Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Ultrasound Obstet Gynecol ; 61(6): 758-764, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36864543

RESUMO

OBJECTIVES: To compare short-term variation (STV) outputs from a novel self-applied non-invasive fetal electrocardiography (NIFECG) device with those obtained on computerized cardiotocography (cCTG). Technological and algorithmic limitations and mitigation strategies were also evaluated. METHODS: This was a prospective cohort study of women with a singleton pregnancy over 28 + 0 weeks' gestation attending a tertiary London hospital for cCTG assessment between June 2021 and June 2022. Women underwent concurrent monitoring with both NIFECG and cCTG for up to 1 h. Postprocessing of NIFECG data using various filtering methods produced NIFECG-STV (eSTV) values, which were compared with cCTG-STV (cSTV) outputs. Linear correlation, mean bias, precision and limits of agreement were assessed for STV derived by the different methods of computation and mathematical correction. RESULTS: Overall, 306 concurrent NIFECG and cCTG traces were collected from 285 women. Fully filtered eSTV was correlated very strongly with cSTV (r = 0.911, P < 0.001), but generated results only in 142/306 (46.4%) 1-h traces owing to the removal of traces with lower-quality signals. Partial filtering generated more eSTV data (98.4%), but with a weak correlation with cSTV (r = 0.337, P < 0.001). The difference in STV between the monitors (eSTV - cSTV) increased with signal loss; in traces with > 60% signal loss, the values became highly discrepant. Removal of traces with > 60% signal loss resulted in a stronger correlation with cSTV, while still generating eSTV results for 65% of traces. Correcting these remaining eSTV values for signal loss using linear regression analysis further improved correlation with cSTV (r = 0.839, P < 0.001). CONCLUSIONS: The discrepancy between STV computed by NIFECG and cCTG necessitates signal filtering, exclusion of poor-quality traces and eSTV correction. This study demonstrates that, with such correction, NIFECG is able to produce STV values that are strongly correlated with those of cCTG. This evidence base for NIFECG monitoring and interpretation is a promising step forward in the development of safe and effective at-home fetal heart-rate monitoring. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Cardiotocografia , Monitorização Fetal , Gravidez , Humanos , Feminino , Cardiotocografia/métodos , Estudos Prospectivos , Feto , Eletrocardiografia , Frequência Cardíaca Fetal
2.
Ultrasound Obstet Gynecol ; 61(6): 765-772, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36864541

RESUMO

OBJECTIVES: To establish the correlation between phase-rectified signal averaging (PRSA) outputs obtained from a novel self-applicable non-invasive fetal electrocardiography (NIFECG) monitor with those from computerized cardiotocography (cCTG). A secondary objective was to evaluate the potential for remote assessment of fetal wellbeing by determining the relationship between PRSA and short-term variation (STV). METHODS: This was a prospective observational study of women with a singleton pregnancy over 28 + 0 weeks' gestation attending a London teaching hospital for cCTG assessment. Participants underwent concurrent cCTG and NIFECG monitoring for up to 60 min. Averaged accelerative (AAC) and decelerative (ADC) capacities and STV were derived by postprocessing and filtration of signals, generating fully (F) and partially (P) filtered results. Linear correlation and accuracy and precision analysis were performed to assess the relationship between PRSA outputs from cCTG and NIFECG, using varying anchor thresholds, and their association with STV. RESULTS: A total of 306 concurrent cCTG and NIFECG traces were collected from 285 women. F-filtered NIFECG PRSA (eAAC/eADC) results were generated from 65% of traces, whereas cCTG PRSA (cAAC/cADC) outputs were generated from all. Strong correlations were observed between cAAC and F-filtered eAAC (r = 0.879, P < 0.001) and between cADC and F-filtered eADC (r = 0.895, P < 0.001). NIFECG anchor detection decreased significantly with increasing signal loss, and NIFECG PRSA indices showed considerable deviation from those of cCTG when derived from traces in which fewer than 100 anchors were detected. Removing anchor filters from NIFECG traces to generate P-filtered PRSA outputs weakened the correlation (AAC: r = 0.505, P < 0.001; ADC: r = 0.560, P < 0.001). Lowering the anchor threshold to 100 increased the yield of eAAC and eADC outputs to approximately 74%, whilst maintaining strong correlation with cAAC (r = 0.839, P < 0.001) and cADC (r = 0.815, P < 0.001), respectively. Both cAAC and cADC showed a very strong linear relationship with cCTG STV (r = 0.928, P < 0.001 and r = 0.911, P < 0.001, respectively). Similar findings were observed with eAAC (r = 0.825, P < 0.001) and eADC (r = 0.827, P < 0.001). CONCLUSIONS: PRSA appears to be a method of fetal assessment equivalent to STV, but, due to its innate ability to eliminate artifacts, it generates interpretable NIFECG traces with high accuracy at a higher rate. These findings raise the possibility of self-applied at-home or remote fetal heart-rate monitoring with automated reporting, thus enabling increased surveillance in high-risk women without impacting on service demand. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Monitorização Fetal , Frequência Cardíaca Fetal , Gravidez , Humanos , Feminino , Frequência Cardíaca Fetal/fisiologia , Cardiotocografia/métodos , Estudos Prospectivos , Cuidado Pré-Natal
3.
J Perinat Med ; 51(5): 634-640, 2023 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-36441559

RESUMO

OBJECTIVES: To compare short term variation (STV) and phase rectified signal averaging (PRSA) and their association with fetal outcome in early onset fetal growth restriction (FGR). METHODS: Data were used from a retrospective cohort study of women who were admitted for FGR and/or pre-eclampsia and who were delivered by pre-labor Cesarean section or had a fetal death before 32 weeks' gestation. Computerized cardiotocography (cCTG) registrations of the 5 days before delivery or fetal death were used for calculation of STV and PRSA. PRSA was expressed as the average acceleration capacity (AAC) and average deceleration capacity (ADC). FHR decelerations were classified visually as absent, 1-2 per hour or recurrent. Abnormality of STV and of PRSA was either analyzed as a single parameter or in combination with recurrent decelerations. Endpoints were defined as composite adverse condition at birth consisting of fetal death, low Apgar score, low umbilical pH, the need for resuscitation after birth and as major neonatal morbidity or neonatal death. RESULTS: Included were 367 pregnancies of which 20 resulted in fetal death. An abnormal cCTG with either recurrent decelerations and/or low STV or recurrent decelerations and/or low PRSA were similarly associated with composite adverse condition at birth (n=99), but neither with major neonatal morbidity. CONCLUSIONS: PRSA and STV have similar efficacy for measuring fetal heart rate variation in early onset FGR. An increased risk of a composite adverse condition at birth is indicated by a low value of either parameter and/or the presence of recurrent decelerations.


Assuntos
Cesárea , Retardo do Crescimento Fetal , Recém-Nascido , Gravidez , Humanos , Feminino , Retardo do Crescimento Fetal/diagnóstico , Estudos Retrospectivos , Cardiotocografia/métodos , Morte Fetal , Frequência Cardíaca Fetal/fisiologia
4.
Am J Obstet Gynecol ; 226(3): 366-378, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35026129

RESUMO

This study reviewed the literature about the diagnosis, antepartum surveillance, and time of delivery of fetuses suspected to be small for gestational age or growth restricted. Several guidelines have been issued by major professional organizations, including the International Society of Ultrasound in Obstetrics and Gynecology and the Society for Maternal-Fetal Medicine. The differences in recommendations, in particular about Doppler velocimetry of the ductus venosus and middle cerebral artery, have created confusion among clinicians, and this review has intended to clarify and highlight the available evidence that is pertinent to clinical management. A fetus who is small for gestational age is frequently defined as one with an estimated fetal weight of <10th percentile. This condition has been considered syndromic and has been frequently attributed to fetal growth restriction, a constitutionally small fetus, congenital infections, chromosomal abnormalities, or genetic conditions. Small for gestational age is not synonymous with fetal growth restriction, which is defined by deceleration of fetal growth determined by a change in fetal growth velocity. An abnormal umbilical artery Doppler pulsatility index reflects an increased impedance to flow in the umbilical circulation and is considered to be an indicator of placental disease. The combined finding of an estimated fetal weight of <10th percentile and abnormal umbilical artery Doppler velocimetry has been widely accepted as indicative of fetal growth restriction. Clinical studies have shown that the gestational age at diagnosis can be used to subclassify suspected fetal growth restriction into early and late, depending on whether the condition is diagnosed before or after 32 weeks of gestation. The early type is associated with umbilical artery Doppler abnormalities, whereas the late type is often associated with a low pulsatility index in the middle cerebral artery. A large randomized clinical trial indicated that in the context of early suspected fetal growth restriction, the combination of computerized cardiotocography and fetal ductus venosus Doppler improves outcomes, such that 95% of surviving infants have a normal neurodevelopmental outcome at 2 years of age. A low middle cerebral artery pulsatility index is associated with an adverse perinatal outcome in late fetal growth restriction; however, there is no evidence supporting its use to determine the time of delivery. Nonetheless, an abnormality in middle cerebral artery Doppler could be valuable to increase the surveillance of the fetus at risk. We propose that fetal size, growth rate, uteroplacental Doppler indices, cardiotocography, and maternal conditions (ie, hypertension) according to gestational age are important factors in optimizing the outcome of suspected fetal growth restriction.


Assuntos
Retardo do Crescimento Fetal , Peso Fetal , Feminino , Retardo do Crescimento Fetal/diagnóstico por imagem , Retardo do Crescimento Fetal/terapia , Idade Gestacional , Humanos , Lactente , Placenta , Gravidez , Ensaios Clínicos Controlados Aleatórios como Assunto , Ultrassonografia Doppler , Ultrassonografia Pré-Natal , Artérias Umbilicais/diagnóstico por imagem
5.
Environ Sci Technol ; 56(12): 7905-7916, 2022 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35584234

RESUMO

Human exposure to per- and polyfluoroalkyl substances (PFASs) has gained worldwide attention due to their widespread presence in the environment and adverse health effects, but the exposure assessment in the elderly is still lacking. This study aimed to assess exposures to 3 emerging PFASs (chlorinated polyfluoroalkyl ether sulfonic acids, Cl-PFESAs) and 15 legacy PFASs. The temporal variability of internal exposures and intake amounts of these PFASs were evaluated among a population of 76 healthy elderly adults (age: 60-69) in Jinan, China over 5 consecutive months. Fifteen PFASs were detected in whole blood with the mean total concentration (ΣPFAS) at 20.1 ng/mL (range: 5.0-135.9 ng/mL) dominated by perfluorooctanoic acid (PFOA) (9.0 ng/mL), perfluorooctanesulfonic acid (PFOS) (5.3 ng/mL), and 6:2 Cl-PFESA (1.6 ng/mL). Across the 5 month assessment period, significant variation was only observed for short-chain (C4-C7) perfluoroalkyl carboxylic acids, and their variations ranged from 53 to 334%. The median intake of PFOA and PFOS was estimated to be 1.46 and 0.92 ng/kg bw/day, respectively. Regression analysis showed that dietary ingestion, especially fish, was likely an important exposure pathway for PFASs among the elderly adults. Various pathways (e.g., dietary, water, air, and dust) should thus be considered to fully understand human exposure to PFASs.


Assuntos
Ácidos Alcanossulfônicos , Fluorocarbonos , Adulto , Idoso , Ácidos Alcanossulfônicos/análise , Animais , China , Poeira/análise , Éteres/análise , Fluorocarbonos/análise , Humanos , Pessoa de Meia-Idade , Ácidos Sulfônicos/análise
6.
Ultrasound Obstet Gynecol ; 57(1): 70-74, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33030756

RESUMO

OBJECTIVE: To evaluate the feasibility of using umbilical artery (UA) Doppler waveforms to measure fetal heart rate (FHR) short-term variation (STV) across gestation. METHODS: This was a prospective longitudinal study, conducted at two study sites, of 195 pregnancies considered low risk. Pulsed-wave Doppler of the UAs was performed at 4-weekly intervals, between 14 and 40 weeks of gestation, using a standardized imaging protocol. Up to 12 consecutive UA Doppler waveforms were analyzed using offline processing software. FHR STV was calculated using average R-R intervals extracted from the waveforms and baseline corrected for FHR. RESULTS: Baseline-corrected FHR STV increased significantly with gestational age (conditional R2 = 0.37; P < 0.0001) and was correlated inversely with FHR (conditional R2 = 0.54; P < 0.0001). The STV ranged (median (interquartile range)) from 3.5 (2.9-4.1) ms at 14-20 weeks' gestation to 6.3 (4.8-7.7) ms at 34-40 weeks' gestation. The change in heart rate STV did not differ between study sites or individual sonographers. CONCLUSIONS: UA Doppler waveforms offer a robust and feasible method to derive STV of the FHR. It should be emphasized that the UA Doppler-derived STV is not interchangeable with measurements derived with computerized cardiotocography. Accordingly, further investigations are needed to validate associations with outcome, in order to determine the value of concurrent fetal cardiovascular and heart rate evaluations that are possible with the technique described here. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Retardo do Crescimento Fetal/diagnóstico por imagem , Frequência Cardíaca Fetal , Artéria Cerebral Média/diagnóstico por imagem , Ultrassonografia Doppler/métodos , Artérias Umbilicais/diagnóstico por imagem , Adulto , Cardiotocografia/métodos , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Estudos Longitudinais , Masculino , Artéria Cerebral Média/embriologia , Gravidez , Estudos Prospectivos , Ultrassonografia Pré-Natal
7.
Ultrasound Obstet Gynecol ; 55(1): 68-74, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31125465

RESUMO

OBJECTIVE: To explore the effect on perinatal outcome of different fetal monitoring strategies for early-onset fetal growth restriction (FGR). METHODS: This was a cohort analysis of individual participant data from two European multicenter trials of fetal monitoring methods for FGR: the Growth Restriction Intervention Study (GRIT) and the Trial of Umbilical and Fetal Flow in Europe (TRUFFLE). All women from GRIT (n = 238) and TRUFFLE (n = 503) who were randomized between 26 and 32 weeks' gestation were included. The women were grouped according to intervention and monitoring method: immediate delivery (GRIT) or delayed delivery with monitoring by conventional cardiotocography (CTG) (GRIT), computerized CTG (cCTG) only (GRIT and TRUFFLE) or cCTG and ductus venosus (DV) Doppler (TRUFFLE). The primary outcome was survival without neurodevelopmental impairment at 2 years of age. RESULTS: Gestational age at delivery and birth weight were similar in both studies. Fetal death rate was similar between the GRIT and TRUFFLE groups, but neonatal and late death were more frequent in GRIT (18% vs 6%; P < 0.01). The rate of survival without impairment at 2 years was lowest in pregnancies that underwent immediate delivery (70% (95% CI, 61-78%)) or delayed delivery with monitoring by CTG (69% (95% CI, 57-82%)), increased in those monitored using cCTG only in both GRIT (80% (95% CI, 68-91%)) and TRUFFLE (77% (95% CI, 70-84%)), and was highest in pregnancies monitored using cCTG and DV Doppler (84% (95% CI, 80-89%)) (P < 0.01 for trend). CONCLUSIONS: This analysis supports the hypothesis that the optimal method for fetal monitoring in pregnancies complicated by early-onset FGR is a combination of cCTG and DV Doppler assessment. TRIAL REGISTRATION: GRIT ISRCTN41358726 and TRUFFLE ISRCTN56204499. © 2019 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.


Análisis comparativo de los resultados a los 2 años de edad en los ensayos GRIT y TRUFFLE OBJETIVO: Examinar el efecto sobre el resultado perinatal de diferentes estrategias de monitoreo del feto para la restricción del crecimiento fetal (RCF) de inicio precoz. MÉTODOS: Este estudio realizó un análisis de cohortes de datos de participantes individuales en dos ensayos multicéntricos europeos de métodos de monitoreo fetal para la RCF: el Estudio de Intervención en la Restricción del Crecimiento (GRIT, por sus siglas en inglés) y el Ensayo Europeo de Flujo Umbilical y Fetal (TRUFFLE, por sus siglas en inglés). Se incluyeron todas las mujeres de GRIT (n = 238) y de TRUFFLE (n = 503) que habían sido asignadas al azar entre 26 y 32 semanas de gestación. Las mujeres se agruparon según el método de intervención y monitoreo: parto inmediato (GRIT) o parto diferido con monitoreo mediante cardiotocografía convencional (CTG) (GRIT), solo CTG digital (cCTG, por sus siglas en inglés) (GRIT y TRUFFLE) o cCTG y Doppler del conducto de Arancio (DV) (TRUFFLE). La medida de resultado primaria fue la supervivencia sin deterioro del desarrollo neurológico a los dos años de edad. RESULTADOS: La edad gestacional al momento del parto y el peso al nacer fueron similares en ambos estudios. La tasa de mortalidad fetal fue similar entre los grupos de GRIT y TRUFFLE, pero la muerte neonatal y tardía fue más frecuente en el grupo de GRIT (18% vs 6%; P < 0,01). La tasa de supervivencia sin deterioro a los dos años fue más baja en los embarazos que se sometieron a un parto inmediato (70% (IC 95%, 61-78%)) o a un parto tardío con monitoreo mediante CTG (69% (IC 95%, 57-82%)), más alta en los monitoreados solo mediante cCTG en GRIT (80% (IC 95%, 68-91%)) y TRUFFLE (77% (IC 95%, 70-84%)), y mayor aun en los embarazos monitoreados mediante cCTG y Doppler DV (84% (IC 95%, 80-89%)) (P < 0,01 para tendencia). CONCLUSIONES: Este análisis apoya la hipótesis de que el método óptimo para el monitoreo fetal en los embarazos complicados por RCF de inicio precoz es una combinación de cCTG y evaluación Doppler DV. INSCRIPCIÓN DEL ENSAYO: GRIT ISRCTN41358726 y TRUFFLE ISRCTN56204499. © 2019 Los autores. Ultrasonido en Obstetricia y Ginecología publicado por John Wiley & Sons Ltd. en nombre de la Sociedad Internacional de Ultrasonido en Obstetricia y Ginecología.


Assuntos
Cardiotocografia , Retardo do Crescimento Fetal/mortalidade , Ultrassonografia Pré-Natal , Artérias Umbilicais/fisiopatologia , Velocidade do Fluxo Sanguíneo , Estudos de Coortes , Feminino , Morte Fetal , Retardo do Crescimento Fetal/fisiopatologia , Humanos , Recém-Nascido , Gravidez , Resultado da Gravidez , Fluxo Pulsátil , Ensaios Clínicos Controlados Aleatórios como Assunto , Artérias Umbilicais/diagnóstico por imagem
8.
J Perinat Med ; 47(4): 439-447, 2019 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-31005952

RESUMO

Background We developed an open-source software for the computerized analysis of antenatal fetal cardiotocography (CTG) without limitation of duration of the registration, enabling batch processing and adaptation to any digital storage system. Methods STVcalc was developed based on literature about the FetalCare system (Huntleigh Healthcare Ltd, Cardiff, UK). For comparison with FetalCare, we selected the CTGs of all women who delivered in 2011 a small-for-gestational-age (SGA) fetus between 24 and 31 weeks by cesarean section (CS) for fetal distress, or had fetal death, before labor onset. Results In 471 CTGs from 39 women, the agreement was 99% for a short-term variation (STV) cut-off of 2.6 ms below 29 weeks and 3.0 ms thereafter, and 95% for 3.5 and 4.0 ms, respectively. In 18 (4%) cases, the proportional difference in STV between FetalCare and STVcalc was more than 10%. Conclusion As only slight differences were observed between the proposed feature-rich application and the FetalCare system, it can be considered valuable for clinical practice and research purposes.


Assuntos
Cardiotocografia , Retardo do Crescimento Fetal , Software , Feminino , Humanos
9.
Arch Gynecol Obstet ; 299(2): 353-360, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30446842

RESUMO

PURPOSE: Fetal Doppler changes are well characterized in early-onset small-for-gestational-age (SGA) and fetal growth restriction (FGR) but less well characterized where the condition is late-onset. The aim of the study was to evaluate the role of computerized CTG (cCTG)-based short-term variation (STV) in late-onset SGA and FGR as an additional monitoring modality and to establish STV reference ranges in late third trimester healthy pregnancies. METHODS: Of 86 late-onset SGA fetuses diagnosed after 32 weeks, 66 were diagnosed with FGR. 138 healthy pregnancies acted as controls. All underwent umbilical artery pulsatility index (PI), middle cerebral artery PI, cerebroplacental ratio and mean uterine artery PI. cCTG recordings were analyzed by Sonicaid FetalCare software for STV calculation as described by Dawes/Redman. RESULTS: Median interval between inclusion and delivery was 13 (interquantile range = 4-30) days in the FGR group, 22 (12-37) days in the SGA group and 25 (10-40) days in the control group. STV was not different between controls (11.2 ms, 9.7-13.1), late-onset SGA (11.2 ms, 8.1-12.6) and FGR (10.5 ms, 8.5-12.4) fetuses. A greater proportion of late-onset SGA fetuses had STV < 5th percentile (7/86) compared to controls (4/138) (8.1% vs. 2.9%, p = 0.077). In the control group a significant positive correlation was seen between STV, and 1-min (ρ = 0.195, p = 0.026), 5-min (ρ = 0.247, p = 0.004) and 10-min (ρ = 0.211, p = 0.014) Apgar values. CONCLUSIONS: We report no significant difference in STV median values between controls, SGA and FGR pregnancies. However, more SGA fetuses had a low STV compared to controls. Prospective longitudinal studies are needed to investigate if low STV is a useful surveillance method for late-onset FGR.


Assuntos
Cardiotocografia/métodos , Retardo do Crescimento Fetal/diagnóstico por imagem , Recém-Nascido Pequeno para a Idade Gestacional/crescimento & desenvolvimento , Ultrassonografia Pré-Natal/métodos , Adulto , Feminino , Humanos , Recém-Nascido , Doenças do Recém-Nascido , Gravidez , Terceiro Trimestre da Gravidez , Estudos Prospectivos
10.
Arch Gynecol Obstet ; 299(2): 411-420, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30511191

RESUMO

OBJECTIVE: To evaluate the association of short-term variation (STV) and Doppler parameters with adverse perinatal outcome in low-risk fetuses at term. METHODS: This was a retrospective study of 1008 appropriate-for-gestational age (AGA) term fetuses. Doppler measurements [umbilical artery (UA), middle cerebral artery (MCA), and cerebroplacental ratio (CPR)] and computerized CTG (cCTG) with STV analysis were performed prior to active labor (≤ 4 cm cervical dilatation) within 72 h of delivery. The association between Doppler indices and STV values with adverse perinatal outcome was analyzed using univariate regression analysis. RESULTS: No significant association between Doppler parameters and the need for secondary cesarean delivery (CD) or operative vaginal delivery (OVD) was shown. Regarding fetuses delivered by CD due to fetal distress, regression analyzes revealed significantly higher UA PI MoM. However, the differences in MCA PI MoM and CPR MoM were not statistically significant. Fetuses with the need for emergency CD showed significantly higher UA PI MoM, lower MCA PI MoM and lower CPR MoM. Neonates with a 5-min Apgar score < 7 had significantly lower MCA PI MoM and neonatal acidosis (UA pH ≤ 7.10) showed a significant association with UA PI MoM. None of the assessed outcome parameters were significantly associated to STV. CONCLUSION: Doppler indices assessed close to delivery in low-risk fetuses at term show a moderate association with adverse outcome parameters, whereas STV does not appear to predict poor perinatal outcome in this group of fetuses.


Assuntos
Feto/irrigação sanguínea , Resultado da Gravidez/epidemiologia , Ultrassonografia Doppler/métodos , Ultrassonografia Pré-Natal/métodos , Adulto , Feminino , Humanos , Recém-Nascido , Masculino , Gravidez , Estudos Retrospectivos
11.
Arch Gynecol Obstet ; 300(3): 575-581, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31214775

RESUMO

OBJECTIVE: To evaluate the association of short-term variation (STV) and Doppler parameters with adverse perinatal outcome in small-for-gestational-age (SGA) fetuses at term. METHODS: In this retrospective single-center study 97 patients with singleton SGA fetuses at term (≥ 37 + 0 weeks' gestation) were examined. Inclusion criteria were a birth weight < 10th centile, cephalic presentation and planned vaginal birth. Only cases with available Doppler measurements of umbilical artery (UA) and middle cerebral artery (MCA) with calculated cerebroplacental ratio (CPR) in combination with a computerized CTG (cCTG) and STV 72 h prior to delivery were eligible for analysis. Pulsatility indices (PI) were converted into multiples of median (MoM), adjusted for gestational age. The association between Doppler indices and STV values with mode of delivery [secondary cesarean delivery (CD), operative vaginal delivery (OVD), as well as secondary CD and OVD due to fetal distress] and neonatal outcome [UA blood pH ≤ 7.15 and the need of admission to the neonatal intensive care unit (NICU)] was analyzed using logistic regression analysis. RESULTS: There was a significant association between UA PI MoM and the rate of CD. CD due to fetal distress, OVD and OVD due to fetal distress did not show a correlation with the evaluated Doppler parameters. Furthermore, we did not find an association between low UA birth pH and Doppler parameters while neonates with the need of admission to NICU had significant higher UA PI MoM and significant lower MCA PI MoM and CPR MoM. Regarding STV, a significant effect of low STV on NICU admission was found while none of the other assessed outcome parameters were significantly associated with STV. CONCLUSION: STV and Doppler parameters in SGA fetuses at term are significantly associated to the rate of NICU admission.


Assuntos
Sofrimento Fetal/diagnóstico por imagem , Recém-Nascido Pequeno para a Idade Gestacional , Ultrassonografia Doppler , Ultrassonografia Pré-Natal , Artérias Umbilicais/diagnóstico por imagem , Cardiotocografia , Parto Obstétrico , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Artéria Cerebral Média/diagnóstico por imagem , Valor Preditivo dos Testes , Gravidez , Resultado da Gravidez , Estudos Retrospectivos , Artérias Umbilicais/embriologia
12.
Ultrasound Obstet Gynecol ; 52(3): 347-351, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28782142

RESUMO

OBJECTIVES: Maternal gestational diabetes mellitus (GDM) is known to influence fetal physiology. Phase-rectified signal averaging (PRSA) is an innovative signal-processing technique that can be used to investigate fetal heart signals. The PRSA-calculated variables average acceleration capacity (AAC) and average deceleration capacity (ADC) are established indices of autonomic nervous system (ANS) function. The aim of this study was to evaluate the influence of GDM on the fetal cardiovascular and ANS function in human pregnancy using PRSA. METHODS: This was a prospective clinical case-control study of 58 mothers with diagnosed GDM and 58 gestational-age matched healthy controls in the third trimester of pregnancy. Fetal cardiotocography (CTG) recordings were performed in all cases at entry to the study, and a follow-up recording was performed in 19 GDM cases close to delivery. The AAC and ADC indices were calculated by the PRSA method and fetal heart rate short-term variation (STV) by CTG software according to Dawes-Redman criteria. RESULTS: Mean gestational age of both groups at study entry was 35.7 weeks. There was a significant difference in mean AAC (1.97 ± 0.33 bpm vs 2.42 ± 0.57 bpm; P < 0.001) and ADC (1.94 ± 0.32 bpm vs 2.28 ± 0.46 bpm; P < 0.001) between controls and fetuses of diabetic mothers. This difference could not be demonstrated using standard computerized fetal CTG analysis of STV (controls, 10.8 ± 3.0 ms vs GDM group, 11.3 ± 2.5 ms; P = 0.32). Longitudinal fetal heart rate measurements in a subgroup of women with diabetes were not significantly different from those at study entry. CONCLUSIONS: Our findings show increased ANS activity in fetuses of diabetic mothers in late gestation. Analysis of human fetal cardiovascular and ANS function by PRSA may offer improved surveillance over conventional techniques linking GDM pregnancy to future cardiovascular dysfunction in the offspring. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Sistema Nervoso Autônomo , Diabetes Gestacional/fisiopatologia , Frequência Cardíaca Fetal , Processamento de Sinais Assistido por Computador , Adulto , Peso ao Nascer , Cardiotocografia/métodos , Estudos de Casos e Controles , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Masculino , Gravidez , Terceiro Trimestre da Gravidez , Estudos Prospectivos , Ultrassonografia Pré-Natal
13.
Acta Obstet Gynecol Scand ; 97(10): 1274-1280, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29799630

RESUMO

INTRODUCTION: Fetal heart rate short term variation (STV) decreases with severe chronic hypoxia in the antenatal period. However, only limited research has been done on STV during labor. We have tested a novel algorithm for a valid baseline estimation and calculated STV. To explore the value of STV during labor, we compared STV with fetal scalp blood (FBS) lactate concentration, an early marker in the hypoxic process. MATERIAL AND METHODS: Software was developed which estimates baseline frequency using a novel algorithm and thereby calculates STV according to Dawes and Redman in up to four 30-minute blocks prior to each FBS. Cardiotocography traces from 1070 women in labor who had had FBS performed on 2134 occasions were analyzed. RESULTS: In acidemic cases (lactate >4.8 mmol/L; Lactate Pro™), median STV 30 minutes prior to FBS was 7.10 milliseconds compared with 6.09 milliseconds in the preacidemic (4.2-4.8 mmol/L) and 5.23 milliseconds in the normal (<4.2 mmol/L) groups (P < .05). There was a positive correlation between lactate and STV (rho = 0.16-0.24; P < .05). Median lactate concentration in cases with STV <3.0 milliseconds (n = 160) was 2.3 mmol/L. When 2 FBS were performed within 60 minutes the change rate of lactate correlated to STV (rho = 0.33; P < .001). Cases with increasing lactate concentration had a median STV of 5.29 milliseconds vs 4.41 milliseconds in those with decreasing lactate (P < .001). CONCLUSIONS: In the early stages of intrapartum hypoxia, STV increases, contrary to findings regarding chronic hypoxia in the antenatal period. The increase in the adrenergic surge is a likely explanation.


Assuntos
Cardiotocografia/instrumentação , Sangue Fetal/química , Hipóxia Fetal/diagnóstico , Frequência Cardíaca Fetal/fisiologia , Couro Cabeludo , Algoritmos , Hipóxia Fetal/prevenção & controle , Humanos , Software
14.
J Perinat Med ; 46(6): 599-604, 2018 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-28672744

RESUMO

AIMS: Currently one of the most widespread systems for the computerized analysis of the fetal heart rate (FHR) is the Dawes-Redman system, where the short-term variation (STV) of the FHR is measured by dividing each minute into 16 segments (STV16). Technical progress has allowed for the development of a new algorithm, which measures the STV by dividing each minute into 240 segments (STV240), thus approximating the beat-to-beat variation. The STV240 still lacks reference values. Our aim was to develop clinically relevant reference values for the STV240 and compare them to the ones for the STV16. METHODS: In a single centre, observational study, a total of 228 cardiotocograms were registered and subsequently analyzed with both algorithms (STV240 and STV16). RESULTS: The 95% confidence interval (CI) was calculated for both algorithms. The values of the STV240 were significantly lower in comparison to the ones of the STV16. Not only the mean values but also the 95th percentile of the STV240 lay beneath the existent cut-off value for the STV16. CONCLUSIONS: Every clinician using the new algorithm must be aware that the normal values for the STV240 lie beneath the, up until now, established cut-off values for the STV16.


Assuntos
Algoritmos , Cardiotocografia/estatística & dados numéricos , Frequência Cardíaca Fetal/fisiologia , Análise de Variância , Intervalos de Confiança , Feminino , Idade Gestacional , Determinação da Frequência Cardíaca/estatística & dados numéricos , Humanos , Gravidez , Estudos Prospectivos , Valores de Referência
15.
Ultrasound Obstet Gynecol ; 50(1): 71-78, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27484356

RESUMO

OBJECTIVES: To explore whether, in early fetal growth restriction (FGR), the longitudinal pattern of fetal heart rate (FHR) short-term variation (STV) can be used to identify imminent fetal distress and whether abnormalities of FHR recordings are associated with 2-year infant outcome. METHODS: The original TRUFFLE study assessed whether, in early FGR, delivery based on ductus venosus (DV) Doppler pulsatility index (PI), in combination with safety-net criteria of very low STV on cardiotocography (CTG) and/or recurrent FHR decelerations, could improve 2-year infant survival without neurological impairment in comparison with delivery based on CTG monitoring only. This was a secondary analysis of women who delivered before 32 weeks and had consecutive STV data recorded > 3 days before delivery and known infant outcome at 2 years of age. Women who received corticosteroids within 3 days of delivery were excluded. Individual regression line algorithms of all STV values, except the last one before delivery, were calculated. Life tables and Cox regression analysis were used to calculate the daily risk for low STV or very low STV and/or FHR decelerations (below DV group safety-net criteria) and to assess which parameters were associated with this risk. Furthermore, it was assessed whether STV pattern, last STV value or recurrent FHR decelerations were associated with 2-year infant outcome. RESULTS: One hundred and forty-nine women from the original TRUFFLE study met the inclusion criteria. Using the individual STV regression lines, prediction of a last STV below the cut-off used by the CTG monitoring group had sensitivity of 42% and specificity of 91%. For each day after study inclusion, the median risk for low STV (CTG group cut-off) was 4% (interquartile range (IQR), 2-7%) and for very low STV and/or recurrent FHR decelerations (below DV group safety-net criteria) was 5% (IQR, 4-7%). Measures of STV pattern, fetal Doppler (arterial or venous), birth-weight multiples of the median and gestational age did not usefully improve daily risk prediction. There was no association of STV regression coefficients, a low last STV and/or recurrent FHR decelerations with short- or long-term infant outcomes. CONCLUSION: The TRUFFLE study showed that a strategy of DV monitoring with safety-net criteria of very low STV and/or recurrent FHR decelerations for delivery indication could increase 2-year infant survival without neurological impairment. This post-hoc analysis demonstrates that, in early FGR, the daily risk of abnormal CTG, as defined by the DV group safety-net criteria, is 5%, and that prediction is not possible. This supports the rationale for CTG monitoring more often than daily in these high-risk fetuses. Low STV and/or recurrent FHR decelerations were not associated with adverse infant outcome and it appears safe to delay intervention until such abnormalities occur, as long as DV-PI is within normal range. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Retardo do Crescimento Fetal/diagnóstico por imagem , Coração Fetal/fisiologia , Frequência Cardíaca Fetal/fisiologia , Artéria Cerebral Média/diagnóstico por imagem , Adulto , Cardiotocografia , Pré-Escolar , Feminino , Retardo do Crescimento Fetal/mortalidade , Retardo do Crescimento Fetal/fisiopatologia , Humanos , Lactente , Recém-Nascido , Estudos Longitudinais , Artéria Cerebral Média/fisiologia , Gravidez , Resultado da Gravidez , Fluxo Pulsátil , Análise de Sobrevida , Ultrassonografia Pré-Natal
16.
Arch Gynecol Obstet ; 295(4): 811-816, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28180962

RESUMO

Timely recognition and appropriate management of high-risk pregnancies, such as intrauterine growth restriction (IUGR), are of paramount importance for every obstetrician. After the initial screening of IUGR fetuses through sonographic fetometry and Doppler, the focus is shifted to the appropriate monitoring and timing of delivery. This can, especially in cases of early IUGR, become a very difficult task. At this point, cardiotocography (CTG) is introduced as a major tool in the day-to-day monitoring of the antenatal well-being of the IUGR fetus. Since the first introduction of CTG up to the nowadays widely spreading implementation of computerised CTG in the clinical practice, there has been great progress in the recording of the fetal heart rate, as well as its interpretation. Focus of this review is to offer an understanding of the evolution of CTG from its early development to modern computerised methods and to provide an insight as to where the future of CTG is leading, especially in the monitoring of IUGR.


Assuntos
Cardiotocografia/métodos , Retardo do Crescimento Fetal/diagnóstico , Frequência Cardíaca Fetal , Gravidez de Alto Risco , Feminino , Retardo do Crescimento Fetal/diagnóstico por imagem , Feto/fisiopatologia , Humanos , Gravidez , Ultrassonografia
17.
Am J Obstet Gynecol ; 215(5): 630.e1-630.e7, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27343566

RESUMO

BACKGROUND: Phase-rectified signal averaging, an innovative signal processing technique, can be used to investigate quasi-periodic oscillations in noisy, nonstationary signals that are obtained from fetal heart rate. Phase-rectified signal averaging is currently the best method to predict survival after myocardial infarction in adult cardiology. Application of this method to fetal medicine has established significantly better identification than with short-term variation by computerized cardiotocography of growth-restricted fetuses. OBJECTIVE: The aim of this study was to determine the longitudinal progression of phase-rectified signal averaging indices in severely growth-restricted human fetuses and the prognostic accuracy of the technique in relation to perinatal and neurologic outcome. STUDY DESIGN: Raw data from cardiotocography monitoring of 279 human fetuses were obtained from 8 centers that took part in the multicenter European "TRUFFLE" trial on optimal timing of delivery in fetal growth restriction. Average acceleration and deceleration capacities were calculated by phase-rectified signal averaging to establish progression from 5 days to 1 day before delivery and were compared with short-term variation progression. The receiver operating characteristic curves of average acceleration and deceleration capacities and short-term variation were calculated and compared between techniques for short- and intermediate-term outcome. RESULTS: Average acceleration and deceleration capacities and short-term variation showed a progressive decrease in their diagnostic indices of fetal health from the first examination 5 days before delivery to 1 day before delivery. However, this decrease was significant 3 days before delivery for average acceleration and deceleration capacities, but 2 days before delivery for short-term variation. Compared with analysis of changes in short-term variation, analysis of (delta) average acceleration and deceleration capacities better predicted values of Apgar scores <7 and antenatal death (area under the curve for prediction of antenatal death: delta average acceleration capacity, 0.62 [confidence interval, 0.19-1.0]; delta short-term variation, 0.54 [confidence interval, 0.13-0.97]; P=.006; area under the curve for prediction Apgar <7: average deceleration capacity <24 hours before delivery, 0.64 [confidence interval, 0.52-0.76]; short-term variation <24 hours before delivery, 0.53 [confidence interval, 0.40-0.65]; P=.015). Neither phase-rectified signal averaging indices nor short-term variation showed predictive power for developmental disability at 2 years of age (Bayley developmental quotient, <95 or <85). CONCLUSION: The phase-rectified signal averaging method seems to be at least as good as short-term variation to monitor progressive deterioration of severely growth-restricted fetuses. Our findings suggest that for short-term outcomes such as Apgar score, phase-rectified signal averaging indices could be an even better test than short-term variation. Overall, our findings confirm the possible value of prospective trials based on phase-rectified signal averaging indices of autonomic nervous system of severely growth-restricted fetuses.


Assuntos
Cardiotocografia/métodos , Retardo do Crescimento Fetal/diagnóstico , Frequência Cardíaca Fetal/fisiologia , Processamento de Sinais Assistido por Computador , Adulto , Índice de Apgar , Deficiências do Desenvolvimento/diagnóstico , Deficiências do Desenvolvimento/etiologia , Feminino , Retardo do Crescimento Fetal/fisiopatologia , Humanos , Recém-Nascido , Estudos Longitudinais , Masculino , Valor Preditivo dos Testes , Gravidez , Prognóstico , Curva ROC
18.
BMC Pregnancy Childbirth ; 16: 55, 2016 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-26984160

RESUMO

BACKGROUND: Cardiotocography (CTG) has high sensitivity, but less specificity in detection of fetal hypoxia. There is need for adjunctive methods easy to apply during labor. Low fetal heart rate short term variation (STV) is predictive for hypoxia during the antenatal period. The objectives of our study were to methodologically evaluate monitoring of STV during labor and to compare two different monitors (Sonicaid™ and EDAN™) for antenatal use. METHODS: A prospective observational study at the obstetric department, Karolinska University hospital, Stockholm (between September 2011 and April 2015). In 100 women of ≥ 36 weeks gestation, STV values were calculated during active labor. In a subset of 20 women we compared STV values between internal and external signal acquisition. Additionally we compared antenatal monitoring with two different monitors in another 20 women. RESULTS: Median STV in 100 fetuses monitored with scalp electrode during labor (EDAN™) was 7.1 msec (range 1.3-25.9) with no difference between early (3-6 cm) and late (7-10 cm) labor (7.1 vs 6.8 msec; p = 0.80). STV calculated from scalp electrode signals were positively correlated with delta-STV (STV internal -external) (R = 0.70; p < 0.01). No significant differences were found between Sonicaid™ and EDAN™ in antenatal external monitoring of STV (median difference 0.9 msec, Spearman Rank Correlation Sonicaid vs delta-STV; R = 0.35; p = 0.14). CONCLUSIONS: Median intrapartum STV was 7.1 msec. Significant differences were found between internal and external signal acquisition, a finding that suggests further intrapartum studies to be analysed separately depending upon type of signal acquisition. Antenatal external monitoring with Sonicaid™ and EDAN™ indicates that the devices perform equally well in the identification of acidemic fetuses. Further studies are needed to assess the clinical value of intrapartum STV.


Assuntos
Cardiotocografia/instrumentação , Hipóxia Fetal/diagnóstico , Frequência Cardíaca Fetal/fisiologia , Complicações do Trabalho de Parto/diagnóstico , Adulto , Cardiotocografia/métodos , Feminino , Hipóxia Fetal/prevenção & controle , Idade Gestacional , Humanos , Trabalho de Parto/fisiologia , Complicações do Trabalho de Parto/prevenção & controle , Gravidez , Estudos Prospectivos , Sensibilidade e Especificidade , Estatísticas não Paramétricas
19.
BJOG ; 121(7): 889-94, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24842087

RESUMO

OBJECTIVE: Recent studies suggest that phase-rectified signal averaging (PRSA), measured in antepartum fetal heart rate (FHR) traces, may sensitively indicate fetal status; however, its value has not been assessed during labour. We determined whether PRSA relates to acidaemia in labour, and compare its performance to short-term variation (STV), a related computerised FHR feature. DESIGN: Historical cohort. SETTING: Large UK teaching hospital. POPULATION: All 7568 Oxford deliveries that met the study criteria from April 1993 to February 2008. METHODS: We analysed the last 30 minutes of the FHR and associated outcomes of infants. We used computerised analysis to calculate PRSA decelerative capacity (DC(PRSA)), and its ability to predict umbilical arterial blood pH ≤ 7.05 using receiver operator characteristic (ROC) curves and event rate estimates (EveREst). We compared DC(PRSA) with STV calculated on the same traces. MAIN OUTCOME MEASURE: Umbilical arterial blood pH ≤ 7.05. RESULTS: We found that PRSA could be measured in all cases. DC(PRSA) predicted acidaemia significantly better than STV: the area under the ROC curve was 0.665 (95% CI 0.632-0.699) for DC(PRSA), and 0.606 (0.573-0.639) for STV (P = 0.007). EveREst plots showed that in the worst fifth centile of cases, the incidence of low pH was 17.75% for DC(PRSA) but 11.00% for STV (P < 0.001). DC(PRSA) was not highly correlated with STV. CONCLUSIONS: DC(PRSA) of the FHR can be measured in labour, and appears to predict acidaemia more accurately than STV. Further prospective evaluation is warranted to assess whether this could be clinically useful. The weak correlation between DC(PRSA) and STV suggests that they could be combined in multivariate FHR analyses.


Assuntos
Acidose/sangue , Acidose/fisiopatologia , Cardiotocografia , Frequência Cardíaca Fetal/fisiologia , Estudos de Coortes , Feminino , Doenças Fetais/fisiopatologia , Humanos , Gravidez , Estudos Retrospectivos
20.
J Matern Fetal Neonatal Med ; 37(1): 2345855, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38679588

RESUMO

INTRODUCTION: Intraamniotic infection (IAI) and subsequent early-onset neonatal sepsis (EONS) are among the main complications associated with preterm prelabor rupture of membranes (PPROM). Currently used diagnostic tools have been shown to have poor diagnostic performance for IAI. This study aimed to investigate whether the exposure to IAI before delivery is associated with short-term variation of the fetal heart rate in pregnancies with PPROM. METHODS: Observational cohort study of 678 pregnancies with PPROM, delivering between 24 + 0 and 33 + 6 gestational weeks from 2012 to 2019 in five labor units in Stockholm County, Sweden. Electronic medical records were examined to obtain background and exposure data. For the exposure IAI, we used the later diagnosis of EONS in the offspring as a proxy. EONS is strongly associated to IAI and was considered a better proxy for IAI than the histological diagnosis of acute chorioamnionitis, since acute chorioamnionitis can be observed in the absence of both positive microbiology and biochemical markers for inflammation. Cardiotocography traces were analyzed by a computerized algorithm for short-term variation of the fetal heart rate, which was the main outcome measure. RESULTS: Twenty-seven pregnancies were categorized as having an IAI, based on the proxy diagnosis of EONS after birth. Fetuses exposed to IAI had significantly lower short-term variation values in the last cardiotocography trace before birth than fetuses who were not exposed (5.25 vs 6.62 ms; unadjusted difference: -1.37, p = 0.009). After adjustment for smoking and diabetes, this difference remained significant. IAI with a later positive blood culture in the neonate (n = 12) showed an even larger absolute difference in STV (-1.65; p = 0.034), with a relative decrease of 23.5%. CONCLUSION: In pregnancies with PPROM, fetuses exposed to IAI with EONS as a proxy have lower short-term variation of the fetal heart rate than fetuses who are not exposed. Short-term variation might be useful as adjunct surveillance in pregnancies with PPROM.


Assuntos
Cardiotocografia , Ruptura Prematura de Membranas Fetais , Frequência Cardíaca Fetal , Humanos , Feminino , Gravidez , Frequência Cardíaca Fetal/fisiologia , Ruptura Prematura de Membranas Fetais/diagnóstico , Adulto , Recém-Nascido , Corioamnionite/diagnóstico , Estudos de Coortes , Suécia/epidemiologia , Sepse Neonatal/diagnóstico , Complicações Infecciosas na Gravidez/diagnóstico , Idade Gestacional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA