RESUMO
BACKGROUND: The combined procedure of left atrial appendage closure (LAAC) with concomitant pulmonary vein isolation (PVI) has demonstrated its efficacy and safety. However, there is still a lack of comparative investigations regarding the long-term benefits of the combined procedure when compared to LAAC alone. Our study aims to assess the long-term outcomes of combined procedure of LAAC with concomitant PVI in comparison with a propensity matched LAAC alone group. METHODS: Propensity score matching (PSM) was employed to rectify covariate imbalances, resulting in the inclusion of 153 comparable patients from the initial cohort of 333 non-valvular atrial fibrillation (AF) patients. Clinical outcomes, encompassing thrombotic events, major cardiocerebrovascular adverse events (MACCE), re-hospitalization due to cardiovascular disease (CVD), and atrial tachycardia (AT), were juxtaposed between the two groups. Bleeding events and peri-device complications, such as residual flow, device-related thrombus, and device replacement, were also compared. Additionally, a patients group underwent PVI alone was included for comparing AF recurrence rates between the PVI alone group and the combined group. RESULTS: Following PSM, 153 patients (mean age 70.3 ± 8.9, 62.7% men) were included, with 102 undergoing the combined procedure and 51 undergoing LAAC alone. No significant differences were found in baseline characteristics between the two groups. The mean follow-up time was 37.6 ± 7.9 months, and two patients were lost to follow-up in the combined procedure group. Thrombotic events were observed in 4 (7.8%) patients in the LAAC alone group and 4 (4.0%) in the combined group (Log-rank p = 0.301). The proportion of patients experiencing MACCE, re-hospitalization due to CVD, and AT between the two groups was comparable, as were bleeding events and peri-device complications. Among patients from the combined procedure group without AF recurrence, a significant difference was noted in prior-procedure left ventricular ejection fraction (LVEF) and LVEF at the 12th month after the procedure (57.2% ± 7.1% vs. 60.5% ± 6.5%, p = 0.002). CONCLUSION: The concomitant PVI and LAAC procedure did not increase procedure-related complications, nor did it confer significant benefits in preventing thrombotic events or reducing other cardiovascular events. However, the combined procedure improved heart function, suggesting potential long-term benefits.
Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Acidente Vascular Cerebral , Masculino , Humanos , Feminino , Oclusão do Apêndice Atrial Esquerdo , Veias Pulmonares/cirurgia , Pontuação de Propensão , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Hemorragia/etiologia , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/complicaçõesRESUMO
BACKGROUND: Data comparing remote magnetic catheter navigation (RMN) with manual catheter navigation in combination with contact force sensing (MCN-CF) ablation of atrial fibrillation (AF) is lacking. The primary aim of the present retrospective comparative study was to compare the outcome of RMN versus (vs.) MCN-CF ablation of AF with regards to AF recurrence. Secondary aim was to analyze periprocedural risk, ablation characteristics and repeat procedures. METHODS: We retrospectively analyzed 452 patients undergoing a total of 605 ablations of AF: 180 patients were ablated using RMN, 272 using MCN-CF. RESULTS: Except body mass index there was no significant difference between groups at baseline. After a mean 1.6 ± 1.6 years of follow-up and 1.3 ± 0.4 procedures, 81% of the patients in the MCN-CF group remained free of AF recurrence compared to 53% in the RMN group (P < 0.001). After analysis of 153 repeat ablations (83 MCN-RF vs. 70 RMN; P = 0.18), there was a significantly higher reconnection rate of pulmonary veins after RMN ablation (P < 0.001). In multivariable Cox-regression analysis, RMN ablation (P < 0.001) and left atrial diameter (P = 0.013) was an independent risk factor for AF recurrence. Procedure time, radiofrequency application time and total fluoroscopy time and fluoroscopy dose were higher in the RMN group without difference in total number of ablation points. Complication rates did not differ significantly between groups (P = 0.722). CONCLUSIONS: In our retrospective comparative study, the AF recurrence rate and pulmonary vein reconnection rate is significantly lower with more favorable procedural characteristics and similar complication rate utilizing MCN-CF compared to RMN.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Catéteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fenômenos Magnéticos , Veias Pulmonares/cirurgiaRESUMO
This study aims to determine the predictive value of the soluble suppression of tumorigenicity 2 (sST2) biomarker in atrial fibrillation (AF) recurrence. This prospective, observational study included patients with AF referred for electrical cardioversion (ECV) or pulmonary vein isolation (PVI) procedures. Baseline characteristics were collected, and sST2 was determined at baseline and at 3 and 6 months of follow-up. sST2 was determined at baseline in a matched control group. Left atrial voltage mapping was performed in patients undergoing PVI. The sST2 maximal predictive capacity of AF recurrence was at the 3-month FU in the cohort of patients undergoing ECV with respect to 6-month AF recurrence with an AUC of 0.669, a cut-off point of 15,511 pg/mL, a sensitivity of 60.97%, and a specificity of 69.81%. The ROC curve of the sST2 biomarker at baseline and 3 months in the cohort of patients undergoing PVI showed AUCs of 0.539 and 0.490, respectively. The logistic regression model identified the rhythm (AF) and the sST2 biomarker at 3 months as independent factors for recurrence at 6 months in the ECV cohort. In the logistic regression model, sST2 was not an independent factor for recurrence at 6 months of follow-up in the PVI cohort. In patients who underwent ECV, sST2 values at 3 months may provide utility to predict AF recurrence at 6 months of follow-up. In patients who underwent PVI, sST2 had no value in predicting AF recurrence at 6 months of follow-up.
Assuntos
Fibrilação Atrial , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Cardioversão Elétrica , Proteína 1 Semelhante a Receptor de Interleucina-1 , Veias Pulmonares/cirurgia , Estudos Prospectivos , BiomarcadoresRESUMO
BACKGROUND: Data comparing remote magnetic catheter navigation (RMN) with manual catheter navigation (MCN) ablation of atrial fibrillation (AF) is lacking. The aim of the present prospective observational study was to compare the outcome of RMN versus (vs.) MCN ablation of AF with regards to AF recurrence. METHODS: The study comprised 667 consecutive patients with a total of 939 procedures: 287 patients were ablated using RMN, 380 using MCN. RESULTS: There was no significant difference between the groups at baseline. After 2.3 ± 2.3 years of follow-up, 23% of the patients in the MCN group remained free of AF recurrence compared to 13% in the RMN group (p < .001). After analysis of 299 repeat ablations (133 MCN, 166 RMN) there was a significantly higher reconnection rate of pulmonary veins after RMN ablation p < .001). In multivariable Cox-regression analysis, RMN ablation was an independent risk factor for AF recurrence besides age, persistent AF, number of isolated pulmonary veins, and left atrial diameter. Procedure time, radiofrequency application time and total number of ablation points were higher in the RMN group. Total fluoroscopy time and total fluoroscopy dose were significantly lower for RMN. Complication rates did not differ between groups (p = .842), although the incidence of significant pericardial effusion was higher in the MCN group (seven cases vs. three in RMN group). CONCLUSIONS: In our study the AF recurrence rate and pulmonary vein reconnection rate is higher after RMN ablation with a similar complication rate but reduced probability of pericardial effusion when compared to MCN.
Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Magnetismo/instrumentação , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Recidiva , Reoperação/estatística & dados numéricos , Fatores de RiscoRESUMO
Anatomical-based approaches, targeting either pulmonary vein isolation (PVI) or additional extra PV regions, represent the most commonly used ablation treatments in symptomatic patients with atrial fibrillation (AF) recurrences despite antiarrhythmic drug therapy. PVI remains the main anatomical target during catheter-based AF ablation, with the aid of new technological advances as contact force monitoring to increase safety and effective radiofrequency (RF) lesions. Nowadays, cryoballoon ablation has also achieved the same level of scientific evidence in patients with paroxysmal AF undergoing PVI. In parallel, electrical isolation of extra PV targets has progressively increased, which is associated with a steady increase in complex cases undergoing ablation. Several atrial regions as the left atrial posterior wall, the vein of Marshall, the left atrial appendage, or the coronary sinus have been described in different series as locations potentially involved in AF initiation and maintenance. Targeting these regions may be challenging using conventional point-by-point RF delivery, which has opened new opportunities for coadjuvant alternatives as balloon ablation or selective ethanol injection. Although more extensive ablation may increase intraprocedural AF termination and freedom from arrhythmias during the follow-up, some of the targets to achieve such outcomes are not exempt of potential severe complications. Here, we review and discuss current anatomical approaches and the main ablation technologies to target atrial regions associated with AF initiation and maintenance.
Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Humanos , Resultado do TratamentoRESUMO
AIMS: Atrial fibrillation (AF) is the most prevalent arrhythmia in western countries. It is associated with increased mortality and morbidity and responsible for hospitalization rates of 10-40% per patient per year. Studies from the UK and the USA have shown that AF is responsible for â¼1% of the total healthcare expenditures in these countries. The only potentially curative treatment is pulmonary vein isolation (PVI). Published health economic data on the impact of PVI mainly consist of simulations of expenditures with assumed efficacy taken from ablation studies. Real expenditure data are missing as well as pre-ablation period data and long-term data. METHODS AND RESULTS: We analyse true healthcare expenditures based on inpatient and outpatient data from the Upper Austrian Health Insurance Fund social security system of patients undergoing PVI during 2005 to 2015. We identified 1135 patients undergoing PVI with 268 having multiple procedures. Days of hospitalization and days of sick leave started to rise in the year before ablation. PVI was able to lower both parameters to the level of 1 year before ablation. Comparing four quarters before and after a single-index ablation, a highly significant reduction in inpatient healthcare expenditures was documented. There was a significant, but numerically small increase in outpatient expenditures, resulting in a significant reduction in overall healthcare expenditures. CONCLUSION: Analysing a cohort of the Upper Austrian Health Insurance Fund undergoing PVI, we found significant cost-saving effects on post-interventional healthcare expenditures and a reduction in days of sick leave.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Gastos em Saúde , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/economia , Fibrilação Atrial/cirurgia , Áustria , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do TratamentoRESUMO
We report the entrapment of Pulmonary Vein Ablation Catheter (Medtronic, Minneapolis, MN, USA) and its guidewire within the right pulmonary veins in two patients. The catheters could be retrieved without complications but they were disabled in both cases. This nondescribed incident should be recognized by PVAC users since it may be a source of potential severe complications during pulmonary vein isolation procedures.
Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Veias Pulmonares/cirurgia , Idoso , Remoção de Dispositivo , Desenho de Equipamento , Feminino , Fluoroscopia , HumanosRESUMO
Although cardiac resynchronization therapy (CRT) is an important treatment of symptomatic heart failure patients in sinus rhythm with low left ventricular ejection fraction and ventricular dyssynchrony, its role is not well defined in patients with atrial fibrillation (AF). CRT is not as effective in patients with AF because of inadequate biventricular capture and loss of atrioventricular synchrony. Both can be addressed with catheter ablation of AF. It is still unclear if these therapies offer additive benefits in patients with ventricular dyssynchrony. This article discusses the role and techniques of catheter ablation of AF in patients with heart failure, and its application in CRT recipients.
Assuntos
Fibrilação Atrial/cirurgia , Terapia de Ressincronização Cardíaca/métodos , Ablação por Cateter/métodos , Insuficiência Cardíaca/terapia , Veias Pulmonares/cirurgia , Terapia Combinada , Comorbidade , Medicina Baseada em Evidências , Humanos , Taxa de Sobrevida , Resultado do TratamentoRESUMO
AIMS: Pulmonary vein isolation (PVI) is an accepted treatment to relieve symptoms in patients with atrial fibrillation (AF). We studied 3 year outcome after PVI guided by duty-cycled multi-electrode radiofrequency (RF) ablation (pulmonary vein ablation catheter, PVAC) and provided comparative data to outcome after conventional PVI (CPVI) using mapping with irrigated, point-per-point RF ablation. METHODS AND RESULTS: One hundred and sixty-one consecutive patients with symptomatic paroxysmal or persistent AF and minimal heart disease underwent PVI (PVAC, n = 79 vs. CPVI, n = 82). Follow-up (with symptom-guided rhythm monitoring) was truncated at 3 years in all patients. Success was defined as freedom of documented arrhythmia after a single procedure and without antiarrhythmic drug treatment (ADT). Baseline characteristics did not differ between both groups. At 3 years follow-up, single-procedure success without ADT was comparable between PVAC and CPVI (65% vs. 55%, P = NS). The majority of recurrences occurred during the first year (PVAC 79% vs. CPVI 70%, P = NS). The annual rate of very late recurrence (i.e. beyond 1 year) was similar in both groups (10.5% vs. 15%, P = NS). CONCLUSION: At 3 years follow-up, outcome after PVAC-guided PVI is comparable to conventional isolation by irrigated point-by-point RF ablation. In both strategies, the majority of recurrences occurred in the first year of ablation.
Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Mapeamento Potencial de Superfície Corporal/métodos , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Cirurgia Assistida por Computador/métodos , Mapeamento Potencial de Superfície Corporal/instrumentação , Ablação por Cateter/métodos , Terapia Combinada/instrumentação , Terapia Combinada/métodos , Eletrodos , Feminino , Seguimentos , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Recidiva , Cirurgia Assistida por Computador/instrumentação , Irrigação Terapêutica/instrumentação , Irrigação Terapêutica/métodos , Resultado do TratamentoRESUMO
BACKGROUND: It is suggested that an elevated left atrial pressure (LAP) promotes ectopic beats emanating in the pulmonary veins (PVs) and that LAP might be a marker for structural remodeling. This study aimed to identify if the quantification of LAP correlates with structural changes of the LA and may therefore be associated with outcomes following pulmonary vein isolation (PVI). METHODS: We analysed data from 120 patients, referred to PVI due to drug-refractory atrial fibrillation (AF) (age 63±8; 57% men). The maximum (mLAP) and mean LAP (meLAP) were measured after transseptal puncture. RESULTS AND CONCLUSIONS: Within a mean follow-up of 303±95 days, 60% of the patients maintained in sinus rhythm after the initial procedure and 78% after repeated PVI. Performing univariate Cox-regression analysis, type of AF, LA-volume (LAV), mLAP and the meLAP were significant predictors of recurrence after PVI (p=0.03; p=0.001; p=0.01). In multivariate analysis mLAP>18mmHg, LAV>100 ml and the presence of persistent AF were significant predictors (p=0.001; p=0.019; p=0.017). The mLAP >18 mmHg was associated with a hazard ratio of 3.8. Analyzing receiver-operator characteristics, the area under the curve for mLAP was 0.75 (p<0.01). mLAP >18 mmHg predicts recurrence with a sensitivity of 77 % and specificity of 60 %. There was a linear correlation between the LAV from MDCT and mLAP (p = 0.01, R2 = 0.61). The mLAP measured invasively displays a significant predictor for AF recurrence after PVI. There is a good correlation between LAP and LAV and both factors may be useful to quantify LA remodeling.
RESUMO
Background: Atrio-oesophageal fistulas (AEFs) are an uncommon complication of pulmonary vein ablation, and its diagnosis is challenging. Multidisciplinary interventions and diagnostic imaging are usually required and may play a role in the initial assessment. Case summary: A 69-year-old female with atrial fibrillation who had undergone recent pulmonary vein ablation consulted with unspecific symptoms and sudden hemiparesis. Brain imaging showed pneumocephalus and acute infarcts. Chest computed tomography (CT) was highly suspicious for AEF. Surgical exploration revealed a swollen mediastinum attached to the right inferior pulmonary vein. Discussion: Non-specific symptoms after pulmonary vein ablation should prompt the suspicion of complications. In the presence of fever or neurological deficit, AEF must be suspected and assessed with a contrast-enhanced chest CT, which has become the gold standard. In brain imaging, pneumocephalus and multiple punctate acute infarcts might also indicate the presence of this complication.
RESUMO
BACKGROUND: Since the STAR-AF II trial, there has been a trend toward pulmonary vein isolation (PVI)-only ablation strategies for persistent atrial fibrillation (PeAF). Electrographic Flow (EGF) mapping can identify active sources of AF and estimate the electrographic flow consistency (EGFC) of wavefront propagation through substrate, revealing functional AF mechanisms. OBJECTIVE: Examine the success of a PVI-only ablation strategy for a redo PeAF/long-standing PeAF population. METHODS: FLOW-AF (NCT04473963) prospectively enrolled non-paroxysmal AF patients undergoing redo ablation at 4 centers. One-minute EGF recordings using 64-pole basket catheters were obtained both pre-PVI and post-PVI following a 20-minute wait and confirmation of electrical isolation of veins. Patients with EGF-identified sources were randomized 1:1 to EGF-guided source ablation v. PVI-only. Patients with no sources were not randomized and mostly received PVI-only. RESULTS: Study of 85 patients enrolled: 24 with EGF-identified sources randomized to PVI-only and 23 with no sources receiving PVI-only. Of these 47 patients, those with sources (Group 2) had different clinical characteristics including older age and higher CHA2DS2-VASc compared with those with sources (Group 1). After PVI-only, Group 1 had 70% (16/23) freedom from recurrent AF (FFAF) within one year v. Group 2 with 35% (8/23), p=0.018. Additionally, patients with high electrographic flow consistency (EGFC) indicative of healthy or normal substrate had 67% (10/15) FFAF v. 45% (14/31) in those with low EGFC suggestive of abnormal substrate, p=0.011. CONCLUSION: Success rate in no sources patients receiving PVI-only is better than in those with sources randomized to PVI-only. For the clinically heterogenous population of PeAF patients, the presence of EGF-identified sources matters clinically, and PVI-only will not be enough for all patients.
RESUMO
AIMS: Multidetector computed tomography (MDCT) is frequently used to guide circumferential pulmonary vein ablation (PVA) for treatment of atrial fibrillation (AF) as it offers accurate visualization of the left atrial (LA) and pulmonary vein (PV) anatomy. This study aimed to identify if PV anatomy is associated with outcomes following PVA using remote magnetic navigation (RMN). METHODS AND RESULTS: We analysed data from 138 consecutive patients and 146 ablation procedures referred for PVA due to drug-refractory symptomatic AF (age 63 ± 11 years; 57% men; 69% paroxysmal AF). The RMN using the stereotaxis system and open-irrigated 3.5 mm ablation catheters was used in all procedures. Prior to PVA, all patients underwent electrocardiogram-gated 64-MDCT for assessment of LA dimensions, PV anatomy, and electro-anatomical image integration during the procedure. Regular PV anatomy was found in 68%, a common left PV ostium was detected in 26%, and variant anatomy of the right PVs was detected in 6%. After a mean follow-up of 337 ± 102 days, 63% of the patients maintained sinus rhythm after the initial ablation, and 83% when including repeat PVA. Although acutely successful PV isolation did not differ between anatomical subgroups (regular 3.5 ± 0.8 vs. variant 3.2 ± 1.3; P = 0.31), AF recurrence was significantly higher in patients with non-regular PV anatomy (P = 0.04, hazard ratio 1.72). Pulmonary vein anatomy did not influence complication rates. CONCLUSION: Pulmonary vein anatomy assessed by MDCT is a good predictor of AF recurrence after PVA using RMN.
Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Sistema de Condução Cardíaco/cirurgia , Magnetismo/instrumentação , Veias Pulmonares/cirurgia , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Cirurgia Assistida por Computador/instrumentação , Resultado do TratamentoRESUMO
Background: Wide antral circumferential ablation (WACA) in comparison to ostial pulmonary vein (PV) isolation (PVI) has been attributed with improved rhythm outcome. We investigated the feasibility, lesion formation, and rhythm outcome of WACA-PVI in comparison to ostial-PVI using pulsed field ablation (PFA). Methods: Symptomatic atrial fibrillation (AF) patients (69 years, 67% male; 67% paroxysmal AF) were prospectively enrolled into our single-center registry and underwent first-time ostial-PFA or WACA-PFA, N = 15 each. In all patients, eight pulse trains (2â kV/2.5â s, bipolar, biphasic, 4× basket/flower configuration each) were delivered to each PV. In WACA-PFA, two extra pulse trains in a flower configuration were added to the anterior and posterior antrum of the PVs. For comparison of PFA lesion size, pre- and post-ablation left atrial (LA) voltage maps were acquired using a multipolar spiral catheter together with a three-dimensional electroanatomic mapping system. Results: WACA-PFA resulted in a significant larger lesion formation than ostial-PFA (45.5 vs. 35.1â cm2, p = 0.001) with bilateral overlapping butterfly shape-like lesions and concomitant posterior LA wall isolation in 73% of patients. This was not associated with increased procedure time, sedation dosage, or exposure to radiation. One-year freedom from AF recurrence was numerically higher after WACA-PFA than ostial-PFA (94% vs. 87%) but not statistically significant (p = 0.68). No organized atrial tachycardias (ATs) were observed. Ostial-PFA patients more often underwent re-ablation due to recurrent AF episodes. Conclusion: WACA-PFA is feasible and resulted in significantly wider lesion sets than ostial-PFA. Concomitant posterior LA wall isolation occurred as an epiphenomenon in the majority of patients. The WACA approach was associated with neither increased procedure and fluoroscopy times nor statistically significant differences in 1-year rhythm outcome. ATs were absent.
RESUMO
Aim: To propose a standardized workflow for 3D-electroanatomical mapping guided pulmonary vein isolation in pigs. Materials and methods: Danish female landrace pigs were anaesthetized. Ultrasound-guided puncture of both femoral veins was performed and arterial access for blood pressure measurement established. Fluoroscopy- and intracardiac ultrasound-guided passage of the patent foramen ovale or transseptal puncture was performed. Then, 3D-electroanatomical mapping of the left atrium was conducted using a high-density mapping catheter. After mapping all pulmonary veins, an irrigated radiofrequency ablation catheter was used to perform ostial ablation to achieve electrical pulmonary vein isolation. Entrance- and exit-block were confirmed and re-assessed after a 20-min waiting period. Lastly, animals were sacrificed to perform left atrial anatomical gross examination. Results: We present data from 11 consecutive pigs undergoing pulmonary vein isolation. Passage of the fossa ovalis or transseptal puncture was uneventful and successful in all animals. Within the inferior pulmonary trunk 2-4 individual veins as well as 1-2 additional left and right pulmonary veins could be cannulated. Electrical isolation by point-by-point ablation of all targeted veins was successful. However, pitfalls including phrenic nerve capture during ablation, ventricular arrhythmias during antral isolation close to the mitral valve annulus and difficulties in accessing right pulmonary veins were encountered. Conclusion: Fluoroscopy- and intracardiac ultrasound-guided transseptal puncture, high-density electroanatomical mapping of all pulmonary veins and complete electrical pulmonary vein isolation can be achieved reproducibly and safely in pigs when using current technologies and a step-by-step approach.
RESUMO
Background: The use of pulmonary vein (PV) radiofrequency ablation for atrial fibrillation (AF) treatment may be complicated by PV stenosis or occlusion. A common curative treatment for symptomatic patients is a transcatheter intervention, including percutaneous transluminal balloon angioplasty and stent implantation. Stent implantation itself, however, can be complicated by in-stent stenosis. Case summary: A 26-year-old man presented with worsening exertional dyspnoea due to a total occlusion of both left PVs after the isolation of two PVs for AF. Chest computed tomography (CT) showed chest asymmetry and consolidation of the left lung. The patient was treated with balloon angioplasty and stent placement of both left PVs, resulting in improvement of symptoms, walking distance, and increase in lung space volume by 120â mL based on CT-based volumetry. Ten months later, the patient experienced a recurrence of similar symptoms. A high grade in stent restenosis of the upper left PV and moderate in stent restenosis of the lower PV were diagnosed and treated with angioplasty. The patient was discharged from the hospital in good clinical condition 3 days after the intervention. Discussion: Non-specific symptoms of PV stenosis or occlusion, such as shortness of breath, fatigue, flu-like symptoms, reduced physical performance, and haemoptysis delay the diagnosis. If unusual symptoms appear abruptly after PV isolation, a PV stenosis should be considered. In this case, we describe for the first time a partially reversible consolidation of lung parenchyma following the revascularization of both PVs.
RESUMO
BACKGROUND: In atrial fibrillation (AF) patients, catheter ablation of pulmonary veins (PVI) is the most effective therapeutic option to maintain sinus rhythm. To improve successful PVI, contact force-sensing (CF) catheters became routinely available. Previous studies did not clearly show superior clinical efficacy in comparison with non-CF catheters. METHODS: We investigated consecutive patients, who underwent index PVI for AF at our hospital between 2012 and 2018. Three hundred and fifty-four patients were ablated without CF. After availability of CF catheters in 2016, 317 patients were ablated using CF. In case of crossover between the groups, follow-up was censored. The primary endpoint was any documented atrial tachycardia (AT) or atrial fibrillation > 30 s after a 3-month blanking period. Secondary endpoints were procedural characteristics and periprocedural complications. RESULTS: There was no significant difference between the groups at baseline except hyperlipidemia. After 365 days of follow-up, 67% of patients in the CF group remained free from AF/AT recurrence compared to 59% in non-CF group (P = 0.038). In multivariable Cox regression analysis, non-CF ablation was an independent risk factor for AF recurrence besides age and persistent AF. Total fluoroscopy time (15 ± 7.6 vs. 28 ± 15.9 min) and total procedure time (114 ± 29.6 vs. 136 ± 38.5 min) were significantly lower for CF-guided PVI (P < 0.001). Complication rates did not differ between groups (P = 0.661). CONCLUSIONS: In our study, the AT/AF recurrence rate and pulmonary vein reconnection rate is lower after CF PVI with a similar complication rate but lower total procedure time and total fluoroscopy time compared to non-CF PVI.
Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/cirurgiaRESUMO
Background and aim: To investigate the feasibility, acute efficacy, periprocedural safety, and procedural parameters of CB-based PVI guided by KODEX-EPD using different occlusion tool software versions. Methods and results: A total of 173 patients (60/173 (35%) paroxysmal AF, 64 ± 12 years, 66/173 (38%) female), underwent CB-based PVI guided by KODEX-EPD between August 2019 and October 2021. Acute PVI was achieved in all the patients. Total fluoroscopy time and dye volume were 13.9 [10.6-19.4] min and 47.5 [20-70] ml. Periprocedural complications occurred in 3 (2%) of the 173 patients. As part of the continued development program, different software versions were used, including 1.4.6 on 38 (22%), 1.4.6a on 33 (19%), 1.4.7 on 41 (24%), and 1.4.8 on 61 (35%) of the patients. Outcomes were compared between software versions by a univariate analysis. Sensitivity analyses were performed to account for confounders. Median fluoroscopy time was decreased by 6.4 min (37.3%), and the median volume of dye was decreased by 32.5 ml (52%) from versions 1.4.6 to 1.4.8. Software version was a significant predictor of fluoroscopy time and dye volume, while reductions in procedure duration and dose area product were observed but mainly explained via confounders. Conclusion: CB-based PVI guided by KODEX-EPD is feasible and safe. Progressive software improvements appear to be associated with lower fluoroscopy duration and dye use. Further studies are needed to evaluate the advantage of KODEX-EPD-guided compared to conventional CB-PVI.
RESUMO
Pulsed-field ablation (PFA) had potential advantages in atrial fibrillation ablation, and we aim to confirm the optimal parameter and target of PFA for atrial fibrillation. Two ablation modes in vitro of single-cell system (ablation in electrode cup) and monolayer cell system (ablation in inserts with electrode tips) were established to perform PFA for myocardial cell H9C2 and smooth muscle cell A7r5. Ablation effect, calcium ion influx, the expression of Cx45, and surface morphological change were observed. Three Bama minipigs were used to verify the in vivo ablation effect of PFA. In monolayer cell system, H9C2 was significantly sensitive to PFA compared with A7r5, with shrinking of the whole monolayer. The ablation effect of bidirectional pulse was weaker than that of the two mono-polar pulses. Expressed Cx45 proteins were increased in H9C2 but decreased in A7r5 cells. Bidirectional PFA performed on Bama minipigs was able to effectively block electrical activity from the pulmonary vein to the atrium with week muscle contraction, not generating pulmonary vein stenosis. Bidirectional PFA was able to significantly ablate myocardial cells, maintain cell-cell connection, and reduce muscle contraction, which was a kind of optimized PFA strategy for atrial fibrillation.
RESUMO
Background: Several methods have been reported for locating the conduction gap (CG) in the pulmonary vein isolation (PVI) ablation line. However, the value of the interval between far-field atrial potential (FFP) and pulmonary vein potential (PVP) remains unknown. Methods: Consecutive patients with a CG during observation on the table after PVI were included. The PVP, FFP, and the CG location were evaluated to develop a novel algorithm to identify the CG location in the left superior pulmonary vein. The performance of this novel algorithm was prospectively tested in a validation cohort of consecutive patients undergoing repeat PVI ablation. Results: A total of 116 patients with atrial fibrillation (AF) were recruited, 56 of whom formed the validation cohort. The interval between FFP and PVP of the left superior pulmonary vein was associated with the CG location, and an interval <5 ms predicted the presence of CG in the upper portion of the ostium with a sensitivity of 92.9% and a specificity of 96.9%. In the prospective evaluation, the interval was able to correctly predict the site of CG in 89.6% of cases. Conclusions: The interval between FFP and PVP is a novel and accurate index that can be used to predict the CG location in the left superior pulmonary vein. An far-field atrial potential and pulmonary vein potential (FFP-PVP) interval value of ≥5 ms could be used to exclude a CG in the upper portion of the ostium in the majority of patients undergoing AF ablation.