RESUMO
Hypertrophic scarring is a major source of morbidity. Sex hormones are not classically considered modulators of scarring. However, based on increased frequency of hypertrophic scarring in patients on testosterone, we hypothesized that androgenic steroids induce abnormal scarring and developed a preclinical porcine model to explore these effects. Mini-swine underwent castration, received no testosterone (noT) or biweekly testosterone therapy (+T), and underwent excisional wounding. To create a delayed wound healing model, a subset of wounds were re-excised at 2 weeks. Scars from postoperative day 42 (POD42) and delayed wounds (POD28) were harvested 6 weeks after initial wounding for analysis via histology, bulk RNA-seq, and mechanical testing. Histologic analysis of scars from +T animals showed increased mean fibrosis area (16 mm2noT, 28 mm2+T; p = .007) and thickness (0.246 mm2noT, 0.406 mm2+T; p < .001) compared to noT. XX+T and XY+T scars had greater tensile burst strength (p = .024 and p = .013, respectively) compared to noT swine. Color deconvolution analysis revealed greater deposition of type I and type III collagen as well as increased collagen type I:III ratio in +T scars. Dermatopathologist histology scoring showed that +T exposure was associated with worse overall scarring (p < .05). Gene ontology analysis found that testosterone exposure was associated with upregulation of cellular metabolism and immune response gene sets, while testosterone upregulated pathways related to keratinization and laminin formation on pathway analysis. In conclusion, we developed a preclinical porcine model to study the effects of the sex hormone testosterone on scarring. Testosterone induces increased scar tissue deposition and appears to increase physical strength of scars via supraphysiologic deposition of collagen and other ECM factors. The increased burst strength seen in both XX and XY animals suggests that hormone administration has a strong influence on scar mechanical properties independent of chromosomal sex. Anti-androgen topical therapies may be a promising future area of research.
Assuntos
Cicatriz Hipertrófica , Humanos , Suínos , Animais , Matriz Extracelular , Testosterona/farmacologia , Colágeno Tipo I , LamininaRESUMO
PURPOSE: To understand the effects of consuming high-fat and low-fat dairy products on postprandial cardiometabolic risk factors and intestinal immune function, we used an established low birthweight (LBW) swine model of diet-induced insulin resistance. METHODS: LBW piglets were randomized to consume one of the 3 experimental high fat diets and were fed for a total of 7 weeks: (1) Control high fat (LBW-CHF), (2) CHF diet supplemented with 3 servings of high-fat dairy (LBW-HFDairy) and (3) CHF diet supplemented with 3 servings of low-fat dairy (LBW-LFDairy). As comparison groups, normal birthweight (NBW) piglets were fed a CHF (NBW-CHF) or standard pig grower diet (NBW-Chow). At 11 weeks of age, all piglets underwent an established modified oral glucose and fat tolerance test. At 12 weeks of age, piglets were euthanized and ex vivo cytokine production by cells isolated from mesenteric lymph node (MLN) stimulated with mitogens was assessed. RESULTS: Dairy consumption did not modulate postprandial plasma lipid, inflammatory markers and glucose concentrations. A lower production of IL-2 and TNF-α after pokeweed mitogen (PWM) stimulation was observed in LBW-CHF vs NBW-Chow (P < 0.05), suggesting impaired MLN T cell function. While feeding high-fat dairy had minimal effects, feeding low-fat dairy significantly improved the production of IL-2 and TNF-α after PWM stimulation (P < 0.05). CONCLUSIONS: Irrespective of fat content, dairy had a neutral effect on postprandial cardiometabolic risk factors. Low-fat dairy products improved intestinal T cell function to a greater extent than high-fat dairy in this swine model of obesity and insulin resistance.
Assuntos
Resistência à Insulina , Animais , Peso ao Nascer , Dieta com Restrição de Gorduras , Glucose , Imunidade , Resistência à Insulina/fisiologia , Interleucina-2 , Suínos , Fator de Necrose Tumoral alfaRESUMO
PURPOSE: SAM junctional tourniquet (SJT) has been applied to control junctional hemorrhage. However, there is limited information about its safety and efficacy when applied in the axilla. This study aims to investigate the effect of SJT on respiration when used in the axilla in a swine model. METHODS: Eighteen male Yorkshire swines, aged 6-month-old and weighing 55 - 72 kg, were randomized into 3 groups, with 6 in each. An axillary hemorrhage model was established by cutting a 2 mm transverse incision in the axillary artery. Hemorrhagic shock was induced by exsanguinating through the left carotid artery to achieve a controlled volume reduction of 30% of total blood volume. Vascular blocking bands were used to temporarily control axillary hemorrhage before SJT was applied. In Group I, the swine spontaneously breathed, while SJT was applied for 2 h with a pressure of 210 mmHg. In Group II, the swine were mechanically ventilated, and SJT was applied for the same duration and pressure as Group I. In Group III, the swine spontaneously breathed, but the axillary hemorrhage was controlled using vascular blocking bands without SJT compression. The amount of free blood loss was calculated in the axillary wound during the 2 h of hemostasis by SJT application or vascular blocking bands. After then, a temporary vascular shunt was performed in the 3 groups to achieve resuscitation. Pathophysiologic state of each swine was monitored for 1 h with an infusion of 400 mL of autologous whole blood and 500 mL of lactated ringer solution. Tb and T0 represent the time points before and immediate after the 30% volume-controlled hemorrhagic shock, respectively. T30, T60, T90 and T120, denote 30, 60, 90, and 120 min after T0 (hemostasis period), while T150, and T180 denote 150 and 180 min after T0 (resuscitation period). The mean arterial pressure and heart rate were monitored through the right carotid artery catheter. Blood samples were collected at each time point for the analysis of blood gas, complete cell count, serum chemistry, standard coagulation tests, etc., and thromboelastography was conducted subsequently. Movement of the left hemidiaphragm was measured by ultrasonography at Tb and T0 to assess respiration. Data were presented as mean ± standard deviation and analyzed using repeated measures of two-way analysis of variance with pairwise comparisons adjusted using the Bonferroni method. All statistical analyses were processed using GraphPad Prism software. RESULTS: Compared to Tb, a statistically significant increase in the left hemidiaphragm movement at T0 was observed in Groups I and II (both p < 0.001). In Group III, the left hemidiaphragm movement remained unchanged (p = 0.660). Compared to Group I, mechanical ventilation in Group II significantly alleviated the effect of SJT application on the left hemidiaphragm movement (p < 0.001). Blood pressure and heart rate rapidly increased at T0 in all three groups. Respiratory arrest suddenly occurred in Group I after T120, which required immediate manual respiratory assistance. PaO2 in Group I decreased significantly at T120, accompanied by an increase in PaCO2 (both p < 0.001 vs. Groups II and III). Other biochemical metabolic changes were similar among groups. However, in all 3 groups, lactate and potassium increased immediately after 1 min of resuscitation concurrent with a drop in pH. The swine in Group I exhibited the most severe hyperkalemia and metabolic acidosis. The coagulation function test did not show statistically significant differences among three groups at any time point. However, D-dimer levels showed a more than 16-fold increase from T120 to T180 in all groups. CONCLUSION: In the swine model, SJT is effective in controlling axillary hemorrhage during both spontaneous breathing and mechanical ventilation. Mechanical ventilation is found to alleviate the restrictive effect of SJT on thoracic movement without affecting hemostatic efficiency. Therefore, mechanical ventilation could be necessary before SJT removal.
Assuntos
Choque Hemorrágico , Doenças Vasculares , Masculino , Animais , Suínos , Choque Hemorrágico/terapia , Torniquetes , Axila , Hemorragia/terapia , RespiraçãoRESUMO
BACKGROUND: To improve the laparoscopic surgical dissection, the aim of the study was to assess the safety of burst of high-pressure CO2 using a 5-mm laparoscopic pneumodissector (PD) operating at different flow rates and for different operating times regarding the risk of gas embolism (GE) in a swine model. METHODS: The first step was to define the settings use of the PD device ensuring no GE. Successive procedures were conducted by laparotomy: cholecystectomy, the PD was placed 10 mm deep in the liver and the PD was directly introduced into the lumen of the inferior vena cava. Different PD flow rates of 5, 10, and 15 mL/s were used. The second step was to assess the safety of the device (PD group) during a laparoscopic dissection task (cystic and hepatic pedicles dissection, cholecystectomy and right nephrectomy) in comparison with the use of a standard laparoscopic hook device (control group). PD flow rate was 10 mL/s and consecutive burst of high-pressure CO2 was delivered for 3-5 s. RESULTS: In the first step (n = 17 swine), no GE occurred during cholecystectomy regardless of the PD flow rate used. When the PD was placed in the liver or into the inferior vena cava, no severe or fatal GE occurred when a burst of high-pressure CO2 was applied for 3 or 5 s with PD flow rates of 5 and 10 mL/s. In the second step (PD group, n = 10; control group, n = 10), no GE occurred in the PD group. The use of the PD did not increase operative time or blood loss. The quality of the dissection was significantly improved compared to the control group. CONCLUSIONS: The 5-mm laparoscopic PD appears to be free from CO2 GE risk when consecutive bursts of high-pressure CO2 are delivered for 3-5 s with a flow rate of 10 mL/s.
Assuntos
Colecistectomia Laparoscópica , Embolia Aérea , Laparoscopia , Animais , Dióxido de Carbono , Colecistectomia Laparoscópica/métodos , Dissecação/métodos , Embolia Aérea/etiologia , Embolia Aérea/prevenção & controle , Humanos , Laparoscopia/métodos , Nefrectomia/métodos , Suínos , Veia Cava Inferior/cirurgiaRESUMO
INTRODUCTION: Image-guided non-invasive high-intensity focused ultrasound (HIFU) has been gaining recognition in treating musculoskeletal tumors and desmoids. However, there is no consensus on the appropriate perioperative management for patients on ongoing anticoagulation who undergo HIFU ablation. MATERIAL AND METHODS: Image-guided HIFU treatment was performed in swine on an ongoing oral anticoagulation protocol (N = 5) in two treatment sessions seven days apart. On day one, a total of twenty locations were ablated, and on day eight, ten more muscle ablations were performed, and the animals were euthanized. Imaging, clinical examination, and histopathology were performed to investigate treated tissue for bleeding. RESULTS: Imaging, clinical examination, and histopathology revealed either no bleeding or, in some samples, only small scattered cavities (0.2-2 mm in diameter) filled with blood. CONCLUSION: Noninvasive HIFU ablation of muscle may not require a coagulation profile within normal limits.
Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Animais , Humanos , Músculos , SuínosRESUMO
Fractional myocardial blood volume (fMBV) estimated using ferumoxytol-enhanced magnetic resonance imaging (MRI) (FE-MRI) has the potential to capture a hemodynamic response to myocardial hypoperfusion during contrast steady state without reliance on gadolinium chelates. Ferumoxytol has a long intravascular half-life and its use for steady-state MRI is off-label. The aim of this prospective study was to optimize and evaluate a two-compartment model for estimation of fMBV based on FE-MRI. Nine healthy swine and one swine with artificially induced single-vessel coronary stenosis underwent MRI on a 3.0 T clinical magnet. Myocardial longitudinal spin-lattice relaxation rate (R1) was measured using the 5(3)3(3)3 modified Look-Locker inversion recovery (MOLLI) sequence before and at contrast steady state following seven ferumoxytol infusions (0.125-4.0 mg/kg). fMBV and water exchange were estimated using a two-compartment model. Model-fitted fMBV was compared to simple fast-exchange fMBV approximation and percent change in pre- and postferumoxytol R1. Dose undersampling schemes were investigated to reduce acquisition duration. Variation in fMBV was assessed using one-way analysis of variance. Fast-exchange fMBV and ferumoxytol dose undersampling were evaluated using Bland-Altman analysis. Healthy normal swine showed a mean mid-ventricular fMBV of 7.2 ± 1.4% and water exchange rate of 11.3 ± 5.1 s-1 . There was intersubject variation in fMBV (p < 0.05) without segmental variation (p = 0.387). fMBV derived from eight-dose and four-dose sampling schemes had no significant bias (mean difference = 0.07, p = 0.541, limits of agreement -1.04% [-1.45, -0.62%] to 1.18% [0.77, 1.59%]). Pixel-wise fMBV in one swine model with coronary artery stenosis showed elevated fMBV in ischemic segments (apical anterior: 11.90 ± 4.00%, apical septum: 16.10 ± 5.71%) relative to remote segments (apical inferior: 9.59 ± 3.35%, apical lateral: 9.38 ± 2.35%). A two-compartment model based on FE-MRI using the MOLLI sequence may enable estimation of fMBV in studies of ischemic heart disease. LEVEL OF EVIDENCE: 2. TECHNICAL EFFICACY STAGE: 2.
Assuntos
Óxido Ferroso-Férrico , Água , Animais , Volume Sanguíneo , Meios de Contraste , Imageamento por Ressonância Magnética , Estudos Prospectivos , Reprodutibilidade dos Testes , SuínosRESUMO
BACKGROUND: This work sought to (1) establish a reliable gunshot model of junctional femoral artery rupture in swine that accurately simulates field rescue conditions and (2) use the gunshot model to compare the efficacy and ease of application of zeolite nanometer hemostatic gauze with other hemostatic materials. METHODS: Thirty-six healthy landrace swine (body weight 50 ± 5 kg) were randomly divided into three groups which were treated with Combat Gauze (CG), FeiChuang hemostatic gauze (FG), or standard medical gauze (SG). A gunshot model of femoral artery hemorrhage in landrace swine was used with portable ultrasound to accurately position the wound. After the shooting, when mean arterial pressure of swine decreased by at least 30% for 10 s, wounds were pressed with standard packing (39 g) of gauze materials for 3 min to stop bleeding, then bandaged with pressure. Blood samples were taken 15 min before injury, then 10 min, 30 min, and 60 min after injury to determine hemodynamic, coagulation, and arterial blood gas indexes. Wound temperatures were taken at 5 min, 10 min, 30 min, and 60 min after injury, and survival times were recorded. The volume of blood loss and survival time were used to evaluate hemostatic effect, whereas the fill time, wound temperature, and physiological indexes were used to evaluate the safety and operation of the product. RESULTS: The CG (11.15 ± 3.09 mL/kg) and FG (12.19 ± 3.5 mL/kg) groups had significantly less blood loss than the SG group (16.8 ± 5.14 mL/kg) (P = 0.04; P = 0.039, respectively). After gauze packing, bleeding in CG (5.85 ± 1.17 mL/kg) and FG (5.37 ± 0.93 mL/kg) groups remained significantly lower than that of the SG group (6.93 ± 1.03 mL/kg) (P = 0.011; P = 0.003, respectively). Wound temperature rose with time for all groups (P < 0.001). The wound temperatures in the FG group and the CG group were significantly higher than that of the SG group (P = 004 and 0.009, respectively). Survival rates and times were not significantly different among the three groups, although the FG group had the longest average survival time (standard deviation [SD] 204.8 s), compared with the SG group (SD 177.8 s) and CG (SD 187.5 s) groups. No significant differences in hemodynamics, blood gas, and coagulation were observed among the three groups. CONCLUSIONS: The gunshot model of junctional femoral arterial hemorrhage guided by ultrasound had high accuracy for femoral arterial rupture by bullet wound and provided consistent and reproducible field-simulation conditions for comparison of hemostatic materials. FeiChuang zeolite hemostatic gauze effectively controlled bleeding as well as combat gauze, without excessive heat as found in other zeolite-based products. However, improvements to application technique, such as a packing device, are needed to improve operating time.
Assuntos
Hemorragia/terapia , Técnicas Hemostáticas , Hemostáticos/administração & dosagem , Ferimentos por Arma de Fogo/terapia , Zeolitas/administração & dosagem , Animais , Modelos Animais de Doenças , Artéria Femoral/lesões , Hemorragia/etiologia , Humanos , Sus scrofa , Ferimentos por Arma de Fogo/complicaçõesRESUMO
PURPOSE: Microwave ablation (MWA) provides an effective treatment of lung and liver tumors but suffers from a lack of reproducibility of ablation size among currently available technologies. In-vitro evaluations are far removed from clinical practices because of uninfused tissue. This study is in-vivo preclinical testing of a new MWA system on swine lungs and liver. MATERIALS AND METHODS: All ablations were performed under CT guidance and multiple algorithms were tested with a power of 50, 75, and 100 W for durations of 3, 5, 8, 10, and 15 min. A 3 D-evaluation of the ablation zone was carried out using enhanced-CT. The sphericity index, coefficients of variation, and energy efficiency (which corresponds to the volume yield according to the power supplied) were calculated. RESULTS: Fifty liver and 48 lung ablations were performed in 17 swine. The sphericity index varies from 0.50 to 0.80 for liver ablations and from 0.40 to 0.69 for lung ablations. The coefficient of variation was below 15% for 4/5 and 4/8 protocols for lung and liver ablations, respectively. The energy efficiency seems to decrease with the duration of the ablation from 0.60 × 10-3 cm3/J (75 W, 3 min) to 0.26 × 10-3 cm3/J (100 W, 15 min) in the liver and from 0.57 × 10-3 cm3/J (50 W, 10 min) to 0.42 × 10-3 cm3/J (100 W, 12 min) in the lungs. CONCLUSION: A shorter treatment time provides the best energy efficiency, and the best reproducibility is obtained for a 10 min treatment duration. The system tested provides an interesting reproducibility in both lung and liver measurements. Our results may help interventional radiologists in the optimal selection of treatment parameters.
Assuntos
Técnicas de Ablação , Ablação por Cateter , Animais , Humanos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Micro-Ondas , Reprodutibilidade dos Testes , Suínos , Tomografia Computadorizada por Raios XRESUMO
PURPOSE: The purpose of this study was to develop a simple and effective percutaneous approach to create tricuspid regurgitation in swine. METHODS: Eleven pigs (71.68 ± 7.70 kg, 3 male) were involved in this study. A grasping forceps was introduced into the right ventricle through a steerable sheath under fluoroscopic guidance and used to disrupt the tricuspid valve apparatus by avulsing leaflet or chordae tendineae repeatedly. Transthoracic echocardiography and right ventricular angiography were used to evaluate the degree of tricuspid regurgitation created. RESULTS: Ten of the 11 pigs (90.91%) achieved severe tricuspid regurgitation and 1 (9.09%) obtained moderate tricuspid regurgitation immediately after the procedure. Heart rate of the pigs significantly increased immediately after tricuspid regurgitation creation compared to baseline (88.64 ± 23.24 vs. 76.00 ± 15.30 bpm, P = 0.02), but recovered to normal level at one month follow-up (77.09 ± 11.97 bpm, P = 0.85). The right atrium, tricuspid valve annulus, and right ventricle dilated obviously one month after tricuspid regurgitation creation (dimension changes: 3.01 ± 0.35 vs. 3.56 ± 0.40 cm, P = 0.02; 2.92 ± 0.36 vs. 3.37 ± 0.39 cm, P = 0.01; 3.06 ± 0.42 vs. 3.60 ± 0.47 cm, P = 0.03 respectively). Autopsy findings showed that rupture of leaflet and/or chordae tendineae finally led to the tricuspid regurgitation. CONCLUSIONS: Severe tricuspid regurgitation can be created by a simple and effective percutaneous approach with a grasping forceps in swine model and right heart dilation can be observed consistently at one-month follow-up. This model will be valuable in pre-clinical studies for developing new tricuspid valve repair or replacement technique to treat severe tricuspid regurgitation.
Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Modelos Animais de Doenças , Suínos , Insuficiência da Valva Tricúspide/patologia , Animais , Cordas Tendinosas/diagnóstico por imagem , Cordas Tendinosas/patologia , Cordas Tendinosas/fisiopatologia , Ecocardiografia , Procedimentos Endovasculares/métodos , Frequência Cardíaca/fisiologia , Humanos , Masculino , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/patologia , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/fisiopatologiaRESUMO
BACKGROUND: The mechanical stimulus (i.e. stress or stretch) for growth occurring in the pressure-overloaded left ventricle (LV) is not exactly known. OBJECTIVE: To address this issue, we investigate the correlation between local ventricular growth (indexed by local wall thickness) and the local acute changes in mechanical stimuli after aortic banding. METHODS: LV geometric data were extracted from 3D echo measurements at baseline and 2 weeks in the aortic banding swine model (n = 4). We developed and calibrated animal-specific finite element (FE) model of LV mechanics against pressure and volume waveforms measured at baseline. After the simulation of the acute effects of pressure-overload, the local changes of maximum, mean and minimum myocardial stretches and stresses in three orthogonal material directions (i.e., fiber, sheet and sheet-normal) over a cardiac cycle were quantified. Correlation between mechanical quantities and the corresponding measured local changes in wall thickness was quantified using the Pearson correlation number (PCN) and Spearman rank correlation number (SCN). RESULTS: At 2 weeks after banding, the average septum thickness decreased from 10.6 ± 2.92mm to 9.49 ± 2.02mm, whereas the LV free-wall thickness increased from 8.69 ± 1.64mm to 9.4 ± 1.22mm. The FE results show strong correlation of growth with the changes in maximum fiber stress (PCN = 0.5471, SCN = 0.5111) and changes in the mean sheet-normal stress (PCN= 0.5266, SCN = 0.5256). Myocardial stretches, however, do not have good correlation with growth. CONCLUSION: These results suggest that fiber stress is the mechanical stimuli for LV growth in pressure-overload.
RESUMO
Objective: To explore various microwave (MW) time/power combinations to achieve maximum single-probe system performance in a live pig liver model.Methods: Fifty-one microwave ablations performed in 12 female pigs using the following time/power combinations: 65 W for 10 min (65W 10MIN), ramped from 20 to 65 W (RAMPED), 95 W pulses with cooling periods (95W PULSED), 40 W for 16 min 15 s (LOW POWER), 1 min 95 W pulse then 8 min 65 W then a second 1 min 95 W pulse (BOOKEND 95W) and 65 W for 15 min (65W 15MIN). Temperatures 1.5 cm from the antenna were measured. Livers were excised, and ablations were measured and compared.Results: At fixed overall energy, LOW POWER produced ablation zones with the smallest volume compared to 65W 10MIN, RAMPED and 95W PULSED. At a fixed time of 10-min, BOOKEND 95W protocol achieved wider and larger ablation zones than 65W 10MIN (p = 0.038, p = 0.008) and 95W PULSED (p = 0.049, p = 0.004). The 65W 15MIN combination had significantly larger diameters (p = 0.026), larger lengths (p = 0.014) and larger volumes (p = 0.005) versus 65W 10MIN. Maximum temperatures were highest with BOOKEND 95W (62.9 °C) and 65 W 15 MIN (63.0 °C) and lowest with LOW POWER (45.9 °C), p = 0.009.Conclusions: Low power ablations, even if controlled for total energy delivery, create small ablation zones. High peak powers are associated with larger ablation zones and high margin temperatures if cooling pauses are avoided. Ramping and pulsing protocols with interleaved cooling appear to be of no benefit versus continuous 65 W for creating large ablation zones.
Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Animais , Temperatura Baixa , Feminino , Fígado/cirurgia , Micro-Ondas , SuínosRESUMO
Optical mapping is recognized as a promising tool for the registration of electrical activity in the heart. Most cardiac optical mapping experiments are performed in ex vivo isolated heart models. However, the electrophysiological properties of the heart are highly influenced by the autonomic nervous system as well as humoral regulation; therefore, in vivo investigations of heart activity in large animals are definitely preferred. Furthermore, such investigations can be considered the last step before clinical application. Recently, two comprehensive studies have examined optical mapping approaches for pig hearts in situ (in vivo), likely advancing the methodological capacity to perform complex electrophysiological investigations of the heart. Both studies had the same aim, i.e., to develop high-spatiotemporal-resolution optical mapping suitable for registration of electrical activity of pig heart in situ, but the methods chosen were different. In this brief review, we analyse and compare the results of recent studies and discuss their translational potential for in situ cardiac optical mapping applications in large animals. We focus on the modes of blood circulation that are employed, the use of different voltage-sensitive dyes and their loading procedures, and ways of eliminating contraction artefacts. Finally, we evaluate the possible scenarios for optical mapping (OM) application in large animals in situ and infer which scenario is optimal.
Assuntos
Coração , Animais , Coração/diagnóstico por imagem , SuínosRESUMO
OBJECTIVE: Haemodynamic and geometric factors play pivotal roles in the propagation of acute type B aortic dissection (TBAD). The aim of this study was to evaluate the association between dissection level within all aortic layers and the propagation of acute TBAD in porcine aorta. METHODS: In twelve pigs, two models of TBAD were created. In model A (n = 6), the aortic wall tear was superficial and close to the intima (thin intimal flap), whereas in model B (n = 6) it was deep and close to the adventitia (thick intimal flap). Dissection propagation was evaluated using angiography or computed tomography scans, and the haemodynamic measurements were acquired using Doppler wires. Most pigs were followed up at 1, 3, 6, 12, 18, and up to 24 months; four animals were euthanised at three and six months, respectively (two from each group). RESULTS: Both models were successfully created. No statistical difference was observed for the median antegrade propagation distance intra-operatively between the two models (p = .092). At 24 months, the longitudinal propagation distance was significantly greater in model B than in model A (p = .016). No statistical difference in retrograde propagation was noted (p = .691). Over time, aortic wall dissection progressed most notably over the first three months in model A, whereas it continued over the first 12 months in model B. Flow velocity was significantly greater in the true lumen than in false lumen at the level of the primary tear (p = .001) and in the middle of the dissection (p = .004). The histopathological images at three and six months demonstrated the fibres were stretched linearly at the outside wall of false lumen in both models, while the depth of intimal tears developed to be superficial and similar at the distal dissection. CONCLUSION: In this swine model of TBAD, a deeper intimal tear resulted in greater dissection propagation.
Assuntos
Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico , Dissecção Aórtica/diagnóstico , Velocidade do Fluxo Sanguíneo/fisiologia , Doença Aguda , Dissecção Aórtica/fisiopatologia , Animais , Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/fisiopatologia , Angiografia por Tomografia Computadorizada/métodos , Modelos Animais de Doenças , Progressão da Doença , Feminino , Masculino , Prognóstico , Índice de Gravidade de Doença , Suínos , Ultrassonografia Doppler/métodosRESUMO
The use of polyphenols is a promising strategy for preventing or alleviating intrauterine growth restriction (IUGR) because polyphenol supplementation increases plasma antioxidant capacity and improves oxidative stress at the feto-placental unit; which are recognized as main issues in IUGR. However, there is a scarcity of experimental data on both realistic benefits and potential hazards of polyphenol supplementation during gestation. Hence, we aimed to use a swine model of IUGR pregnancy to determine possible effects of maternal supplementation with polyphenols (hydroxytyrosol) on placental expression of genes involved in antioxidant homeostasis, vascularization and fetal growth and thus on antioxidant status, DNA-methylation and phenotypic traits (morphology and homeostasis) of the fetus. Hydroxytyrosol improves placental gene expression and fetal antioxidant status and glucose metabolism in a sex-dependent manner, in which males were favored in spite of developmental failures. Concomitantly, hydroxytyrosol prevented hypomethylation of DNA associated with oxidative stress. Finally, no major deleterious effects of hydroxytyrosol supplementation on constriction of the ductus arteriosus, a possible secondary effect of polyphenols during pregnancy, were found.
Assuntos
Antioxidantes/uso terapêutico , Metilação de DNA/efeitos dos fármacos , Retardo do Crescimento Fetal/tratamento farmacológico , Expressão Gênica/efeitos dos fármacos , Álcool Feniletílico/análogos & derivados , Placenta/efeitos dos fármacos , Polifenóis/uso terapêutico , Animais , Feminino , Retardo do Crescimento Fetal/genética , Retardo do Crescimento Fetal/metabolismo , Feto/efeitos dos fármacos , Feto/metabolismo , Masculino , Estresse Oxidativo/efeitos dos fármacos , Fenótipo , Álcool Feniletílico/uso terapêutico , Placenta/metabolismo , Gravidez , SuínosRESUMO
OBJECTIVE: The purpose of our study was to investigate the effect of adipose-derived stem cells (ASCs), endothelial-differentiated ASCs (EC/ASCs), and various conditioned media (CM) on wound healing in a diabetic swine model. We hypothesized that ASC-based therapies would accelerate wound healing. METHODS: Diabetes was induced in four Yorkshire swine through intravenous injection of streptozotocin. ASCs were harvested from flank fat and cultured in either M199 or EGM-2 medium. A duplicate series of seven full-thickness dorsal wounds were surgically created on each swine. The wounds in the cellular treatment group underwent injection of low-dose or high-dose ASCs or EC/ASCs on day 0, with a repeat injection of one half of the initial dose on day 15. Wounds assigned to the topical CM therapy were covered with 2 mL of either serum-free M199 primed by ASCs or human umbilical vein endothelial cells every 3 days. Wounds were assessed at day 0, 10, 15, 20, and 28. The swine were sacrificed on day 28. ImageJ software was used to evaluate the percentage of wound healing. The wounded skin underwent histologic, reverse transcription polymerase chain reaction, and enzyme-linked immunosorbent assay examinations to evaluate markers of angiogenesis and inflammation. RESULTS: We found an increase in the percentage of wound closure rates in cell-based treatments and topical therapies at various points compared with the untreated control wounds (P < .05). The results from the histologic, messenger RNA, and protein analyses suggested the treated wounds displayed increased angiogenesis and a diminished inflammatory response. CONCLUSIONS: Cellular therapy with ASCs, EC/ASCs, and topical CM accelerated diabetic wound healing in the swine model. Enhanced angiogenesis and immunomodulation might be key contributors to this process.
Assuntos
Tecido Adiposo/citologia , Diferenciação Celular , Meios de Cultivo Condicionados/farmacologia , Diabetes Mellitus Experimental/complicações , Células Progenitoras Endoteliais/transplante , Células-Tronco Multipotentes/transplante , Pele/irrigação sanguínea , Cicatrização , Ferimentos Penetrantes/terapia , Administração Tópica , Animais , Diferenciação Celular/efeitos dos fármacos , Células Cultivadas , Meios de Cultivo Condicionados/metabolismo , Diabetes Mellitus Experimental/metabolismo , Diabetes Mellitus Experimental/patologia , Células Progenitoras Endoteliais/metabolismo , Regulação da Expressão Gênica , Células Endoteliais da Veia Umbilical Humana/metabolismo , Humanos , Masculino , Células-Tronco Multipotentes/metabolismo , Neovascularização Fisiológica , Fenótipo , Pele/efeitos dos fármacos , Pele/lesões , Pele/metabolismo , Sus scrofa , Fatores de Tempo , Cicatrização/efeitos dos fármacos , Ferimentos Penetrantes/etiologia , Ferimentos Penetrantes/metabolismo , Ferimentos Penetrantes/patologiaRESUMO
The objective of this study was to compare the effects of nonpulsatile and ECG-synchronized pulsatile extracorporeal life support on coronary and carotid blood flow velocities using transthoracic echocardiography and vascular ultrasound, respectively. Nine adult swine were randomly separated into nonpulsatile (NP, n = 5) and pulsatile (P, N = 4) groups and placed on ECLS for 24 h using an i-cor ECLS system. Noninvasive transthoracic images of the left and right coronary artery and the left carotid artery were acquired at the pre-ECLS (baseline), 30 min, 3, 6, 9, 12, and 24 h on-ECLS stages. The mean diastolic velocity of the left and right coronary arteries in the NP group significantly decreased after 24 h on ECLS compared to the baseline and 30 min ECLS stages (P < 0.05). There was no statistical difference in the mean diastolic velocity of the coronary arteries in the P group at 30 min, 3-, 6-, 9-, 12-, and 24-h ECLS compared to baseline. The P group showed a smaller decrease in the mean diastolic velocity of coronary arteries between the 30-min ECLS and 3-, 6-, 9-, 13-, 24-h ECLS stages compared to the NP group. The diastolic velocity of the left carotid artery in the NP group significantly decreased during 24-h ECLS compared to the P group (P < 0.05). An ECG-synchronized pulsatile ECLS system appeared to maintain coronary and carotid artery diastolic velocities better than conventional nonpulsatile ECLS. Further investigation of the perfusion modes during ECLS is warranted.
Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Artérias Carótidas/fisiologia , Vasos Coronários/fisiologia , Oxigenação por Membrana Extracorpórea/métodos , Fluxo Sanguíneo Regional/fisiologia , Animais , Hemodinâmica/fisiologia , Modelos Animais , Fluxo Pulsátil/fisiologia , Suínos , Resistência Vascular/fisiologiaRESUMO
Cyanides are highly toxic compounds that have been used as weapons of terrorism throughout history. Cyanide (CN) is acutely toxic by all routes of administration; however, inhalation is the main exposure route. To adequately test effective countermeasures against inhalational CN threats, robust and well-characterized animal models are needed. This paper describes the initial development of a hydrogen cyanide (HCN) exposure swine model for documenting the physiological effects and toxicological profile during and after HCN inhalation exposure. Animals were implanted with telemetry transmitters for heart rate (HR), blood pressure, and electrocardiogram monitoring, and vascular access ports for serial blood collections. Nine female swine were exposed to HCN concentrations of 500 ± 6 ppm while breathing parameters were monitored real-time. Inhaled HCN doses ranged from 2.02 to 2.83 mg/kg. Clinical signs included vocalization, agitation, salivation, respiratory distress and apnea. After HCN exposure initiation, systemic arterial pressure fell dramatically with a concomitant increase in HR. Blood samples were collected to determine CN blood levels using LC-MS/MS and blood gas analysis. In summary, the developed HCN inhalation swine model permitted documentation of the physiological effects associated with CN poisoning. This model could be used to evaluate potential CN medical countermeasures in the event of a public health emergency stemming from inhalational CN threats.
Assuntos
Modelos Animais de Doenças , Cianeto de Hidrogênio/administração & dosagem , Cianeto de Hidrogênio/intoxicação , Administração por Inalação , Animais , Pressão Sanguínea/efeitos dos fármacos , Eletrocardiografia , Feminino , Frequência Cardíaca/efeitos dos fármacos , Cianeto de Hidrogênio/sangue , Suínos , TelemetriaRESUMO
There is no simple method to measure glomerular filtration rate (GFR) in swine, an established model for studying renal disease. We developed a protocol to measure GFR in conscious swine by using the plasma clearance of iohexol. We used two groups, test and validation, with eight animals each. Ten milliliters of iohexol (6.47 g) was injected into the marginal auricular vein and blood samples (3 mL) were collected from the orbital sinus at different points after injection. GFR was determined using two models: two-compartment (CL2: all samples) and one-compartment (CL1: the last six samples). In the test group, CL1 overestimated CL2 by ~30%: CL2 = 245 ± 93 and CL1 = 308 ± 123 mL/min. This error was corrected by a first-order polynomial quadratic equation to CL1, which was considered the simplified method: SM = -47.909 + (1.176xCL1) - (0.00063968xCL1²). The SM showed narrow limits of agreement with CL2, a concordance correlation of 0.97, and a total deviation index of 14.73%. Similar results were obtained for the validation group. This protocol is reliable, reproducible, can be performed in conscious animals, uses a single dose of the marker, and requires a reduced number of samples, and avoids urine collection. Finally, it presents a significant improvement in animal welfare conditions and handling necessities in experimental trials.
Assuntos
Iohexol/análise , Testes de Função Renal/métodos , Plasma/metabolismo , Animais , Calibragem , Iohexol/farmacocinética , Testes de Função Renal/normas , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , SuínosRESUMO
BACKGROUND: The adverse effects of myocardial ischemia and reperfusion during cardiopulmonary bypass (CPB) have been thoroughly described. Lazaroid U-74389G, a 21 aminosteroid, has been shown to attenuate ischemia and reperfusion injury and improve recovery in a variety of experimental models. METHODS: Sixteen male swine were randomly divided in two groups. All animals underwent 45 min of ischemic cardioplegic arrest, with U-74389G addition to the standard cardioplegic solution, whereas controls underwent the same procedure without U-74389G. Creatine kinase-MB isoenzyme (CK-MB) and cardiac troponin T levels were measured immediately before CPB (time point 0), during the ischemic period (time point 1) and 30 (time point 2), 60 (time point 3), and 120 (time point 4) min after reperfusion. Myocardial biopsies were obtained at time points 0 and 4. RESULTS: CK-MB levels (in U/L) at time points 0-4 were 205 (186-235) versus 219 (196-269; P = 0.72), 215 (167-248) versus 253 (193-339; P = 0.23), 234 (198-255) versus 338 (249-441; P = 0.02), 244 (217-272) versus 354 (269-496; P = 0.01), and 285 (230-321) versus 439 (432-530; P < 0.01) in lazaroid-treated animals versus controls, respectively. Cardiac troponin T levels (in ng/L) at time points 0-4 were 58 (26-287) versus 237 (26-395; P = 0.72), 129 (61-405) versus 265 (145-525; P = 0.23), 261 (123-467) versus 474 (427-1604; P = 0.04), 417 (204-750) versus 841 (584-1818; P = 0.11), and 643 (353-1259) versus 1600 (1378-2313; P < 0.01), respectively. Necrosis grades at time point 4 were 0.0 (0.0-1.0) versus 1.5 (1.0-2.0; P < 0.01) in lazaroid-treated animals versus controls, respectively. CONCLUSIONS: The present study, in addition to reconfirming the well-described adverse effects of CPB, demonstrates the efficacy of the newer generation lazaroid U-74389G in alleviating these effects.
Assuntos
Cardiotônicos/uso terapêutico , Traumatismo por Reperfusão Miocárdica/tratamento farmacológico , Pregnatrienos/uso terapêutico , Animais , Biomarcadores/metabolismo , Biópsia , Masculino , Traumatismo por Reperfusão Miocárdica/metabolismo , Traumatismo por Reperfusão Miocárdica/patologia , Miocárdio/metabolismo , Miocárdio/patologia , Necrose , Distribuição Aleatória , Suínos , Resultado do TratamentoRESUMO
BACKGROUND: The pig is commonly used as a preclinical model for ventral hernia repair. However, no study has verified that an unrepaired surgically induced hernia (control) in the pig does not heal spontaneously but rather develops a persistent hernia. Without such verification in any given model, one cannot draw conclusions on the efficacy of the repair technique investigated. MATERIALS AND METHODS: Three surgically induced hernia models with increasing severity were created in eight pigs. These included 10-cm retrorectus partial-thickness (model 1) and 15-cm preperitoneal full-thickness (model 2) incisional defects and an 8 × 8 cm preperitoneal full-thickness excisional defect (model 3). Postoperative management included use of an abdominal binder, and in some cases, suction drainage, for 2 wk to support the repair and prevent seroma. Models were evaluated for persistence of hernia at 5 wk using clinical and radiographic assessments. RESULTS: All pigs developed clinical hernias after 2 wk of defect creation, but only models 1 and 3 had clinically persistent hernias at 5 wk. At 5 wk, the average defect area was 97 cm2 in model 1, 66 cm2 in model 2, and 245 cm2 in model 3. Dense fibrotic scarring was observed in the models with resolved hernias. CONCLUSIONS: Our results highlight the need to verify an unrepaired hernia injury model does not heal spontaneously prior to using it for hernia repair studies. The partial-thickness incisional model 1 and full-thickness excisional model 3 formed persistent hernias in pigs at 5 wk and should be further explored as models for investigating hernia repair strategies.