1.
Sensors (Basel) ; 24(5)2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38474924

RESUMO

In this study, a controllable equal-gap large-area silicon drift detector (L-SDD) is designed. The surface leakage current is reduced by reducing the SiO2-Si interface through the new controllable equal-gap design. The design of the equal gap also solves the problem whereby the gap widens due to the larger detector size in the previous SDD design, which leads to a large invalid area of the detector. In this paper, a spiral hexagonal equal-gap L-SDD of 1 cm radius is selected for design calculation, and we implement 3D modeling and simulation of the device. The simulation results show that the internal potential gradient distribution of the L-SDD is uniform and forms a drift electric field, with the direction of electron drift pointing towards the collecting anode. The L-SDD has an excellent electron drift channel inside, and this article also analyzes the electrical performance of the drift channel to verify the correctness of the design method of the L-SDD.

2.
Sensors (Basel) ; 22(13)2022 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-35808271

RESUMO

In this study, we present a procedure to optimize a set of finite impulse response filter (FIR) coefficients for digital pulse-amplitude measurement. Such an optimized filter is designed using an adapted digital penalized least mean square (DPLMS) method. The effectiveness of the procedure is demonstrated using a dataset from a case study on high-resolution X-ray spectroscopy based on single-photon detection and energy measurements. The energy resolutions of the Kα and Kß lines of the Manganese energy spectrum have been improved by approximately 20%, compared to the reference values obtained by fitting individual photon pulses with the corresponding mathematical model.


Assuntos
Análise de Dados , Processamento de Sinais Assistido por Computador , Modelos Teóricos , Análise Espectral , Raios X
3.
J Synchrotron Radiat ; 27(Pt 2): 329-339, 2020 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-32153271

RESUMO

Detection of heavy elements, such as metals, in macromolecular crystallography (MX) samples by X-ray fluorescence is a function traditionally covered at synchrotron MX beamlines by silicon drift detectors, which cannot be used at X-ray free-electron lasers because of the very short duration of the X-ray pulses. Here it is shown that the hybrid pixel charge-integrating detector JUNGFRAU can fulfill this function when operating in a low-flux regime. The feasibility of precise position determination of micrometre-sized metal marks is also demonstrated, to be used as fiducials for offline prelocation in serial crystallography experiments, based on the specific fluorescence signal measured with JUNGFRAU, both at the synchrotron and at SwissFEL. Finally, the measurement of elemental absorption edges at a synchrotron beamline using JUNGFRAU is also demonstrated.

4.
Micromachines (Basel) ; 15(4)2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38675329

RESUMO

A novel position-sensitive linear winding silicon drift detector (LWSDD) was designed and simulated. On the frontside (anode side), the collecting anodes were set on both sides of the detector, and an S-shaped linear winding cathode strip was arranged in the middle, which can realize independent voltage division and reduce the complexity of external bias resistor chain compared with the traditional linear silicon drift detector. The detectors were arranged in a butterfly shape, which increased the effective area of the detectors and improved the collection efficiency. The linear winding silicon drift detector can obtain one-dimensional position information by measuring the drift time of electrons. The 2D position information of the incident particle is obtained from the anodes coordinates of the readout signal. One-dimensional analytically exact solutions of electric potential and field were obtained for the first time for the linear winding silicon drift detector. The simulation results show that the electric potential distribution inside the detector is uniform, and the "drift channel" inside the detector points to the collecting anodes on both sides, which proves the reasonable and feasible design of the linear winding silicon drift detector.

5.
Nucl Phys A ; 914(100): 305-309, 2013 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-24068854

RESUMO

The kaonic 3He and 4He [Formula: see text] transitions in gaseous targets were observed by the SIDDHARTA experiment. The X-ray energies of these transitions were measured with large-area silicon-drift detectors using the timing information of the [Formula: see text] pairs produced by the DAΦNE [Formula: see text] collider. The strong-interaction shifts and widths both of the kaonic 3He and 4He 2p states were determined, which are much smaller than the results obtained by the previous experiments. The "kaonic helium puzzle" (a discrepancy between theory and experiment) was now resolved.