RESUMO
PURPOSE: Ocular ischemic syndrome can be the first and only hint of life-threatening carotid artery disease. The early recognition of carotid stenosis-related retinal signs, as well as the comprehension of the pathophysiology behind retinal changes could become relevant for physicians to predict the risk of stroke. The aim of this study is to assess the carotid artery disease-induced early structural retinochoroidal changes by means of swept-source optical coherence tomography (SS-OCT). METHODS: A prospective observational study was conducted in 72 eyes with carotid stenosis. According to the degree of stenosis, the participants were divided into a normal group (34 eyes), a mild-moderate stenosis group (22 eyes), a severe stenosis group (16 eyes). SS-OCT and OCTA were performed to scan macular fovea. Central macular thickness (CMT), subfoveal choroidal thickness (SCT) and foveal avascular zona (FAZ) area were the major measurements for our study. RESULTS: CMT was significantly thicker in group 3 when compared to group 2 and 1. SCT was significantly thinner in group 3 vs group 1, being thicker in group 2 when compared to group 1. No significant differences were obtained when comparing FAZ in the superficial and middle capillary plexus although it was significant when comparing the FAZ in the deep capillary plexus between group 1 and 3. CONCLUSION: internal carotid artery stenosis greater than 70% leads to a significant increase in CMT and a decrease in SCT prior the development of clinical findings of ocular ischemia syndrome.
RESUMO
PURPOSE: To describe retinal and choroidal vascular changes following an exercise stress test (ET) in patients with effort angina and to determine whether optical coherence tomography angiography (OCT-A) could play a role in the prediction of ischemic cardiac events. METHODS: Prospective comparative study including patients with effort angina. All patients underwent OCT-A before and after an ET was performed. Blood flow, intercapillary spaces, and vessel density were analyzed in the superficial capillary plexus (SCP) and the deep capillary plexus (DCP). Vessel density in the choriocapillaris and the parameters of the central avascular zone (CAZ) were also analyzed. RESULTS: Of the 38 eyes included in the study, a decrease in blood flow was found in 39.5% in the large SCP vessels, in 50% in the capillaris of the SCP, and in 81.6% in the DCP. An increase in intercapillary spaces was observed in the SCP in 68.4% of eyes and in the DCP in 55.3% of eyes. A statistically significant decrease in the DCP density was observed after an ET (p = 0.03). There were no significant modifications in the CAZ parameters, the SCP density, nor the choriocapillaris density. Patients with a positive ET had a decreased DCP density in 83.3%. Among patients with an increased DCP density, 92.85% had a negatif ET. CONCLUSION: This pilot study suggests that DCP density significantly decreases after an ET. The DCP appears to be most affected in patients with effort angina. A larger trial is needed to further investigate these hypotheses.
RESUMO
PURPOSE: To evaluate the reproducibility of SIMPLE (Single field Image Multi Parameters defined Lesions Extent), a new Diabetic Retinopathy (DR) classification for screening of 45° single field fundus pictures of patients with diabetes (PwDM), assessing DR, Diabetic Maculopathy (DMac) and referral rate agreement and comparing it to current Italian Guidelines (IG). MATERIALS AND METHODS: We conducted a retrospective, observational, multicentre study, collecting 1000 retinal 45° single field images of PwDM obtained during routine visits in two diabetes clinics. Three ophthalmologists evaluated each image, determining the presence and number of specific DR lesions and then assigning a stage according to the current IG for screening. SIMPLE staging was performed automatically via Excel software, based on the pre-specified DR characteristics observed by the graders. We analysed intra-centre, inter-centre and total inter-grader agreement for DR and DMac stage and referral rate of the two classifications. RESULTS: Agreement amongst the three graders was consistently higher when using SIMPLE classification than when using current IG classification. For DR, kappa (k) was 0.86 with IG and 0.95 with SIMPLE classification; for DMac, k-IG was 0.78, while k-SIMPLE was 0.96; concordance on the referral rate was 0.91 with IG and 0.99 with SIMPLE. Similar results were obtained in sub-analyses for the evaluation of intra-centre and inter-centre concordance. CONCLUSIONS: Our results suggest that the new SIMPLE classification has an excellent reproducibility amongst graders, comparable or superior to the current IG for DR screening proposed in 2015, improving the standardisation of the decision on referability.
RESUMO
INTRODUCTION: Optical Coherence Tomography Angiography Ratio Analysis (OCTARA) is capable of visualizing inner and outer retinal vascular plexuses, choriocapillaris, and larger choroidal vasculature in vivo without contrast injection. The aim of this study was to assess the intrasession repeatability of automated vessel density measurements using Triton Swept-Source Optical Coherence Tomography Angiography (OCTA) innovative algorithm OCTARA in retinal and choroidal vasculature. METHODS: To study population between 65-90 years old with no eye diseases. For each subject measurements were performed four times. The intraclass correlation coefficient and the coefficient of variation were calculated to analyze repeatability of the OCTARA automatically generated vessel density measurements. RESULTS: A total of 35 eyes were included in the study. The intraclass correlation coefficient of the global vessel density in the superficial capillary plexus and the deep capillary plexus were 0.963 and 0.975, respectively, and the coefficient of variation were 5.4% and 4.4%, respectively. The intraclass correlation coefficient of the rest of the global measurements was indicative of good reliability with the exception of the deep choroid layer with an intraclass correlation coefficient of 0.6 indicative of moderate reliability. CONCLUSIONS: Our results proved excellent repeatability of automated vessel density measurements in the superficial and deep capillary plexus layers in our cohort using a OCTARA algorithm indicating that it may be a reliable diagnostic tool. It also showed good reliability in choriocapillary and mid choroid layer. These findings may be of value in assessing the significance of differences in capillary density measurements over time and across different settings.
RESUMO
This review examines the evolution, current status, and future potential of minimally invasive glaucoma surgeries (MIGS), a significant advancement in the treatment of glaucoma, a leading cause of irreversible blindness. MIGS offer a less invasive alternative to traditional glaucoma surgeries, primarily aimed at reducing intraocular pressure, minimizing tissue trauma, and providing a safer profile. With the emergence of devices such as the Trabectome, iStent, and others, MIGS have expanded the surgical toolkit, allowing personalized, patient-centered care. Despite their advantages, MIGS face challenges such as efficacy in severe cases, long-term data, and accessibility. Ongoing research and technological innovations continue to refine their capabilities and applications, promising to further transform glaucoma management and patient outcomes. This paper provides an in-depth analysis of MIGS, reflecting on their impact and contemplating future directions in this dynamically evolving field.
RESUMO
PURPOSE: To describe and validate a 3D-printed adapter tool which could be used with either a slit lamp or a condensing lens, interchangeable between devices through magnetic fastening, in order to provide physicians a quick, easy and effective method of obtaining clinical photos. MATERIALS AND METHODS: Three specialists, with at least 4-year experience in ophthalmology, gave a rate of image quality obtained by our device and the diagnostic confidence grade. The 3 specialists conducted each 13 or 14 examinations with the smartphone and magnetic adapter. At the end of evaluation, they rated with the Likert scale the ease of use of the device in obtaining clinical images of the anterior segment and ocular fundus respectively. RESULTS: Data of quality perception and confidence demonstrated high values not dissimilar to the "de visu" eye examination. Moreover the instrument we designed turned out to be very user friendly. CONCLUSION: Our adapter coupled with a modern smartphone was able to obtain 4k images and videos of anterior segment, central and peripheral fundus, in an easy and inexpensive way.
RESUMO
Age-related macular degeneration (AMD) is one of the leading causes of vision loss and blindness in older adults. Given the aging population in developed countries and the increased participation of older adults in the labour market, this paper aims to understand the impact of AMD on workplace productivity. Economic studies, comparative studies, observational studies, cohort studies, case series, randomized control trials, clinical trials, multicenter studies from MEDLINE, EMBASE, and CINHAL, as well as grey literature, were systematically searched to obtain all relevant literature. Duplicate records were removed, and two independent reviewers screened records for relevance. After screening, a risk of bias assessment was carried out. Data were extracted and a meta-analysis was performed using STATA 15.0. Fixed-effect and random-effect models were computed based on heterogeneity. Seven studies consisting of 3,060,864 subjects from 5 different countries were included in this systematic review. Mean wages lost due to impaired work productivity ranged from $1,395 to $55,180. The mean unemployment rate attributed to AMD ranged from 5.50% to 77.00%. Meta-analysis results indicated a significant unemployment rate (SMD = 0.44, CI: [0.27, 0.62]). Patients with AMD experience impaired work productivity as demonstrated by the wages lost and significantly higher rates of unemployment.
RESUMO
INTRODUCTION: The aim of this study was to determine a reliable combination of vision-specific measures and general health measures to assess the improvement on the patient's QoL following cataract surgery either when patients had first time surgery or had already received successful surgery in the fellow eye for cataract. METHODS: Study sample included two waves of data measurement in 150 patients undergoing uncomplicated cataract surgery who were assessed for visual acuity, vision-specific quality of life, and general health. Data were acquired pre-surgery and 2 months post-surgery. About 90 patients haven't had prior cataract surgery while 60 patients had prior successful cataract surgery in the fellow eye. RESULTS: There was considerable improvement in all outcome measures following cataract surgery. Patients who have had prior surgery presented with modestly higher scores in the vision-specific QoL measures and minimal benefit pre-operatively compared to those who haven't had any surgery in the general health measure. They also had more gains post-surgery in the vision-specific QoL measures only. CONCLUSIONS: There is a possibility that gains in QoL plateau after a certain level of visual acuity improvement. While improvement can be detected with a general health QoL measure, this measure may require additional psychometric validation to the particular population beforehand. Otherwise, a combination of vision-specific outcome measures will provide the most reliable estimate.
Assuntos
Extração de Catarata , Catarata , Catarata/complicações , Humanos , Avaliação de Resultados em Cuidados de Saúde , Qualidade de Vida , Reprodutibilidade dos TestesRESUMO
INTRODUCTION: 'Digital eye strain' (DES) is a clinical syndrome with eyesight symptoms related to continuous engagement in front of a screen-enabled digital device. With use of these devices constantly on the rise, the related symptoms have become prominent, even in younger ages. This study describes the process of validating the Digital Eye Strain Questionnaire (DESQ), a thirteen-item self-report scale in a yes-no format designed to offer a measure of complaints related to digital eye strain syndrome (DES). METHODS: The validation process included 150 outpatients with no long-standing eye disease who were examined for various eye complaints and 50 outpatients who were diagnosed with gaming addiction according to WHO ICD-11 clinical criteria. All participants filled in a demographics questionnaire, the DESQ, the Computer Vision Syndrome Questionnaire (CVS-Q) and the Problematic Internet Use Questionnaire-9 (PIUQ-9). RESULTS: Principal component analysis of categorical variables confirmed the proposed three-factor DES structure with a total of 61.02% of explained variance and Cronbach's alpha equal to.94. Concurrent validity was assessed by comparing the results of the DESQ to the CVS-Q while convergent validity was assessed by examining correlations of the DESQ with results from the PIUQ-9 questionnaire. In all cases the DESQ demonstrated excellent reliability and validity. CONCLUSIONS: Results indicate that the DESQ questionnaire can be employed to reliably measure the symptomatology of digital eye strain in clinical populations who present either with eye issues or with excessive use of the gaming and screen-enabled devices in general.
Assuntos
Jogos de Vídeo , Visão Ocular , Humanos , Reprodutibilidade dos Testes , Inquéritos e QuestionáriosRESUMO
OBJECTIVE: To evaluate changes in retrobulbar ocular blood flow parameters by using Colour Doppler Imaging (CDI) and changes in foveal microvasculature by using Optical Coherence Tomography Angiography (OCTA) in pediatric obese patients and to compare them with a group of healthy children. METHODS: Children diagnosed with obesity without hypertension and diabetes (39 subjects, obese group) and age-matched healthy controls (26 subjects, control group) underwent CDI and OCTA imaging. Peak systolic velocity, end-diastolic velocity and resistivity index from ophthalmic, central retinal and posterior ciliary arteries on CDI; superficial and deep capillary plexus vascular density and foveal avascular zone area on OCTA imaging were obtained in each group. Central foveal and subfoveal choroidal thicknesses were also measured. CDI and OCTA parameters were compared between two groups. RESULTS: Peak systolic and end-diastolic velocities were found to be significantly lower in obese children than in controls in all three examined arteries (p < 0.05). Resistivity index values were similar between the groups. OCTA imaging did not reveal significant changes in superficial and deep capillary plexus vascular densities and foveal avascular zone area across analysed retinal regions between the groups. Subfoveal choroid was thicker in obese group than in control group (325.89 ± 52.77â µm vs. 304.52 ± 21.76â µm, p = 0.04). CONCLUSION: An apparent decrease was present in retrobulbar hemodynamics in obese children. This arises the possibility of early ocular macrovascular compromise rather than retinal microvascular impairment in childhood obesity.