Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 432
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Gastric Cancer ; 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39028419

RESUMO

BACKGROUND: The significance of reinforcement of the duodenal stump with seromuscular sutures and the effectiveness of reinforced staplers in preventing duodenal stump leakage remain unclear. We aimed to explore the importance of duodenal stump reinforcement and determine the optimal reinforcement method for preventing duodenal stump leakage. METHODS: This retrospective cohort study was conducted between January 1, 2012 and December 31, 2021, with data analyzed between December 1, 2022 and September 30, 2023. This multicenter study across 57 institutes in Japan included 16,475 patients with gastric cancer who underwent radical gastrectomies. Elective open or minimally invasive (laparoscopic or robotic) gastrectomy was performed in patients with gastric cancer. RESULTS: Duodenal stump leakage occurred in 153 (0.93%) of 16,475 patients. The proportions of males, patients aged ≥ 75 years, and ≥ pN1 were higher in patients with duodenal stump leakage than in those without duodenal stump leakage. The incidence of duodenal stump leakage was significantly lower in the group treated with reinforcement by seromuscular sutures or using reinforced stapler than in the group without reinforcement (0.72% vs. 1.19%, p = 0.002). Duodenal stump leakage incidence was also significantly lower in high-volume institutions than in low-volume institutions (0.70% vs. 1.65%, p = 0.047). The rate of duodenal stump leakage-related mortality was 7.8% (12/153). In the multivariate analysis, preoperative asthma and duodenal invasion were identified as independent preoperative risk factors for duodenal stump leakage-related mortality. CONCLUSIONS: The duodenal stump should be reinforced to prevent duodenal stump leakage after radical gastrectomy in patients with gastric cancer.

2.
Int J Colorectal Dis ; 39(1): 51, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38607585

RESUMO

PURPOSE: Three types of circular staplers can be used to perform a colorectal anastomosis: two-row (MCS), three-row (TRCS) and powered (PCS) devices. The objective of this meta-analysis has been to provide the existing evidence on which of these circular staplers would have a lower risk of presenting a leak (AL) and/or anastomotic bleeding (AB). METHODS: An in-depth search was carried out in the electronic bibliographic databases Embase, PubMed and SCOPUS. Observational studies were included, since randomized clinical trials comparing circular staplers were not found. RESULTS: In the case of AL, seven studies met the inclusion criteria in the PCS group and four in the TRCS group. In the case of AB, only four studies could be included in the analysis in the PCS group. The AL OR reported for PCS was 0.402 (95%-confidence interval (95%-CI): 0.266-0.608) and for AB: 0.2 (95% CI: 0.08-0.52). The OR obtained for AL in TRCS was 0.446 (95%-CI: 0.217 to 0.916). Risk difference for AL in PCS was - 0.06 (95% CI: - 0.07 to - 0.04) and in TRCS was - 0.04 (95%-CI: - 0.08 to - 0.01). Subgroup analysis did not report significant differences between groups. On the other hand, the AB OR obtained for PCS was 0.2 (95% CI: 0.08-0.52). In this case, no significant differences were observed in subgroup analysis. CONCLUSION: PCS presented a significantly lower risk of leakage and anastomotic bleeding while TRCS only demonstrated a risk reduction in AL. Risk difference of AL was superior in the PCS than in TRCS.


Assuntos
Neoplasias Colorretais , Grampeadores Cirúrgicos , Humanos , Anastomose Cirúrgica/métodos
3.
Int J Colorectal Dis ; 39(1): 152, 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39331160

RESUMO

PURPOSE: Anastomotic leak (AL) remains the most important complication after left-sided colic anastomoses and technical complications during anastomotic construction are responsible of higher leakage incidence. Powered circular stapler (PCS) in colorectal surgery has been introduced in order to reduce technical errors and post-operative complications due to the manual circular stapler (MCS). METHODS: A systematic review and meta-analysis were performed. An electronic systematic search was performed using Web of Science, PubMed, and Embase of studies comparing PCS and MCS. The incidence of AL, anastomotic bleeding (AB), conversion, and reoperation were assessed. PROSPERO Registration Number: CRD42024512644. RESULTS: Five observational studies were eligible for inclusion reporting on 2379 patients. The estimated pooled Risk Ratios for AL and AB rates following PCS were significantly lower than those observed with MCS (0.44 and 0.23, respectively; both with p < 0.01). Conversion and reoperation rate did not show any significant difference: 0.41 (95% CI 0.09-1.88; p = 0.25) and 0.78 (95% CI 0.33-1.84; p = 0.57); respectively. CONCLUSION: The use of PCS demonstrates a lower incidence of AL and AB compared to MCS but does not exhibit a discernible influence on reintervention or conversion rates. The call for future randomized clinical trials aims to definitively clarify these issues and contribute to further advancements in refining surgical strategies for left-sided colonic resection.


Assuntos
Anastomose Cirúrgica , Fístula Anastomótica , Colo , Grampeadores Cirúrgicos , Humanos , Anastomose Cirúrgica/efeitos adversos , Colo/cirurgia , Fístula Anastomótica/etiologia , Reto/cirurgia , Reoperação , Grampeamento Cirúrgico/efeitos adversos , Viés de Publicação
4.
Colorectal Dis ; 26(2): 348-355, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38158622

RESUMO

AIM: Staplers used in ileocolic anastomosis construction differ in length and height. We assessed the impact of stapler type in creating ileocolic anastomoses on postoperative outcomes. METHODS: This retrospective cohort study of an Institutional Review Board approved database included patients who underwent laparoscopic right colectomy for cancer between January 2011 and August 2021. All patients had construction of extracorporeal antiperistaltic stapled ileocolic anastomosis using a linear cutting stapler. Main outcome measures were short-term (<30 day) morbidity and mortality. RESULTS: In all, 270 patients (136 men; median age 70.2 years) were included. A 75 mm stapler was used in 49 (18.1%) patients, 80 mm in 97 (35.9%) and 100 mm in 124 (45.9%). Blue cartridge (stapler height 3.5 mm) was used in 175 (64.5%) and green cartridge (4.8 mm) in 18 (7%) patients; this information was unavailable in 77 (28.5%) cases. Apical enterotomy closure was performed by linear stapler in 54% and linear cutting stapler in 46%. Apical staple line reinforcement or imbrication suturing was used in 26.3%. The overall postoperative complication rate was 28.9%. The anastomotic leak rate was 2.6%. Independent predictors of complications after laparoscopic right colectomy were older age (OR 1.03, 95%CI 1-1.06; P = 0.01), extended colectomy (OR 2.76, 95%CI 1.07-7.08; P = 0.035) and emergency surgery (OR 4.5, 95%CI 1.3-14.9; P = 0.014). A 100-mm linear cutting stapler was an independent protective factor against postoperative complications (OR 0.3, 95%CI 0.18-0.85; P = 0.019). Stapler height and closure technique of apical enterotomy did not affect postoperative complications. CONCLUSION: Independent predictors of complications after laparoscopic right colectomy were older age, extended colectomy and emergency surgery. Using a 100 mm stapler was an independent protective factor against postoperative complications.


Assuntos
Intestino Delgado , Laparoscopia , Masculino , Humanos , Idoso , Estudos Retrospectivos , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/métodos , Colectomia/efeitos adversos , Colectomia/métodos , Fístula Anastomótica/etiologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Laparoscopia/efeitos adversos , Laparoscopia/métodos
5.
Colorectal Dis ; 26(4): 754-759, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38443753

RESUMO

AIM: Creation of an overlapped anastomosis using handsewn sutures for common enterotomy is very popular in robotic right colectomy (RRC) with intracorpareal anastomosis (IA). The aim of this study is to present a simple method for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in RRC with IA. METHOD: The distal ileum and proximal colon were put in overlapping positions. Enterotomies were created 2 cm proximal to the ileal stump and 8 cm distal to the colonic stump on the antimesenteric side. Subsequently, a 60 mm linear stapler with a reinforced bioabsorbable material was inserted into each lumen and fired. Finally, the bowel was elevated while holding the bioabsorbable material, and the common enterotomy was grasped with the robotic instrument in the middle and closed using a linear stapler with a reinforced bioabsorbable material. RESULTS: This technique was applied to 10 patients with tumours of the caecum, ascending colon, or transverse colon. The median operating time, anastomosis construction time, blood loss, and postoperative stay were 281 min (range 228-459 min), 12 min (range 11-17 min), 10 mL (range 0-110 mL), and 10 days (range 8-15 days), respectively. No adverse intraoperative events were observed. Postoperatively, one patient developed chylous ascites, but there were no other complications. CONCLUSION: The simple technique for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis appears to be safe and feasible.


Assuntos
Implantes Absorvíveis , Anastomose Cirúrgica , Colectomia , Neoplasias do Colo , Íleo , Procedimentos Cirúrgicos Robóticos , Grampeadores Cirúrgicos , Colectomia/métodos , Colectomia/instrumentação , Humanos , Anastomose Cirúrgica/métodos , Anastomose Cirúrgica/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Neoplasias do Colo/cirurgia , Íleo/cirurgia , Procedimentos Cirúrgicos sem Sutura/métodos , Procedimentos Cirúrgicos sem Sutura/instrumentação , Duração da Cirurgia , Colo/cirurgia , Resultado do Tratamento , Grampeamento Cirúrgico/métodos , Grampeamento Cirúrgico/instrumentação , Adulto , Tempo de Internação
6.
World J Surg ; 48(4): 932-942, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38375966

RESUMO

BACKGROUND: Distal pancreatectomy (DP) using linear staplers is widely performed; however, postoperative pancreatic fistulas (POPF) remain an issue. This study aimed to analyze preoperative risk factors for POPF and assess stapler handling. METHODS: We retrospectively analyzed consecutive patients who underwent DP for pancreatic tumors using a linear stapler between 2014 and 2022. Preoperative measurements included pancreas-to-muscle signal intensity ratio (SIR) on fat-suppressed T1-weighted magnetic resonance imaging (MRI). The main outcome was clinically relevant POPF of the 2016 International Study Group of Pancreatic Fistulas definition. The predictive ability of the model was compared with the distal fistula risk score (D-FRS) by using the area under the receiver operating characteristic curve (AUROC). RESULTS: Among the 81 patients, POPF occurred in 31 (38.2%). Multivariate analysis identified computed tomography-measured pancreatic thickness (odds ratio [OR] 1.30, 95% confidence interval [CI] 1.05-1.61, p = 0.009) and SIR on T1-weighted MRI (OR 6.85, 95% CI 1.71-27.4, p = 0.002) as preoperative predictors. A novel preoperative model, "Thickness × MRI (TM)"-index, was established by multiplying these two variables. The TM-index exhibited the highest predictability preoperatively (AUROC 0.757, 95% CI 0.649-0.867). In the intraoperative variable analyses, TM-index (p < 0.001), thin cartridge application (p = 0.032), and short pre-firing compression (p = 0.047) were identified as significant risk factors for POPF. The model's AUROC combined with these two stapler handling methods was higher than D-FRS (0.851 vs. 0.660, p = 0.006). CONCLUSIONS: The novel preoperative model exhibited excellent predictability. Thick cartridge use and long pre-firing compression were protective factors against POPF. This model may facilitate preventive surgical strategy development to reduce POPF.


Assuntos
Pancreatectomia , Neoplasias Pancreáticas , Humanos , Pancreatectomia/efeitos adversos , Pancreatectomia/métodos , Fístula Pancreática/etiologia , Fístula Pancreática/prevenção & controle , Estudos Retrospectivos , Pâncreas/diagnóstico por imagem , Pâncreas/cirurgia , Pâncreas/patologia , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/cirurgia , Neoplasias Pancreáticas/complicações , Fatores de Risco , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle
7.
World J Surg ; 2024 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-39349369

RESUMO

The double-stapled technique is the most common method of colorectal anastomosis. Despite its widespread use, emerging data suggests that this technique may be a risk factor for anastomotic complications, as it is believed that crossing staple lines and resultant dog-ears are potentially weak points that are prone to ischemia and anastomotic leak. Herein, we describe technical variations of single-stapled colorectal anastomoses which surgeons can readily adopt and integrate into their armamentarium of anastomotic techniques.

8.
Langenbecks Arch Surg ; 409(1): 184, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38862717

RESUMO

PURPOSE: Post-operative pancreatic fistula (POPF) remains the main complication after distal pancreatectomy (DP). The aim of this study is to evaluate the potential benefit of different durations of progressive stapler closure on POPF rate and severity after DP. METHODS: Patients who underwent DP between 2016 and 2023 were retrospectively enrolled and divided into two groups according to the duration of the stapler closure: those who underwent a progressive compression for < 10 min and those for ≥ 10 min. RESULTS: Among 155 DPs, 83 (53.5%) patients underwent pre-firing compression for < 10 min and 72 (46.5%) for ≥ 10 min. As a whole, 101 (65.1%) developed POPF. A lower incidence rate was found in case of ≥ 10 min compression (34-47.2%) compared to < 10 min compression (67- 80.7%) (p = 0.001). When only clinically relevant (CR) POPFs were considered, a prolonged pre-firing compression led to a lower rate (15-20.8%) than the < 10 min cohort (32-38.6%; p = 0.02). At the multivariate analysis, a compression time of at least 10 min was confirmed as a protective factor for both POPF (OR: 5.47, 95% CI: 2.16-13.87; p = 0.04) and CR-POPF (OR: 2.5, 95% CI: 1.19-5.45; p = 0.04) development. In case of a thick pancreatic gland, a prolonged pancreatic compression for at least 10 min was significantly associated to a lower rate of CR-POPF compared to < 10 min (p = 0.04). CONCLUSION: A prolonged pre-firing pancreatic compression for at least 10 min seems to significantly reduce the risk of CR-POPF development. Moreover, significant advantages are documented in case of a thick pancreatic gland.


Assuntos
Pancreatectomia , Fístula Pancreática , Complicações Pós-Operatórias , Grampeamento Cirúrgico , Humanos , Fístula Pancreática/prevenção & controle , Fístula Pancreática/etiologia , Pancreatectomia/efeitos adversos , Pancreatectomia/métodos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Grampeamento Cirúrgico/métodos , Grampeadores Cirúrgicos , Adulto , Fatores de Tempo , Neoplasias Pancreáticas/cirurgia
9.
Surg Today ; 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38691222

RESUMO

PURPOSES: Polyglycolic acid (PGA) sheets, fibrin glue, and staple line reinforcement are frequently used to prevent air leakage during lung resection. However, the optimal staple-line reinforcement method remains unclear. METHODS: Cranial lung lobes of pigs were used to evaluate different staple line reinforcement methods (n = 6). Ventilator-assisted manometry was used to measure the maximum resistance pressure at the time of rupture of the lung tissue after stapling. RESULTS: The mean maximum resistance pressures at the time of lung tissue rupture after using the stapler alone, stapler with PGA sheet and fibrin glue, and stapler with reinforcement were 38.0 cmH2O, 51.3 cmH2O, and 62.7 cmH2O, respectively. A significant increase in the maximum resistance pressure was observed with stapler reinforcement (P < 0.001), while the differences between the other groups were not statistically significant (P = 0.055, P = 0.111). A histological assessment revealed disruption of alveolar structures near the needle-stitching site in the stapler alone, and in the stapler with PGA sheet and fibrin glue groups. Pleural rupture near the staple line was observed in the stapler with reinforcement group. CONCLUSIONS: The maximum resistance pressure before air leakage was significantly higher when using a stapler with reinforcement than when using a stapler alone.

10.
Surg Today ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38635055

RESUMO

PURPOSES: Robot-assisted thoracoscopic (RATS) segmentectomy is becoming increasingly common because of the expanded indications for segmentectomy and the widespread adoption of robotic surgery. The precise division of the intersegmental plane is necessary to ensure oncologic margins from the tumor and to preserve the lung function. In this study, we present a strategy for accurately dividing the intersegmental plane using a robotic stapler and review the surgical outcomes. METHODS: RATS portal segmentectomy was performed using the Da Vinci Xi system and the intersegmental plane was dissected using a robotic stapler. We evaluated the perioperative outcomes in 92 patients who underwent RATS portal segmentectomy between May 2020 and January 2023. These results were compared with those of 82 patients who underwent complete video-assisted thoracoscopic surgery (CVATS) during the same period. RESULTS: The operative and console times were 162 and 97 min, respectively. No intraoperative complications occurred, and postoperative complications were observed in four cases (4.3%). The operative time, blood loss, postoperative complications, and maximum incision size were significantly lower in the RATS group than in the CVATS group. However, RATS requires a significantly higher number of staplers than CVATS. CONCLUSIONS: The division of the intersegmental plane using a robotic stapler in RATS portal segmentectomy was, therefore, found to be safe and effective.

11.
Am J Otolaryngol ; 45(4): 104261, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38574513

RESUMO

OBJECTIVE: To compare clinical outcomes in patients with and without history of tobacco use who underwent Zenker's diverticulotomy (ZD). STUDY DESIGN: Single institution retrospective review. SETTING: Tertiary care academic hospital. METHODS: A retrospective review of patients who underwent ZD via an open stapler, rigid endoscopic CO2 laser, stapler or harmonic scalpel, and flexible endoscopic technique from January 2006 to December 2020 was performed. Data were abstracted for patient demographics, diverticular features, and rates of adverse events and symptomatic recurrence. RESULTS: Out of 424 patients, 146 (34.4 %) had a history of tobacco use: 126 (29.7 %) were former smokers, and 20 (4.7 %) were active smokers. In univariable cross-sectional analyses, the likelihood of postoperative bleeding, perforation, emergency department visits, unplanned readmission, or recurrence did not demonstrate an association with tobacco use history even after adjustment for age, sex, and surgical approach. Similarly, in Cox Proportional Hazards regression, tobacco use was not associated with an increased risk of recurrence, even after correcting for age, sex, and type of surgery. The median time to recurrence observed in our cohort was 11.5 years amongst non-smokers, 8.7 years amongst former smokers, and 1.2 years amongst active smokers (p = 0.94). CONCLUSIONS: There were no significant differences in post-operative adverse events or frequency of recurrence of ZD between active, former, and non-smokers. Although underpowered and not statistically significant, median time to recurrence appears to be shorter in smokers when compared with former and non-smokers following surgery.


Assuntos
Recidiva , Divertículo de Zenker , Humanos , Divertículo de Zenker/cirurgia , Masculino , Feminino , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Uso de Tabaco/efeitos adversos , Estudos Transversais
12.
Eur Arch Otorhinolaryngol ; 281(8): 4273-4280, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38739184

RESUMO

OBJECTIVES: The aim of the current study was to evaluate the functional outcomes of stapler pharyngeal closure after total laryngectomy by the incidence of PCT and assessment of swallowing after surgery. In addition, the study aimed to evaluate the oncological outcomes in terms of patients' survival rates. METHODS: This randomized clinical trial was conducted on 58 patients with advanced laryngeal carcinoma who underwent total laryngectomy. Patients were randomly assigned to two groups according to the method of pharyngeal repair after laryngectomy: manual closure group (n = 28), and stapler group (n = 30). Functional and oncological outcomes were assessed and compared. RESULTS: The incidence of pharyngocutaneous fistula was significantly less in the stapler group. Additionally, operative time was significantly shorter and swallowing function was better in the stapler group compared to the manual group. There was no statistically significant difference between groups regarding survival rates. CONCLUSION: The stapler is a reliable method for pharyngeal closure after total laryngectomy if the limits of its indications regarding the primary tumor are considered. Stapler closure decreases the incidence of PCF and decreases the surgical time. Good swallowing outcomes are achieved without compromising the oncological outcomes.


Assuntos
Neoplasias Laríngeas , Laringectomia , Humanos , Laringectomia/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Neoplasias Laríngeas/cirurgia , Idoso , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Doenças Faríngeas/etiologia , Doenças Faríngeas/prevenção & controle , Faringe/cirurgia , Duração da Cirurgia , Resultado do Tratamento , Grampeadores Cirúrgicos , Adulto , Fístula Cutânea/etiologia , Fístula Cutânea/prevenção & controle , Fístula Cutânea/epidemiologia , Grampeamento Cirúrgico/métodos , Deglutição/fisiologia
13.
BMC Surg ; 24(1): 130, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38698365

RESUMO

BACKGROUND: Anastomosis configuration is an essential step in treatment to restore continuity of the gastrointestinal tract following bowel resection in patients with Crohn's disease (CD). However, the association between anastomotic type and surgical outcome remains controversial. This retrospective study aimed to compare early postoperative complications and surgical outcome between stapler and handsewn anastomosis after bowel resection in Crohn's disease. METHODS: Between 2001 and 2018, a total of 339 CD patients underwent bowel resection with anastomosis. Patient characteristics, intraoperative data, early postoperative complications, and outcomes were analyzed and compared between two groups of patients. Group 1 consisted of patients with stapler anastomosis and group 2 with handsewn anastomosis. RESULTS: No significant difference was found in the incidence of postoperative surgical complications between the stapler and handsewn anastomosis groups (25% versus 24.4%, p = 1.000). Reoperation for complications and postoperative hospital stay were similar between the two groups. CONCLUSION: Our analysis showed that there were no differences in anastomotic leak, nor postoperative complications, mortality, reoperation for operative complications, or postoperative hospital stay between the stapler anastomosis and handsewn anastomosis groups.


Assuntos
Anastomose Cirúrgica , Doença de Crohn , Complicações Pós-Operatórias , Grampeamento Cirúrgico , Humanos , Doença de Crohn/cirurgia , Feminino , Masculino , Anastomose Cirúrgica/métodos , Estudos Retrospectivos , Adulto , Grampeamento Cirúrgico/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Pessoa de Meia-Idade , Técnicas de Sutura , Reoperação/estatística & dados numéricos , Resultado do Tratamento , Tempo de Internação/estatística & dados numéricos , Fístula Anastomótica/epidemiologia , Fístula Anastomótica/etiologia , Adulto Jovem
14.
Tech Coloproctol ; 28(1): 76, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38954099

RESUMO

BACKGROUND: Colorectal anastomotic leakage causes severe consequences for patients and healthcare system as it will lead to increased consumption of hospital resources and costs. Technological improvements in anastomotic devices could reduce the incidence of leakage and its economic impact. The aim of the present study was to assess if the use of a new powered circular stapler is cost-effective. METHOD: This observational study included patients undergoing left-sided circular stapled colorectal anastomosis between January 2018 and December 2021. Propensity score matching was carried out to create two comparable groups depending on whether the anastomosis was performed using a manual or powered circular device. The rate of anastomotic leakage, its severity, the consumption of hospital resources, and its cost were the main outcome measures. A cost-effectiveness analysis comparing the powered circular stapler versus manual circular staplers was performed. RESULTS: A total of 330 patients were included in the study, 165 in each group. Anastomotic leakage rates were significantly different (p = 0.012): 22 patients (13.3%) in the manual group versus 8 patients (4.8%) in the powered group. The effectiveness of the powered stapler and manual stapler was 98.27% and 93.69%, respectively. The average cost per patient in the powered group was €6238.38, compared with €9700.12 in the manual group. The incremental cost-effectiveness ratio was - €74,915.28 per patient without anastomotic complications. CONCLUSION: The incremental cost of powered circular stapler compared with manual devices was offset by the savings from lowered incidence and cost of management of anastomotic leaks.


Assuntos
Anastomose Cirúrgica , Fístula Anastomótica , Colo , Análise Custo-Benefício , Reto , Grampeadores Cirúrgicos , Grampeamento Cirúrgico , Humanos , Fístula Anastomótica/prevenção & controle , Fístula Anastomótica/economia , Fístula Anastomótica/etiologia , Feminino , Grampeadores Cirúrgicos/economia , Masculino , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/economia , Anastomose Cirúrgica/instrumentação , Anastomose Cirúrgica/métodos , Pessoa de Meia-Idade , Idoso , Incidência , Grampeamento Cirúrgico/economia , Grampeamento Cirúrgico/métodos , Grampeamento Cirúrgico/efeitos adversos , Grampeamento Cirúrgico/instrumentação , Colo/cirurgia , Reto/cirurgia , Pontuação de Propensão , Adulto , Análise de Custo-Efetividade
15.
Tech Coloproctol ; 28(1): 48, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38619626

RESUMO

BACKGROUND: In elderly patients with external full-thickness rectal prolapse (EFTRP), the exact differences in postoperative recurrence and functional outcomes between laparoscopic ventral mesh rectopexy (LVMR) and perineal stapler resection (PSR) have not yet been investigated. METHODS: We conducted a retrospective multicenter study on 330 elderly patients divided into LVMR group (n = 250) and PSR (n = 80) from April 2012 to April 2019. Patients were evaluated before and after surgery by Wexner incontinence scale, Altomare constipation scale, and patient satisfaction questionnaire. The primary outcomes were incidence and risk factors for EFTRP recurrence. Secondary outcomes were postoperative incontinence, constipation, and patient satisfaction. RESULTS: LVMR was associated with fewer postoperative complications (p < 0.001), lower prolapse recurrence (p < 0.001), lower Wexner incontinence score (p = 0.03), and lower Altomare's score (p = 0.047). Furthermore, LVMR demonstrated a significantly higher surgery-recurrence interval (p < 0.001), incontinence improvement (p = 0.019), and patient satisfaction (p < 0.001) than PSR. Three and 13 patients developed new symptoms in LVMR and PSR, respectively. The predictors for prolapse recurrence were LVMR (associated with 93% risk reduction of recurrence, OR 0.067, 95% CI 0.03-0.347, p = 0.001), symptom duration (prolonged duration was associated with an increased risk of recurrence, OR 1.131, 95% CI 1.036-1.236, p = 0.006), and length of prolapse (increased length was associated with a high recurrence risk (OR = 1.407, 95% CI = 1.197-1.655, p < 0.001). CONCLUSIONS: LVMR is safe for EFTRP treatment in elderly patients with low recurrence, and improved postoperative functional outcomes. TRIAL REGISTRATION: Clinical Trial.gov (NCT05915936), retrospectively registered on June 14, 2023.


Assuntos
Laparoscopia , Prolapso Retal , Idoso , Humanos , Prolapso Retal/cirurgia , Estudos Retrospectivos , Telas Cirúrgicas , Laparoscopia/efeitos adversos , Constipação Intestinal
16.
Aesthetic Plast Surg ; 48(16): 3137-3146, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38769148

RESUMO

BACKGROUND: Fleur-de-lis panniculectomy (FDL), a contouring technique involving vertical and horizontal tissue resections, often involves longer operative times and potential complications. This study assessed operative time, postoperative outcomes, and patient-reported quality of life (PRO) with Insorb® Absorbable Subcuticular Skin Stapler versus traditional sutures during FDL. METHODS: A retrospective review from 2015 to 2022 of FDL patients excluded those with complex concomitant procedures. Demographics, operative details, and surgical outcomes were compared between patients using the dermal stapler and those with suture-only closures. RESULTS: Forty subjects were identified, with 25 (62.5%) in the dermal stapler cohort. The dermal stapler significantly reduced total procedure time (66.76 vs. 125.33 min, p < 0.05). There were no significant differences in surgical site occurrences, aesthetic outcomes, readmissions, or reoperations. Multivariate regression analysis further highlighted the choice of closure technique as an independent predictor of operative time, with traditional sutures indicating a significantly increased operative time compared to using the dermal stapler (AOR 76.53, CI 38.11-114.95, p < 0.001). Regarding PROs, both groups saw improvements across multiple BODY-Q domains, but the dermal stapler group reported greater enhancements (six out of nine domains vs. three for sutures). CONCLUSION: The absorbable dermal stapler significantly reduces FDL operative time without increasing wound healing or aesthetic dissatisfaction incidents and maintains comparable quality-of-life improvements to standard suture closure. LEVEL OF EVIDENCE III: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors https://link.springer.com/journal/00266 .


Assuntos
Abdominoplastia , Estética , Qualidade de Vida , Grampeadores Cirúrgicos , Grampeamento Cirúrgico , Humanos , Estudos Retrospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Abdominoplastia/métodos , Adulto , Grampeamento Cirúrgico/métodos , Resultado do Tratamento , Duração da Cirurgia , Estudos de Coortes , Implantes Absorvíveis , Técnicas de Sutura/instrumentação
17.
Int Wound J ; 21(3): e14751, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38472132

RESUMO

Pharyngocutaneous fistula (PCF) is a major complication after total laryngectomy, with significant morbidity and mortality. Whether mechanical stapler closure of the pharynx reduces fistula rates compared to hand-sewn techniques remains unclear. We conducted an updated systematic review and meta-analysis to clarify this question. Five databases were systematically searched from inception through November 2023 for studies comparing stapler versus suture closure for fistula outcomes after laryngectomy. Odds ratios (OR) were pooled using random-effects models and fixed-effects models. Subgroup and sensitivity analyses were performed. Risk of bias was appraised using NHLBI tools. Nine studies with 803 patients were included. Mechanical closure significantly reduced fistula incidence versus suture closure (OR = 0.57, 95% CI 0.34-0.95, p = 0.03). Subgroup analysis found that stapling's protective effect varied by patient age, country/region, linear stapler size and female percentage. Stapling reduced fistula odds by 80% in the Turkey subgroup (OR = 0.20, 95% CI 0.09-0.50) but showed no benefit in other regions. Patients <60 years showed an 84% fistula reduction with stapling (OR = 0.17, 95% CI 0.06-0.45), whereas older subgroups did not. Linear stapler size of 60 mm significantly reduced fistula occurrence while 75 mm did not. There was no evidence that low female percentage mitigated stapling benefits. Mechanical stapler closure after total laryngectomy meaningfully reduces the likelihood of postoperative PCF formation compared to hand-sewn closure, especially for patients younger than 60 years old. The absolute risk reduction supports its utility to prevent this complication.


Assuntos
Fístula Cutânea , Doenças Faríngeas , Técnicas de Fechamento de Ferimentos , Humanos , Fístula Cutânea/etiologia , Fístula Cutânea/cirurgia , Laringectomia/efeitos adversos , Doenças Faríngeas/etiologia , Doenças Faríngeas/cirurgia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Técnicas de Sutura
18.
Zhonghua Nan Ke Xue ; 30(5): 430-434, 2024 May.
Artigo em Chinês | MEDLINE | ID: mdl-39210492

RESUMO

OBJECTIVE: To explore the effect of the "internet + health education system" in nursing care after stapler circumcision. METHODS: A total of 260 patients underwent stapler circumcision in the Outpatient Department of our hospital from January 2022 to July 2022, of whom 130 received routine nursing after operation (the control group), and the other 130 internet + medical nursing service based on the internet + health education system (the experimental group). We followed up the patients on the 1st, 3rd, 7th and 30th day after surgery, recorded their Visual Analogue Scale (VAS) scores within 24 hours postoperatively, their satisfaction scores with surgery and nursing, the incidence of complications and falloff of the stapler nails, and compared them between the two groups. RESULTS: The postoperative VAS scores of the patients and the incidences of postoperative edema, bleeding, infection and other complications were significantly lower (P < 0.05), the falloff of the stapler nails markedly sooner, and the patients' satisfaction scores with surgery and nursing service remarkably higher (P < 0.05) in the experimental than in the control group (P < 0.05). CONCLUSION: The application of the internet + health education system in nursing care after stapler circumcision can impart relevant knowledge to the patients, enhance their self-care ability, effectively reduce postoperative complications, and improve the patients' satisfaction with surgery and nursing service.


Assuntos
Circuncisão Masculina , Internet , Humanos , Masculino , Circuncisão Masculina/instrumentação , Circuncisão Masculina/efeitos adversos , Educação em Saúde/métodos , Satisfação do Paciente , Cuidados de Enfermagem , Complicações Pós-Operatórias/prevenção & controle , Período Pós-Operatório
19.
Khirurgiia (Mosk) ; (4): 29-37, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38634581

RESUMO

OBJECTIVE: To evaluate the short-term outcomes of mechanical and hand-sewn laparoscopic one-anastomosis mini-gastric bypass. MATERIAL AND METHODS: There were 233 patients who underwent laparoscopic one-anastomosis mini-gastric bypass. Short-term results were analyzed in groups of mechanical (the first group, n=108) and hand-sewn (the second group, n=125) gastrojejunostomy. No significant between-group differences in baseline data were detected (demographic characteristics, body mass index, comorbidity and previous abdominal surgeries). RESULTS: Surgery time and blood loss were similar in both groups. Intraoperative morbidity was 7.2-10.2% (p=0.485). All complications required no surgical conversion (Satava-Kazaryan grade I). Overall postoperative morbidity was 16.0-21.3% (p=0.314). Most events corresponded to Accordion grade I and had no significant effect on hospital-stay. CONCLUSION: This study revealed no significant differences in short-term outcomes after laparoscopic one-anastomosis gastric bypass with mechanical and hand-sewn gastrojejunostomy. Further study of long-term clinical outcomes is necessary.


Assuntos
Derivação Gástrica , Laparoscopia , Obesidade Mórbida , Humanos , Derivação Gástrica/métodos , Laparoscopia/métodos , Técnicas de Sutura/efeitos adversos , Anastomose Cirúrgica/efeitos adversos , Obesidade Mórbida/cirurgia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos
20.
BJU Int ; 132(3): 239-251, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37017627

RESUMO

OBJECTIVE: To assess the safety of vascular closure devices in living-donor nephrectomy (LDN), as staplers and non-transfixion techniques (polymer locking and metal clips) are the methods employed to secure the renal vessels during laparoscopic and robotic LDN, but the use of clips has come into question since the United States Food and Drug Administration and manufacturers issued a contraindication. METHODS: A systematic review and meta-analysis were conducted to assess the safety of vascular closure devices (International Prospective Register of Systematic Reviews [PROSPERO] registration: CRD42022364349). The PubMed, Scopus, the Excerpta Medica dataBASE (EMBASE), and the Literatura Latino-Americana e do Caribe em Ciências da Saúde (LILACS) databases were searched in September 2022. For comparative and non-comparative studies, incidence estimates and odds ratios (ORs), respectively, for the main variables regarding safety of vascular closure devices were pooled by using random effects meta-analyses. Quality assessment of the included comparative studies was conducted using the Risk Of Bias In Non-randomised Studies of Interventions (ROBINS-I) tool. RESULTS: Of the 863 articles obtained, data were retrieved from 44 studies, which included 42 902 patients. In non-comparative studies, the pooled estimate rates for device failure, severe haemorrhage rate, conversion to open surgery, and mortality were similar for both clips and staplers. Regarding the meta-analyses for comparative studies (three studies), there were no significant differences between the two groups for the severe haemorrhage rate (OR 0.57, 95% confidence interval [CI] 0.18-1.75; P = 0.33), conversion to open surgery (OR 0.35, 95% CI 0.08-1.54; P = 0.16), or death rate (OR 3.64, 95% CI 0.47-28.45; P = 0.22). Based on weak evidence, device failure was lower in the polymer clip group (OR 0.41, 95% CI 0.23-0.75; P = 0.00). CONCLUSIONS: This study has confirmed that there is no evidence for the superiority of any vascular closure device in terms of safety in LDN. Standardised recommendations for vascular control in this context should be carefully designed and prospectively evaluated.


Assuntos
Dispositivos de Oclusão Vascular , Estados Unidos , Humanos , Doadores Vivos , Nefrectomia/métodos , Polímeros , Hemorragia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA