Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(3): 422-432, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38205929

RESUMO

INTRODUCTION: Acute pulmonary vein reconnection (PVR) via epicardial fibers can be found during observation period after PV isolation, the characteristics and related factors have not been fully studied. We aimed to investigate the prevalence, locations, electrogram characteristics, and ablation parameters related to acute epicardial pulmonary vein reconnection (AEPVR). METHODS: Acute PVR was monitored during observation period after PV isolation. AEPVRs were mapped and distinguished from endocardial conduction gaps. The clinical, electrophysiological characteristics and lesion set parameters were compared between patients with and without PVR. They were also compared among AEPVR, gap-related reconnection, and epicardial PVR in repeat procedures. RESULTS: A total of 56.1% acute PVR were AEPVR, which required a longer waiting period (p < .001) than endocardial gap. The majority of AEPVR were connections from the posterior PV carina to the left atrial posterior wall, followed by late manifestation of intercaval bundle conduction from the right anterior carina to right atrium. AEPVR was similar to epicardial PVR in redo procedures in distribution and electrogram characteristics. Smaller atrium (p < .001), lower impedance drop (p = .039), and ablation index (p = .028) on the posterior wall were independently associated with presence of AEPVR, while lower interlesion distance (p = .043) was the only predictor for AEPVR in acute PVR. An integrated model containing multiple lesion set parameters had the highest predictive ability for AEPVR in receiver operating characteristics analysis. CONCLUSIONS: Epicardial reconduction accounted for the majority of acute PVR. AEPVR was associated with anatomic characteristics and multiple ablation-related parameters, which could be explained by nondurable transmural lesion or late manifestation of conduction through intercaval bundle.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Frequência Cardíaca , Recidiva
2.
Artigo em Inglês | MEDLINE | ID: mdl-38956821

RESUMO

BACKGROUND: Despite advances in efficacy and safety of pulmonary vein isolation (PVI), atrial fibrillation (AF) recurrence after PVI remains common. PV-reconnection is the main finding during repeat PVI procedures performed to treat recurrent AF. OBJECTIVE: To analyze pulmonary vein (PV) reconnection patterns during repeat ablation procedures in a large cohort of consecutive patients undergoing radio frequency or cryoballoon-based PVI. METHODS: Retrospective analysis of PV-reconnection patterns and analysis of re-ablation strategies in consecutive index RF- and CB-based PVI and their respective re-ablation procedures during concomitant usage of both energy sources at a single high-volume center in Germany. RESULTS: A total of 610 first (06/2015-10/2022) and 133 s (01/2016-11/2022) repeat ablation procedures after 363 (60%) RF- and 247 (40%) CB-based index PVIs between 01/2015 and 12/2021 were analyzed. PV-reconnection was found in 509/610 (83%) patients at first and 74/133 (56%) patients at second repeat procedure. 465 of 968 (48%) initially via CB isolated PVs were reconnected at first re-ablation but 796 of 1422 initially RF-isolated PV (56%) were reconnected (OR: 0.73 [95% CI: 0.62-0.86]; p < .001). This was driven by fewer reconnections of the left PVs (LSPV: OR: 0.60 [95% CI: 0.42-0.86]; p = .005 and LSPV: 0.67 [0.47-0.95]; p = .026). PV-reconnection was more likely after longer, RF-based index PVI and in older females. Repeat procedures were shorter after CB-compared to after RF-PVI. CONCLUSIONS: Reconnection remains the most common reason for repeat AF ablation procedures after PVI. Our data suggest to preferentially use of the cryoballoon during index PVI, especially in older women.

3.
Artigo em Inglês | MEDLINE | ID: mdl-39166371

RESUMO

INTRODUCTION: Management of patients with long-standing persistent atrial fibrillation (LSPAF) presents a clinical challenge. Hybrid convergent ablation has been shown to have superior efficacy compared to endocardial-only ablation. However, data on concomitant left atrial appendage (LAA) management along with hybrid ablation is sparse. METHODS: We aimed to evaluate the effectiveness of concomitant hybrid convergent ablation and LAA clipping in patients with LSPAF. We conducted a retrospective analysis of all patients with LSPAF who underwent hybrid surgical ablation with LAA clipping at our institution. The primary endpoint was a recurrence of atrial arrhythmias at 12 months. Further, the durability of surgical left atrial posterior wall ablation was examined during the endocardial catheter ablation using standing electrophysiological criteria. RESULTS: A total of 79 patients were included. Mean age was 63.5 ± 9.6 years, and 71% were males. LAA clipping was performed in 99% of patients. The mean time between the surgical and endocardial stages of the procedure was 2.6 ± 1.7 months. Persistent posterior wall activity was observed in 34.2% (n = 27/79) patients during the endocardial phase of the procedure. Cardiac implantable electronic device was used in 74% of patients for monitoring of recurrence of atrial fibrillation (AF). The primary effectiveness of AF freedom at 12 months was 73.8% (45/61). Over a 12-month follow-up period, 11.4% (9/79) of patients required repeat catheter ablation, of which 88.9% (8/9) had evidence of persistent posterior wall activity. CONCLUSION: Concomitant hybrid convergent ablation and LAA exclusion with an atrial clip provides reasonable long-term AF-free survival in patients with LSPAF. Persistent posterior wall activity is seen commonly in patients presenting with recurrent AF following hybrid convergent AF ablation.

4.
Heart Vessels ; 2024 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-39348036

RESUMO

In patients with atrial fibrillation (AF) recurrence after pulmonary vein (PV) isolation, noninvasive markers predicting PV reconnection or PV reconnection sites have not been fully elucidated. This study investigated the relationship between the P-wave terminal force in lead V1 (PTFV1) and the PV reconnection or reconnection site in patients with AF recurrence. We retrospectively studied consecutive patients who underwent second AF ablation between April 1, 2018, and June 1, 2023. PTFV1 was investigated before the first AF ablation (pre-ablation PTFV1) and before the second AF ablation (post-ablation PTFV1). In addition, we examined the ratio of the post-ablation to pre-ablation PTFV1 (PTFV1 ratio). These values were compared between patients with and without PV reconnection, with and without left PV (LPV) reconnection, and with and without right PV (RPV) reconnection. The analysis included 56 patients. PTFV1 was reduced because of the first AF ablation. In addition, the values were more decreased in patients without PV reconnection than with PV reconnection. The PTFV1 ratio was significantly smaller in the patients without LPV reconnection than with LPV reconnection; no significant difference was observed between the patients with and without RPV reconnection. Receiver operating characteristic curve analysis showed that a PTFV1 ratio > 0.69 predicted LPV reconnection with 70.0% sensitivity and 66.7% specificity. In conclusion, the PTFV1 ratio may be a noninvasive marker predicting LPV reconnection in patients with AF recurrence.

5.
J Cardiovasc Electrophysiol ; 34(12): 2452-2460, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37787003

RESUMO

INTRODUCTION: Although first-pass isolation (FPI) of the pulmonary vein (PV) has been suggested as a marker for PV isolation (PVI) durability, it has not been confirmed. Non-PV atrial fibrillation (AF) triggers were the main target in patients without PV reconnection in the second ablation procedure, but the outcome was unclear. We aimed to validate FPI as a marker of PVI durability and evaluate the outcome after the second procedure in patients without PV reconnection by comparing it to those with reconnection. METHODS: Among the 2087 patients undergoing the first ablation index-guided radiofrequency AF ablation, 309 with atrial tachyarrhythmias (ATs) recurrence and undergoing the second procedure were studied. Clinical characteristics and outcomes were compared between the patients without PV reconnection (PV non-reconnection group, n = 142) and with reconnection (PV reconnection group, n = 167). RESULTS: FPI in both PV sides in the first ablation procedure was significantly more frequent in the PV non-reconnection group (77.5%) than in the PV reconnection group (45.5%) (p < .001). Multivariate logistic regression analysis revealed that FPI (odds ratio, 3.71 [95% confidence interval, 2.23-6.19], p < .001) was the only predictor of PV non-reconnection. Radiofrequency applications for non-PV AF triggers were more frequently performed in the PV non-reconnection group (40.8% vs. 24.6%, respectively, p < .001). Kaplan-Meier analysis revealed that AT recurrence-free rate was significantly lower in the PV non-reconnection group (1-year recurrence-free rate, 62.7% vs. 75.4%, respectively; p = .01 by log-rank test). CONCLUSION: FPI was the only independent predictor of PV non-reconnection. Despite aggressive ablation for non-PV triggers, AT recurrence was more frequent in patients with PV non-reconnection.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
6.
Europace ; 25(2): 360-365, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36125227

RESUMO

AIMS: Electrical reconnection of pulmonary veins (PVs) is considered an important determinant of recurrent atrial fibrillation (AF) after pulmonary vein isolation (PVI). To date, AF recurrences almost automatically trigger invasive repeat procedures, required to assess PVI durability. With recent technical advances, it is becoming increasingly common to find all PVs isolated in those repeat procedures. Thus, as ablation of extra-PV targets has failed to show benefit in randomized trials, more and more often these highly invasive procedures are performed only to rule out PV reconnection. Here we aim to define the ability of late gadolinium enhancement (LGE)-magnetic resonance imaging (MRI) to rule out PV reconnection non-invasively. METHODS AND RESULTS: This study is based on a prospective registry in which all patients receive an LGE-MRI after AF ablation. Included were all patients that-after an initial PVI and post-ablation LGE-MRI-underwent an invasive repeat procedure, which served as a reference to determine the predictive value of non-invasive lesion assessment by LGE-MRI.: 152 patients and 304 PV pairs were analysed. LGE-MRI predicted electrical PV reconnection with high sensitivity (98.9%) but rather low specificity (55.6%). Of note, LGE lesions without discontinuation ruled out reconnection of the respective PV pair with a negative predictive value of 96.9%, and patients with complete LGE lesion sets encircling all PVs were highly unlikely to show any PV reconnection (negative predictive value: 94.4%). CONCLUSION: LGE-MRI has the potential to guide selection of appropriate candidates and planning of the ablation strategy for repeat procedures and may help to identify patients that will not benefit from a redo-procedure if no ablation of extra-PV targets is intended.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Meios de Contraste , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Gadolínio , Resultado do Tratamento , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Imageamento por Ressonância Magnética , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
7.
Pacing Clin Electrophysiol ; 46(6): 535-542, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36689951

RESUMO

BACKGROUND: Durable electrical isolation of pulmonary veins (PVs) is associated with better outcomes after atrial fibrillation (AF) ablation, but previous studies of AF recurrence have reported high rates of reconnection despite successful acute isolation. This study aims to quantify historical trends in the durability of PV isolation (PVI) as radiofrequency (RF) ablation catheters, additional ablation technologies, and associated workflows have evolved. METHODS: The study population included adult patients receiving a first repeat ablation for AF between September 2013 and July 2019 at the study site. All index ablations were performed at the same site with an RF catheter and included PVI. Three generations of irrigated RF catheters based on the same technology platform were used by the site during the timeframe of this study. RESULTS: A total of 224 patients were included in the analysis. At repeat ablation, the mean number of patients with at least one reconnected PV dropped significantly with subsequent catheter generation, from 78.3% to 56.7% to 27.0% (p < .0001). Moreover, the mean number of reconnected PVs were significantly reduced from 1.48 to 0.92 to 0.47 (p < .0001), representing a 68.3% reduction across the 3 generations of devices. CONCLUSION: Significant improvement in durable PVI was seen with successive generations of RF catheter over a 6-year period. In addition to catheter technology, ancillary advances in ablation technologies, workflows, and operator experience likely contributed to these improvements.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Adulto , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Fatores de Tempo , Recidiva
8.
J Cardiovasc Electrophysiol ; 33(6): 1136-1145, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35118734

RESUMO

INTRODUCTION: Ablation of atrial fibrillation (AF) with high-power-short-duration (HPSD) radiofrequency (RF) technology is emerging as a new standard of care in many electrophysiology laboratories. While procedural short-term efficacy and efficiency is very promising, little is known about mid- to long-term effects of HPSD ablation for pulmonary vein isolation (PVI) and left atrial substrate modification. METHODS: In a single-center registry, 412 AF procedures were performed in 400 individual patients using a standardized CLOSE protocol-guided fixed 50 W HPSD ablation, aiming for an ablation index (AI) of 400 on the posterior and 550 on the anterior wall. Additional substrate-tailored lines were performed when required. RESULTS: After a mean clinical follow-up of 337 ± 134 days, 15 patients suffered from AF recurrence beyond the blinding period. Twelve gave consent to the indicated reablation. Here, 11 of 12 patients had chronic isolation of all four pulmonary veins (PV). In three of six patients, a reconnection of additional left atrial ablation lines was revealed. Ten out of 12 patients showed progressive fibrous atrial cardiomyopathy and required additional left atrial substrate modification or reisolation of left-atrial lines. During the follow-up no clinical case of atrioesophageal fistula was registered. No PV stenosis after initial HPSD PVI was documented. CONCLUSIONS: Patients requiring reablation of AF or other atrial tachycardia after a fixed 50 W HPSD circumferential PVI and substrate modification predominantly suffer from progressive fibrous atrial cardiomyopathy, while PV reconnection appears to be a rare cause of AF recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
9.
Pacing Clin Electrophysiol ; 45(11): 1323-1329, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35959745

RESUMO

BACKGROUND: Although much has been discussed about the early recurrence of atrial fibrillation (ERAF) after cryoballoon ablation (CBA), the clinical impact of very early recurrence of atrial fibrillation (VERAF) after CBA remains unclear. This study aimed to investigate the impact of VERAF after CBA. METHODS: We enrolled 236 consecutive patients who underwent an initial CBA for paroxysmal atrial fibrillation between February 2017 and December 2020 in our hospital. These patients were categorized into three groups: VERAF group who experienced an initial recurrence of atrial tachyarrhythmia within 48 h after CBA, late-ERAF (LERAF) group who experienced an initial recurrence of atrial tachyarrhythmia between 48 h and 3 months after CBA, and non-ERAF (NERAF) group who did not experience a recurrence of atrial tachyarrhythmia within 3 months after CBA. We investigated the late recurrence of AF (LRAF, defined as recurrence of atrial tachyarrhythmia more than 3 months after CBA), and the incidence of non-pulmonary vein (PV) triggers in the patients who experienced a repeat ablation procedure due to LRAF. RESULTS: VERAF group had a higher incidence of freedom from LRAF than LERAF group (p = 0.032) and a lower incidence of freedom from LRAF than NERAF group (p = 0.002). Moreover, VERAF group had the highest incidence of non-PV triggers at repeat ablation procedure among the three groups (p = 0.003). CONCLUSIONS: While ERAF was a predictor of LRAF, VERAF was less related to LRAF among the patients with ERAF after CBA. Furthermore, VERAF might be associated with non-PV triggers.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Recidiva , Fatores de Risco , Fatores de Tempo , Veias Pulmonares/cirurgia , Resultado do Tratamento
10.
Heart Vessels ; 37(11): 1882-1891, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35552483

RESUMO

At present, it remains unclear whether the effect on cryoinjury can be strongly exerted by contact of the balloon with the pulmonary vein (PV) ostium. The present study included 204 paroxysmal atrial fibrillation (PAF) patients who underwent an initial pulmonary vein isolation (PVI) using a cryoballoon from the Osaka Rosai Atrial Fibrillation ablation (ORAF) registry. The total balloon contact angle was measured from the equator line (sum of the angles of the upper side and bottom side in all PVs) under fluoroscopic imaging. The patients were stratified into three tertile groups according to the total balloon contact angle. We evaluated the relationship between the total balloon contact angle and clinical outcomes, including the value of acute myocardial injury marker (high-sensitive cardiac troponin I [hs-TnI]), arrhythmia recurrence, and PV reconnections in the repeated ablation. The total balloon contact angle was significantly associated with the hs-TnI value among the tertile groups (p < 0.001) and a multiple regression analysis showed that the total balloon contact angle significantly correlated with the hs-TnI value (standardized beta-coefficient = 0.572, p < 0.001). The balloon contact angle in PVs with PV reconnections was significantly lower than in those without (p = 0.044), while no significant differences in the recurrence of atrial fibrillation among the tertile groups were observed in the enrolled patients. The total balloon contact angle was significantly associated with the acute myocardial injury marker, hs-TnI. The total balloon contact angle was significantly associated with PV reconnections after cryoballoon ablation in patients who underwent a repeat ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Traumatismos Cardíacos , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Traumatismos Cardíacos/diagnóstico , Traumatismos Cardíacos/etiologia , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento , Troponina I
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA