Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 215
Filtrar
1.
Bioinformatics ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38830086

RESUMO

MOTIVATION: Imaging Mueller polarimetry has already proved its potential for biomedicine, remote sensing and metrology. The real-time applications of this modality require both video rate image acquisition and fast data post-processing algorithms. First, one must check the physical realizability of the experimental Mueller matrices in order to filter out non-physical data, ie to test the positive semi-definiteness of the 4 × 4 Hermitian coherency matrix calculated from the elements of corresponding Mueller matrix pixel-wise. For this purpose, we compared the execution time for the calculations of i) eigenvalues, ii) Cholesky decomposition, iii) Sylvester's criterion, and iv) coefficients of the characteristic polynomial (two different approaches) of the Hermitian coherency matrix, all calculated for the experimental Mueller matrix images (600 pixels × 700 pixels) of mouse uterine cervix. The calculations were performed using C ++ and Julia programming languages. RESULTS: Our results showed the superiority of the algorithm iv) based on the simplification via Pauli matrices over other algorithms for our dataset. The sequential implementation of latter algorithm on a single core already satisfies the requirements of real-time polarimetric imaging. This can be further amplified by the proposed parallelization (e.g., we achieve a 5-fold speed up on 6 cores). AVAILABILITY AND IMPLEMENTATION: The source codes of the algorithms and experimental data are available at https://github.com/pogudingleb/mueller_matrices.

2.
Lasers Med Sci ; 39(1): 59, 2024 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-38336913

RESUMO

Tissue polarimetry has been gaining importance in extracting useful diagnostic information from the structural attributes of tissues, which vary in response to the tissue health status and hence find great potential in cancer diagnosis. However, the complexities associated with cancer make it challenging to isolate the characteristic changes as the tumor progresses using polarimetry. This study attempts to experimentally characterize the polarimetric behavior in colon cancer associated with various stages of development. Bulk and unstained sections of normal and tumor colon tissue were imaged in the reflection and transmission polarimetry configurations at low and high imaging resolutions using an in-house developed Mueller polarimeter. Through this study, we observed that the information about the major contributors of scattering in colon tissue, manifesting in depolarization and retardance, can be obtained from the bulk tissue and unstained sections. These parameters aid in characterizing the polarimetric changes as the colon tumor progresses. While the unstained colon section best indicated the depolarization contrast between normal and tumor, the contrast through the retardance parameter was more pronounced in the bulk colon tissue. The results suggest that the polarimetric "digitally stained" images obtained by Mueller polarimetry are comparable with the bulk tissue counterparts, making it useful for characterizing colon cancer tissues across different stages of development.


Assuntos
Neoplasias do Colo , Humanos , Neoplasias do Colo/diagnóstico por imagem , Neoplasias do Colo/patologia , Análise Espectral , Coloração e Rotulagem
3.
Sensors (Basel) ; 24(9)2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38732780

RESUMO

This contribution focuses on the detection of tracer particles within non-homogeneous bulk media, aiming to enhance insights into particulate systems. Polarimetric radar measurements are employed, utilizing cross-polarizing channels in order to mitigate interference from bulk media reflections. To distinguish the tracer particle in the measurements, a resonant cross-polarizing structure is constructed, facilitating the isolation of frequency signatures from the surrounding bulk clutter. In addition to characterizing the bulk and tracer components, this study provides a detailed presentation and discussion of the measurement setup, along with the employed signal processing methods. The effectiveness of the proposed methods is demonstrated through comprehensive measurements, where a tracer particle is systematically positioned at various locations. The results affirm the feasibility and efficacy of the approach, highlighting its applicability for enhanced dynamic monitoring in particulate systems within industrial processes.

4.
Sensors (Basel) ; 24(2)2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38257648

RESUMO

To achieve optimal operation of the polarimetry-based FOCS, the light polarisation state at the input of the sensing fibre part must be close to a linear one. In the case of a FOCS deployed on a tokamak, the Joint European Torus (JET) in the present work, the long fibre optics link between the laser source and the sensing fibre modifies the polarisation in an unpredictable way, making it unclear which source polarisation state is to be set. A method for performing the necessary polarisation adjustment in a systematic way is proposed based on the FOCS analysis. The method requires performing data acquisition at two different input polarisations. Based on these measurements, the optimal laser source polarisation can be found. The method was experimentally verified using laboratory set-up and then successfully demonstrated with the FOCS installed at JET.

5.
Sensors (Basel) ; 24(13)2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-39001044

RESUMO

The generation of terahertz radiation via laser-induced plasma from two-color femtosecond pulses in air has been extensively studied due to its broad emission spectrum and significant pulse energy. However, precise control over the temporal properties of these ultra-broadband terahertz pulses, as well as the measurement of their polarization state, remain challenging. In this study, we review our latest findings on these topics and present additional results not previously reported in our earlier works. First, we investigate the impact of chirping on the fundamental wave and the effect of manipulating the phase difference between the fundamental wave and the second-harmonic wave on the properties of generated terahertz pulses. We demonstrate that we can tune the time shape of terahertz pulses, causing them to reverse polarity or become bipolar by carefully selecting the correct combination of chirp and phase. Additionally, we introduce a novel technique for polarization characterization, termed terahertz unipolar polarimetry, which utilizes a weak probe beam and avoids the systematic errors associated with traditional methods. This technique is effective for detecting polarization-structured terahertz beams and the longitudinal component of focused terahertz beams. Our findings contribute to the improved control and characterization of terahertz radiation, enhancing its application in fields such as nonlinear optics, spectroscopy, and microscopy.

6.
Nano Lett ; 23(23): 10991-10997, 2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-38018700

RESUMO

Imaging polarimeters find many critical applications in applications ranging from remote sensing to biological detection. Metasurfaces have been proposed as a compact approach for imaging polarimeters, but prior strategies suffer from low imaging resolution. Here, we propose an interleaved metalens configuration for polarization imaging where three-row metasurface units within a group individually interact with three pairs of orthogonal polarization channels. The optical paths between the object and adjacent three-row metasurfaces are nearly equal, allowing the construction of a metalens polarimeter with an unlimited numerical aperture (NA), which is beneficial for high-resolution polarization imaging. The metalens polarimeter fabricated by crystalline silicon nanostructures has a NA of 0.51 at 632.8 nm and achieves an imaging resolution of up to a 1.2-fold wavelength. Polarimetric microscopy experiments demonstrate that metalens polarimeters can realize high-resolution polarization imaging for various microscopic samples. This study offers a promising solution for high-resolution metasurface polarization imaging, with the potential for widespread applications.

7.
Nano Lett ; 23(16): 7419-7426, 2023 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-37539988

RESUMO

Multifarious molecular ferroelectrics with multipolar axial characteristics have emerged in recent years, enriching the scenarios for energy harvesting, sensing, and information processing. The increased polar axes have enhanced the urgency of distinguishing different polarization states in material design, mechanism exploration, etc. However, conventional methods hardly meet the requirements of in situ, fast, microscale, contactless, and nondestructive features due to their inherent limitations. Herein, SHG polarimetry is introduced to probe the multioriented polarizations on a nanosized multiaxial molecular ferroelectric, i.e., TMCM-CdCl3 nanoplates, as an example. Combined with the analysis of the second-order susceptibility tensor, SHG polarimetry could serve as an effective method to detect the polarization orders and domain distributions of molecular ferroelectrics. Profiting from the full-optical feature, SHG polarimetry can even be performed on samples covered by transparent mediums, 2D materials, or thin metal electrodes. Our research might spark further fundamental studies and expand the application boundaries of next-generation ferroelectric materials.

8.
Chirality ; 35(10): 700-707, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37088812

RESUMO

This work presents a novel approach for investigating symmetry-breaking processes during crystallization using Mueller matrix polarimetry. By applying this method to the cooling process of NaClO3 solutions, we demonstrate its ability to capture not only the initial and final stages of crystallization but also the intermediate steps and dynamics of the process. This technique provides more comprehensive information and insights into the symmetry-breaking mechanisms involved in crystal formation. Overall, this study highlights the potential of Mueller matrix polarimetry for in situ statistical measurements of the optical rotation and for monitoring the evolution of enantiomeric excesses.

9.
J Quant Spectrosc Radiat Transf ; 302: 108567, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36945203

RESUMO

Objective: To conduct a proof-of-concept study of the detection of two synthetic models of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) using polarimetric imaging. Approach: Two SARS-CoV-2 models were prepared as engineered lentiviruses pseudotyped with the G protein of the vesicular stomatitis virus, and with the characteristic Spike protein of SARS-CoV-2. Samples were prepared in two biofluids (saline solution and artificial saliva), in four concentrations, and deposited as 5-µL droplets on a supporting plate. The angles of maximal degree of linear polarization (DLP) of light diffusely scattered from dry residues were determined using Mueller polarimetry from87 samples at 405 nm and 514 nm. A polarimetric camera was used for imaging several samples under 380-420 nm illumination at angles similar to those of maximal DLP. Per-pixel image analysis included quantification and combination of polarization feature descriptors in 475 samples. Main results: The angles (from sample surface) of maximal DLP were 3° for 405 nm and 6° for 514 nm. Similar viral particles that differed only in the characteristic spike protein of the SARS-CoV-2, their corresponding negative controls, fluids, and the sample holder were discerned at 10-degree and 15-degree configurations. Significance: Polarimetric imaging in the visible spectrum may help improve fast, non-contact detection and identification of viral particles, and/or other microbes such as tuberculosis, in multiple dry fluid samples simultaneously, particularly when combined with other imaging modalities. Further analysis including realistic concentrations of real SARS-CoV-2 viral particles in relevant human fluids is required. Polarimetric imaging under visible light may contribute to a fast, cost-effective screening of SARS-CoV-2 and other pathogens when combined with other imaging modalities.

10.
J Med Internet Res ; 25: e42723, 2023 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-37115612

RESUMO

BACKGROUND: Scientific research is typically performed by expert individuals or groups who investigate potential solutions in a sequential manner. Given the current worldwide exponential increase in technical innovations, potential solutions for any new problem might already exist, even though they were developed to solve a different problem. Therefore, in crowdsourcing ideation, a research question is explained to a much larger group of individuals beyond the specialist community to obtain a multitude of diverse, outside-the-box solutions. These are then assessed in parallel by a group of experts for their capacity to solve the new problem. The 2 key problems in brain tumor surgery are the difficulty of discerning the exact border between a tumor and the surrounding brain, and the difficulty of identifying the function of a specific area of the brain. Both problems could be solved by a method that visualizes the highly organized fiber tracts within the brain; the absence of fibers would reveal the tumor, whereas the spatial orientation of the tracts would reveal the area's function. To raise awareness about our challenge of developing a means of intraoperative, real-time, noninvasive identification of fiber tracts and tumor borders to improve neurosurgical oncology, we turned to the crowd with a crowdsourcing ideation challenge. OBJECTIVE: Our objective was to evaluate the feasibility of a crowdsourcing ideation campaign for finding novel solutions to challenges in neuroscience. The purpose of this paper is to introduce our chosen crowdsourcing method and discuss it in the context of the current literature. METHODS: We ran a prize-based crowdsourcing ideation competition called HORAO on the commercial platform HeroX. Prize money previously collected through a crowdfunding campaign was offered as an incentive. Using a multistage approach, an expert jury first selected promising technical solutions based on broad, predefined criteria, coached the respective solvers in the second stage, and finally selected the winners in a conference setting. We performed a postchallenge web-based survey among the solvers crowd to find out about their backgrounds and demographics. RESULTS: Our web-based campaign reached more than 20,000 people (views). We received 45 proposals from 32 individuals and 7 teams, working in 26 countries on 4 continents. The postchallenge survey revealed that most of the submissions came from single solvers or teams working in engineering or the natural sciences, with additional submissions from other nonmedical fields. We engaged in further exchanges with 3 out of the 5 finalists and finally initiated a successful scientific collaboration with the winner of the challenge. CONCLUSIONS: This open innovation competition is the first of its kind in medical technology research. A prize-based crowdsourcing ideation campaign is a promising strategy for raising awareness about a specific problem, finding innovative solutions, and establishing new scientific collaborations beyond strictly disciplinary domains.


Assuntos
Crowdsourcing , Neoplasias , Neurocirurgia , Humanos , Pesquisa Biomédica , Crowdsourcing/métodos , Neurocirurgia/tendências , Tecnologia
11.
Lasers Med Sci ; 38(1): 46, 2023 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-36662327

RESUMO

The cervix is composed of layers of squamous epithelium and connective tissue. The main component of the cervical connective tissue is collagen, which has specific orientations in different parts of the cervix and provides mechanical strength. Cervical pathologies such as cervical intraepithelial neoplasia (CIN), cancer, pregnancy, and spontaneous preterm birth (sPTB) allow for structural remodeling of both squamous epithelium and connective tissue. Mueller matrix (MM) polarimetry is an optical imaging technique that uses polarized light to characterize the morphologic changes in pathological cervix. In this study, advances in MM polarimetry in characterizing cervical tissue and associated pathologies were reviewed. In particular, the basic structure of the MM polarimeter is described. The interaction of polarized light with cervical tissue in terms of polarimetric parameters such as depolarization and birefringence is discussed. The assessment of cervical pathologies including CIN, cancer, pregnancy, and sPTB with MM polarimetry and the underlying reasons that produce the contrast in optical imaging are outlined. The clinical implementation of MM polarimetry, especially the Müller polarimetry colposcope, is also discussed. Finally, the challenges for MM polarimetry in cervical clinics are also speculated.


Assuntos
Carcinoma de Células Escamosas , Nascimento Prematuro , Displasia do Colo do Útero , Recém-Nascido , Feminino , Gravidez , Humanos , Colo do Útero/diagnóstico por imagem , Análise Espectral , Imagem Óptica/métodos
12.
Lasers Med Sci ; 38(1): 35, 2023 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-36622455

RESUMO

Understanding the virology of the coronavirus at the structural level has gained utmost importance to overcome the constant and long-term health complications induced by them. In this work, the light scattering properties of SARS-CoV-2 of size 140 nm were simulated by using discrete dipole approximation (DDA) for two incident wavelengths 200 nm and 350 nm, respectively. Three different 3-dimensional (3D) models of SARS-CoV-2 corresponding to 15, 20, and 40 numbers of spike proteins on the viral capsid surface were constructed as target geometries for the DDA calculations. These models were assessed by employing Stokes-Mueller polarimetry to obtain individual polarization properties such as degree of polarization (DOP), degree of linear polarization (DOLP), and degree of circular polarization (DOCP). Irrespective of its spike numbers, all the coronavirus models were found to display higher DOP and DOCP values and negligibly small DOLP values for circularly polarized incident light, indicating the presence of chiral structures. On the other hand, the lack of understanding about the dependence of the Mueller matrix on its microstructural properties was overcome by transforming 16 Mueller elements into sub-matrices with specific structural and physical properties using Lu-Chipman-based Mueller matrix polar decomposition method. The obtained properties such as retardance, diattenuation, and depolarization were used for investigating the composition and microstructural information. The approach presented in this work has the potential to understand the virology of the coronavirus at the structural level and, therefore, will be beneficial in developing effective detection strategies by exploiting their characteristic electromagnetic scattering signatures.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Análise Espectral , Refração Ocular
13.
Sensors (Basel) ; 23(3)2023 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-36772496

RESUMO

In this paper, we assess the effect of cryostat bridge vibrations on the plasma current measurement accuracy when using a fiber optic current sensor (FOCS) in ITER. The impact of vibrations on the light polarization state was first experimentally investigated using a miniaturized mock-up which represented a relevant part of the ITER FOCS structure. The set-up was then numerically simulated using the Jones matrix approach. Equivalent vibration matrices obtained from the experiment were used in the simulations to determine the effect of the vibrations on the FOCS accuracy. It is demonstrated that although the vibrations imply some changes in the polarization state, this effect can be strongly reduced when a proper low-birefringent spun optical fiber is used. The ITER requirement regarding the plasma current measurement accuracy can therefore be fulfilled.

14.
Sensors (Basel) ; 23(23)2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-38067679

RESUMO

We report on a study of the temperature dependence of the response of a BSO crystal based polarimetric current sensor with spectral interrogation. Two possible interrogation schemes are discussed. The spectral dependence of the optical rotation along the crystal caused by temperature and current changes is investigated, and approximate dependences for the sensitivities to current SI and temperature ST are derived. A mixed term in the response with spectral interrogation is revealed, the elimination of which is achieved by tracking wavelength shifts Δλ1 and Δλ2 of two distinct extrema in the polarimetric response. A temperature independent second degree equation for the current changes ΔI as a function of the measured spectral shifts is derived and tested.

15.
Sensors (Basel) ; 23(7)2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-37050673

RESUMO

This article deals with the analysis of backscattering at automatic target recognition (ATR) by ground-based radar located on rough terrain surfaces, using the properties of wave polarization. The purpose of the study is to examine and compare linear and circular polarized reflected waves, which can be described by decomposition theorems. Coherent decompositions (Pauli, Krogager, Cameron decomposition) are considered in the case of a rough terrain, for which the advantage of the Pauli decomposition has been shown. The article demonstrates an approach to the extraction of polarization signal backscattering data for two types of vehicles with different profiles. It is shown that the measurement results can be calibrated by a corner reflector that takes into account the properties of the ground surface, and further used for ATR based on supervised learning algorithms. The accuracy of object classification was 68.1% and 54.2% for the signal generated by linearly and elliptically polarized waves, respectively. Based on these results, we recommend using a linearly polarized wave as an object recognition mechanism. At the same time, any reflected depolarized wave significantly reshapes the structure due to the rotation of the object profile and the influence of a rough surface (vegetation fluctuations). This explains the low recognition accuracy in general.

16.
Int J Mol Sci ; 24(4)2023 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-36835613

RESUMO

The characterization and evaluation of skin tissue structures are crucial for dermatological applications. Recently, Mueller matrix polarimetry and second harmonic generation microscopy have been widely used in skin tissue imaging due to their unique advantages. However, the features of layered skin tissue structures are too complicated to use a single imaging modality for achieving a comprehensive evaluation. In this study, we propose a dual-modality imaging method combining Mueller matrix polarimetry and second harmonic generation microscopy for quantitative characterization of skin tissue structures. It is demonstrated that the dual-modality method can well divide the mouse tail skin tissue specimens' images into three layers of stratum corneum, epidermis, and dermis. Then, to quantitatively analyze the structural features of different skin layers, the gray level co-occurrence matrix is adopted to provide various evaluating parameters after the image segmentations. Finally, to quantitatively measure the structural differences between damaged and normal skin areas, an index named Q-Health is defined based on cosine similarity and the gray-level co-occurrence matrix parameters of imaging results. The experiments confirm the effectiveness of the dual-modality imaging parameters for skin tissue structure discrimination and assessment. It shows the potential of the proposed method for dermatological practices and lays the foundation for further, in-depth evaluation of the health status of human skin.


Assuntos
Colágeno , Microscopia de Geração do Segundo Harmônico , Humanos , Animais , Camundongos , Colágeno/química , Pele , Diagnóstico por Imagem , Análise Espectral
17.
Molecules ; 28(4)2023 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-36838510

RESUMO

Cyanine dyes are known to form H- and J-aggregates in aqueous solutions. Here we show that the cyanine dye, S0271, assembles in water into vortex induced chiral J-aggregates. The chirality of the J-aggregates depends on the directionality of the vortex. This study utilised both conventional benchtop CD spectropolarimeters and Mueller matrix polarimetry. It was found that J-aggregates have real chirality alongside linear dichroism and linear and circular birefringence. We identify the factors that are key to the formation of metastable chiral J-aggregates and propose a mechanism for their assembly.


Assuntos
Corantes , Água , Carbocianinas , Dicroísmo Circular
18.
Angew Chem Int Ed Engl ; 62(6): e202212724, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36426601

RESUMO

We show that chiral Frenkel excitons yield intense circularly polarized luminescence with an intrinsic dissymmetry factor in emission glum as high as 0.08. This outstanding value is measured through thin films of cyanine J-aggregates that form twisted bundles. Our measurements, obtained by a Mueller polarization analysis, are artifact-free and reveal a quasi-perfect correlation between the dissymmetry factors in absorption, gabs , and in emission glum . We interpret the bisignate dissymmetry factors as the signature of a strong coupling between chiral Frenkel excitons longitudinally excited along the bundles. We further resolve by polarimetry analysis the split in energy between the excited states with a Davydov splitting as small as 28 meV. We finally show the anti-Kasha nature of the chiral emission bands with opposite optical chirality. These mirror-imaged emissive chiroptical features emerge from the structural rigidity of the bundles that preserves the ground- and excited-state chirality.

19.
J Synchrotron Radiat ; 29(Pt 4): 969-977, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35787562

RESUMO

We report on the characterization of a novel extreme-ultraviolet polarimeter based on conical mirrors to simultaneously detect all the components of the electric field vector for extreme-ultraviolet radiation in the 45-90 eV energy range. The device has been characterized using a variable polarization source at the Elettra synchrotron, showing good performance in the ability to determine the radiation polarization. Furthermore, as a possible application of the device, Faraday spectroscopy and time-resolved experiments have been performed at the Fe M2,3-edge on an FeGd ferrimagnetic thin film using the FERMI free-electron laser source. The instrument is shown to be able to detect the small angular variation induced by an optical external stimulus on the polarization state of the light after interaction with magnetic thin film, making the device an appealing tool for magnetization dynamics research.

20.
Chirality ; 34(8): 1151-1161, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35656848

RESUMO

Optically active linear polyimides and hyperbranched poly (amic acid-imide) were prepared by using procedures varying in particular in the maximum temperature employed in their synthesis. The two types of linear polyimides were based on 4,4'-(hexafluoroisopropylidene)diphthalic anhydride and 1,2-diaminocylohexane enantiomers or 4,4'-(hexafluoroisopropylidene)diphthalic anhydride and 2,2'-diamino-1,1'-binaphthalene enantiomers. The amine-terminated hyperbranched poly (amic acid-imide) was prepared from 4,4'-(hexafluoroisopropylidene)diphthalic anhydride and 4,4',4″-triaminotriphenylmethane, and its end groups were modified with the chiral selectors N-acetyl-D-phenylalanine or N-acetyl-L-phenylalanine. The final structure of the products was analyzed by IR spectroscopy, and their optical activity was evaluated and confirmed by polarimetry or circular dichroism.


Assuntos
Anidridos , Imidas , Anidridos/química , Dicroísmo Circular , Imidas/química , Estereoisomerismo , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA