Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.161
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Gastroenterology ; 164(7): 1108-1118.e3, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36907524

RESUMO

BACKGROUND & AIMS: For patients with achalasia experiencing persistent or recurrent symptoms after laparoscopic Heller myotomy (LHM), pneumatic dilation (PD) is the most frequently used treatment. Per-oral endoscopic myotomy (POEM) is increasingly being investigated as rescue therapy. This study aimed to determine the efficacy of POEM vs PD for patients with persistent or recurrent symptoms after LHM. METHODS: This randomized multicenter controlled trial included patients after LHM with an Eckardt score >3 and substantial stasis (≥2 cm) on timed barium esophagogram and randomized to POEM or PD. The primary outcome was treatment success, defined as an Eckardt score of ≤3 and without unscheduled re-treatment. Secondary outcomes included the presence of reflux esophagitis, high-resolution manometry, and timed barium esophagogram findings. Follow-up duration was 1 year after initial treatment. RESULTS: Ninety patients were included. POEM had a higher success rate (28 of 45 patients [62.2%]) than PD (12 of 45 patients [26.7%]; absolute difference, 35.6%; 95% CI, 16.4%-54.7%; P = .001; odds ratio, 0.22; 95% CI, 0.09-0.54; relative risk for success, 2.33; 95% CI, 1.37-3.99). Reflux esophagitis was not significantly different between POEM (12 of 35 [34.3%]) and PD (6 of 40 [15%]). Basal lower esophageal sphincter pressure and integrated relaxation pressure (IRP-4) were significantly lower in the POEM group (P = .034; P = .002). Barium column height after 2 and 5 minutes was significantly less in patients treated with POEM (P = .005; P = .015). CONCLUSIONS: Among patients with achalasia experiencing persistent or recurrent symptoms after LHM, POEM resulted in a significantly higher success rate than PD, with a numerically higher incidence of grade A-B reflux esophagitis. NETHERLANDS TRIAL REGISTRY: NL4361 (NTR4501), https://trialsearch.who.int/Trial2.aspx?TrialID = NTR4501.


Assuntos
Acalasia Esofágica , Esofagite Péptica , Miotomia de Heller , Cirurgia Endoscópica por Orifício Natural , Humanos , Acalasia Esofágica/diagnóstico , Acalasia Esofágica/cirurgia , Miotomia de Heller/efeitos adversos , Miotomia de Heller/métodos , Esfíncter Esofágico Inferior/cirurgia , Dilatação/efeitos adversos , Dilatação/métodos , Bário , Resultado do Tratamento , Esofagite Péptica/diagnóstico , Esofagite Péptica/etiologia , Esofagite Péptica/terapia , Cirurgia Endoscópica por Orifício Natural/efeitos adversos , Cirurgia Endoscópica por Orifício Natural/métodos
2.
Small ; : e2405493, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39087376

RESUMO

Simultaneous monitoring of critical parameters (e.g., pressure, shear, and temperature) at bony prominences is essential for the prevention of pressure injuries in a systematic manner. However, the development of wireless sensor array for accurate mapping of risk factors has been limited due to the challenges in the convergence of wireless technologies and wearable sensor arrays with a thin and small form factor. Herein, a battery-free, wireless, miniaturized multi-modal sensor array is introduced for continuous mapping of pressure, shear, and temperature at skin interfaces. The sensor array includes an integrated pressure and shear sensor consisting of 3D strain gauges and micromachined components. The mechanically decoupled design of the integrated sensor enables reliable data acquisition of pressure and shear at skin interfaces without the need for additional data processing. The sensor platform enables the analysis of interplay among localized pressure, shear, and temperature in response to changes in the patient's movement, posture, and bed inclination. The validation trials using a novel combination of wireless sensor arrays and customized pneumatic actuator demonstrate the efficacy of the platform in continuous monitoring and efficient redistribution of pressure and shear without repositioning, thereby improving the patient's quality of life.

3.
Clin Chem Lab Med ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38742247

RESUMO

OBJECTIVES: Efficient and timely transportation of clinical samples is pivotal to ensure accurate diagnoses and effective patient care. During the transportation process, preservation of sample integrity is crucial to avoid pre-analytical aberrations on laboratory results. Here, we present a comparative analysis between a two-step Tempus600 hub solution single-tube and a one-step, container-based pneumatic transport system (PTS) from Airco, for the in-house transportation of blood samples. METHODS: Ten blood samples from healthy volunteers were split in 10 mL collection tubes filled at full or half capacity for transportation with the two PTS (about 250 m). To compare the impact of transportation, markers of hemolysis such as lactate dehydrogenase (LDH), potassium (K+), and the hemolysis index (HI), were determined. Additionally, differences in HI in routine samples and repeated transportation was investigated. To assess and compare the mechanistic impact profiles, we recorded the acceleration profiles of the two PTS using a shock data logger. RESULTS: Transportation using the Tempus600 hub solution resulted in 49 and 46 % higher HI with samples filled to total or half capacity, respectively. Routine samples transported with the Tempus600 hub solution showed a higher median HI by 23 and 33 %. Additionally, shock logger analysis showed an elevated amount of shocks (6.5 fold) and shock intensities (1.8 fold). CONCLUSIONS: The Tempus600 hub solution caused an increased number of unreportable LDH or K+ results based on the hemolysis index. However, it was only statistically significant for LDH (p<0.01 and p<0.08) - while the comparisons for K+ were not statistically significant (p<0.28 and p<0.56).

4.
Clin Chem Lab Med ; 62(4): 657-663, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-37833063

RESUMO

OBJECTIVES: Many hospitals use pneumatic tube systems (PTS) for transport of diagnostic samples. Continuous monitoring of PTS and evaluation prior to clinical use is recommended. Data loggers with specifically developed algorithms have been suggested as an additional tool in PTS evaluation. We compared two different data loggers. METHODS: Transport types - courier, conventional (cPTS) and innovative PTS (iPTS) - were monitored using two data loggers (MSR145® logger, CiK Solutions GmbH, Karlsruhe, Germany, and a prototype developed at the University Medicine Greifswald). Data loggers differ in algorithm, recording frequencies and limit of acceleration detection. Samples from apparently healthy volunteers were split among the transport types and results for 37 laboratory measurands were compared. RESULTS: For each logger specific arbitrary units were calculated. Area-under-the-curve (AUC)-values (MSR145®) were lowest for courier and highest for iPTS and increased with increasing recording frequencies. Stress (St)-values (prototype logger) were obtained in kmsu (1,000*mechanical stress unit) and were highest for iPTS as well. Statistical differences between laboratory measurement results of transport types were observed for three measurands sensitive for hemolysis. CONCLUSIONS: The statistical, but not clinical, differences in the results for hemolysis sensitive measurands may be regarded as an early sign of preanalytical impairment. Both data loggers record this important interval of beginning mechanical stress with a high resolution indicating their potential to facilitate early detection of preanalytical impairment. Further studies should identify suitable recording frequencies. Currently, evaluation and monitoring of diagnostic sample transport should not only rely on data loggers but also include diagnostic samples.


Assuntos
Coleta de Amostras Sanguíneas , Hemólise , Humanos , Coleta de Amostras Sanguíneas/métodos , Estresse Mecânico , Alemanha
5.
Thromb J ; 22(1): 63, 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38997730

RESUMO

BACKGROUND: Deep vein thrombosis (DVT) is common in patients undergoing gynecological surgery. We aimed to investigate the preventive efficacy in DVT of graduated compression stockings (GCS) alone and in combination with intermittent pneumatic compression (GCS + IPC) after gynecological surgery. METHODS: In November 2022, studies on the use of GCS and GCS + IPC for the prevention of DVT after gynecological surgery were searched in seven databases. After literature screening and data extraction based on specific inclusion and exclusion criteria, preventive efficacies, including the risk of DVT and anticoagulation function, of GCS and GCS + IPC were compared. Finally, sensitivity analysis and Egger's test were performed to evaluate the stability of the meta-analysis. RESULTS: Six publications with moderate quality were included in this meta-analysis. The results showed that GCS + IPC significantly reduced DVT risk (P = 0.0002) and D-dimer levels (P = 0.0005) compared with GCS alone. Sensitivity analysis and Egger's test showed that the combined results of this study were stable and reliable. CONCLUSIONS: Compared with GCS alone, GCS + IPS showed a higher preventive efficacy against DVT in patients following gynecological surgery.

6.
BMC Ophthalmol ; 24(1): 287, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39014314

RESUMO

BACKGROUND: To report real-world outcomes of patients with primary Reghmatogenous Retinal Detachment (RRD) treated with Pneumatic Retinopexy (PnR) according to the indications of the Pneumatic Retinopexy versus Vitrectomy for management of Primary Rhegmatogenous Retinal Detachment Outcomes Randomized Trial (PIVOT) trial. METHODS: Multicenter, retrospective study. Patients treated with PnR for RRD between 2021 and 2023 and a follow-up of at least 6 months were included. Single-procedure anatomical success, final anatomical success, complications, causes of failures, best corrected visual acuity (BCVA) after surgery, and the vision-related quality of life using the 25-Item National Eye Institute Visual Function Questionnaire (NEI VFQ-25) were reported. RESULTS: A total of 76 eyes of 76 patients were included. Mean age was 60 ± 8.1 years. Primary anatomic reattachment was achieved by 84.3% of patients and final anatomical reattachment after pars plana vitrectomy was obtained in 100% of patients. BCVA improved from 0.32 (20/40) to 0.04 (20/20) logMar (p < 0.001) at 6 months. The main cause of failure was related to the presence of additional (likely missed) retinal breaks (66.6% of cases). Also, primary PnR failure was more frequent in eyes of patients with older age, macular involvement, worse baseline BCVA, greater extent of the RRD, and increased duration from diagnosis to treatment. Overall, the mean NEI-VFQ 25 composite score was 93.9% ± 6.4 at 6 months. CONCLUSIONS: The criteria of the PIVOT trial can be applied to real-world scenarios in the decision-making process for the treatment of primary RRD, with excellent anatomical and functional outcomes.


Assuntos
Qualidade de Vida , Descolamento Retiniano , Acuidade Visual , Vitrectomia , Humanos , Descolamento Retiniano/cirurgia , Descolamento Retiniano/fisiopatologia , Pessoa de Meia-Idade , Feminino , Masculino , Acuidade Visual/fisiologia , Estudos Retrospectivos , Idoso , Vitrectomia/métodos , Tamponamento Interno/métodos , Seguimentos , Resultado do Tratamento , Fluorocarbonos/administração & dosagem
7.
Eur J Appl Physiol ; 124(4): 1037-1048, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37792163

RESUMO

PURPOSE: Intermittent pneumatic compression (IPC) applies gradual pressure to facilitate lymph and blood flow movement to reduce exercise-induced tissue fluid accumulation and plasma volume loss. This study aimed to evaluate the cardiovascular system response during the recovery with IPC compared with passive recovery (Sham). METHODS: Sixteen volunteers (7 females and 9 males) executed a cycling-based exhausting sprint interval exercise (8 × 20 s all out), followed by a 30-min IPC or Sham condition. Participants performed two trials in a randomised, counterbalanced, and crossover design. Several cardiovascular parameters (blood pressure, heart function, and peripheral vascular resistance) were recorded at baseline (5'), through the recovery protocol (30'), and afterwards (5'). RESULTS: The use of IPC during the recovery phase led to a faster recovery, stated in relative values to pre-exercise, in mean blood pressure (102.5 ± 19.3% vs. 92.7 ± 12.5%; P < 0.001), and cardiac output (139.8 ± 30.0% vs. 146.2 ± 40.2%; P < 0.05) in comparison to Sham condition. Furthermore, during the IPC-based recovery, there was a slower recovery in cardiac pressure change over time (92.5 ± 25.8% vs. 100.5 ± 48.9%; P < 0.05), and a faster return to pre-exercise values in the peripheral vascular resistance (75.2 ± 25.5% vs. 64.8 ± 17.4%; P < 0.001) compared to Sham. CONCLUSION: The application of IPC after high-intensity exercise promotes the recovery of the cardiovascular system, reducing cardiovascular strain. Future investigations should consider the effects on the sympathetic-parasympathetic balance, such as heart rate variability, to assess further bonds between the use of IPC and autonomous control.


Assuntos
Sistema Cardiovascular , Dispositivos de Compressão Pneumática Intermitente , Feminino , Humanos , Masculino , Pressão Sanguínea , Exercício Físico/fisiologia , Hemodinâmica , Estudos Cross-Over
8.
Ophthalmologica ; : 1-9, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38723611

RESUMO

INTRODUCTION: This study aimed to investigate the incidence of and risk factors for epiretinal membrane (ERM) formation following primary rhegmatogenous retinal detachment (RRD) repair. METHODS: This comparative, retrospective, single-center cohort study included eyes with primary RRD treated between 2011 and 2023 at Massachusetts Eye and Ear, Boston, Massachusetts, with pars plana vitrectomy (PPV), scleral buckle (SB), PPV+SB, or pneumatic retinopexy (PnR). Demographic, clinical, and surgical parameters were collected from medical records. The primary outcome was the risk of ERM formation, while the secondary outcome was the risk of ERM requiring surgery. Univariable and multivariable Cox regression were performed, and a hazard ratio (HR) and 95% confidence interval (95% CI) were reported. RESULTS: Overall, 394 eyes were included. The mean age was 58.49 ± 12.8 years, and most patients were male. There was a significantly lower risk of ERM formation following SB compared to PPV in the univariable analysis (HR = 0.2, 95% CI = 0.08-0.60, p = 0.003); however, there was no significant association between treatment modality and ERM formation on multivariable Cox regression controlling for confounding factors (p = 0.24). ERM formation was found more commonly in patients who were older (HR = 1.0 per 1 year increase in age, 95% CI = 1.01-1.04, p = 0.001), those with worse baseline visual acuity (HR = 1.3, 95% CI = 1.09-1.71, p = 0.008), and those with macula-off RRDs (HR = 2.1, 95% CI = 1.41-3.32, p < 0.001). CONCLUSION: Surgical modality does not have a significant impact on the risk of ERM following retinal detachment repair. However, age, baseline visual acuity, and macular status are important predictors of ERM formation after RRD repair.

9.
Ophthalmologica ; 247(2): 118-132, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38408445

RESUMO

INTRODUCTION: The objective of this study was to compare the outcome of submacular hemorrhage (SMH) displacement using pneumatic displacement with intravitreal expansile gas versus pars plana vitrectomy (PPV) with subretinal injection of tissue plasminogen activator (tPA), anti-vascular endothelial growth factor (VEGF) agent, and air as primary surgery. METHODS: Retrospective interventional case series of 63 patients who underwent surgical displacement of SMH secondary to neovascular age-related macular degeneration (nAMD) or polypoidal choroidal vasculopathy (PCV) from May 1, 2015, to October 31, 2022. Medical records were reviewed for diagnosis, logMAR visual acuity (VA), central subfield thickness (CST), and postoperative displacement rates and complications up to 12 months after operation. RESULTS: The diagnosis was nAMD in 24 (38.1%) and PCV in 39 (61.9%) eyes. There were 40 (63.5%) eyes in the pneumatic displacement group (38 received C3F8, 2 received SF6) and 23 (36.5%) eyes in the subretinal cocktail injection. Mean baseline VA was 1.46 and 1.62, respectively (p = 0.404). The subretinal injection group had more extensive SMH (p = 0.005), thicker CST (1,006.6 µm vs. 780.2 µm, p = 0.012), and longer interval between symptom and operation (10.65 vs. 5.53 days, p < 0.001). The mean postoperative VA at 6 months was 0.67 and 0.91 (p = 0.180) for pneumatic displacement and subretinal injection groups, respectively, though VA was significantly better in the pneumatic group at 12-month visit (0.64 vs. 1.03, p = 0.040). At least 10 mean change in VA were >10 letters gain in both groups up to 12 months. Postoperative CST reduction was greater (625.1 µm vs. 326.5 µm, p = 0.008) and complete foveal displacement (87.0% vs. 37.5%), p < 0.001, odds ratio [OR] = 11.1) and displacement to arcade or beyond (52.5% vs. 17.5%, p = 0.009, OR = 5.15) were more frequent in the subretinal injection group. Two patients with failed pneumatic displacement were successfully treated with subretinal cocktail injection as a second operation. CONCLUSION: Surgical displacement of SMH leads to clinically meaningful improvement in VA. PPV with subretinal cocktail injection is more effective than pneumatic displacement in displacing SMH with similar safety profile despite longer interval before operation, higher CST, and more extensive SMH at baseline. Retinal surgeons could consider this novel technique in cases with thick and extensive SMH or as a rescue secondary operation in selected cases.


Assuntos
Tamponamento Interno , Angiofluoresceinografia , Hemorragia Retiniana , Ativador de Plasminogênio Tecidual , Tomografia de Coerência Óptica , Acuidade Visual , Vitrectomia , Humanos , Estudos Retrospectivos , Hemorragia Retiniana/diagnóstico , Hemorragia Retiniana/terapia , Hemorragia Retiniana/etiologia , Masculino , Feminino , Vitrectomia/métodos , Idoso , Tamponamento Interno/métodos , Ativador de Plasminogênio Tecidual/administração & dosagem , Tomografia de Coerência Óptica/métodos , Angiofluoresceinografia/métodos , Injeções Intravítreas , Inibidores da Angiogênese/administração & dosagem , Seguimentos , Resultado do Tratamento , Degeneração Macular Exsudativa/diagnóstico , Degeneração Macular Exsudativa/terapia , Degeneração Macular Exsudativa/complicações , Fundo de Olho , Fibrinolíticos/administração & dosagem , Fluorocarbonos/administração & dosagem , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Hexafluoreto de Enxofre/administração & dosagem
10.
Acta Neurochir (Wien) ; 166(1): 264, 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38874608

RESUMO

BACKGROUND: The management of perioperative venous thrombembolism (VTE) prophylaxis is highly variable between neurosurgical departments and general guidelines are missing. The main issue in debate are the dose and initiation time of pharmacologic VTE prevention to balance the risk of VTE-based morbidity and potentially life-threatening bleeding. Mechanical VTE prophylaxis with intermittend pneumatic compression (IPC), however, is established in only a few neurosurgical hospitals, and its efficacy has not yet been demonstrated. The objective of the present study was to analyze the risk of VTE before and after the implementation of IPC devices during elective neurosurgical procedures. METHODS: All elective surgeries performed at our neurosurgical department between 01/2018-08/2022 were investigated regarding the occurrence of VTE. The VTE risk and associated mortality were compared between groups: (1) only chemoprophylaxis (CHEMO; surgeries 01/2018-04/2020) and (2) IPC and chemoprophylaxis (IPC; surgeries 04/2020-08/2022). Furthermore, general patient and disease characteristics as well as duration of hospitalization were evaluated and compared to the VTE risk. RESULTS: VTE occurred after 38 elective procedures among > 12.000 surgeries. The number of VTEs significantly differed between groups with an incidence of 31/6663 (0.47%) in the CHEMO group and 7/6688 (0.1%) events in the IPC group. In both groups, patients with malignant brain tumors represented the largest proportion of patients, while VTEs in benign tumors occurred only in the CHEMO group. CONCLUSION: The use of combined mechanical and pharmacologic VTE prophylaxis can significantly reduce the risk of postoperative thromboembolism after neurosurgical procedures and, therefore, reduce mortality and morbidity.


Assuntos
Dispositivos de Compressão Pneumática Intermitente , Procedimentos Neurocirúrgicos , Tromboembolia Venosa , Humanos , Procedimentos Neurocirúrgicos/métodos , Procedimentos Neurocirúrgicos/efeitos adversos , Tromboembolia Venosa/prevenção & controle , Tromboembolia Venosa/etiologia , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Complicações Pós-Operatórias/prevenção & controle , Estudos Retrospectivos , Procedimentos Cirúrgicos Eletivos/métodos , Procedimentos Cirúrgicos Eletivos/efeitos adversos , Anticoagulantes/uso terapêutico , Anticoagulantes/administração & dosagem , Fatores de Risco
11.
Artigo em Inglês | MEDLINE | ID: mdl-39067663

RESUMO

BACKGROUND: Pneumatic tourniquets are frequently employed in extremity surgeries, aiming to enhance intraoperative visibility and minimize blood loss. While their benefits and drawbacks have been extensively studied in lower limb operations, their impact on upper limb procedures, particularly elbow surgery, remains poorly understood. This study investigates the advantages and risks associated with pneumatic tourniquet utilization in elbow surgery. METHODS: A retrospective analysis was conducted on 183 patients who underwent elbow surgery for fractures between January 2019 and September 2023. Patients were categorized into two groups: those who underwent surgery with a tourniquet (WT) and those without a tourniquet (NT). Subgroup analyses were performed based on fracture complexity. Data collected included patient characteristics, tourniquet usage, surgical duration, pre- and postoperative hemoglobin levels, C-reactive protein levels, pain assessments, opioid administration, hospital stay duration, follow-up, complications, and revisions. Statistical analyses were used to identify significant differences and correlations. RESULTS: The use of a tourniquet in elbow surgery yielded several notable outcomes. Patients in the WT group experienced significantly shorter surgical durations and hospital stays. Hemoglobin drop was lower in the WT group, indicating reduced blood loss. However, there were no significant differences in postoperative pain, opioid consumption, or complications between the WT and NT groups. Subgroup analysis revealed that the recorded differences, particularly shorter surgical durations, were more pronounced in complex fractures. CONCLUSIONS: This study shows promising results in the use of pneumatic tourniquets in elbow surgery in terms of enhanced efficiency, reduced blood loss, and overall safety, without compromising patient outcomes. However, the potential influence of perioperative decision-making on tourniquet usage underscores the need for further research to elucidate its role and optimize its application, especially in complex elbow fractures.

12.
Fetal Diagn Ther ; 51(1): 85-91, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37903468

RESUMO

INTRODUCTION: The aim of this study was to examine the efficacy of pneumatic compression of the maternal lower extremities in increasing the amniotic fluid index (AFI) in pregnancies complicated by isolated oligohydramnios. METHODS: Women with isolated oligohydramnios (AFI <5 cm) at 32-41 weeks of pregnancy were connected to a sequential compression device for 60 min. Prior and after the application, AFI and the pulsatility index (PI) of a number of arteries were measured. RESULTS: The median (interquartile range) maternal age of the 21 women included was 29 years (26.50-32.00), the median parity was 1 (1-2), and the median gestational age at intervention was 37.60 weeks (37.00-39.40). The median AFI increased after the application from 4.00 (3.62-4.50) to 6.08 cm (4.90-7.03) (p < 0.001). The median PI of the fetal renal artery decreased from 2.30 (2.01-2.88) to 2.26 (1.68-2.71) (p = 0.01). The hourly fetal urine production did not increase. Changes were not significant in the PI of the umbilical artery, the middle cerebral artery, and the bilateral uterine arteries. CONCLUSION: Short-term activation of pneumatic compression on maternal lower extremities could increase the AFI in women with isolated oligohydramnios.


Assuntos
Líquido Amniótico , Oligo-Hidrâmnio , Gravidez , Feminino , Humanos , Adulto , Lactente , Líquido Amniótico/fisiologia , Oligo-Hidrâmnio/diagnóstico por imagem , Sangue Fetal , Terceiro Trimestre da Gravidez , Artéria Renal , Perfusão
13.
Sensors (Basel) ; 24(8)2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38676157

RESUMO

This paper discusses a microfluidic system designed for surface plasmon resonance (SPR) sensing, incorporating integrated microvalves. This system is built from a layered structure of polydimethylsiloxane (PDMS) and polymethylmethacrylate (PMMA). The functionality of the microvalves is verified through a conductance method involving electrodes positioned at the microfluidic channels' inlets and outlets. These microvalves can fully close at a control pressure of 0.3 MPa, with their operation depending on the duration of the applied pressure. The study further explores the coordinated operation of multiple microvalves to regulate the sequential flow of samples and reagents in the system. In SPR detection experiments, the microfluidic system is integrated with an SPR array sensing system to control the injection of NaCl solutions via the microvalves, and the observation of phase change curves in different chip regions are observed. The findings validate the microvalves' dependability and suitability for use in SPR array sensing.

14.
Sensors (Basel) ; 24(6)2024 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-38544048

RESUMO

Machine condition monitoring is used in a variety of industries as a very efficient strategy for equipment maintenance. This paper presents a study on monitoring a pneumatic system using a feed-forward backpropagation neural network as a classifier and compares the results obtained with different sensor signals and associated extracted features as input for classification. The vibrations of the body of a pneumatic cylinder are acquired using both common industrial sensors and low-cost sensors integrated into an Arduino board. Pressure sensors for both chambers and a position sensor are also used. Power spectral density (PSD) is used to extract features from the acceleration signals, as well as statistical indices. Statistical indices are considered for pressure and position sensors. The results, which are based on experimental data obtained on a test bench, show that a feed-forward neural network makes it possible to identify the operating states with a good degree of reliability. Even with low-cost instrumentation, it is possible to realize reliable condition monitoring based on vibrations. This last result is particularly important as it can help to further increase the uptake of this maintenance approach in the industrial environment.

15.
Sensors (Basel) ; 24(11)2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38894193

RESUMO

The growing demand for agricultural output and limited resources encourage precision applications to generate higher-order output by utilizing minimal inputs of seed, fertilizer, land, and water. An electronically operated planter was developed, considering problems like ground-wheel skidding, field vibration, and the lack of ease in field adjustments of ground-wheel-driven seed-metering plates. The seed-metering plate of each unit of the developed planter is individually driven by a brushless direct current (BLDC) motor, and a BLDC motor-based aspirator is attached for pneumatic suction of seeds. The revolutions per minute (RPM) of the seed-metering plate are controlled by a microcontroller as per the received data relating to RPM from the ground wheel and the current RPM of the seed-metering plate. A feedback loop with proportional integral derivative (PID) control is responsible for reducing the error. Additionally, each row unit is attached to a parallelogram-based depth control system that can provide depth between 0 and 100 mm. The suction pressure in each unit is regulated as per seed type using the RPM control knob of an individual BLDC motor-based aspirator. The row-to-row spacing can be changed from 350 mm to any desired spacing. The cotton variety selected for the study was RCH 659, and the crucial parameters like orifice size, vacuum pressure, and forward speed were optimized in the laboratory with the adoption of a central composite rotatable design. An orifice diameter of 2.947 mm with vacuum pressure of 3.961 kPa and forward speed of 4.261 km/h was found optimal. A quality feed index of 93% with a precision index of 8.01% was observed from laboratory tests under optimized conditions. Quality feed index and precision index values of 88.8 and 12.75%, respectively, were obtained from field tests under optimized conditions.

16.
Sensors (Basel) ; 24(3)2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38339714

RESUMO

The industry is currently undergoing a digital revolution driven by the integration of several enabling technologies. These include automation, robotics, cloud computing, industrial cybersecurity, systems integration, digital twins, etc. Of particular note is the increasing use of digital twins, which offer significant added value by providing realistic and fully functional process simulations. This paper proposes an approach for developing digital twins in industrial environments. The novelty lies in not only focusing on obtaining the model of the industrial system and integrating virtual reality and/or augmented reality but also in emphasizing the importance of incorporating other enabled technologies of Industry 4.0, such as system integration, connectivity with standard and specific industrial protocols, cloud services, or new industrial automation systems, to enhance the capabilities of the digital twin. Furthermore, a proposal of the software tools that can be used to achieve this incorporation is made. Unity is chosen as the real-time 3D development tool for its cross-platform capability and streamlined industrial system modeling. The integration of augmented reality is facilitated by the Vuforia SDK. Node-RED is selected as the system integration option, and communications are carried out with MQTT protocol. Finally, cloud-based services are recommended for effective data storage and processing. Furthermore, this approach has been used to develop a digital twin of a robotic electro-pneumatic cell.

17.
Sensors (Basel) ; 24(5)2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38475180

RESUMO

In this study, an electric oil and gas actuator based on fractional-order PID position feedback control is proposed, through which the damping coefficient of the suspension system is adjusted to realize the active control of the suspension. An FOPID algorithm is used to control the motor's rotational angle to realize the damping adjustment of the suspension system. In this process, the road roughness is collected by the sensors as the criterion of damping adjustment, and the particle swarm algorithm is utilized to find the optimal objective function under different road surface slopes, to obtain the optimal cornering value. According to the mathematical and physical model of the suspension system, the simulation model and the corresponding test platform of this type of suspension system are built. The simulation and experimental results show that the simulation results of the fractional-order nonlinear suspension model are closer to the actual experimental values than those of the traditional linear suspension model, and the accuracy of each performance index is improved by more than 18.5%. The designed active suspension system optimizes the body acceleration, suspension dynamic deflection, and tire dynamic load to 89.8%, 56.7%, and 73.4% of the passive suspension, respectively. It is worth noting that, compared to traditional PID control circuits, the FOPID control circuit designed for motors has an improved control performance. This study provides an effective theoretical and empirical basis for the control and optimization of fractional-order nonlinear suspension systems.

18.
BMC Nurs ; 23(1): 558, 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39135011

RESUMO

INTRODUCTION: Venous thromboembolism (VTE), including deep venous thrombosis and pulmonary embolism, is a common and potentially fatal post-surgery complication. Research has shown that 50% of VTE causes are intraoperative, with the risk of occurrence highest during and immediately post-surgery. Therefore, strategies for early assessment and prevention should be established. OBJECTIVE: To identify optimal equipment selection, compression protocols, and strategies for complication prevention and management during intraoperative intermittent pneumatic compression (IPC), this study aims to synthesize the best available evidence. The objective is to inform accurate risk assessment and facilitate early mechanical prophylaxis against venous thrombosis. METHODS: The Practical Application to Clinical Evidence model proposed by the Joanna Briggs Institute was utilized. Indicators were identified using the available best evidence from January 2023 to October 2023, and a baseline review was conducted. Negative factors were identified based on clinical evidence-based practice. The implementation rates of different indicators before (n = 372) and after (n = 405) evidence-based practice, the incidence rates of intraoperative IPC-related adverse events and VTE, and the risk of venous thrombosis before (n = 50) and after (n = 50) practice were identified and compared. Furthermore, medical staff's knowledge of best practices for intraoperative IPC was assessed through pre- and post-intervention surveys involving 109 operating room personnel. RESULTS: All review indicators significantly improved (P < 0.01) after the evidence-based practice, and 9 reached 100%. Two intraoperative venous thrombosis events occurred before the evidence-based practice, with an incidence rate of 0.53%; no intraoperative venous thrombosis event occurred after the evidence-based practice, with no significant difference (X2 = 2.171, P = 0.141 > 0.05). However, there were significant differences in intraoperative venous blood hemodynamics before and after the practice (P < 0.05). Moreover, 9 IPC-related adverse events, including 4 cases of skin pressure, 3 cases of skin allergy, and 2 cases of lower limb circulation disorders, were reported before the evidence-based practice, with an incidence rate of 2.4%. Notably, no intraoperative IPC-associated adverse events occurred after the evidence-based practice(X2 = 9.913, P < 0.01). Meanwhile, the score of comprehension of the standard utilization of IPC for preventing venous thrombosis by medical staff in the operating room was 93.34 ± 3.64 after the evidence-based practice, which was higher than that (67.55 ± 5.45) before the evidence-based practice. Overall, the clinical practice was significantly improved the evidence-based practice. CONCLUSIONS: Applying intraoperative IPC utilization standards based on the best evidence in clinical practice effectively reduces the intraoperative IPC-associated adverse event rate and the risks of intraoperative venous thrombosis. It also improves the execution rates and compliance with mechanical prevention standards in the operating room by medical staff. Future research should prioritize the development and refinement of best clinical practices for intraoperative venous thrombosis prevention, with a particular emphasis on the integration of mechanical prophylaxis strategies.

19.
IEEE ASME Trans Mechatron ; 29(3): 1714-1725, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38895598

RESUMO

Magnetic resonance (MR) conditional actuators and encoders are the key components for MR-guided robotic systems. In this article, we present the modeling and control of our MR-safe pneumatic radial inflow motor and encoder. A comprehensive model is developed that considers the primary dynamic elements of the system, including: 1) motor dynamics, 2) pneumatic transmission line dynamics, and 3) valve dynamics. After model validation, we present a simplified third order model that facilitates design of a first order sliding mode controller (TO-SMC). Finally, the motor hardware is tested in a 7T MRI. No image distortion or artifacts were observed. We posit the MR-safe motor and dynamic model will lower the entry barriers for researchers interested in MR-guided robots and promote wider adoption of MR-guided robotic systems.

20.
Zhonghua Nan Ke Xue ; 30(2): 123-127, 2024 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-39177344

RESUMO

OBJECTIVE: To explore the clinical effect of sexual therapy combined with physical methods in the treatment of primary intravaginal anejaculation (PIAE) and its possible action mechanism. METHODS: Ninety PIAE patients with anxiety symptoms were equally randomized into three groups and treated by sexual therapy combined with vacuum negative pressure hydro pneumatic / pneumatic bubble massage (group A), sexual therapy (group B) or (vacuum negative pressure hydro pneumatic / pneumatic bubble massage (group C). After 15 cycles of treatment, the therapeutic effects were compared among the three groups of patients. RESULTS: The effectiveness rates in groups A, B and C were 86.67%, 46.67% and 30.00%, respectively, with statistically significant differences in the total effectiveness rate, the effective rate of the treatment of anxiety symptoms of the patients and their partners, and the effectiveness rate of the treatment of idiosyncratic masturbation (P<0.05). Pairwise comparison showed that the total effectiveness rate was dramatically higher in group A than in groups B and C (P<0.01), with no statistically significant difference between the latter two groups (P>0.05), that the effectiveness rate of the treatment of anxiety symptoms of the patients and sexual partners was remarkably higher in groups A and B than in C (P<0.01), with no statistically significant difference between the former two groups (P>0.05), and that the effectiveness rate of the treatment of idiosyncratic masturbation was significantly higher in group A than in B and C (P< 0.01), with no statistically significant difference between the latter two (P>0.05). CONCLUSION: PIAE is often accompanied by negative psychological state of the patients and their partners and idiosyncratic masturbation, which responds well to sexual therapy combined with vacuum negative pressure hydro pneumatic / pneumatic bubble massage.


Assuntos
Disfunções Sexuais Fisiológicas , Humanos , Feminino , Adulto , Adulto Jovem , Resultado do Tratamento , Pessoa de Meia-Idade , Disfunções Sexuais Fisiológicas/terapia , Massagem/métodos , Vagina , Ansiedade/terapia , Disfunção Ejaculatória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA