Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Environ Sci Technol ; 57(44): 17042-17050, 2023 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-37878501

RESUMO

Onsite wastewater treatment systems (OWTSs) are important nonpoint sources (NPSs) of pollution to consider in watershed management. However, limited OWTS data availability makes it challenging to account for them as an NPS of water pollution. In this study, we succeeded in obtaining OWTS permits and integrated them with environmental data to model the pollution potential from OWTSs at the watershed scale using GIS-based multicriteria decision analysis. Then, in situ water quality parameters─Escherichia coli (E. coli), total nitrogen, total phosphorus, temperature, and pH─were measured along the main tributary at base-flow conditions. Three general linear models were developed to relate E. coli to water quality parameters and OWTS pollution indicators. It was found that the model with the OWTS pollution potential had the lowest corrected Akaike information criterion (AICc) value (35.01) compared to the models that included classified OWTS pollution potential input criteria (AICc = 36.76) and land cover (AICc = 36.74). These results demonstrate that OWTSs are a significant contributor to surface water pollution, and future efforts should be made to improve access to OWTS data (i.e., location and age) to account for these systems as an NPS of water pollution.


Assuntos
Monitoramento Ambiental , Purificação da Água , Monitoramento Ambiental/métodos , Escherichia coli , Poluição da Água , Qualidade da Água
2.
Environ Sci Technol ; 57(42): 15771-15779, 2023 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-37819045

RESUMO

Progress toward Sustainable Development Goals for global access to safe sanitation is lagging significantly. In this Feature, we propose that misleading terminology leads to errors of categorization and hinders progress toward sanitation service provision in urban areas. Binary classifications such as "offsite/onsite" and "sewered/nonsewered" do not capture the need for "transport to treatment" or the complexity of urban sanitation and should be discarded. "Fecal sludge management" is used only in the development context of low- or middle-income countries, implying separate solutions for "poor" or "southern" contexts, which is unhelpful. Terminology alone does not solve problems, but rather than using outdated or "special" terminology, we argue that a robust terminology that is globally relevant across low-, middle-, and upper-income contexts is required to overcome increasingly unhelpful assumptions and stereotypes. The use of accurate, technically robust vocabulary and definitions can improve decisions about management and selection of treatment, promote a circular economy, provide a basis for evidence-based science and technology research, and lead to critical shifts and transformations to set policy goals around truly safely managed sanitation. In this Feature, the three current modes of sanitation are defined, examples of misconceptions based on existing terminology are presented, and a new terminology for collection and conveyance is proposed: (I) fully road transported, (II) source-separated mixed transport, (III) mixed transport, and (IV) fully pipe transported.


Assuntos
Saneamento , Esgotos , Fezes
3.
Environ Res ; 223: 115475, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36773635

RESUMO

Anaerobic baffled reactor (ABR) is widely used in rural sewage treatment due to its unique structure, strong impact load resistance, and low energy consumption. However, there is a lack of research on pollutant degradation patterns and microbial community succession patterns in each compartment of ABR. In this study, a packed anaerobic baffled reactor (PABR) was constructed. The effects of T and HRT on the pollutant removal performance of PABR were investigated, and the pollutant degradation and microbial community succession in different compartments of PABR were studied. The results show that the removal rates of COD, NH4+-N, and TN of PABR can reach 85.54 ± 1.08%, 16.94 ± 1.01%, and 5.64 ± 1.18% respectively, and PABR has a good pollutant removal effect. With the extension of HRT, the COD removal rate of PABR increases steadily, and the NH4+-N and TN removal rate of PABR increases to a certain extent. The recommended HRT is 72 h. T has a significant impact on the COD removal effect of PABR. The increase of T in a certain range is conducive to the removal of pollutants by PABR. The COD removal rate of PABR decreases gradually along the flow direction, and the removal of organic matter is mainly concentrated in the first compartment. PABR has good removal capacity for CODss and better nitrogen removal capacity compared with traditional ABR. The richness and diversity of the microbial community in PABR increased gradually along the flow direction. The bacterial species in each compartment were similar but the proportion was different, showing the characteristics of multi-stage and separated phase operation. This study provides a new reference for the application of ABR in rural sewage treatment.


Assuntos
Poluentes Ambientais , Águas Residuárias , Anaerobiose , Esgotos , Reatores Biológicos/microbiologia , Eliminação de Resíduos Líquidos/métodos
4.
J Environ Manage ; 345: 118922, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37688963

RESUMO

Treatment of septic tank wastewater (STWW) with high concentrations of ammonium (NH4+) and total phosphorus (TP), is challenging in decentralized areas. Utilizing microalgae for STWW treatment can simultaneously recover nutrients in the form of high-value microalgal biomass. However, despite the potential benefits, microalgal treatment of STWW is rarely reported. Therefore, this work utilized bench-scale photobioreactors (PBR) to investigate different factors that could affect microalgal cultivation in STWW and treatment efficiency. Accordingly, it was observed that suspended solids present in STWW did not significantly affect the microalgae growth and nutrient removal efficiencies in bubble column PBR. On the other hand, the effect of endemic microorganism could not be verified in this study due to observed fungal contamination and change in nutrient profile of STWW after autoclave. Nevertheless, the highest microalgal growth and nutrient removal efficiencies of NH4+-N = 79.14% and TP = 41.11% were observed within 14 days of photoautotrophic cultivation in raw STWW. Further, 25 days of upscaled photoautotrophic cultivation in 4-L bubble column PBR was performed to study biomass yield, nutrient removal kinetics, and nutrient removal efficiency. Consequently, 0.75 g‧L-1 dry biomass was produced with improved removal efficiency of NH4+-N (96.16%), and TP (69.57%). Elemental analysis of biomass revealed that 62.99 ± 1.46 mg‧L-1 TN and 11.41 ± 1.42 mg‧L-1 TP were recovered. Further, 1.02 geq carbon dioxide (CO2) was bio-fixed with every liter of STWW treated. The findings of this study revealed that microalgae can be successfully utilized for the removal and recovery of nutrients from STWW.


Assuntos
Microalgas , Águas Residuárias , Biomassa , Dióxido de Carbono , Nutrientes , Fósforo
5.
J Environ Manage ; 304: 114199, 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-34864407

RESUMO

On-site domestic wastewater treatment systems (DWTS) are used by a significant fraction of the world's population and are used by one third of the population in Ireland. The effective operation of these DWTS requires regular desludging and so knowledge of expected filling rates is essential for both the homeowner as well as the municipalities which accept this sludge in licensed premises; yet few studies have attempted to quantify the sludge accumulation in such decentralized systems. Field studies were carried out on 27 septic tanks across Ireland to quantify sludge accumulation rates from which optimum desludging frequencies for use in Ireland have then been determined. Sludge accumulation was found to be very high in the first 12 months of system operation (approximately 250 L/person/y) but dropped off to below 150 L/person/y after 2 years. Such volumetric accumulation rates appear high compared to the few other reported international studies; however, measured solids accumulation rates, were low compared to international estimates, ranging from 1 to 10 kg/person/y. An equation for optimal desludging frequencies between 3 and 5 years has been formulated for various tank sizes and occupancy based on the Irish field data and previous international research - 5 years being the maximum allowable interval between desludging before the limiting volume of 50% sludge in the tank is reached.


Assuntos
Esgotos , Purificação da Água , Humanos , Irlanda , Eliminação de Resíduos Líquidos , Águas Residuárias
6.
Biodegradation ; 32(1): 17-36, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33230597

RESUMO

Anaerobic systems for domestic sewage treatment, like septic tanks and anaerobic filters, are used in developing countries due to favorable economic and functional features. The anaerobic filter is used for the treatment of the septic tank effluent, to improve the COD removal efficiency of the system. The microbial composition and diversity of the microbiome from two wastewater treatment systems (factory and rural school) were compared through 16S rRNA gene sequencing using MiSeq 2 × 250 bp Illumina sequencing platform. Additionally, 16S rRNA data were used to predict the functional profile of the microbial communities using PICRUSt2. Results indicated that hydrogenotrophic methanogens, like Methanobacterium, were found in higher abundance in both systems compared to acetotrophic methanogens belonging to Methanosaeta genus. Also, important syntrophic microorganisms (Smithella, Syntrophus, Syntrophobacter) were found in the factory and rural school wastewater treatment systems. Microbial communities were also compared between stages (septic tank and anaerobic filter) of each wastewater treatment stage, revealing that, in the case of the rural school, both microbial communities were quite similar most likely due to hydraulic short-circuit issues. Meanwhile, in the factory, microbial communities from the septic tank and anaerobic filter were different. The school system showed lower COD removal rates (2-30%), which were probably related to a higher abundance of Firmicutes members in addition to the hydraulic short-circuit and low abundance of Chloroflexi members. On the other hand, the fiberglass factory presented higher COD removal rates (60-83%), harboring phyla reported as the core microbiome of anaerobic digesters (Bacteroidetes, Chloroflexi, and Proteobacteria phyla). The knowledge of the structure and composition of wastewater treatment systems may provide support for the improvement of the pollutant removal in anaerobic process.


Assuntos
Microbiota , Esgotos , Anaerobiose , Biodegradação Ambiental , Reatores Biológicos , Microbiota/genética , RNA Ribossômico 16S/genética , Eliminação de Resíduos Líquidos , Águas Residuárias
7.
J Environ Manage ; 290: 112612, 2021 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-33906118

RESUMO

Classifications for onsite sanitation in terms of facility type (septic tanks, pit latrines) exist, but connecting these facilities to the wider sanitation value chain via improved containment, emptying, and collection has not been well explored. Using existing Joint Monitoring Programme facility classifications and secondary data on piped water access, a Service Typology was developed to classify and quantify the primary emptying service needs of household level onsite sanitation facilities. Facilities in six Sustainable Development Goal (SDG) regions were classified as Emptiable (faecal sludge can be removed either via Mechanized or Non-Mechanized means) or Unemptiable. Of the 722 million household level sanitation facilities assessed in these regions, 32% were found to be emptiable via Mechanized means, 50% via Non-Mechanized means and 18% were found to be Unemptiable pits. The volume (by number of facilities) and density (as a proportion of the full population) of each service type were estimated by SDG region and by country. Results from this study provide background data on the role of emptying sanitation facilities in achieving SDG6, and can be incorporated into investment priorities, policy framing, technology development, infrastructure development, and targeted behaviour change strategies.


Assuntos
Países em Desenvolvimento , Saneamento , Fezes , Esgotos , Banheiros
8.
J Environ Manage ; 300: 113709, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34547574

RESUMO

Improved sanitation is critical important to reduce the spread of human deposited pathogens and antibiotic resistance genes (ARGs). In the China's rural "Toilet Revolution", three-compartment septic tanks (SPTs) are widely used as household domestic sewage treatment facilities. The effluents of SPTs are encouraged to be used as fertilizer in agriculture. However, whether SPT could eliminate fecal pathogens and ARGs is still unrevealed which is crucial in risk assessment of SPT effluent utilization. Herein, we employed metagenomic sequencing to investigate the pathogens and ARGs in rural household SPTs from Tianjin, China. We found that rural household SPT effluents conserved pathogens comparable to that of the influents. A total of 441 ARGs conferring resistance to 26 antibiotic classes were observed in rural household SPTs, with the relative abundance ranging from 709 to 1800 ppm. Results of metagenomic assembly indicated that some ARG-MGE-carrying contigs were carried by pathogens, which may pose risk to human and animal health after being introduced to the environment. This study raises the question of SPTs as sustainable on-site treatment facilities for rural domestic sewage and underscores the need for more attention to the propagation and dissemination of antibiotic-resistant pathogens from SPT to the environments, animals, and humans.


Assuntos
Bactérias , Genes Bacterianos , Animais , Bactérias/genética , Resistência Microbiana a Medicamentos/genética , Humanos , Metagenômica , Esgotos
9.
J Environ Manage ; 298: 113456, 2021 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-34364246

RESUMO

Sludge treatment is an integral part of faecal sludge management in non-sewered sanitation settings. Development of pyrolysis as a suitable sludge treatment method requires thorough knowledge about the properties and thermal decomposition mechanisms of the feedstock. This study aimed to improve the current lack of understanding concerning relevant sludge properties and their influence on the thermal decomposition characteristics. Major organic compounds (hemicellulose, cellulose, lignin, protein, oil and grease, other carbohydrates) were quantified in 30 faecal sludge samples taken from different sanitation technologies, providing the most comprehensive organic faecal sludge data set to date. This information was used to predict the sludge properties crucial to pyrolysis (calorific value, fixed carbon, volatile matter, carbon, hydrogen). Samples were then subjected to thermogravimetric analysis to delineate the influence of organic composition on thermal decomposition. Septic tanks showed lower median fractions of lignin (9.4%dwb) but higher oil and grease (10.7%dwb), compared with ventilated improved pit latrines (17.4%dwb and 4.6%dwb respectively) and urine diverting dry toilets (17.9%dwb and 4.7%dwb respectively). High fixed carbon fractions in lignin (45.1%dwb) and protein (18.8%dwb) suggested their importance for char formation, while oil and grease fully volatilised. For the first time, this study provided mechanistic insights into faecal sludge pyrolysis as a function of temperature and feedstock composition. Classification into the following three phases was proposed: decomposition of hemicellulose, cellulose, other carbohydrates, proteins and, partially, lignin (200-380 °C), continued decomposition of lignin and thermal cracking of oil and grease (380-500 °C) and continued carbonisation (>500 °C). The findings will facilitate the development and optimisation of faecal sludge pyrolysis, emphasising the importance of considering the organic composition of the feedstock.


Assuntos
Pirólise , Esgotos , Fezes , Saneamento , Banheiros
10.
J Appl Microbiol ; 128(4): 1208-1220, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31846171

RESUMO

AIM: Infiltration experiments aimed to show the effectivity of coral sand to remove micro-organisms in septic tank wastewater treatment system, in South Tarawa, Kiribati. METHODS AND RESULTS: Laboratory experiments evaluated effective microbial removal properties of a packed bed of coral beach sand conditioned with domestic effluent. Bacterial and viral indicators Escherichia coli J6-2, Enterococci faecalis and f-RNA (MS2) bacteriophage, along with viral pathogens adenovirus, echovirus, norovirus and rotavirus, were dosed (at 106 -107  CFU, PFU or genome copies per ml concentration) with effluent to unsaturated coral sand-packed columns. For the conditions simulated, all organisms showed removal efficiencies of >4-Log Removal Values (LRVs) (i.e. >99·99% effective reduction in number). Results revealed that the conditioned coral sand had a higher affinity for attenuating viruses than the bacteria tested. MS2 phage, adenovirus, echovirus, norovirus and rotavirus were absent in leachate from the base of the sand columns. E. coli J6-2 and E. faecalis were recovered at 100 -101  CFU (colony forming units) per ml in the column effluent, following a dosage of 106  CFU per ml. Destructive sampling of the columns after experiments revealed that a high proportion of viral pathogens were retained in the top 30 mm of the sand. CONCLUSIONS: On the basis of the relative spatial distribution of trace organisms in the sand, we speculate that adsorption processes likely dominated attenuation of the viral pathogens, more so than physical straining effects. Further study is required to fully elucidate the removal mechanisms. SIGNIFICANCE AND IMPACT OF THE STUDY: To the best of our knowledge this is the first study of the effective microbial removal capacity of coral sand under unsaturated conditions. The work represents an initial exploratory step of developing some standardized design practice of on-site wastewater treatment systems in Kiribati, to offer enhanced protection of groundwater resources and reduce diarrhoeal disease.


Assuntos
Antozoários/química , Areia/química , Eliminação de Resíduos Líquidos/métodos , Poluentes da Água/isolamento & purificação , Purificação da Água/métodos , Adsorção , Animais , Bactérias/isolamento & purificação , Bactérias/patogenicidade , Micronésia , Vírus/isolamento & purificação , Vírus/patogenicidade
11.
J Environ Manage ; 260: 110134, 2020 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-32090830

RESUMO

Attached-growth photobioreactors (AG-PBRs) employing low-cost attached-growth media were applied to treat septic tank effluent which contained abundant organic and nutrient matters as well as pathogenic microorganisms. This study investigated effects of blue and red LED lights on organic, nutrient and pathogenic removals, biomass productivity and compositions of microbial community in the AG-PBR system. The experimental results showed the blue AG-PBR to be more effective in removing chemical oxygen demand (COD), total nitrogen (TN) and ammonia nitrogen (NH3-N) and generating biomass productivity than those of the red AG-PBR (P < 0.05). Mass balance analysis indicated that the TN and total phosphorus (TP) were removed mainly by assimilation into the biomass. The TN removal rates via nitrification and denitrification processes in the blue AG-PBR were found to be higher than that of the red AG-PBR, corresponding to the observed results of bacterial biomass and abundances of nitrifying and denitrifying bacterial species in the treatment systems. The maximal areal algal biomass productivity of 47 gDW/(m2. d) in the blue AG-PBRs was found to be higher than those of other algal attached-growth systems. Although, the red and blue AG-PBR systems could effectively treat the septic tank effluent to meet the national and international discharge standards, based on treatment efficiencies and biomass productivity, the blue AG-PBR is recommended for treatment of septic tank effluent.


Assuntos
Fósforo , Fotobiorreatores , Biomassa , Veículos Automotores , Nitrificação , Nitrogênio
12.
J Environ Manage ; 251: 109552, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31557672

RESUMO

Structure and performance of a newly designed four-chamber septic tank were investigated in current study. A three-layer orifice plate was fitted in the first compartment in an upward direction, and a baffle was arranged in the second compartment of the septic tank. The filter placed in the third and fourth compartment was used to collect water for field irrigation or connect subsequent devices for further processing. Flow field distribution in the first chamber was numerically simulated by Fluent software, and simulation results were verified by residence time distribution tracer experiment. The improved treatment effects of the modified septic tank with optimal parameters of 20 mm (diameter), 60 mm (gap) and 180 mm (distance) were validated by simulation experiments. High removal rates of chemical and biological oxygen demand reflected the effectiveness of modified septic tanks.


Assuntos
Esgotos , Purificação da Água , Análise da Demanda Biológica de Oxigênio , Eliminação de Resíduos Líquidos , Água
13.
Waste Manag Res ; 37(12): 1199-1206, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31607233

RESUMO

Septic systems are typically designed to treat domestic wastewater from households without access to centralized facilities. The installation of a food waste disposer (FWD) may increase the discharge of food waste (FW) into the wastewater; therefore, the installation of a FWD is discouraged in households that have a septic system. This study was conducted to determine how a typical dose of FW from a FWD can affect the performance of a septic system in terms of sewage treatment and solids accumulation. A 20-L control tank was compared with an experiment tank to which FW was added, increasing the amount of total suspended solids (TSS) by 31.3% and total chemical oxygen demands by 46.3% for a period of 110 days. Although the influent water quality changed dramatically, the effluent from the experiment tank had a substantially lower percentage increase in water quality parameters compared with the effluent from the control. It was found that in the experiment tank, 75.8% of FW TSS was degraded, whereas only 36.7% of sewage TSS was degraded, and that 18.8% of FW TSS and 44.9% of sewage TSS accumulated in the experiment tank. The addition of FW increased the scum accumulation, even though the dry matter of the scum layer was much less in quantity than the sludge layer. It also increased the lipid content in the sludge. The increase in the scum layer was mainly due to the increase in protein from the addition of the FW. Overall, compared with sewage TSS, FW TSS tends to be more biodegradable, which indicates that the impact on pumping frequency from adding FW will be insignificant.


Assuntos
Alimentos , Eliminação de Resíduos , Análise da Demanda Biológica de Oxigênio , Reatores Biológicos , Esgotos , Eliminação de Resíduos Líquidos , Águas Residuárias
14.
J Environ Manage ; 170: 15-20, 2016 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-26775157

RESUMO

13 million people (about 20% of the population) use on-site wastewater treatment in France. Buried vertical sand filters are often built, especially when the soil permeability is not sufficient for septic tank effluent infiltration in undisturbed soil. Clogging is one of the main problems deteriorating the operation of vertical flow filters for wastewater treatment. The extent of clogging is not easily assessed, especially in buried vertical flow sand filters. We suggest examining two possible ways of detecting early clogging: (1) NH4-N/NO3-N outlet concentration ratio, and (2) oxygen measurement within the porous media. Two pilot-scale filters were equipped with probes for oxygen concentration measurements and samples were taken at different depths for pollutant characterization. Influent and effluent grab-samples were taken three times a week. The systems were operated using batch-feeding of septic tank effluent. Qualitative description of oxygen transfer processes under unclogged and clogged conditions is presented. NH4-N outlet concentration appears to be useless for early clogging detection. However, NO3-N outlet concentration and oxygen content allows us to diagnose the early clogging of the system.


Assuntos
Filtração/instrumentação , Nitrogênio/química , Oxigênio/química , Águas Residuárias , Filtração/métodos , França , Humanos , Dióxido de Silício/química
15.
J Environ Manage ; 153: 33-9, 2015 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-25646674

RESUMO

Three new baffle flow constructed wetlands (CWs), namely the baffle horizontal flow CW (Z1), baffle vertical flow CW (Z2) and baffle hybrid flow CW (Z3), along with one traditional horizontal subsurface flow CW (Z4) were designed to test the removal efficiency of nitrogen (N) and phosphorus (P) from the septic tank effluent under varying hydraulic retention times (HRTs). Results showed that the optimal HRT was two days for maximal removal of N and P from the septic tank effluent among the four CWs. At this HRT, the Z1, Z2, Z3 and Z4 CWs removed, respectively, 49.93, 58.50, 46.01 and 44.44% of TN as well as 87.82, 93.23, 95.97 and 91.30% of TP. Our study further revealed that the Z3 CW was the best design for overall removal of N and P from the septic tank effluent due to its hybrid flow directions with better oxygen supply inside the CW system.


Assuntos
Esgotos/análise , Eliminação de Resíduos Líquidos/métodos , Poluentes Químicos da Água/metabolismo , Áreas Alagadas , Zingiberales/metabolismo , Nitrogênio/metabolismo , Fósforo/metabolismo
16.
Environ Pollut ; 341: 122884, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37951526

RESUMO

Identifying the origin of faecal pollution in water is needed for effective water management decisions to protect both human health and aquatic ecosystems. Traditionally used indicators of faecal contamination, such as E. coli, only indicate pollution from warm-blooded animals and not the specific source of contamination; hence, more source specific tracers are required. The study has focussed on separating the two main sources of contaminants within rural catchments in Ireland, agriculture and on-site wastewater treatment systems (predominantly septic tanks). While human-specific effluent tracers may assist in identifying potential pathways from individual septic tanks to surface waters, it is difficult to quantify the cumulative impact of such systems at a catchment scale. This study has investigated faecal sterols as a method to quantify such an impact on four small catchments in areas of low subsoil permeability with high densities of septic tanks. The results demonstrate the usefulness of faecal sterols which provide a quantitative evaluation of the respective impact between agricultural pasture inputs and on-site effluent showing differences between the four catchments. The study also highlights the need to derive more specific local reference sterol profile databases for specific countries or regions, using local source material of animal faeces and effluent. Two intensive sampling campaigns on the four catchments then used faecal sterols in parallel to fluorescent whitening compounds (FWCs), caffeine, artificial sweeteners and selected pharmaceuticals to gain further insights and confirmation about contamination hotspots as well as providing comparison between the different parameters. The combination of sterols, FWCs, caffeine, acesulfame and cyclamate has proven suitable to provide an estimate of the extent of human contamination in these rural catchments and has yielded additional information about potential pollution pathways and proximity of contamination. Overall, this methodology can help to facilitate a targeted and effective water management in such catchments.


Assuntos
Escherichia coli , Esteróis , Animais , Humanos , Esteróis/análise , Cafeína , Ecossistema , Fezes/química , Água , Monitoramento Ambiental/métodos
17.
Environ Pollut ; 356: 124248, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38810674

RESUMO

Non-sewered sanitation systems (NSSS) are identified as significant contributors of greenhouse gases (GHGs), primarily due to biological processes occurring within the containment systems. In unsealed or unlined containment systems like pit latrines, the emissions are influenced by moisture. This work quantified the GHG emission from unlined or unsealed containments prevalent in Nepal and compared it with sealed containment-like septic tanks, where the chances of groundwater (GW) inundation are low. The modeled GW data extracted from the secondary sources were validated with available national data. The emissions were quantified using the Intergovernmental Panel for Climate Change (IPCC) model for different ecological and provincial divisions of Nepal. Spatial representation for the results was done using the Geographical Information System (GIS) tool. The total methane (CH4) emission occurring from the various NSSS was determined to be 2618 Gg CO2 e per year which is almost twice the emission from the waste sector in 2011, as reported by the recent national communication submitted to the United Nations Framework Convention on Climate Change (UNFCC). Variation of the CH4 emission was found to be prominent in lowlands (Terai region) with total national emissions of 1329.37 Gg CO2e per year. The lowland has a shallow GW table that can easily inundate the unlined containments like pit latrines thus contributing to more anaerobic conditions which may lead to higher CH4 emissions compared to containments in mid and highlands. This study concludes that the GHG emissions occurring from NSSS are substantial and addressing these emissions can help fulfil the Nationally Determined Contributions (NDCs) in the waste sector.

18.
Heliyon ; 9(11): e21209, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37885722

RESUMO

Pit latrines are the most common form of improved sanitation in many rapidly developing countries. However, they cause the highest amount of groundwater pollution among on-site sanitation (OSS) facilities. Many households in developing countries use groundwater as their main or sub-source, and pit latrines are not a sustainable solution. Thus, the conversion from pit latrines to septic tanks is required. We created two types of media, still images and a video, to illustrate the differences in functions and hygiene risks between pit latrines and septic tanks. Moreover, a survey was conducted in Sri Lanka to determine the media choice that would increase the people's preference for septic tanks as their next OSS, even weeks after the information is presented. The choice of the next OSS participants selected before they were presented with the images was the same as that currently in use, reflecting the belief that the problem of pit latrines was not currently apparent and need not be changed. However, a video presentation of the information made it possible for a larger group of people to choose the usage of septic tanks in the future, especially in suburban areas where the problems were likely to occur.

19.
Water Res ; 236: 119968, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37062234

RESUMO

The suitability of a location for an on-site wastewater treatment process (for areas which lack access to centralised wastewater treatment systems) requires an assessment of the permeability of the soil into which the effluent will be discharged. In many jurisdictions this is determined using some type of in-situ percolation test. Falling head percolation tests, which give a value of percolation time (PT) that is empirically related to the notion of hydraulic conductivity, are widely used as they are relatively simple to carry out, but the test does not have a sound theoretical framework and test methods are not standardised internationally. In comparison, the saturated hydraulic conductivity of a soil obtained from a constant head well permeameter test is independent of test conditions, and so is a more suitable metric for design. A database of over 900 falling head tests carried out across a range of different subsoil types in Ireland has been collated, all with the inherent limitations of the existing regulative framework regarding the percolation test and soil texture assessment. These tests were then modelled using Hydrus 2-D numerical modelling simulations to determine equivalent field saturated hydraulic conductivity (Kfs) values and thereby provide a correlation with PT values across the range of subsoil conditions. In addition, falling head tests have been carried out in parallel to constant head permeameter tests in the field and compared against the relationship derived from the broad dataset of simulated results. This revealed an optimal solution by which to determine Kfs from the field permeameter test (using parameters recommended for most structured soils from clays to loams). The trendline based on Irish data was also compared against more generic formulations of the relationship between PT, and Kfs and shown to match closely, particularly the Reynolds (2016) 'unified' methodology. Finally, the Irish threshold PT limits for on-site wastewater treatment have been converted to Kfs values and compared against other international standards.


Assuntos
Águas Residuárias , Argila , Solo , Movimentos da Água
20.
Water Res ; 226: 119293, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36323216

RESUMO

Microplastics (MPs) are emerging pollutants that have been widely detected in the atmosphere, hydrosphere, lithosphere, and biosphere. Such wide spread of MPs indicates that the effective control in different environmental sectors is in an urgent need, and the first step in meeting this need is to identify the occurrence of MPs in the relevant environment. However, research on MPs in septic tanks has not been reported so far. This study investigated the distribution characteristics of MPs in septic tanks with a size detection limit of as low as 20 µm detected by laser direct infrared spectroscopy. Results showed that the number of MPs in the septic tank was reached 2803 (1489-4816) particles/g dry sludge, and the amount detected in the sediments was one order of magnitude higher than that in the scums. A total of 36 types of MPs were found in the septic tank, and 26 types were found in both sediments and scums, but the type in the scums was 21% higher than that in the sediments. The size was mostly 20-100 µm, accounting for 86.3% and 91.2% in the sediments and scums, respectively. Four shapes of MPs were detected in the septic tank, namely, fiber, bead, granule, and fragment. Our study revealed that septic tanks are both sinks and sources of MPs, which are reflected in the fact that MPs are not only large in number but also abundant in types. Thus, significant attention should be paid to septic tank-based microplastic pollution, which may lead to environmental and health risks without proper control and management.


Assuntos
Microplásticos , Poluentes Químicos da Água , Plásticos/química , Sedimentos Geológicos/química , Monitoramento Ambiental , Poluentes Químicos da Água/análise , Análise Espectral , Lasers
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA