCr-EES and CoCr-ZES groups, respectively (hazard ratio 0.978; 95% confidence interval 0.730-1.310, P=0.919). There were no significant differences in the individual components of TLF. Routine angiographic follow-up was performed in 38.9% of the total patients. In a landmark analysis of the subgroup that had follow-up angiography, the clinically-driven TLR rate of CoCr-ZES was significantly higher than PtCr-EES group during the angiography follow-up period (P=0.009). Overall definite and probable stent thrombosis rates were very low in both groups (0.5% vs. 0.6%, P=0.677). CONCLUSIONS: PtCr-EES and CoCr-ZES had similar and excellent long-term outcomes in both efficacy and safety after PCI in an all-comer population.


Assuntos
Angiografia Coronária , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea , Sirolimo/análogos & derivados , Idoso , Cromo , Ligas de Cromo , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Platina , Estudos Prospectivos , Falha de Prótese , Sirolimo/administração & dosagem
4.
J Interv Cardiol ; 30(6): 550-557, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28940552

RESUMO

BACKGROUND: Prior reports have suggested that the design of the Promus Element stent is prone to longitudinal stent deformation (LSD). However, little is known about the clinical and angiographic outcomes of Promus Element stent axial deformations when implanted in unrestricted coronary lesions. METHOD AND RESULTS: Two independent reviewers retrospectively evaluated the procedure steps of 961 Promus Element stent (833 de novo lesions in 494 consecutive patients) implanted in unrestricted coronary lesions, between February 2012 and March 2013, and compared the prevalence, predictors, and the mid-term clinical and angiographic outcomes between lesions with and without stent deformation. Fifteen stents (1.56%) with LSD were observed (95% confidence interval [CI]: 0.78-2.34%). The proximal edge of the stent was deformed in 13 stents (86.6%). Ostial stenting (Adjusted Odds ratio [OR]: 9; 95%CI: 2.27-33.3; P = 0.002), and bifurcation lesions (Adjusted OR: 3; 95%CI: 1.03-8.8; P = 0.04) were independently associated with the occurrence of stent deformation. LSD led to unplanned stenting in (53%, 8 of 15) of the deformed stents, which consumed larger contrast volume and longer fluoroscopy time. At 8-month follow-up, there was no significant difference in binary restenosis rate and target lesions revascularization between both groups (P = 0.98, and P = 0.56, respectively), while death occurred in six patients of the non-LSD group (1.36%, 6 of 440) and none in the LSD group. All patients of the LSD group had no major adverse clinical events at 8-month follow-up. CONCLUSIONS: Axial stent deformation in Promus Element platform is an infrequent event, occurs following manipulation of the interventional tools. Other than unplanned stenting, the LSD was not associated with any adverse clinical events at 8-month follow-up.


Assuntos
Angiografia Coronária , Stents Farmacológicos/efeitos adversos , Intervenção Coronária Percutânea , Idoso , Doença da Artéria Coronariana/terapia , Reestenose Coronária/diagnóstico por imagem , Feminino , Humanos , Masculino , Estudos Retrospectivos
5.
Catheter Cardiovasc Interv ; 85 Suppl 1: 716-23, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25631909

RESUMO

OBJECTIVES: The PLATINUM China clinical trial evaluated the safety and effectiveness of the thin-strut, everolimus-eluting, platinum-chromium PROMUS™ Element™ stent (PtCr-EES) (Boston Scientific, Marlborough, MA) for the treatment of patients in China. BACKGROUND: Clinical outcomes from the PtCr-EES have not been evaluated in patients from China, nor has it been directly compared with the second-generation stainless steel paclitaxel-eluting TAXUS Liberté stent (PES) in a randomized head-to-head trial. Methods In this prospective, multicenter, single-blind, superiority trial, patients with a single de novo atherosclerotic coronary artery lesion were randomized 1:3 to receive either the PES or PtCr-EES. The primary endpoint was in-stent late loss at 9 months. RESULTS: Among 127 PES and 373 PtCr-EES patients (71.2% male; mean age 57.3 years), the primary endpoint of 9-month in-stent late loss was 0.40 ± 0.45 mm for PES versus 0.11 ± 0.36 mm for PtCr-EES (P < 0.001). In-stent % diameter stenosis was 22.20 ± 16.00% for PES versus 11.06 ± 13.86% for PtCr-EES (P < 0.001) at 9 months. The 1-year rate of death/MI was 1.6% (2/127) for PES versus 0% (0/371) for PtCr-EES (P = 0.06) and target vessel revascularization was 4.7% (6/127) for PES versus 2.7% (10/371) for PtCr-EES (P = 0.26). No stent thromboses occurred at 12 months in either group. CONCLUSIONS: In the largest prospective angiographic evaluation conducted to date with this stent, the PROMUS Element PtCr-EES was superior to the TAXUS Liberté PES for the primary endpoint of late loss at 9 months, with low rates of clinical events at 1 year. Clinical follow-up will continue to 2 years.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Cromo , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Platina , Adulto , Idoso , China , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/uso terapêutico , Estudos Prospectivos , Desenho de Prótese , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 86(6): 994-1001, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-25678402

RESUMO

BACKGROUND: The TAXUS Element (ION) platinum chromium paclitaxel-eluting stent (PtCr-PES) incorporates a thin (81 µm) strut design with a similar polymer and drug dose density as prior PES. The pivotal PERSEUS trial program consisted of two studies: PERSEUS Workhorse (WH) and PERSEUS Small Vessel (SV). The PERSEUS WH trial demonstrated the PtCr-PES to be non-inferior to the predicate TAXUS Express PES (TE-PES) for target lesion failure (TLF) at 1 year and in-segment angiographic percent diameter stenosis at 9 months. The PERSEUS SV trial demonstrated the PtCr-PES to be superior to a historical bare metal stent (BMS) for angiographic late lumen loss at 9 months. Long-term (5-year) clinical outcomes following PtCr-PES have not been previously reported. METHODS: PERSEUS WH was a prospective, Bayesian, 3:1 randomized (PtCr-PES vs. TE-PES) trial in patients with lesion length ≤28 mm and vessel diameter ≥2.75 to ≤4.0 mm. PERSEUS SV was a prospective, single-arm trial in patients with lesion length ≤20 mm and vessel diameter ≥2.25 to <2.75 mm comparing PtCr-PES to a matched historical BMS control. RESULTS: Among randomized subjects in the PERSEUS WH study, clinical event rates at 5 years were similar between treatment groups, including TLF (12.9% TE-PES vs. 12.1% PtCr-PES; P = 0.66). In the PERSEUS SV study, 5-year rates of MACE, and TLF were significantly lower for PtCr-PES (vs. BMS) following adjustment for baseline characteristics and were primarily due to lower target lesion revascularization rates (27.2% BMS vs. 14.9% PtCr-PES; P = 0.049). CONCLUSIONS: At 5 years, the PtCr-PES provides efficacy and safety that is comparable to the TE-PES and superior efficacy with similar safety when compared with BMS in smaller caliber vessels. Cumulative stent thrombosis rates remained low and similar through 5 years for both DES platforms.


Assuntos
Angioplastia Coronária com Balão/métodos , Doença das Coronárias/terapia , Stents Farmacológicos , Paclitaxel/administração & dosagem , Desenho de Prótese/métodos , Adulto , Idoso , Angioplastia Coronária com Balão/mortalidade , Teorema de Bayes , Cromo/química , Angiografia Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/mortalidade , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Platina/química , Estudos Prospectivos , Falha de Prótese , Medição de Risco , Índice de Gravidade de Doença , Método Simples-Cego , Estatísticas não Paramétricas , Taxa de Sobrevida , Taxus , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
7.
Expert Rev Med Devices ; 21(7): 601-611, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38720513

RESUMO

INTRODUCTION: The introduction of drug-eluting coronary stents (DES) into clinical practice in 2002 represented a major milestone in the treatment of obstructive coronary artery disease. Over the years, significant advances in polymer coating and in antiproliferative agent technology have further improved the safety and clinical performance of newer-generation DES. AREAS COVERED: Development of platinum chromium (PtCr) alloys with high radial strength and high radiopacity have enabled the design of new, thin-strut, flexible, and highly trackable stent platforms, while simultaneously improving stent visibility. These advances have facilitated complex percutaneous treatment of a diverse population of patients in clinical practice. This review will provide an overview of the evolution in PtCr everolimus-eluting stents from PROMUS Element™ to SYNERGY™ to the recently introduced SYNERGY MEGATRON™. The clinical data will be summarized and put into perspective, especially focusing on the role of the SYNERGY™ and MEGATRON™ platforms in the treatment of complex coronary artery disease and high-risk patients. EXPERT OPINION: The SYNERGY™ stent demonstrates favorable clinical efficacy and safety outcome data, and whilst the clinical data on MEGATRON™ are sparse, early experience is promising. The specific overexpansion capabilities, visibility, and radial strength of the MEGATRON™ are attractive features for complex coronary interventions.


Assuntos
Cromo , Doença da Artéria Coronariana , Stents Farmacológicos , Everolimo , Platina , Humanos , Doença da Artéria Coronariana/terapia , Everolimo/uso terapêutico , Everolimo/administração & dosagem , Platina/química
8.
JACC Asia ; 2(4): 446-456, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36339368

RESUMO

Background: Outcomes of percutaneous coronary intervention for diffuse long lesions remain relatively unfavorable. Prior clinical trials investigated the relative efficacy and safety of different types of drug-eluting stents (DES) in long lesions. Objectives: This study sought to compare the relative performance of different types of DES for de novo long (≥25 mm) coronary artery lesions. Methods: Using a pooled analysis of individual data of 1,450 patients from 3 randomized clinical trials, we compared angiographic and clinical outcomes of 5 different types of DES: 224 patients with cobalt-chromium everolimus-eluting stents (EES), 255 with platinum-chromium EES, 250 with Resolute zotarolimus-eluting stents, 245 with biodegradable polymer biolimus-eluting stents, and 476 with first-generation sirolimus-eluting stents (SES). The primary endpoint was in-segment late lumen loss at 9 months. Results: The primary endpoint was not significantly different between 4 second-generation DES and 1 first-generation SES (0.17 ± 0.41 mm in cobalt-chromium EES; 0.11 ± 0.37 in platinum-chromium EES: 0.14 ± 0.38 in Resolute zotarolimus-eluting stents; 0.14 ± 0.38 in biodegradable polymer biolimus-eluting stents; or 0.10 ± 0.37 in SES, respectively, overall P = 0.38). Also, there were no significant between-group differences with respect to death, myocardial infarction, target-vessel revascularization, or stent thrombosis at 12 months. In the multiple treatment propensity-score analysis, the risk of angiographic and clinical outcomes was also similar among several types of DES. Conclusions: In this patient-level pooled analysis, several second-generation DES showed similar angiographic and clinical outcomes in patients with de novo long coronary lesions. (Percutaneous Treatment of LONG Native Coronary Lesions With Drug-Eluting Stent-III [LONG-DES-III]; NCT01078038; Percutaneous Treatment of LONG Native Coronary Lesions With Drug-Eluting Stent-IV [LONG-DES-IV]; NCT01186094; and Everolimus-eluting [PROMUS-ELEMENT] vs. Biolimus A9-Eluting [NOBORI] Stents for Long-Coronary Lesions [LONG-DES-V]; NCT01186120).

9.
Int J Cardiol ; 240: 103-107, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28385356

RESUMO

BACKGROUND: A new-generation everolimus eluting platinum-chromium stent (EePCS), offering improved radial strength, radiopacity and conformability compared to everolimus-eluting cobalt-chromium stents (EeCCS), was evaluated with regard to safety and efficacy in an all-comer cohort. METHODS: A total of 1000 consecutive all-comer patients (including acute coronary syndrome, multivessel disease, calcified lesions) treated with an EePCS (Promus Premier™, Boston Scientific, Natick, Massachusetts) from May 2013 to October 2014 were compared to 1000 consecutive patients treated with an EeCCS (Xience Prime™, Abbott Vascular, Santa Clara, California) from April 2012 to May 2013. Patients were clinically followed for 1year. RESULTS: Mean age was 66±12years with diabetes in 20.7%, previous infarction in 22.7%, and ACS as the indication in 71.2% of patients. The mean number of stents per patient was 1.8±1.13. Total stented length was 35±25mm. Lesion classification was B2/C in 73.9% of patients. At 1year the primary endpoint of major adverse cardiac events (all-cause mortality, myocardial infarction [MI], ischemia-driven target vessel revascularization [TVR]) was reached in 11.7% in the EePCS cohort and 10.9% in the EeCCS cohort (adjusted HR 1.01 [0.77-1.33]; p=0.95). No significant differences were noted in the individual clinical endpoints all-cause mortality (6.8% versus 6.4%), MI (2.2% versus 2.3%), and TVR (4.3% versus 3.7%) in the respective EePCS and EeCCS cohorts. Stent thrombosis occurred in 0.8% and 1.0% respectively. CONCLUSIONS: In all-comer patients undergoing percutaneous coronary intervention, the use of EePCS was associated with similar 1-year clinical outcome as compared to EeCCS.


Assuntos
Cromo , Stents Farmacológicos/normas , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/normas , Platina , Sistema de Registros , Idoso , Angina Estável/mortalidade , Angina Estável/cirurgia , Estudos de Coortes , Stents Farmacológicos/tendências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/cirurgia , Países Baixos/epidemiologia , Intervenção Coronária Percutânea/tendências , Polímeros , Estudos Prospectivos
10.
Rev Esp Cardiol (Engl Ed) ; 69(12): 1152-1159, 2016 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-27595181

RESUMO

INTRODUCTION AND OBJECTIVES: In acute myocardial infarction (MI), novel highly deliverable drug-eluting stents (DES) may be particularly valuable as their flexible stent designs might reduce device-induced traumas to culprit lesions. The aim of the study was to assess the safety and efficacy of percutaneous coronary interventions with 2 novel durable polymer-coated DES in patients with acute MI. METHODS: The prospective, randomized DUTCH PEERS (TWENTE II) multicenter trial compares Resolute Integrity and Promus Element stents in 1811 all-comer patients, of whom 817 (45.1%) were treated for ST-segment elevation MI or non-ST-segment elevation MI and the 2-year outcome is available in 99.9%. The primary clinical endpoint is target vessel failure (TVF), a composite of cardiac death, target vessel related MI, or target vessel revascularization. RESULTS: Of all 817 patients treated for acute MI, 421 (51.5%) were treated with Resolute Integrity and 396 (48.5%) with Promus Element stents. At the 2-year follow-up, the rates of TVF (7.4% vs 6.1%; P = .45), target lesion revascularization (3.1% vs 2.8%; P = .79), and definite stent thrombosis (1.0% vs 0.5%; P = .69) were low for both stent groups. Consistent with these findings in all patients with acute MI, outcomes for the 2 DES were favorable and similar in both, with 370 patients with ST-segment elevation MI (TVF, 5.1% vs 4.9%; P = .81) and 447 patients with non-ST-segment elevation MI (TVF, 9.0% vs 7.5%; P = .56). CONCLUSIONS: Resolute Integrity and Promus Element stents were both safe and efficacious in treating patients with acute MI. The present 2-year follow-up data underline the safety of using these devices in this particular clinical setting.


Assuntos
Antineoplásicos , Stents Farmacológicos , Oclusão de Enxerto Vascular/epidemiologia , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Trombose/epidemiologia , Idoso , Doenças Cardiovasculares/mortalidade , Angiografia Coronária , Everolimo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Revascularização Miocárdica/estatística & dados numéricos , Países Baixos , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico por imagem , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Sirolimo/análogos & derivados
11.
Clin Res Cardiol ; 105(3): 206-15, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26329584

RESUMO

BACKGROUND: Percutaneous coronary intervention (PCI) in bifurcated lesions with second-generation drug-eluting stents (DES) was associated with increased myocardial infarction (MI) rates. Flexible stent designs that accommodate well to vessel tapering may be of benefit in challenging anatomies such as bifurcated target lesions, but so far data are scarce. METHODS: We analyzed the 2-year follow-up data of the DUTCH PEERS (TWENTE II) trial, which randomized 1811 all-comer patients to PCI with newer generation resolute integrity zotarolimus-eluting (Medtronic) or promus element everolimus-eluting stents (Boston Scientific). In bifurcated lesions, provisional stenting was generally performed. Target vessel failure is a composite endpoint, consisting of cardiac death, target vessel MI, or target vessel revascularization. RESULTS: Patients with at least one bifurcated lesion (n = 465, 25.7 %) versus patients with non-bifurcated target lesions only (n = 1346, 74.3 %) showed similar rates of clinical endpoints including target vessel failure (9.2 versus 7.9 %, p = 0.36) and definite stent thrombosis (0.4 versus 1.0 %, p = 0.38). Target vessel MI was more common in patients with bifurcated lesions (3.4 versus 1.6 %, p = 0.02); but after multivariate analysis with propensity score adjustment, bifurcation treatment was found not to be an independent predictor of target vessel MI (HR 1.40, 95 % CI 0.71-2.76; p = 0.34). Among patients with bifurcated lesions, DES type and side-branch size did not affect outcome, but periprocedural MI occurred more often after two-stent approaches (9.0 versus 2.1 %; p = 0.002). CONCLUSION: All-comer patients treated for bifurcated and non-bifurcated target lesions showed similar and low rates of clinical endpoints, suggesting that the DES used are efficacious and safe for treating bifurcated target lesions.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Modelos de Riscos Proporcionais , Desenho de Prótese , Fatores de Risco , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento
12.
JACC Cardiovasc Interv ; 8(9): 1180-1188, 2015 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-26210803

RESUMO

OBJECTIVES: This study sought to assess the incidence and clinical impact of stent fracture (SF) after the PROMUS Element platinum-chromium everolimus-eluting stent (PtCr-EES). BACKGROUND: SF remains an unresolved, clinically relevant issue, even in the newer-generation drug-eluting stent era. METHODS: From March 2012 to August 2013, 816 patients with 1,094 lesions were treated only with PtCr-EES and 700 patients (85.7%) with 898 lesions undergoing follow-up angiography within 9 months after the index procedure were analyzed. SF was defined as complete or partial separation of the stent, as assessed by plain fluoroscopy, intravascular ultrasound, or optical coherence tomography during the follow-up. We assessed the rate of SF and the cumulative incidence of clinically driven target lesion revascularization and definite stent thrombosis within 9 months after the index procedure. RESULTS: SF was observed in 16 of 898 lesions (1.7%) and 16 of 700 patients (2.2%). Lesions with in-stent restenosis at baseline (odds ratio [OR]: 14.2, 95% confidence intervals [CI]: 5.09 to 39.7; p < 0.001) or hinge motion (OR: 4.31, 95% CI: 1.12 to 16.5; p = 0.03), and total stent length (per 10-mm increase; OR: 1.32, 95% CI: 1.12 to 1.57; p = 0.001) were predictors of SF. Cumulative incidence of clinically driven target lesion revascularization within 9-months was numerically higher in the SF group than that in the non-SF group (18.7% vs. 2.3%). Cumulative incidence of definite stent thrombosis within 9 months after the index procedure was similar between the SF and non-SF groups (0.0% vs. 0.23%). CONCLUSIONS: SF after PtCr-EES occurs in 1.7% of lesions and appears to be associated with clinically driven target lesion revascularization.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Cromo , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Platina , Falha de Prótese , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Reestenose Coronária/diagnóstico , Reestenose Coronária/epidemiologia , Trombose Coronária/diagnóstico , Trombose Coronária/epidemiologia , Feminino , Humanos , Incidência , Japão/epidemiologia , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção
13.
Cardiovasc Revasc Med ; 16(2): 65-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25576273

RESUMO

BACKGROUND/PURPOSE: Bare metal stents (BMS) have similar rates of death and myocardial infarction (MI) compared to drug-eluting stents (DES). DES lower repeat revascularization rates compared to BMS, but may have higher rates of late stent thrombosis (ST) potentially due to impaired endothelialization requiring longer dual anti-platelet therapy (DAPT). OMEGA evaluated a novel BMS designed to have improved deliverability and radiopacity, in comparison to currently available platforms. METHODS/MATERIALS: OMEGA was a prospective, multicenter, single-arm study enrolling 328 patients at 37 sites (US and Europe). Patients received the OMEGA stent (bare platinum chromium element stent) for the treatment of de novo native coronary artery lesions (≤28 mm long; diameter ≥2.25 mm to ≤4.50mm). The primary endpoint was 9-month target lesion failure (TLF: cardiac death, target vessel-related MI, target lesion revascularization [TLR]) compared to a prespecified performance goal (PG) based on prior generation BMS. All major cardiac events were independently adjudicated. DAPT was required for a minimum of 1 month post procedure. RESULTS: In the OMEGA study, the mean age was 65; 17% had diabetes mellitus. The primary endpoint was met; 9 month TLF rate was 11.5%, and the upper 1-sided 95% confidence bound of 14.79% was less than the prespecified PG of 21.2% (p<0.0001). One-year event rates were low including a TLF rate of 12.8% and an ST rate of 0.6% at 12 months. CONCLUSIONS: One-year outcomes of OMEGA show low rates of TLF, revascularization and ST. This supports safety and efficacy of the OMEGA BMS for the treatment of coronary artery disease.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Estenose Coronária/terapia , Metais/uso terapêutico , Segurança do Paciente/estatística & dados numéricos , Stents , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/métodos , Angioplastia Coronária com Balão/mortalidade , Cromo/uso terapêutico , Angiografia Coronária/métodos , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/mortalidade , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Platina/uso terapêutico , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Índice de Gravidade de Doença , Método Simples-Cego , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
14.
JACC Cardiovasc Interv ; 8(7): 889-99, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26003019

RESUMO

OBJECTIVES: This study assessed clinical events and patient-reported chest pain 2 years after treatment of all-comers with Resolute Integrity zotarolimus-eluting stents (Medtronic Vascular, Santa Rosa, California) and Promus Element everolimus-eluting stents (Boston Scientific, Natick, Massachusetts). BACKGROUND: For both drug-eluting stents (DES), no all-comer outcome data from >12 months of follow-up have been published. Although there is increasing interest in patient-reported chest pain following stenting, data with novel DES are scarce. METHODS: The DUTCH PEERS multicenter trial (TWENTE II) (DUrable Polymer-Based STent CHallenge of Promus ElemEnt Versus ReSolute Integrity) Randomized Trial [TWENTE II]) randomized 1,811 all-comer patients to treatment with 1 type of DES. Monitoring and event adjudication were performed by independent contract research organizations. RESULTS: The 2-year follow-up of 1,810 patients (99.9%) was available. The primary composite endpoint target vessel failure occurred in 8.6% and 7.8% of patients treated with zotarolimus- and everolimus-eluting stents, respectively (p = 0.55). Rates of components of target vessel failure were: cardiac death (2.4% vs. 1.9%, p = 0.42); target vessel-related myocardial infarction (2.4% vs. 1.8%, p = 0.33); clinically-indicated target vessel revascularization (4.6% vs. 4.9%, p = 0.83). At 1- and 2-year follow-up, >80% of patients were free from chest pain (no between-stent difference). In addition, >87% of patients were either free from chest pain or experienced pain only at maximal physical exertion, but not during normal daily activities. Patients with chest pain after 12 months at no more than moderate physical effort had a higher risk of target vessel revascularization during the following year (hazard ratio: 1.89 [95% confidence interval: 1.05 to 3.39], p = 0.03). CONCLUSIONS: During the second year of follow-up, the incidence of adverse clinical endpoints remained similar and low for both DES. The vast majority of patients were free from chest pain.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Polímeros , Sirolimo/análogos & derivados , Idoso , Angina Pectoris/etiologia , Angina Pectoris/mortalidade , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Método Simples-Cego , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento
15.
J Am Coll Cardiol ; 63(4): 299-307, 2014 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-24211507

RESUMO

OBJECTIVES: This study sought to investigate the relative safety and efficacy of bioabsorbable polymer (BP)-based biolimus-eluting stents (BES) versus durable-polymer (DP)-drug-eluting stents (DES) and bare-metal stents (BMS) by means of a network meta-analysis. BACKGROUND: Studies have suggested that BP-BES might reduce the risk of stent thrombosis (ST) and late adverse outcomes compared with first-generation DES. However, the relative safety and efficacy of BP-BES versus newer-generation DES coated with more biocompatible DP have not been investigated in depth. METHODS: Randomized controlled trials comparing BP-BES versus currently U.S.-approved DES or BMS were searched through MEDLINE, EMBASE, and Cochrane databases. Information on study design, inclusion and exclusion criteria, sample characteristics, and clinical outcomes was extracted. RESULTS: Data from 89 trials including 85,490 patients were analyzed. At 1-year follow-up, BP-BES were associated with lower rates of cardiac death/myocardial infarction (MI), MI, and target vessel revascularization (TVR) than BMS and lower rates of TVR than fast-release zotarolimus-eluting stents. The BP-BES had similar rates of cardiac death/MI, MI, and TVR compared with other second-generation DP-DES but higher rates of 1-year ST than cobalt-chromium everolimus-eluting stents (CoCr-EES). The BP-BES were associated with improved late outcomes compared with BMS and paclitaxel-eluting stents, considering the latest follow-up data available, with nonsignificantly different outcomes compared with other DP-DES although higher rates of definite ST compared with CoCr-EES. CONCLUSIONS: In this large-scale network meta-analysis, BP-BES were associated with superior clinical outcomes compared with BMS and first-generation DES and similar rates of cardiac death/MI, MI, and TVR compared with second-generation DP-DES but higher rates of definite ST than CoCr-EES.


Assuntos
Materiais Revestidos Biocompatíveis , Trombose Coronária/epidemiologia , Stents Farmacológicos , Infarto do Miocárdio/epidemiologia , Revascularização Miocárdica/estatística & dados numéricos , Stents , Fármacos Cardiovasculares/administração & dosagem , Ligas de Cromo , Trombose Coronária/prevenção & controle , Everolimo , Humanos , Infarto do Miocárdio/terapia , Paclitaxel/administração & dosagem , Polímeros , Ensaios Clínicos Controlados Aleatórios como Assunto , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados
16.
J Am Coll Cardiol ; 62(21): 1915-1921, 2013 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-24036025

RESUMO

First-generation drug-eluting stents (DES), which impart the controlled release of sirolimus or paclitaxel from durable polymers to the vessel wall, have been consistently shown to reduce the risk of restenosis and target vessel revascularization compared with bare metal stents (BMS). However, stent thrombosis (ST) emerged as a major safety concern with first-generation DES early after their adoption in clinical practice, requiring prolonged dual antiplatelet therapy. Pathological studies have shown that first-generation DES are associated with delayed arterial healing and polymer hypersensitivity reactions resulting in chronic inflammation, predisposing to late and very late ST. Second-generation DES have been developed to overcome these issues with improved stent designs and construction and the use of biocompatible and bioabsorbable polymers. Meta-analyses have shown that the thin-strut, fluoropolymer-coated cobalt-chromium everolimus-eluting stent (CoCr-EES) may be associated with lower rates of definite ST than other DES and, unexpectedly, even lower than BMS. The thin-strut structure of the stent platform, the thromboresistant properties of the fluoropolymer, and the reduced polymer and drug load may contribute to the low rate of ST with CoCr-EES. The notion of DES being safer than BMS represents a paradigm shift in the evolution of percutaneous coronary intervention. The relative safety and efficacy of fluoropolymer-coated CoCr-EES, DES with bioabsorbable polymers, and fully bioresorbable scaffolds are the subject of numerous ongoing large-scale trials.


Assuntos
Reestenose Coronária/etiologia , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Complicações Pós-Operatórias , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA