Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
2.
J Diabetes Sci Technol ; : 19322968241229074, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38323362

RESUMO

BACKGROUND: Optimization of automated insulin delivery (AID) settings is required to achieve desirable glycemic outcomes. We evaluated safety and efficacy of a computerized system to initialize and adjust insulin delivery settings for the t:slim X2 insulin pump with Control-IQ technology in adults with type 1 diabetes (T1D). METHODS: After a 2-week continuous glucose monitoring (CGM) run-in period, adults with T1D using multiple daily injections (MDI) (N = 33, mean age 36.1 years, 57.6% female, diabetes duration 19.7 years) were transitioned to 13 weeks of Control-IQ technology usage. A computerized algorithm generated recommendations for initial pump settings (basal rate, insulin-to-carbohydrate ratio, and correction factor) and weekly follow-up settings to optimize glycemic outcomes. Physicians could override the automated settings changes for safety concerns. RESULTS: Time in range 70 to 180 mg/dL improved from 45.7% during run-in to 69.1% during the last 30 days of Control-IQ use, a median improvement of 18.8% (95% confidence interval [CI]: 13.6-23.9, P < .001). This improvement was evident early in the study and was sustained over 13 weeks. Time <70 mg/dL showed a gradual decreasing trend over time. Percentage of participants achieving HbA1c <7% went from zero at baseline to 55% at study end (P < .001). Only six of the 318 automated settings adaptations (1.9%) were overridden by study investigators. CONCLUSIONS: Computerized initiation and adaptation of Control-IQ technology settings from baseline MDI therapy was safe in adults with T1D. The use of this simplified system for onboarding and optimizing Control-IQ technology may be useful to increase uptake of AID and reduce staff and patient burden in clinical care.

3.
J Diabetes Sci Technol ; 18(1): 10-13, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37605474

RESUMO

BACKGROUND: The t:connect mobile app from Tandem Diabetes Care recently added a feature to allow t:slim X2 insulin pump users to initiate an insulin bolus from their personal smartphone. User experience and user interface considerations prioritized safety and ease of use, and we examined whether the smartphone bolus feature changed bolus behavior in individuals who bolused less than three times/day. METHODS: We performed a retrospective analysis of t:slim X2 insulin pump users in the United States who had remotely updated their insulin pump software to be compatible with the smartphone bolus version of the app and who gave less than three boluses per day prior to the smartphone bolus update. RESULTS: Of the 4470 early adopters who met these criteria, the median number of boluses was 2.2 per day (prior to smartphone bolus update) versus 2.7 per day (after smartphone bolus update), equating to approximately half a bolus more delivered per day (P < .001). Overall, a median of one bolus per day was administered by smartphone app as opposed to being initiated from the screen on the insulin pump. CONCLUSION: This analysis found a significant increase in bolusing behavior among early adopters of the smartphone bolus feature of the t:connect mobile app.


Assuntos
Diabetes Mellitus Tipo 1 , Aplicativos Móveis , Humanos , Insulina , Smartphone , Diabetes Mellitus Tipo 1/tratamento farmacológico , Estudos Retrospectivos , Insulina Regular Humana
4.
J Diabetes Sci Technol ; : 19322968241234072, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38439656

RESUMO

BACKGROUND: Control-IQ technology version 1.5 allows for a wider range of weight and total daily insulin (TDI) entry, in addition to other changes to enhance performance for users with high basal rates. This study evaluated the safety and performance of the updated Control-IQ system for users with basal rates >3 units/h and high TDI in a multicenter, single arm, prospective study. METHODS: Adults with type 1 diabetes (T1D) using continuous subcutaneous insulin infusion (CSII) and at least one basal rate over 3 units/h (N = 34, mean age = 39.9 years, 41.2% female, diabetes duration = 21.8 years) used the t:slim X2 insulin pump with Control-IQ technology version 1.5 for 13 weeks. Primary outcome was safety events (severe hypoglycemia and diabetic ketoacidosis (DKA)). Central laboratory hemoglobin A1c (HbA1c) was measured at system initiation and 13 weeks. Participants continued using glucagon-like peptide-1 (GLP-1) receptor agonists, sodium-glucose transport protein 2 (SGLT-2) inhibitors, or other medications for glycemic control and/or weight loss if on a stable dose. RESULTS: All 34 participants completed the study. Fifteen participants used a basal rate >3 units/h for all 24 hours of the day. Nine participants used >300 units TDI on at least one day during the study. There were no severe hypoglycemia or DKA events. Time in range 70-180 mg/dL was 64.8% over the 13 weeks, with 1.0% time <70 mg/dL. Hemoglobin A1c decreased from 7.69% at baseline to 6.87% at 13 weeks (-0.82%, P < .001). CONCLUSIONS: Control-IQ technology version 1.5, with wider range of weight and TDI input and enhancements for users with high insulin requirements, was safe in individuals with T1D in this study.

5.
Diabetes Ther ; 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39008237

RESUMO

The Tandem t:slim X2 insulin pump is a second-generation automated insulin delivery system with Control-IQ technology. It consists of an X2 insulin pump, an integrated Dexcom sensor, and an embedded 'Control-IQ' algorithm, which predicts glucose levels 30 min in the future, adapting the programmed basal insulin rates to get glucose levels between 112.5 and 160 mg/dl (8.9 mmol/l). The system delivers automatic correction boluses of insulin when glucose levels are predicted to rise > 180 mg/dl (10 mmol/l). It has been commercially available since 2016. We reviewed the current evidence about the psychological, safety, and exercise-related outcomes of this device in children, adolescents, and young adults living with type 1 diabetes. We screened 552 papers, but only 21 manuscripts were included in this review. Fear of hypoglycemia is significantly reduced in young people with diabetes and their parents. Interestingly, diabetes-related distress is decreased; thus, the system is well accepted by the users. The sleeping quality of subjects living with diabetes and their caregivers is improved to a lesser extent as well. Despite the small number of data, this system is associated with a low rate of exercise-related hypoglycemia. Finally, evidence from the literature shows that this system is safe and effective in improving psychological personal outcomes. Even if further steps toward the fully closed loop are still mandatory, this second-generation automated insulin delivery system reduces the burden of diabetes. It properly addresses most psychological issues in children, adolescents, and young adults with type 1 diabetes mellitus; thus, it appears to be well accepted.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA