Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 221
Filtrar
1.
J Surg Oncol ; 2024 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-39257241

RESUMO

BACKGROUND: Surgery has been the standard procedure for resectable primary LC. Survival after stereotactic body radiation therapy, another treatment, is significantly biased due to preponderance of data from patients deemed unsuitable for surgery. We examined survival of patients refusing surgery in favor of radiation therapy. METHODS: We used the Surveillance, Epidemiology, and End Results database to identify patients with primary Stage I NSCLC diagnosed between 2007 and 2016. Patients were excluded if it was unknown if they were recommended for surgery or if surgery was contraindicated. Multiple predictors were assessed: radiation versus surgery, age at diagnosis, sex, race/ethnicity, health insurance status, marital status, tumor size, and histology. A multivariate analysis was performed to estimate hazard ratios and generate Kaplan-Meier survival curves. RESULTS: When adjusted for confounding variables, survival was greater for patients undergoing surgical resection than those refusing surgery in favor of radiation (HRadj 2.66; 95% CI: 2.27-3.11, p < 0.001) or for those receiving no standardized treatment (HRadj 4.43; 95% CI: 3.57-5.50, p < 0.001). CONCLUSIONS: SBRT is an effective treatment for inoperable early LC but there is limited data comparing outcomes against surgical resection. When eligible for both, patients refusing surgery and choosing radiation had worse survival when adjusting for variables including age, tumor size, and histology, and suggests that surgical resection is a superior treatment modality.

2.
Curr Treat Options Oncol ; 25(5): 605-616, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38573430

RESUMO

OPINION STATEMENT: The treatment of oligometastatic genitourinary cancers is a rapidly advancing field with ablative radiotherapy as one of the critical treatment components. The oligometastatic disease state, which can be defined as 1-5 metastatic sites with a controlled primary, represents a distinct clinical state where comprehensive ablative local therapies may provide improved outcomes. Enhanced imaging has increased the number of patients identified with oligometastatic disease. Evidence for improved outcomes with metastasis-directed therapy (MDT) in oligometastatic genitourinary cancers is increasing, and previously published outcome data continues to mature with an increasing body of prospective data to inform the role of MDT in histology-specific settings or in the context of systemic therapy. In select patients, MDT can offer benefits beyond improved local control and allow for time off of systemic therapy, prolonged time until next therapy, or even the hope of cure. However, treatment decisions for locally ablative therapy must be balanced with consideration towards safety. There are exciting advances in technologies to target and adapt treatment in real-time which have expanded options for safer delivery and dose escalation to metastatic targets near critical organs at risk. The role of systemic therapies in conjunction with MDT and incorporation of tumor genetic information to further refine prognostication and treatment decision-making in the oligometastatic setting is actively being investigated. These developments highlight the evolving field of treatment of oligometastatic disease. Future prospective studies combining MDT with enhanced imaging and integrating MDT with evolving systemic therapies will enable the optimal selection of patients most likely to benefit from this "all-or-none" approach and reveal settings in which a combination of therapies could result in synergistic outcomes.


Assuntos
Metástase Neoplásica , Neoplasias Urogenitais , Humanos , Neoplasias Urogenitais/terapia , Neoplasias Urogenitais/diagnóstico , Neoplasias Urogenitais/patologia , Gerenciamento Clínico , Terapia Combinada/métodos , Resultado do Tratamento , Tomada de Decisão Clínica
3.
Radiat Environ Biophys ; 63(3): 423-431, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38969869

RESUMO

This retrospective study was performed to evaluate plan quality and treatment delivery parameters of stereotactic body radiation therapy (SBRT) for prostate cancer. The study utilized different isocentric modulated techniques: intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) using 6 MV flattening filter (FF) and 10 MV flattening filter-free beams (FFF). Fifteen retrospective prostate cancer patients were selected for this study. Sixty plans were created with an SBRT-prescribed dose of 36.25 Gy delivered in five fractions. Planning target volume (PTV) coverage, plan quality indices, doses delivered to organs at risk (OARs), and treatment delivery parameters were compared for all plans. It turned out that VMAT plans, particularly those using the FFF beam, provided superior target conformality and a steeper dose gradient as compared to IMRT plans. Additionally, VMAT plans showed better OARs sparing compared to IMRT plans. However, IMRT plans delivered a lower maximum dose to the target than VMAT plans. Importantly, the VMAT plans resulted in reduced treatment delivery parameters, including beam on time (BOT), monitor unit (MU), and modulation factor (MF), compared to IMRT plans. Furthermore, a statistically significant difference was observed in BOT and mean body dose between FF and FFF beams, with FFF beams showing superior performance. Considering all results, VMAT using 10 MV (FFF) is suggested for treating prostate cancer patients with SBRT. This offers the fastest delivery in addition to maintaining the highest plan quality.


Assuntos
Neoplasias da Próstata , Radiocirurgia , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Masculino , Humanos , Neoplasias da Próstata/radioterapia , Radioterapia de Intensidade Modulada/métodos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos , Dosagem Radioterapêutica , Radiometria , Órgãos em Risco/efeitos da radiação
4.
J Appl Clin Med Phys ; : e14488, 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39226472

RESUMO

PURPOSE: The aim of this study is to determine the effect of forcing and filling the electron density (ED) to 1.0 of the planning target volume (PTV) overdose distribution in lung SBRT treatment leading to shortening patient treatment time and increasing patient comfort by reducing MU/fraction due to ED manipulation effect. METHODS: In this study, 36 lung SBRT plans of 12 suitable patients who prescribed a total dose of 50 Gy in five fractions were generated with Monaco v.5.10 TPS using the Monte Carlo (MC) algorithm and volumetric modulated arc therapy (VMAT) technique by PTV ED values forcing as well as filling to 1.0 and comparatively assessed. The first group of plans was created by using the patient's original ED, second and third groups of plans were reoptimized by forcing and filling the ED of PTV to 1.0, respectively, therefore acquiring a new dose distribution which lead to comparatively assessment the effects of changes in ED on PTV and OAR doses. RESULTS: Assessment of treatment plans revealed that mean MU/fx numbers were decreased by 76% and 75.25% between Groups 1 and 2, Groups 1 and 3, respectively. The number of segments was also reduced in Group 1 by up to 15% compared with Groups 2 and 3. Maximum HI and CI differences for PTV between Groups 1 and 2 were less than 1% and Groups 1 and 3 were 1.5% which indicates all 3 group plans were comparable in terms of dose distribution within PTV. CONCLUSIONS: Forcing and filling the ED of PTV to 1.0 strategy has provided reduced a number of segments and MU/fx without a significant change in PTV mean and maximum doses, thereby decreasing treatment time and patient discomfort during treatment. This process should be considered in line of a potential number of patients as well as prescribed dose and MU/fx numbers.

5.
Cancer ; 129(6): 956-965, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36571507

RESUMO

BACKGROUND: This study was aimed at developing and validating a decision-making tool predictive of overall survival (OS) for patients receiving stereotactic body radiation therapy (SBRT) for spinal metastases. METHODS: Three hundred sixty-one patients at one institution were used for the training set, and 182 at a second institution were used for external validation. Treatments most commonly involved one or three fractions of spine SBRT. Exclusion criteria included proton therapy and benign histologies. RESULTS: The final model consisted of the following variables and scores: Spinal Instability Neoplastic Score (SINS) ≥ 6 (1), time from primary diagnosis < 21 months (1), Eastern Cooperative Oncology Group (ECOG) performance status = 1 (1) or ECOG performance status > 1 (2), and >1 organ system involved (1). Each variable was an independent predictor of OS (p < .001), and each 1-point increase in the score was associated with a hazard ratio of 2.01 (95% confidence interval [CI], 1.79-2.25; p < .0001). The concordance value was 0.75 (95% CI, 0.71-0.78). The scores were discretized into three groups-favorable (score = 0-1), intermediate (score = 2), and poor survival (score = 3-5)-with 2-year OS rates of 84% (95% CI, 79%-90%), 46% (95% CI, 36%-59%), and 21% (95% CI, 14%-32%), respectively (p < .0001 for each). In the external validation set (182 patients), the score was also predictive of OS (p < .0001). Increasing SINS was predictive of decreased OS as a continuous variable (p < .0001). CONCLUSIONS: This novel score is proposed as a decision-making tool to help to optimize patient selection for spine SBRT. SINS may be an independent predictor of OS.


Assuntos
Radiocirurgia , Neoplasias da Coluna Vertebral , Humanos , Seguimentos , Coluna Vertebral/cirurgia , Neoplasias da Coluna Vertebral/secundário
6.
World J Urol ; 41(12): 3889-3894, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37924333

RESUMO

BACKGROUND: Recent data have found an overall survival benefit from prostate-directed radiotherapy in patients with low-volume metastatic prostate cancer. Prostate SBRT is an attractive treatment in this setting and may be optimised with MR-guided adaptive treatment. Here, we share our institutional experience delivering stereotactic MR-guided adaptive prostate SBRT (SMART) for patients with low-volume metastatic disease. METHODS: We reviewed patients with low-volume metastatic disease who received prostate SMART from October 2019 to December 2021 on a 0.35T MR-Linac. The cohort included 14 patients. Genitourinary (GU) and gastrointestinal (GI) toxicities were assessed using CTCAE v 5.0. Progression was defined as a change in systemic or hormonal therapy regimen as a result of PSA rise or disease progression. RESULTS: The median follow-up time was 29 months. Seven patients had hormone sensitive prostate cancer and 7 had castrate resistant prostate cancer (CRPC). 13 patients received 36.25 Gy in 5 fractions and one patient received 33 Gy in 5 fractions. At the time of last follow-up, 11 patients had not experienced progression and three patients, all with CRPC, had experienced progression. No patients developed local progression in the prostate after SMART. One patient experienced acute grade 2 urinary toxicity (7%) and no patients experienced acute grade 2 GI toxicity (0%). No grade 3 + acute toxicities were observed. CONCLUSIONS: Prostate SMART was found to be well tolerated and all patients had local control of disease within the prostate at the time of last follow-up. Prostate SMART may represent a low-risk and well-tolerated approach for delivering prostate-directed radiotherapy for patients with limited metastatic disease.


Assuntos
Neoplasias de Próstata Resistentes à Castração , Neoplasias da Próstata , Radiocirurgia , Humanos , Masculino , Próstata/patologia , Antígeno Prostático Específico , Neoplasias da Próstata/patologia , Sistema Urogenital
7.
J Appl Clin Med Phys ; 24(12): e14147, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37672210

RESUMO

OBJECTIVES: As an alternative to conventional compression amidst the COVID-19 pandemic, we developed a contactless motion management strategy. By increasing the patient's breathing rate to induce shallow breathing with the aid of a metronome, our hypothesis is that the motion magnitude of the target may be minimized without physical contact or compression. METHODS: Fourteen lung stereotactic body radiation therapy (SBRT) patients treated under fast shallow-breathing (FSB) were selected for inclusion in this retrospective study. Our proposed method is called shallow kinetics induced by a metronome (SKIM). We induce FSB by setting the beats-per-minute (BPM) high (typically in the range of 50-60). This corresponded to a patient breathing rate of 25-30 (breathing) cycles per minute. The magnitude of target motion in 3D under SKIM was evaluated using 4DCT datasets. Comparison with free breathing (FB) 4DCT was also made for a subset for which FB data available. RESULTS: The overall effectiveness of SKIM was evaluated with 18 targets (14 patients). Direct comparison with FB was performed with 12 targets (10 patients). The vector norm mean ± SD value of motion magnitude under SKIM for 18 targets was 8.2 ± 4.1 mm. The mean ± SD metronome BPM was 54.9 ± 4.0 in this group. The vector norm means ± SD values of target motion for FB and SKIM in the 12 target sub-group were 14.6 ± 8.5 mm and 9.3 ± 3.7 mm, respectively. The mean ± SD metronome BPM for this sub-group was 56.3 ± 2.5. CONCLUSION: Compared with FB, SKIM can significantly reduce respiratory motion magnitude of thoracic targets. The difference in maximum motion reduction in the overall vector norm, S-I, and A-P directions was significant (p = 0.033, 0.042, 0.011). Our proposed method can be an excellent practical alternative to conventional compression due to its flexibility and ease of implementation.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Humanos , Estudos Retrospectivos , Pandemias , Movimento (Física) , Respiração , Pulmão , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Radiocirurgia/métodos
8.
J Appl Clin Med Phys ; 23(1): e13458, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34845817

RESUMO

PURPOSE: Halcyon linear accelerators employ intensity-modulated radiation therapy (IMRT) and stereotactic body radiation therapy (SBRT) techniques. The Halcyon offers translational, but not rotational, couch correction, which only allows a 3 degrees of freedom (3-DOF) correction. In contrast, the TrueBeam (TB) linear accelerator offers full 6-DOF corrections. This study aims to evaluate the difference in treatment plan quality for single thoracic or lumbar vertebral segment SBRT between the Halcyon and TB linear accelerators. In addition, this study will also investigate the effect of patient rotational setup errors on the final plan quality. METHODS: We analyzed 20 patients with a single-level spine metastasis located between the T7 and L5 vertebrae near the spinal canal. The median planning target volume was 52.0 cm3 (17.9-138.7 cm3 ). The median tumor diameter in the axial plane was 4.6 cm (range 1.7-6.8 cm), in the sagittal plane was 3.3 cm (range 2-5 cm). The prescription doses were either 12-16 Gy in 1 fraction or 18-24 Gy in 3 fractions. All patients were treated on the TB linear accelerator with a 2.5 mm Multi-Leaf Collimator (MLC) leaf width. Treatment plans were retrospectively created for the Halcyon, which has a 5 mm effective MLC leaf width. The 20 patients had a total of 50 treatments. Analysis of the 50 cone beam computed tomography (CBCT) scans showed average rotational setup errors of 0.6°, 1.2°, and 0.8° in pitch, yaw, and roll, respectively. Rotational error in roll was not considered in this study, as the original TB plans used a coplanar volumetric modulated arc therapy (VMAT) technique, and each 1° of roll will contribute an error of 1/360. If a plan has 3 arcs, the contribution from errors in roll will be < 0.1%. To simulate different patient setup errors, for each patient, 12 CT image datasets were generated in Velocity AI with different rotational combinations at a pitch and yaw of 1°, 2°, and 3°, respectively. We recalculated both the TB and Halcyon plans on these rotated images.  The dosimetric plan quality was evaluated based on the percent tumor coverage, the Conformity Index (CI), Gradient Index (GI), Homogeneity index (HI), the maximum dose to the cord/cauda, and the volume of the cord/cauda receiving 8, 10, and 12 Gy (V8Gy, V10Gy and V12Gy). Paired t-tests were performed between the original and rotated plans with a significance level of 0.05. RESULTS: The Eclipse based VMAT plans on Halcyon achieved a similar target coverage (92.3 ± 3.0% vs. 92.4 ± 3.3%, p = 0.82) and CI (1.0 ± 0.1 vs. 1.1 ± 0.2, p = 0.12) compared to the TB plans. The Gradient index of Halcyon is higher (3.96 ±0.8) than TB (3.85 ±0.7), but not statistically significant. The maximum dose to the spinal cord/cauda was comparable (11.1 ± 2.8 Gy vs. 11.4 ± 3.6 Gy, p = 0.39), as were the V8Gy, V10Gy and V12Gy to the cord/cauda. The dosimetric influence of patient rotational setup error was statistically insignificant for rotations of up to 1° pitch/yaw (with similar target coverage, CI, max cord/cauda dose and V8Gy, V10Gy, V12Gy for cord/cauda). The total number of monitor units (MUs) for Halcyon (4998 ± 1688) was comparable to that of TB (5463 ± 2155) (p = 0.09). CONCLUSIONS: The Halcyon VMAT plans for a single thoracic or lumbar spine metastasis were dosimetrically comparable to the TB plans. Patient rotation within 1° in the pitch and yaw directions, if corrected by translation, resulted in insignificant dosimetric effects. The Halcyon linear accelerator is an acceptable alternative to TB for the treatment of single thoracic or lumbar spinal level metastasis, but users need to be cautious about the patient rotational setup error.  It is advisable to select patients appropriately, including only those with the thoracic or lumbar spine involvement and keeping at least 2 mm separation between the target and the cord/cauda. More margin is needed if the distance between the isocenter and cord/cauda is larger. It is advisable to place the planning isocenter close to the spinal canal to further mitigate the rotational error. SUMMARY: We simulated various scenarios of patient setup errors with different rotational combinations of pitch and yaw with 1°, 2°, and 3°, respectively. Rotation was corrected with translation only to mimic the Halcyon treatment scenario. Using the Halcyon for treating a tumor in a single thoracic or lumbar vertebral segment is feasible, but caution should be noted in patients requiring rotational corrections of > 1° in the absence of 6-DOF correction capabilities.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos , Coluna Vertebral
9.
BMC Cancer ; 21(1): 165, 2021 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-33593311

RESUMO

BACKGROUND: The current management guidelines recommend that patients with borderline resectable pancreatic adenocarcinoma (BRPC) should initially receive neoadjuvant chemotherapy. The addition of advanced radiation therapy modalities, including stereotactic body radiation therapy (SBRT) and intraoperative radiation therapy (IORT), could result in a more effective neoadjuvant strategy, with higher rates of margin-free resections and improved survival outcomes. METHODS/DESIGN: In this single-center, single-arm, intention-to-treat, phase II trial newly diagnosed BRPC will receive a "total neoadjuvant" therapy with FOLFIRINOX (5-fluorouracil, irinotecan and oxaliplatin) and hypofractionated SBRT (5 fractions, total dose of 30 Gy with simultaneous integrated boost of 50 Gy on tumor-vessel interface). Following surgical exploration or resection, IORT will be also delivered (10 Gy). The primary endpoint is 3-year survival. Secondary endpoints include completion of neoadjuvant treatment, resection rate, acute and late toxicities, and progression-free survival. In the subset of patients undergoing resection, per-protocol analysis of disease-free and disease-specific survival will be performed. The estimated sample size is 100 patients over a 36-month period. The trial is currently recruiting. TRIAL REGISTRATION: NCT04090463 at clinicaltrials.gov.


Assuntos
Adenocarcinoma/terapia , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Quimiorradioterapia/métodos , Terapia Neoadjuvante/métodos , Neoplasias Pancreáticas/terapia , Radiocirurgia/métodos , Adenocarcinoma/patologia , Adulto , Idoso , Ensaios Clínicos Fase II como Assunto , Terapia Combinada , Feminino , Seguimentos , Humanos , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/patologia , Prognóstico , Taxa de Sobrevida
10.
JOP ; 22(2): 36-41, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34354555

RESUMO

BACKGROUND: The effects of adjuvant radiation therapy on pancreatic cancer outcomes after resection are not well defined in the literature. METHODS: We abstracted data from the Surveillance, Epidemiology, and End Result (SEER) database to explore the impact of adjuvant radiation on cancer-specific survival in pancreatic cancer patients who received surgical resection. RESULTS: A total of 10,224 patients met our inclusion criteria with 6768 (66.2%) patients treated with surgery only and 3456 (33.8%) treated with surgery plus adjuvant radiation. Surgery followed by adjuvant radiation was associated with significantly improved survival (HR: 0.753, CI: 0.718-0.789, p<0.001). Additionally, female gender and married status were both independently associated with better survival (p<0.05), while advanced age, Caucasian race, higher TNM stage, and higher grade had worse survival outcomes (p<0.05) Asian and Spanish-Hispanic-Latino patients were less likely to receive adjuvant radiotherapy (p<0.05). CONCLUSION: Adjuvant radiation was associated with significantly improved survival after resection for pancreatic cancer. There are significant differences in the patient populations who receive adjuvant radiation.

11.
J Appl Clin Med Phys ; 22(8): 129-138, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34240556

RESUMO

This study used the visualization of hypo-intense regions on liver-specific MRI to directly quantify stereotactic body radiation therapy (SBRT) spatial delivery accuracy. Additionally, the interfractional motion of the liver region was determined and compared with the MRI-based evaluation of liver SBRT spatial treatment delivery accuracy. Primovist® -enhanced MRI scans were acquired from 17 patients, 8-12 weeks following the completion of liver SBRT treatment. Direct visualization of radiation-induced focal liver reaction in the form of hypo-intensity was determined. The auto-delineation approach was used to localize these regions, and center-of-mass (COM) discrepancy was quantified between the MRI hypo-intensity and the CT-based treatment plan. To assess the interfractional motion of the liver region, a planning CT was registered to a Cone Beam CT obtained before each treatment fraction. The interfractional motion assessed from this approach was then compared against the localized hypo-intense MRI regions. The mean ± SD COM discrepancy was 1.4 ± 1.3 mm in the left-right direction, 2.6 ± 1.8 mm in an anteroposterior direction, and 1.9 ± 2.6 mm in the craniocaudal direction. A high correlation was observed between interfractional motion of visualized hypo-intensity and interfractional motion of planning treatment volume (PTV); the quantified Pearson correlation coefficient was 0.96. The lack of correlation was observed between Primovist® MRI-based spatial accuracy and interfractional motion of the liver, where Pearson correlation coefficients ranged from -0.01 to -0.26. The highest random and systematic errors quantified from interfractional motion were in the craniocaudal direction. This work demonstrates a novel framework for the direct evaluation of liver SBRT spatial delivery accuracy.


Assuntos
Radiocirurgia , Tomografia Computadorizada de Feixe Cônico , Humanos , Fígado/diagnóstico por imagem , Movimento (Física) , Planejamento da Radioterapia Assistida por Computador
12.
Rep Pract Oncol Radiother ; 26(6): 883-891, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34992859

RESUMO

BACKGROUND: This analysis evaluates the impacts of biologically effective dose (BED) and histology on local control (LC) of spinal metastases treated with highly conformal radiotherapy to moderately-escalated doses. MATERIALS AND METHODS: Patients were treated at two institutions from 2010-2020. Treatments with less than 5 Gy per fraction or 8 Gy in 1 fraction were excluded. The dataset was divided into three RPA classes predictive of survival (1). The primary endpoint was LC. RESULTS: 223 patients with 248 treatments met inclusion criteria. Patients had a median Karnofsky Performance Status (KPS ) of 80, and common histologies included breast (29.4%), non-small cell lung cancer (15.7%), and prostate (13.3%). A median 24 Gy was delivered in 3 fractions (BED: 38.4 Gy) to a median planning target volume (PTV) of 37.3 cc. 2-year LC was 75.7%, and 2-year OS was 42.1%. Increased BED was predictive of improved LC for primary prostate cancer (HR = 0.85, 95% CI: 0.74-0.99). Patients with favorable survival (RPA class 1) had improved LC with BED ≥ 40 Gy (p = 0.05), unlike the intermediate and poor survival groups. No grade 3-5 toxicities were reported. CONCLUSIONS: Moderately-escalated treatments were efficacious and well-tolerated. BED ≥ 40 Gy may improve LC, particularly for prostate cancer and patients with favorable survival.

13.
Cancer Invest ; 38(10): 599-607, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32715780

RESUMO

The role of stereotactic body radiation therapy (SBRT) in achieving durable local control and palliation of pain in pelvic lymph node oligometastatic disease is not well-studied. We performed a retrospective analysis of 30 patients with 43 pelvic lymph node oligometastases from various primary cancers all but one with non-prostate primaries treated at our institution with SBRT. The median follow-up time was 21 months. The median SBRT dose was 24 Gy in four fractions. The one-, two-, and five-year local control was 74%, 71%, and 70% and one-, two-, and five-year overall survival was 70%, 47%, and 31%. Toxicities were mild with no grade 3 or higher.


Assuntos
Linfonodos/cirurgia , Neoplasias/cirurgia , Neoplasias Pélvicas/cirurgia , Radiocirurgia/mortalidade , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Linfonodos/patologia , Masculino , Pessoa de Meia-Idade , Neoplasias/patologia , Neoplasias Pélvicas/secundário , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida
14.
J Appl Clin Med Phys ; 21(8): 208-215, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32573908

RESUMO

PURPOSE: To assess the accuracy of volumetric modulated arc therapy (VMAT) stereotactic body radiation therapy (SBRT) when treating moving targets (such as lung or liver lesions), focusing on the impact of the interplay effect in the event of complex breathing motion and when a gating window is used. METHODS: A dedicated programmable motion platform was implemented. This platform can carry large quality assurance (QA) phantoms and achieve complex three-dimensional (3D) motion. Volumetric modulated arc therapy SBRT plans were delivered with TrueBeam linac to this moving setup and the measured dose was compared to the computed one. Several parameters were assessed such as breathing period, dose rate, dose prescription, shape of the breathing pattern, the use of a planning target volume (PTV) margin, and the use of a gating window. RESULTS: Loss of dose coverage (D95%) was acceptable in most situations. The doses received by 95% of the CTV, D95% ( C T V m ) ranged from 94 to 101% (mean 98%) and the doses received by 2% of the CTV D2% ( C T V m ) ranged from 94% to 110% of the prescribed dose. A visible interplay effect was observed when no margin was used or when the number of breathing cycles during the treatment delivery was lower than 20. CONCLUSIONS: In our clinical context, treating lung and liver lesions using VMAT SBRT is reasonable. The interplay effect was moderated and acceptable in all simulated situations.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
15.
BMC Cancer ; 19(1): 275, 2019 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-30922261

RESUMO

BACKGROUND: Hepatocellular carcinoma (HCC) accounts for 75-85% of primary liver cancers and is prevalent in the Asia-Pacific region. Till now, trans-arterial chemoembolization (TACE) is still one of common modalities in managing unresectable intermediate-stage HCC. However, post-TACE residual viable HCC is not uncommon, resulting in unsatisfied overall survival after TACE alone. Recently, stereotactic ablative radiotherapy (SABR) has been suggested to manage HCC curatively. However, evidence from phase-III trials is largely lacking. Hence, the present phase III randomized trial is designed to compare clinical outcomes between SABR and re-TACE for unresectable HCC patients who had incomplete response after initial TACE. METHODS: The present study is an open-label, parallel, randomized controlled trial. A total of 120 patients will be included into two study groups, i.e., SABR and re-TACE, with a 1:1 allocation rate. A 3-year allocating period is planned. Patients with incomplete response after initial TACE will be enrolled and randomized. The primary endpoint is 1-year freedom-form-local-progression rate. Secondary endpoints are disease-progression-free survival, overall survival, local control, response rate, toxicity, and duration of response of the treated tumor. DISCUSSION: SABR has been reported as an effective modality in managing intermediate-stage HCC patients, but evidence from phase-III randomized trials is largely lacking. As a result, conducting randomized trials to demarcate the role of SABR in these patients is warranted, especially in the Asia-Pacific region, where HBV- and HCV-related HCCs are prevalent. TRIAL REGISTRATION: Before enrolling participants, the present study was registered prospectively on ClinicalTrials.gov (trial identifier, NCT02921139 ) on Sep. 29, 2016. This study is ongoing.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Neoplasias Hepáticas/terapia , Radiocirurgia/métodos , Quimioembolização Terapêutica/efeitos adversos , Feminino , Humanos , Masculino , Radiocirurgia/efeitos adversos , Análise de Sobrevida , Resultado do Tratamento
16.
J Appl Clin Med Phys ; 20(12): 109-118, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31755658

RESUMO

The purpose of this study was to assess the performance of structure-guided deformable image registration (SG-DIR) relative to rigid registration and DIR using TG-132 recommendations. This assessment was performed for image registration of treatment planning computed tomography (CT) and magnetic resonance imaging (MRI) scans with Primovist® contrast agent acquired post stereotactic body radiation therapy (SBRT). SBRT treatment planning CT scans and posttreatment Primovist® MRI scans were obtained for 14 patients. The liver was delineated on both sets of images and matching anatomical landmarks were chosen by a radiation oncologist. Rigid registration, DIR, and two types of SG-DIR (using liver contours only; and using liver structures along with anatomical landmarks) were performed for each set of scans. TG-132 recommended metrics were estimated which included Dice Similarity Coefficient (DSC), Mean Distance to Agreement (MDA), Target Registration Error (TRE), and Jacobian determinant. Statistical analysis was performed using Wilcoxon Signed Rank test. The median (range) DSC for rigid registration was 0.88 (0.77-0.89), 0.89 (0.81-0.93) for DIR, and 0.90 (0.86-0.94) for both types of SG-DIR tested in this study. The median MDA was 4.8 mm (3.7-6.8 mm) for rigid registration, 3.4 mm (2.4-8.7 mm) for DIR, 3.2 mm (2.0-5.2 mm) for SG-DIR where liver structures were used to guide the registration, and 2.8 mm (2.1-4.2 mm) for the SG-DIR where liver structures and anatomical landmarks were used to guide the registration. The median TRE for rigid registration was 7.2 mm (0.5-23 mm), 6.8 mm (0.7-30.7 mm) for DIR, 6.1 mm (1.1-20.5 mm) for the SG-DIR guided by only the liver structures, and 4.1 mm (0.8-19.7 mm) for SG-DIR guided by liver contours and anatomical landmarks. The SG-DIR shows higher liver conformality as per TG-132 metrics and lowest TRE compared to rigid registration and DIR in Velocity AI software for the purpose of registering treatment planning CT and post-SBRT MRI for the liver region. It was found that TRE decreases when liver contours and corresponding anatomical landmarks guide SG-DIR.


Assuntos
Gadolínio DTPA , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Órgãos em Risco/efeitos da radiação , Intensificação de Imagem Radiográfica/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
17.
Cancer ; 123(18): 3486-3493, 2017 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-28493288

RESUMO

BACKGROUND: As systemic therapy has improved for locally advanced pancreatic cancer (LAPC), efforts to improve local control with optimal radiotherapy may be critical. Although conventionally fractionated radiation therapy (CFRT) has more recently shown a limited role in LAPC, stereotactic body radiation therapy (SBRT) is an emerging approach with promising results. With no studies to date comparing SBRT with CFRT for LAPC, this study used the National Cancer Data Base (NCDB) to evaluate these 2 modalities. METHODS: With the NCDB, patients with American Joint Committee on Cancer cT2-4/N0-1/M0 adenocarcinoma of the pancreas diagnosed from 2004 to 2013 were analyzed. Radiation therapy delivered at ≤2 Gy was deemed CFRT, and radiation therapy delivered at ≥4 Gy per fraction was considered SBRT. Kaplan-Meier analysis, log-rank testing, and multivariate Cox proportional hazards regression were performed with overall survival (OS) as the primary outcome. Propensity score matching was used. RESULTS: Among 8450 patients, 7819 (92.5%) were treated with CFRT, and 631 (7.5%) underwent SBRT. Receipt of SBRT was associated with superior OS in the multivariate analysis (hazard ratio, 0.84; 95% confidence interval, 0.75-0.93; P < .001). With propensity score matching, 988 patients in all were matched, with 494 patients in each cohort. Within the propensity-matched cohorts, the median OS (13.9 vs 11.6 months) and the 2-year OS rate (21.7% vs 16.5%) were significantly higher with SBRT versus CFRT (P = .0014). CONCLUSIONS: In this retrospective review using a large national database, SBRT was associated with superior OS in comparison with CFRT for LAPC, and these findings remained significant in a propensity-matched analysis. Further prospective studies investigating these hypothesis-generating results are warranted. Cancer 2017;123:3486-93. © 2017 American Cancer Society.


Assuntos
Adenocarcinoma/mortalidade , Adenocarcinoma/radioterapia , Fracionamento da Dose de Radiação , Neoplasias Pancreáticas/mortalidade , Neoplasias Pancreáticas/radioterapia , Radiocirurgia/métodos , Adenocarcinoma/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica/patologia , Estadiamento de Neoplasias , Neoplasias Pancreáticas/patologia , Prognóstico , Pontuação de Propensão , Modelos de Riscos Proporcionais , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Análise de Sobrevida , Resultado do Tratamento , Estados Unidos
18.
J Appl Clin Med Phys ; 18(1): 265-268, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28291919

RESUMO

PURPOSE: TrueBeams equipped with the 40 × 30 cm2 Electronic Portal Imaging Devices (EPIDs) are prone to image saturation at the image center when used with flattening filter free (FFF) photon energies. While cine imaging during treatment may not saturate because the beam is attenuated by the patient, the flood field calibration is affected when the standard calibration procedure is followed. Here, we describe the hardware and protocol to achieve improved image quality for this model of TrueBeam EPID. MATERIALS & METHODS: A stainless steel filter of uniform thickness was designed to have sufficient attenuation to avoid panel saturation. The cine imaging flood field calibration was acquired with the filter in place for the FFF energies under the standard calibration geometry (SID = 150 cm). Image quality during MV cine was assessed with & without the modified flood field calibration using a low contrast resolution phantom and an anthropomorphic phantom. RESULTS: When the flood field is acquired without the filter in place, a pixel gain artifact is clearly present in the image center which may be mis-attributed to panel saturation in the subject image. At the image center, the artifact obscured all low contrast inserts and was also visible on the anthropomorphic phantom. Using the filter for flood field calibration eliminates the artifact. CONCLUSION: TrueBeams equipped with the 40 × 30 cm2 IDU can utilize a modified flood field calibration procedure for FFF photon energies that improves image quality for cine MV imaging.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Aceleradores de Partículas/instrumentação , Pelve/diagnóstico por imagem , Imagens de Fantasmas , Radiometria/instrumentação , Calibragem , Humanos , Fótons
19.
J Xray Sci Technol ; 25(3): 465-477, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28157113

RESUMO

BACKGROUND AND PURPOSE: As recent studies have suggested relatively low α/ß for prostate cancer, the interest in hypofractionated stereotactic body radiotherapy (SBRT) for prostate cancer is rising. The aim of this study is to compare dosimetric results of Cyberknife (CK) with Tomotherapy (HT) in SBRT for localized prostate cancer. Furthermore, the radiobiologic consequences of heterogeneous dose distribution are also analyzed. MATERIAL AND METHOD: A total of 12 cases of localized prostate cancer previously treated with SBRT were collected. Treatments had been planned and delivered using CK. Then HT plans were generated for comparison afterwards. The prescribed dose was 37.5Gy in 5 fractions. Dosimetric indices for target volumes and organs at risk (OAR) were compared. For radiobiological evaluation, generalized equivalent uniform dose (gEUD) and normal tissue complication probability (NTCP) were calculated and compared. RESULT: Both CK and HT achieved target coverage while meeting OAR constraints adequately. HT plans resulted in better dose homogeneity (Homogeneity index: 1.04±0.01 vs. 1.21±0.01; p = 0.0022), target coverage (97.74±0.86% vs. 96.56±1.17%; p = 0.0076) and conformity (new vonformity index: 1.16±0.05 vs. 1.21±0.04; p = 0.0096). HT was shown to predict lower late rectal toxicity as compared to CK. Integral dose to body was also significantly lower in HT plans (46.59±6.44 Gy'L vs 57.05±11.68 Gy'L; p = 0.0029). CONCLUSION: Based on physical dosimetry and radiobiologic considerations, HT may have advantages over CK, specifically in rectal sparing which could translate into clinical benefit of decreased late toxicities.


Assuntos
Neoplasias da Próstata/radioterapia , Radiocirurgia , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Masculino
20.
Rep Pract Oncol Radiother ; 22(2): 158-162, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28490987

RESUMO

AIM: The main purpose of this work is to give a technical description and present the properties of the liver SBRT protocol implemented in the Greater Poland Cancer Centre (GPCC) in Poznan, Poland. BACKGROUND: Stereotactic body radiation therapy (SBRT) for liver metastasis is a non-invasive therapeutic option which enables irradiation of a small target in the body with a high dose. MATERIALS AND METHODS: This study presents details of our linac-based liver SBRT protocol. Special emphasis has been placed on fiducial implantation, patient preparation (CT scanning, immobilization), treatment planning, and its implementation. RESULTS: The liver SBRT treatment course implemented in the GPCC consists of three fractions to deliver a total of 45 Gy. Fraction delivery details with description of patient positioning (localization of liver metastasis) are presented below. CONCLUSIONS: The literature validation of the assumptions concerning the steps of the GPCC linac-based liver SBRT procedure show their potential for an effective and patient friendly implementation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA