1.
Materials (Basel) ; 16(17)2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37687716

RESUMO

As a transfer member at the discontinuous place of vertical load, the deep beam has a complex stress mechanism and many influencing factors, such as compressive strength of concrete, shear span ratio, and reinforcement ratio. At the same time, the stress analysis principle of traditional shallow beams is no longer applicable to the design and calculation of deep-beam structure. The main purpose of this paper was to use the strut-and-tie model to analyze its stress mechanism, and to verify the applicability of the model. Nine high-strength concrete deep-beam specimens with longitudinal reinforcement with an anchor plate of the same size were tested by two-point concentrated loading method. The effects of shear span ratio (0.3, 0.6, and 0.9), longitudinal reinforcement ratio (0.67%, 1.05%, and 1.25%), horizontal reinforcement ratio (0.33%, 0.45%, and 0.50%), and stirrup reinforcement ratio (0.25%, 0.33%, and 0.50%) on the failure mode, deflection curve, characteristic load, crack width, steel bar, and concrete strain of the specimens were analyzed. The results showed that the failure mode of deep-beam specimens was diagonal compression failure. The normal section cracking load was about 15 to 20% of the ultimate load, and the inclined section cracking load was about 30~40% of the ultimate load. The shear span ratio increased from 0.3 to 0.9, and the bearing capacity decreased by 32.9%. When the longitudinal reinforcement ratio increased from 0.67% to 1.25%, the ultimate load increased by 42.6%. The shear span ratio and longitudinal reinforcement ratio have a significant effect on the bearing capacity of the high-strength concrete deep beams with longitudinal reinforcement with an anchor plate. The shear capacity of nine high-strength concrete deep-beam specimens with longitudinal reinforcement with an anchor plate was calculated by national standards, and the results were compared with the calculation results of the Tan-Tang model, the Tan-Cheng model, SSTM, and SSSTM. The analysis showed that the softened strut-and-tie model takes into account the softening effect of compressive concrete, and is a more accurate mechanical model, which can be applied to predict the shear capacity of high-strength concrete deep-beam members with longitudinal reinforcement with an anchor plate.

2.
Materials (Basel) ; 13(3)2020 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-32041205

RESUMO

To study the seismic performance of embedded polyvinyl chloride (PVC) pipe confined reinforced high-strength concrete (PVC-RHC) columns, five specimens are designed for cyclic loading test, which include three PVC-RHC column specimens, an embedded circle steel tube confined reinforced high-strength concrete (CST-RHC) column specimen, and a reinforced high-strength concrete (RHC) column specimen. The failure mechanism and morphology are revealed by experiments. The influences of PVC pipe diameter, axial compression ratio, and concrete strength on seismic performance indexes are analyzed. The research results indicate thhe following: all specimens displayed shear baroclinic failure. Compared with RHC specimens, the hysteretic curves of the PVC-RHC specimen and CST-RHC specimen were fuller; furthermore, their energy dissipation capacity, deformation, and ductility were more beneficial. With the increase of the diameter-length ratio and axial pressure, the energy dissipation capacity and deformation capacity of PVC-RHC specimens decreased. The shear bearing capacity of the PVC-RHC specimen calculated with "concrete structure design code" (GB 50010-2010) was smaller than the test results by 25%, showing an excessive safety margin. Thus, according to the failure mechanism of the PVC-RHC specimen, a new calculation formula of shear bearing capacity is deduced, which is in good agreement with the experimental results.

3.
Materials (Basel) ; 12(18)2019 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-31547280

RESUMO

The high-strength bolt shear connector in prefabricated concrete slab has advantages in applications as it reduces time during the construction of steel-concrete composite building structures and bridges. In this research, an innovative and advanced bolt shear connector in steel-concrete composite structures is proposed. To investigate the fundamental mechanical behavior and the damage form, 22 static push-off tests were conducted with consideration of different bolt dimensions, the reserved hole constraint condition, and the dimension of slab holes. A finite element (FE) model was established and verified by using test results, and then the model was utilized to investigate the influence of concrete strength, bolt dimension, yield strength, bolt pretension, as well as length-to-diameter ratio of high strength bolts on the performances of shear connectors. On the basis of FE simulation and test results, new design formulas for the calculation of shear resistance behavior were proposed, and comparisons were made with current standards, including AISC, EN 1994-1-1, GB 50017-2017, and relevant references, to check the calculation efficiency. It is confirmed that the proposed equation is in better agreement with the experimental results.