Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39359183

RESUMO

BACKGROUND: Sirolimus-coated balloon (SCB), a relatively novel technology appears attractive due to the drug properties (safety and efficacy) and sirolimus remains the drug of choice in stents. However, there is limited data long-term data on SCB. In this study, we have explored the clinical outcomes following the use of SCB in de-novo lesions from a real-world practice. AIMS: To report long-term clinical outcomes following the use of Siroliumus coated balloon in de novo lesions. METHODS AND RESULTS: We analyzed all patients treated with an SCB in de novo lesions between 2016 and 2023 at four high-volume centers in UK and Italy. The outcomes measured included cardiac death, target vessel myocardial infarction (TVMI), target lesion revascularization (TLR) and major adverse cardiac events (MACE). During the study period, 771 patients had SCB in de novo lesions. Diabetes mellitus was noted in 36% of patients (n = 280), of which 14% (n = 108) were insulin dependent. Fifteen percent (n = 117) had chronic kidney disease, Fifty-two percent (n = 398) of cases were in the setting acute coronary syndrome (ACS) and of which 51 cases (7%) were ST-segment elevation myocardial infarction. Small vessels (<3.0 mm) accounted for 78% (n = 601) of cases and 76% (n = 584) were long lesions ( ≥ $\ge $ 20 mm). The mean diameter of SCB was 2.6 ± 0.4 mm and the mean length was 25 ± 10.39 mm. Bailout stenting following SCB was required in 9% lesions (n = 67). During the median follow-up 640 days, total death occurred in 39 (5%) patients and of which, cardiac death occurred in 10 patients (1.3%). TVMI occurred in 20 patients (2.6%). TLR and TVR were 5.6% and 5.8% respectively. The overall MACE rate was 8%. We had no documented case of acute vessel closure. CONCLUSIONS: The results from this long-term follow-up in a real-world population are encouraging with low rates of hard endpoints and acceptable rates of TLR and MACE despite a complex group of patients. Our data suggest that SCBs are safe in coronary intervention with good clinical outcomes in the long term.

2.
Artigo em Inglês | MEDLINE | ID: mdl-39044661

RESUMO

BACKGROUND: Although use of sirolimus-based analogs has shown superiority over paclitaxel in drug-eluting stents, the relative efficacy of these two agents released from drug-coated balloons (DCB) is unclear. The present meta-analysis is aimed to compare outcomes after percutaneous coronary intervention (PCI) with paclitaxel-coated balloons (PCB) versus sirolimus-coated balloons (SCB) for either in-stent restenosis or native de novo lesions. METHODS: The study outcomes were 1) target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction, or target lesion revascularization, and 2) follow-up angiographic parameters including late lumen loss (LLL), diameter stenosis, and minimal lumen diameter (MLD). Pooled odds ratios (OR) and weighted mean differences (WMD) with 95% confidence intervals (CI) were calculated by using random-effects models. RESULTS: A search of PubMed, EMBASE, and Cochrane Library from their inception to January 2024 identified five randomized clinical trials and three observational studies with a total of 1861 patients (889 in PCB and 972 in SCB groups). During 9-12 months of follow-up, there was no significant difference in TLF (OR 1.01, 95% CI 0.75-1.35) between the two groups. On follow-up angiography at 6-9 months, MLD (WMD 0.10, 95% CI 0.02-0.17) was larger in PCB but there was no statistically significant difference in LLL (WMD -0.11, 95% CI -0.23-0.02) and diameter stenosis (WMD -3.33, 95% CI -8.11-1.45). CONCLUSIONS: Among patients undergoing DCB-only PCI, the risk of TLF was similar during 9-12 months of follow-up after PCB and SCB treatment. However, the MLD was larger favoring PCB over SCB on follow-up angiography.

3.
J Endovasc Ther ; : 15266028231217657, 2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38084379

RESUMO

PURPOSE: The aim of this study was to assess the efficacy and safety of the novel SLR (SELUTION sustained-limus-release) drug-coated balloon (DCB) in the treatment of the femoropopliteal steno-occlusive disease. MATERIALS AND METHODS: From February 2021 to March 2022, 80 consecutive patients (age: 69.5±8.23 years; total number of lesions: 80) with a steno-occlusive lesion of superficial femoral artery were enrolled at our center. A total of 60 patients (75%) had claudication, whereas 20 (25%) had chronic limb-threatening ischemia (CLTI). The mean lesion length was 171±82.22 mm. The primary efficacy outcome was primary patency at 12 months, defined as freedom from restenosis determined by a duplex ultrasound peak systolic velocity ratio ≤2.4. The secondary efficacy outcome was freedom from clinically-driven target lesion revascularization (CD-TLR) at 12 months. The primary safety outcome was a composite of freedom from device- and procedure-related mortality, major target limb amputation, and clinically-driven target lesion urgent revascularization (endovascular or bypass graft) at 30 days and 12 months. RESULTS: Device success was achieved in all 80 patients. One death on day 7 from cardiovascular complications was ruled procedure-related because it occurred within the first 30 days from the discharge. Two patients with CLTI experienced planned minor amputations of target limb, and one patient underwent urgent bypass graft of the target vessel for early occlusion at 60 days from the index procedure. The primary safety outcome was 98.7% and 97.5% at 30 days and 12 months, respectively. At 1 year, primary patency was 86.3%, and freedom from CD-TLR was 96.2%. CONCLUSION: These findings suggest that using a novel sirolimus-coated balloon is a safe and effective treatment option for femoropopliteal steno-occlusive lesions in a variety of clinical and anatomical settings. These results will need to be confirmed by long-term follow-up and randomized controlled trials. CLINICAL IMPACT: In femoropopliteal steno-occlusive lesions paclitaxel drug-coated devices have been proved to be able to achieve a better vessel patency during follow-up compared with uncoated balloon, but according to a recent meta-analysis they may carry an elevated risk of late mortality. Sirolimus results in a wider therapeutic range with a 3-fold higher margin of safety. Sirolimus coated devices have recently been proposed as an alternative. This study suggests that using a novel sirolimus-coated balloon is a safe and effective treatment option for femoropopliteal steno-occlusive lesions.

4.
Catheter Cardiovasc Interv ; 98(1): 57-65, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32473075

RESUMO

BACKGROUND: Use of drug coated balloons (DCBs) in coronary intervention is escalating. There is a plethora of data on Paclitaxcel-DCB. However, when it comes of stents, Limus-drugs are preferred over Paclitaxel. There is very limited data on Sirolimus coated balloons (SCB). MagicTouch-SCB (Concept Medical, FL) elutes Sirolimus via nano-technology and have been used in our centers since March 2018. We report a mid-term follow-up with this relatively novel-technology. METHODS AND RESULTS: We retrospectively analyzed all patients treated with MagicTouch-SCB between March-2018 and February-2019. Results are reported as cardiac-death, target-vessel myocardial-infarction (TVMI), target lesion revascularization (TLR) and Major Adverse Cardiac Events (MACE). During the study period, 288-patients (373-lesions) with a mean age of 65.8 were treated with MagicTouch-SCB. 84% (n = 241) were male, 155 (54%) were in the setting of acute coronary syndrome, 38% (n = 110) had diabetes and 62% (n = 233) were in de-novo lesions. Most lesions treated were in the LAD/diagonal-system (n = 170; 46%). Pre-dilatation was performed in 92% (n = 345) of cases. Bailout stenting was required in 9% lesions (n = 35). The mean diameter and length of SCBs were 2.64 ± 0.56 mm and 24 ± 8.9 mm respectively. During a median follow-up of 363 days (IQR: 278-435), cardiac death and TVMI occurred in 5-patients (1.7%) and 10-patients (3.4%) respectively, TLR per-lesion was 12%. The MACE rate was 10%. There were no documented cases of acute vessel closure. CONCLUSIONS: The results from mid-term follow-up with this relatively new technology SCB is encouraging with a low rates of hard endpoints and acceptable MACE rates despite complex group of patients and lesion subsets.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel , Estudos Retrospectivos , Sirolimo/efeitos adversos , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 96(5): E496-E500, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32191384

RESUMO

OBJECTIVES: To test the long-term efficacy of a sirolimus-coated balloon (SCB). BACKGROUND: Nanoluté was a prospective registry to evaluate the clinical performance of a novel SCB (Concept Medical Research Private Limited, India) for the treatment of de novo coronary lesions and in-stent restenosis (ISR). We here present the 24 months clinical data. METHODS: All patients treated with SCB for any type of coronary indication between July 2012 and September 2015 were enrolled at Indian centers and clinically followed up to 24 months. Primary endpoints were major adverse cardiovascular events (MACE) defined as a composite of cardiac death, target lesion revascularization (TLR), and target vessel-myocardial infarction (MI). RESULTS: A total of 484 SCBs were used in 408 patients to treat 435 lesions. In detail, the SCB was used for 183 patients with ISR, 185 with de novo small vessel disease, and 40 with de novo large vessel disease. Mean balloon length and diameter (average ± SD) were 22.3 ± 7.1 mm and 2.7 ± 0.40 mm, respectively. All patients with 24 months follow-up were included. Overall MACE rate was 4.2% (n = 17) with three cardiac deaths (0.7%), 13 TLR (3.2%), and one MI (0.2%). CONCLUSION: The Nanoluté prospective registry is the first long-term clinical evidence of the safety and feasibility of this type of SCB, both in patients with ISR or de novo lesions.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Reestenose Coronária/terapia , Sirolimo/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/mortalidade , Desenho de Equipamento , Feminino , Humanos , Índia , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
Circ Cardiovasc Interv ; 17(9): e014064, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39051094

RESUMO

BACKGROUND: Evidence suggests that drug-coated balloons may benefit in-stent restenosis (ISR) treatment. However, the efficacy of new-generation sirolimus-coated balloon (SCB) compared with the latest generation drug-eluting stents (DESs) has not been studied in this setting. METHODS: All patients in the EASTBORNE (The All-Comers Sirolimus-Coated Balloon European Registry) and DEB-DRAGON (DEB vs Thin-DES in DES-ISR: Long Term Outcomes) registries undergoing percutaneous coronary intervention for DES-ISR were included in the study. The primary study end point was target lesion revascularization at 24 months. Secondary end points were major adverse cardiovascular events, all-cause death, myocardial infarction, and target vessel revascularization at 24 months. Our goal was to evaluate the efficacy and safety of SCB versus thin-struts DES in ISR at long-term follow-up. RESULTS: A total of 1545 patients with 1679 ISR lesions were included in the pooled analysis, of whom 621 (40.2%) patients with 621 lesions were treated with thin-strut DES and 924 (59.8%) patients with 1045 lesions were treated with SCB. The unmatched cohort showed no differences in the incidence of target lesion revascularization (10.8% versus 11.8%; P=0.568); however, there was a trend toward lower rates of myocardial infarction (7.4% versus 5.0%; P=0.062) and major adverse cardiovascular events (20.8% versus 17.1%; P=0.072) in the SCB group. After propensity score matching (n=335 patients per group), there were no significant differences in the rates of target lesion revascularization (11.6% versus 11.8%; P=0.329), target vessel revascularization (14.0% versus 13.1%; P=0.822), myocardial infarction (7.2% versus 4.5%; P=0.186), all-cause death (5.7% versus 4.2%; P=0.476), and major adverse cardiovascular event (21.5% versus 17.6%; P=0.242) between DES and SCB treatment. CONCLUSIONS: In patients with ISR, angioplasty with SCB compared with thin-struts DES is associated with comparable rates of target lesion revascularization, target vessel revascularization, myocardial infarction, all-cause death, and major adverse cardiovascular events at 2 years.


Assuntos
Fármacos Cardiovasculares , Materiais Revestidos Biocompatíveis , Reestenose Coronária , Stents Farmacológicos , Sistema de Registros , Sirolimo , Humanos , Masculino , Feminino , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Reestenose Coronária/etiologia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/mortalidade , Reestenose Coronária/terapia , Fatores de Tempo , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Fatores de Risco , Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Europa (Continente) , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/etiologia , Cateteres Cardíacos , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/diagnóstico por imagem
7.
JACC Cardiovasc Interv ; 17(13): 1547-1556, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38842992

RESUMO

BACKGROUND: Sirolimus-coated balloons (SCB) for the treatment of femoropopliteal (FP) lesions have not been systematically studied, but initial outcomes from early studies are promising. OBJECTIVES: The authors sought to evaluate the safety and efficacy of the SELUTION SLR SCB, composed of proprietary microreservoir technology combining sirolimus and biodegradable polymer, when used to treat mild-to-moderate FP disease in a Japanese population. METHODS: This multicenter, prospective, single-arm study (SELUTION SFA JAPAN) enrolled 134 patients with FP disease. It was independently adjudicated by an imaging core laboratory and clinical events committee. The primary endpoint was 12-month primary patency, defined as peak systolic velocity ratio ≥2.5 by duplex ultrasound and compared against a prespecified performance goal of 60% based on established angioplasty data. RESULTS: The mean age was 73.8 ± 6.9 years, and 60.3% of patients had diabetes mellitus. The mean lesion length was 127.4 ± 59.7 mm, 17.2% were chronic total occlusions, and 47.8% involved the popliteal artery. Data on 12-month restenosis were available in 127 patients (94.8%). The 12-month primary patency rate was 87.9%, and the freedom from clinically driven target lesion revascularization (CD-TLR) was 97.0% per Kaplan-Meier estimate. The major adverse event rate was 6.7%, driven by 4 CD-TLRs and 5 deaths, none of which were related to the device or procedure. Ankle-brachial index data improved significantly from 0.73 ± 0.16 at baseline to 0.96 ± 0.14 at 30 days postprocedure and was sustained through 12 months (0.94 ± 0.13). CONCLUSIONS: The SELUTION SFA JAPAN trial demonstrated that a novel SELUTION SCB is a safe and effective treatment option for FP disease in symptomatic patients.


Assuntos
Angioplastia com Balão , Fármacos Cardiovasculares , Materiais Revestidos Biocompatíveis , Artéria Femoral , Doença Arterial Periférica , Artéria Poplítea , Sirolimo , Dispositivos de Acesso Vascular , Grau de Desobstrução Vascular , Humanos , Artéria Poplítea/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Idoso , Masculino , Feminino , Artéria Femoral/fisiopatologia , Artéria Femoral/diagnóstico por imagem , Doença Arterial Periférica/terapia , Doença Arterial Periférica/fisiopatologia , Doença Arterial Periférica/diagnóstico por imagem , Estudos Prospectivos , Japão , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Angioplastia com Balão/instrumentação , Angioplastia com Balão/efeitos adversos , Fatores de Tempo , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Idoso de 80 Anos ou mais , Recidiva , Resultado do Tratamento , Desenho de Equipamento , Fatores de Risco , Pessoa de Meia-Idade
8.
Future Cardiol ; : 1-15, 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39105679

RESUMO

The Magic Touch sirolimus-coated balloon (SCB) was recently introduced in Europe and features robust clinical technology different from other devices on the market. This device is able to deliver a sufficient sirolimus dose to the target segment to reduce neointimal proliferation with very little exposure downstream and no apparent adverse effects at sustained high drug concentrations. The SCB represents a promising novelty within the drug-coated balloon arena due to its mid-term efficacy and safety in the treatment of coronary artery disease, especially in de novo and small-vessel coronary lesions. The purpose of this article is to provide an up-to-date overview of the currently available animal and clinical trial results, as well as to highlight ongoing trials on the Magic Touch SCB.


Among modern drug-coated balloons, Magic Touch features Nanolutè technology, which allows effective and rapid sirolimus release and retention for 8­12 weeks. Previous and ongoing trials are showing good clinical performance with sustained safety.

9.
JACC Cardiovasc Interv ; 16(14): 1794-1803, 2023 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-37495352

RESUMO

BACKGROUND: Drug-coated balloons (DCB) represent 1 of the most promising innovations in interventional cardiology and may represent a valid alternative to drug-eluting stents. Currently, some sirolimus-coated balloons (SCB) are being investigated for several coronary artery disease applications. OBJECTIVES: This study sought to understand the role of a novel SCB for the treatment of coronary artery disease. METHODS: EASTBOURNE (All-Comers Sirolimus-Coated Balloon European Registry) is a prospective, multicenter, investigator-driven clinical study that enrolled real-world patients treated with SCB. Primary endpoint was target lesion revascularization (TLR) at 12 months. Secondary endpoints were procedural success, myocardial infarction (MI), all-cause death, and major adverse clinical events (a composite of death, MI, and TLR). All adverse events were censored and adjudicated by an independent clinical events committee. RESULTS: A total population of 2,123 patients (2,440 lesions) was enrolled at 38 study centers in Europe and Asia. The average age was 66.6 ± 11.3 years, and diabetic patients were 41.5%. De novo lesions (small vessels) were 56%, in-stent restenosis (ISR) 44%, and bailout stenting occurred in 7.7% of the patients. After 12 months, TLR occurred in 5.9% of the lesions, major adverse clinical events in 9.9%, and spontaneous MI in 2.4% of the patients. The rates of cardiac/all-cause death were 1.5% and 2.5%, respectively. The primary outcome occurred more frequently in the ISR cohort (10.5% vs 2.0%; risk ratio: 1.90; 95% CI: 1.13-3.19). After multivariate Cox regression model, the main determinant for occurrence of the primary endpoint was ISR (OR: 5.5; 95% CI: 3.382-8.881). CONCLUSIONS: EASTBOURNE, the largest DCB study in the coronary field, shows the safety and efficacy of a novel SCB in a broad population of coronary artery disease including small vessels and ISR patients at mid-term follow-up. (The All-Comers Sirolimus-Coated Balloon European Registry [EASTBOURNE]; NCT03085823).


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Reestenose Coronária , Infarto do Miocárdio , Humanos , Pessoa de Meia-Idade , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Angioplastia Coronária com Balão/efeitos adversos , Sirolimo/efeitos adversos , Resultado do Tratamento , Infarto do Miocárdio/complicações , Sistema de Registros , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia
10.
J Vasc Access ; 24(5): 1008-1017, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34965764

RESUMO

BACKGROUND: Aim of this pilot clinical study was to evaluate the safety and efficacy of the Selution Sustained Limus Release (SLR)™ sirolimus-eluting balloon (SEB) for improving failing arterio-venous fistulas (AVF) patency in Asian haemodialysis patients. METHODS: Prospective single-centre, multi-investigator, non-consecutive, non-blinded single arm trial. Forty end-stage renal failure Asian patients with a dysfunctional AVF underwent SEB angioplasty between May and November 2020. All stenotic lesions were prepared with high pressure non-compliant balloon angioplasty prior to SEB angioplasty. Endpoints of interest included target lesion primary patency and circuit access patency and safety through 30 days. All patients received dual antiplatelet therapy for 1 month and were followed up with Duplex ultrasound at 6 months. RESULTS: There was one subject dropout so final n = 39 patients (mean age 65.0 ± 11.9; males = 26 (66.7%)) and n = 43 target lesions treated. Main indication for intervention was dropping access flow (24/39; 61.5%) and most common target lesion was in the juxta-anastomosis (24/43; 54.5%). There was 100% technical and procedural success. There were no adverse events related to the SEB. Target lesion primary patency rates at 3 and 6 months were 39/41 (95.1%) and 28/39 (71.8%) respectively. Access circuit patency rates at 3 and 6 months were 35/37 (94.6%) and 22/35 (62.9%) respectively. There were 3 (7.7%) deaths all attributable to patients' underlying co-morbidities. CONCLUSIONS: Fistuloplasty using the novel Selution SLR™ SEB for dysfunctional AVF circuits seems a safe and effective modality in Asian haemodialysis patients at 6 months but larger randomised controlled studies are required now to determine its true efficacy against plain balloon angioplasty.


Assuntos
Angioplastia com Balão , Fístula Arteriovenosa , Derivação Arteriovenosa Cirúrgica , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Angioplastia com Balão/efeitos adversos , Fístula Arteriovenosa/etiologia , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Materiais Revestidos Biocompatíveis , Estudos Prospectivos , Diálise Renal/efeitos adversos , Sirolimo , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
11.
J Vasc Access ; 24(2): 289-299, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34219511

RESUMO

BACKGROUND: The aim of this pilot clinical study is to evaluate the safety and efficacy of the Selution Sustained Limus Release (SLR)™ sirolimus-coated balloon (M.A. MedAlliance SA, Nyon, Switzerland) for improving the patency of failing arterio-venous fistulas (AVF) in hemodialysis patients. We also present herein a pre-clinical pharmacokinetic and safety evaluation of Selution™ to justify its first use in hemodialysis patients for endovascular access salvage. METHODS AND RESULTS: This is an investigator-initiated prospective single-center, non-blinded single-arm trial. Forty patients with clinically significant de novo or recurrent stenoses in a mature AVF circuit will be recruited. All stenotic lesions will be prepared with high pressure non-compliant conventional balloon angioplasty (CBA) prior to deployment of the Sustained-Release Selution™ sirolimus drug-eluting balloon. The primary efficacy endpoint is 6-month target lesion primary patency and the primary safety endpoint is freedom from localized or systemic serious adverse events through 30 days. Secondary endpoints of interest include technical and clinical success rates and circuit access patency at 3 and 6 months. Follow-up will occur for 2 years for those patients whose AVFs remain patent. Pharmacokinetic and histological animal safety studies performed with the Selution™ coating formulation showed prolonged arterial tissue retention of sirolimus with therapeutic levels up to 60 days and non-toxic and rapidly declining blood levels. Histological results in animal models demonstrated safety, freedom from intraluminal thrombus, reduction in restenosis by sirolimus elution compared to CBA, and no evidence of embolic phenomena indicative of adverse particulate effects. DISCUSSION: Long release sirolimus coated balloons may serve as a promising novel alternative therapy to paclitaxel-based technology for treating conduit stenosis secondary to neointimal hyperplasia. Pre-clinical pharmacokinetic and histological animal data are encouraging and provide suggestion of safety and efficacy in this setting. This single-center trial will provide a first step toward demonstration of efficacy and safety of this device for treatment of stenotic fistulas.


Assuntos
Angioplastia com Balão , Fístula Arteriovenosa , Humanos , Fístula Arteriovenosa/etiologia , Materiais Revestidos Biocompatíveis , Constrição Patológica/etiologia , Paclitaxel , Estudos Prospectivos , Diálise Renal/efeitos adversos , Sirolimo/efeitos adversos , Resultado do Tratamento , Grau de Desobstrução Vascular , Projetos Piloto
12.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38056772

RESUMO

INTRODUCTION AND OBJECTIVES: The PEACE study (Performance of a sirolimus-eluting balloon strategy in acute and chronic coronary syndromes) investigated for the first time whether a sirolimus-coated balloon (SCB) (Magic Touch, Concept Medical, India) is associated with different outcomes depending on whether it is used in acute coronary syndromes (ACS) or chronic coronary syndromes (CCS). METHODS: This was a post-hoc analysis from the all-comers EASTBOURNE Registry (NCT03085823). Out of 2083 patients enrolled, an SCB was used to treat 968 (46.5%) ACS and 1115 (53.5%) CCS patients. The primary endpoint was target lesion revascularization at 12 months, while secondary endpoints were angiographic success and major adverse cardiovascular events. RESULTS: Baseline demographics, mean reference vessel diameter and mean lesion length were comparable between ACS and CCS. Predilatation was more commonly performed in ACS (P=.007). SCB was inflated at a standard pressure in both groups with a slight trend toward longer inflation time in ACS. Angiographic success was high in both groups (ACS 97.4% vs CCS 97.7%, P=.820) with limited bailout stenting. Similarly, at 12 months the cumulative incidence of target lesion revascularization (ACS 6.6% vs CCS 5.2%, P=.258) was comparable between ACS and CCS. Conversely, a higher rate of major adverse cardiovascular events in acute presenters was mainly driven by myocardial infarction recurrencies (ACS 10.4% vs CCS 8.3%, P=.009). In-stent restenosis showed a higher proportion of target lesion revascularization and major adverse cardiovascular events than de novo lesions, independently of the type of presentation at the index procedure. CONCLUSIONS: This SCB shows good performance in terms of acute and 1-year outcomes independently of the clinical presentation.

13.
JACC Cardiovasc Interv ; 15(7): 770-779, 2022 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-35305906

RESUMO

OBJECTIVES: The aim of this randomized controlled trial was to investigate a novel sirolimus-coated balloon (SCB) compared with the best investigated paclitaxel-coated balloon (PCB). BACKGROUND: There is increasing clinical evidence for the treatment of coronary de novo disease using drug-coated balloons. However, it is unclear whether paclitaxel remains the drug of choice or if sirolimus is an alternative, in analogy to drug-eluting stents. METHODS: Seventy patients with coronary de novo lesions were enrolled in a randomized, multicenter trial to compare a novel SCB (SeQuent SCB, B. Braun Melsungen; 4 µg/mm2) with a PCB (SeQuent Please, B. Braun Melsungen; 3 µg/mm2). The primary endpoint was angiographic late lumen loss (LLL) at 6 months. Secondary endpoints included major adverse cardiovascular events and individual clinical endpoints such as cardiac death, target lesion myocardial infarction, clinically driven target lesion revascularization, and binary restenosis. RESULTS: Quantitative coronary angiography revealed no differences in baseline parameters. After 6 months, in-segment LLL was 0.01 ± 0.33 mm in the PCB group versus 0.10 ± 0.32 mm in the SCB group. The mean difference between SCB and PCB was 0.08 (95% CI: -0.07 to 0.24). Noninferiority at a predefined margin of 0.35 was shown. However, negative LLL was more frequent in the PCB group (60% of lesions vs 32% in the SCB group; P = 0.019). Major adverse cardiovascular events up to 12 months also did not differ between the groups. CONCLUSIONS: This first-in-human comparison of a novel SCB with a crystalline coating showed similar angiographic outcomes in the treatment of coronary de novo disease compared with a clinically proven PCB. However, late luminal enlargement was more frequently observed after PCB treatment. (Treatment of Coronary De-Novo Stenosis by a Sirolimus Coated Balloon or a Paclitaxel Coated Balloon Catheter Malaysia [SCBDNMAL]; NCT04017364).


Assuntos
Angioplastia Coronária com Balão , Fármacos Cardiovasculares , Doença da Artéria Coronariana , Reestenose Coronária , Angioplastia Coronária com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Humanos , Paclitaxel/efeitos adversos , Estudos Prospectivos , Sirolimo/efeitos adversos , Resultado do Tratamento
14.
Circ Cardiovasc Interv ; 15(9): e012305, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36126132

RESUMO

BACKGROUND: Paclitaxel-coated balloons (PCBs) are a preferred treatment option for coronary in-stent restenosis. To date, data from randomized trials of alternative drug coatings are lacking. The aim of the randomized Malaysian and German-Swiss randomized trials was to investigate a novel sirolimus-coated balloon (SCB) compared with a PCB in in-stent restenosis. METHODS: One hundred one patients with drug-eluting stent in-stent restenosis were enrolled in 2 identical randomized trials comparing the novel SCB (SeQuent SCB, 4 µg/mm²) with the clinically proven PCB (SeQuent Please, 3 µg/mm²). Primary end point was angiographic late lumen loss at 6 months. Secondary end points included procedural success, major adverse cardiac events, and individual clinical end points such as stent thrombosis, cardiac death, target lesion myocardial infarction, clinically driven target lesion revascularization, and binary restenosis. RESULTS: Quantitative coronary angiography revealed no differences in baseline parameters. After 6 months, in-segment late lumen loss was 0.25±0.57 mm in the PCB group versus 0.26±0.60 mm in the SCB group. Mean difference between SCB and PCB was 0.01 (95% CI, -0.23 to 0.24). Noninferiority at a predefined margin of 0.35 was shown. Clinical events up to 12 months did not differ between the groups. CONCLUSIONS: This first-in man comparison of a novel SCB with a crystalline coating showed similar angiographic and clinical outcomes in the treatment of coronary drug-eluting stent in-stent restenosis compared with PCB. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02996318, NCT03242096.


Assuntos
Angioplastia Coronária com Balão , Reestenose Coronária , Stents Farmacológicos , Bifenilos Policlorados , Angioplastia Coronária com Balão/efeitos adversos , Constrição Patológica/induzido quimicamente , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Humanos , Paclitaxel/efeitos adversos , Ensaios Clínicos Controlados Aleatórios como Assunto , Sirolimo/efeitos adversos , Stents , Resultado do Tratamento
15.
CVIR Endovasc ; 5(1): 29, 2022 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-35748962

RESUMO

Sirolimus-coated balloons (SCB) have demonstrated much promise as an alternative drug eluting device to the existing paclitaxel coated balloon platforms for the treatment of peripheral arterial disease (PAD). They have been well tested pre-clinically and have demonstrated anti-restenotic effects as well as clinical safety in its use for treatment of coronary artery disease. The existing approved SCBs have thus far demonstrated good short-term patency (12-months) and did not exhibit any major adverse events or device related shortcomings in its use for treatment of PAD. There are several studies ongoing which aim to further investigate the efficacy of existing SCBs and establish a direct comparison of its outcomes compared with plain balloon angioplasty. Also, SCB utility to salvage failing arteriovenous fistulas for haemodialysis patients has also been explored. We review the current progress made in the establishment of SCB in the treatment of PAD as well as highlight ongoing studies investigating the role of SCB in various settings.

16.
Cardiovasc Revasc Med ; 25: 29-35, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33109476

RESUMO

AIMS: The objective of the study is to assess the efficacy and safety of the novel Magic Touch sirolimus coated-balloon (SCB) when compared to the SeQuent Please Neo paclitaxel coated balloon (PCB) for the treatment of de-novo small vessel coronary artery diseases (SVD). STUDY DESIGN: The TRANSFORM I study is a randomized, multicenter, non-inferiority trial with the intent to enroll a total of 114 patients with a de-novo SVD (≤2.5 mm). Vessel size will be pre-screened by on-line QCA. After successful pre-dilatation without major coronary dissections (type C-F) nor Thrombolysis In Myocardial Infarction trial [TIMI] grade flow ≤2, patients will be enrolled in a 1:1 randomization to receive treatment with either the novel SCB balloon or the comparative PCB balloon. The balloon sizing will be selected according to the lumen-based approach derived from optical coherence tomography (OCT). The primary endpoint is 6-month mean net lumen diameter gain (6-month minimum lumen diameter [MLD] minus baseline MLD) assessed by quantitative coronary analysis (QCA) with non-inferiority margin of 0.3 mm in per-protocol analysis. The clinical follow-up will be conducted up to 1 year. The enrollment started in September 2020 and will complete in April 2021. CONCLUSIONS: The TRANSFORM I trial will assess the efficacy of novel SCB in terms of non-inferiority to conventional PCB with a novel OCT measurement approach in patients with a de-novo SVD. Clinical Trial Registration URL: https://clinicaltrials.gov. Unique identifier: NCT03913832.


Assuntos
Angioplastia Coronária com Balão , Fármacos Cardiovasculares , Doença da Artéria Coronariana , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Humanos , Paclitaxel , Estudos Prospectivos , Sirolimo , Resultado do Tratamento
17.
JACC Cardiovasc Interv ; 12(6): 558-566, 2019 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-30898253

RESUMO

OBJECTIVES: The aim of this randomized controlled trial was to investigate a novel sirolimus-coated balloon (SCB) compared with the best investigated paclitaxel-coated balloon (PCB). BACKGROUND: Treatment of coronary in-stent restenosis (ISR) remains challenging. PCBs are an established treatment option outside the United States with a Class I, Level of Evidence: A recommendation in the European guidelines. However, their efficacy is better in bare-metal stent (BMS) ISR compared with drug-eluting stent (DES) ISR. METHODS: Fifty patients with DES ISR were enrolled in a randomized, multicenter trial to compare a novel SCB (SeQuent SCB, 4 µg/mm2) with a clinically proven PCB (SeQuent Please Neo, 3 µg/mm2) in coronary DES ISR. The primary endpoint was angiographic late lumen loss at 6 months. Secondary endpoints included procedural success, major adverse cardiovascular events, and individual clinical endpoints such as stent thrombosis, cardiac death, target lesion myocardial infarction, clinically driven target lesion revascularization, and binary restenosis. RESULTS: Quantitative coronary angiography revealed no differences in baseline parameters. After 6 months, in-segment late lumen loss was 0.21 ± 0.54 mm in the PCB group versus 0.17 ± 0.55 mm in the SCB group (p = NS; per-protocol analysis). Clinical events up to 12 months also did not differ between the groups. CONCLUSIONS: This first-in-man comparison of a novel SCB with a crystalline coating shows similar angiographic outcomes in the treatment of coronary DES ISR compared with a clinically proven PCB. (Treatment of Coronary In-Stent Restenosis by a Sirolimus [Rapamycin] Coated Balloon or a Paclitaxel Coated Balloon [FIM LIMUS DCB]; NCT02996318).


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Reestenose Coronária/terapia , Paclitaxel/administração & dosagem , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Stents , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Feminino , Humanos , Malásia , Masculino , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Estudos Prospectivos , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
18.
Cardiovasc Revasc Med ; 19(4): 466-470, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29169984

RESUMO

Percutaneous treatment of the unprotected left main trunk (ULM), defined as a vessel without patent bypass graft either to the left circumflex (LCX) or left anterior descending (LAD) artery, has gained a precise role thanks to recent scientific evidence. Although new generation drug-eluting stents have already proven to be safer, there is still a consistent risk of restenosis and late adverse events. The optimal management of a ULM restenosis is still debated. Here we aim at presenting a review of the available data in literature and show our choice for treating it.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/cirurgia , Reestenose Coronária/terapia , Vasos Coronários/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neointima , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Tomografia de Coerência Óptica , Resultado do Tratamento
19.
Cardiovasc Revasc Med ; 18(7): 487-491, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28365415

RESUMO

BACKGROUND AND PURPOSES: Drug-coated balloons (DCB) currently represent an alternative to drug-eluting stents (DES) for the treatment of in-stent restenosis and they are also variably used for small coronary vessel and bifurcation lesion management. All DCB variably elute paclitaxel as an anti-proliferative drug. The first sirolimus coated balloon (SCB) received the CE mark in 2016, but its clinical performance has not been shown yet. METHODS AND RESULTS: FASICO in an all-comer registry of the first consecutive patients with at least one lesion treated with SCB between March and July 2016 at the first European centre that used this device. All patients were prospectively enrolled in a dedicated database. Primary endpoint was procedural success; co-primary endpoint was the rate of major adverse cardiac events at short-term follow-up. The 32 patients (34 lesions) enrolled had at least 6-month clinical follow up available. Forty-five percent had diabetes and indication to PCI was ISR in 47% of the cases. Lesions were always pre-dilated and device deployment was successful in all the cases. Procedural success was achieved in 100% of patients. We observed 3 cases of TLR at follow-up. CONCLUSIONS: SCB shows high immediate technical performance and adequate short-term efficacy and safety. The ongoing EASTBOURNE registry will shed light on mid-and long-term performance of this device in an adequately powered population.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença das Coronárias/terapia , Sirolimo/administração & dosagem , Angioplastia Coronária com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Doença das Coronárias/diagnóstico , Desenho de Equipamento , Feminino , Humanos , Itália , Masculino , Estudos Prospectivos , Sistema de Registros , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA