Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Nucl Cardiol ; 30(6): 2644-2654, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37464251

RESUMO

INTRODUCTION: Myocardial perfusion imaging (MPI) protocols have not changed significantly despite advances in instrumentation and software. We compared an early post-injection, stress-first SPECT protocol to standard delayed imaging. METHODS: 95 patients referred for SPECT MPI were imaged upright and supine on a Spectrum Dynamics D-SPECT CZT system with CT attenuation correction. Patients received injection of 99mTc tetrofosmin at peak of regadenoson stress and were imaged. Early post-stress (mean 17 ± 2 minutes) and Standard 1-h delay (mean 61 ± 13 min). Three blinded readers evaluated images for overall interpretation, perceived need for rest imaging, image quality, and reader confidence. Laboratory efficiency was also evaluated. RESULTS: Blinded readers had the same response for the need for rest in 77.9% of studies. Studies also had the same interpretation in 89.5% of studies. Reader confidence was high (86.0% (Early) and 90.3% (Standard p = 0.52. Image quality was good or excellent in 87.4% Early vs 96.8% Standard (p = 0.09). Time between patient check-in and end of stress imaging was 104 ± (Standard) to 60 ± 18 minutes (Early) (p < 0.001). CONCLUSION: Early post-injection stress-only imaging using CZT SPECT/CT appears promising with Tc-99m tetrofosmin with similar image quality, reader confidence, diagnosis, and need for a rest scan.


Assuntos
Imagem de Perfusão do Miocárdio , Humanos , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Cintilografia , Cádmio , Telúrio
2.
J Nucl Cardiol ; 30(4): 1399-1405, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36352084

RESUMO

BACKGROUND: Residual activity in dispensing syringes is a problem that has been sporadically reported with various radiopharmaceuticals. Studies with [99mTc]Tc-tetrofosmin are non-consistent so far. The aim was to quantify the residual activity of [99mTc]Tc-tetrofosmin in different syringes in a clinical setting and to assess its impact on the clinical imaging procedure. METHODS: The residual activity of [99mTc]Tc-tetrofosmin was measured in 3 types of syringes: 3-part lubricated and non-lubricated syringes and 2-part syringe (n ≥ 30 for each syringe). The residual activity was located and quantified using a CzT SPECT camera and radio-counting then was correlated with different clinical parameters and processed by multiple linear regression analysis. RESULTS: Residual activity was different in all syringe types but lubricated syringes showed significantly higher levels with a mean ± SD of 26.12 ± 10.21% (P < .001). For these syringes, the residual activity was mainly located on the lubricated body. They also have a positive and significant impact on the standardized counting duration of patients' acquisitions. CONCLUSION: Lubricated syringes with high residual activity should be avoided as they increase the risk of prolonging patient acquisition time and potentially increasing the risk of poor image quality.


Assuntos
Imagem de Perfusão do Miocárdio , Seringas , Humanos , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único , Compostos Organofosforados , Compostos de Organotecnécio
3.
J Nucl Cardiol ; 29(3): 1-10, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33083982

RESUMO

BACKGROUND: Left ventricular mechanical dyssynchrony (LVMD) induced by exercise stress was reported to be clinically useful in detecting multivessel coronary artery diseases. The aim of this study was to compare the prognostic value of LVMD induced by pharmacological stress with that induced by exercise stress. METHODS: We retrospectively examined 918 consecutive patients who underwent exercise (N = 310) or pharmacological stress (N = 608) 99mTc-tetrofosmin single-photon emission computed tomography (SPECT) with normal myocardial perfusion. LVMD was evaluated by phase analysis as the indices of phase bandwidth and phase standard deviation (PSD). RESULTS: During the follow-up period (2.2 ± 1.9 years), 74 major cardiac events (MCEs) occurred (7 cases of cardiac death, 17 cases of heart failure, and 50 cases of coronary intervention). In global patients, the indices of LVMD on rest images were significantly greater in patients with MCEs (bandwidth (°): 51 ± 31 vs 37 ± 21, P = .001, PSD: 14 ± 9 vs 10 ± 6, P = .001). The exercise stress bandwidth was significantly higher in patients with MCEs (62 ± 37° vs 42 ± 21°, P = .026), as was the pharmacological stress bandwidth (57 ± 35° vs 43 ± 24°, P = .006). Multivariate analysis demonstrated the exercise stress bandwidth to be an independent predictor of MCEs (HR 1.017, CI 1.003 to 1.032, P = .019), but the pharmacological stress bandwidth had no influence on MCEs. CONCLUSIONS: LVMD induced by exercise stress was an independent predictor of MCEs in patients with normal perfusion SPECT, whereas that induced by pharmacological stress had no association with further events.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Imagem de Perfusão do Miocárdio , Disfunção Ventricular Esquerda , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Humanos , Imagem de Perfusão do Miocárdio/métodos , Perfusão , Prognóstico , Estudos Retrospectivos , Tomografia Computadorizada de Emissão de Fóton Único , Disfunção Ventricular Esquerda/diagnóstico por imagem
4.
Eur J Nucl Med Mol Imaging ; 48(9): 2801-2822, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33839893

RESUMO

INTRODUCTION: Nuclear medicine parathyroid imaging is important in the identification of hyperfunctioning parathyroid glands in primary hyperparathyroidism (pHPT), but it may be also valuable before surgical treatment in secondary hyperparathyroidism (sHPT). Parathyroid radionuclide imaging with scintigraphy or positron emission tomography (PET) is a highly sensitive procedure for the assessment of the presence and number of hyperfunctioning parathyroid glands, located either at typical sites or ectopically. The treatment of pHPT is mostly directed toward minimally invasive parathyroidectomy, especially in cases with a single adenoma. In experienced hands, successful surgery depends mainly on the exact preoperative localization of one or more hyperfunctioning parathyroid adenomas. Failure to preoperatively identify the hyperfunctioning parathyroid gland challenges minimally invasive parathyroidectomy and might require bilateral open neck exploration. METHODS: Over a decade has now passed since the European Association of Nuclear Medicine (EANM) issued the first edition of the guideline on parathyroid imaging, and a number of new insights and techniques have been developed since. The aim of the present document is to provide state-of-the-art guidelines for nuclear medicine physicians performing parathyroid scintigraphy, single-photon emission computed tomography/computed tomography (SPECT/CT), positron emission tomography/computed tomography (PET/CT), and positron emission tomography/magnetic resonance imaging (PET/MRI) in patients with pHPT, as well as in those with sHPT. CONCLUSION: These guidelines are written and authorized by the EANM to promote optimal parathyroid imaging. They will assist nuclear medicine physicians in the detection and correct localization of hyperfunctioning parathyroid lesions.


Assuntos
Hiperparatireoidismo Primário , Medicina Nuclear , Humanos , Hiperparatireoidismo Primário/diagnóstico por imagem , Glândulas Paratireoides/diagnóstico por imagem , Glândulas Paratireoides/cirurgia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Cintilografia , Sensibilidade e Especificidade , Tecnécio Tc 99m Sestamibi
5.
J Nucl Cardiol ; 28(4): 1381-1394, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32236839

RESUMO

Based on superior image quality, more accurate gated images, and lower radiation exposure to patients, Technetium-99m (Tc-99m) based tracers are preferred over Thallium-201 for SPECT myocardial perfusion imaging. The two Tc-99m tracers, sestamibi and tetrofosmin, have many similar characteristics but there are differences in blood and liver clearance rates, as well as the recommended time after injection for imaging to achieve optimal image quality. Because published peer-reviewed studies examining optimal times between injection and imaging are limited, it can be difficult to identify evidence-based opportunities to optimize imaging protocols. Using systematic literature review methods, this study was designed to identify and consolidate the available evidence on the use of sestamibi compared to tetrofosmin for variable injection to imaging times in regard to test efficiency, including test length and re-scan rates, and image quality, including overall quality and cardiac to extra-cardiac ratios. The composite of this data shows that earlier imaging with tetrofosmin is equivalent to later imaging with sestamibi when assessing subjective image quality or when quantifying heart-to-extra-cardiac ratios. Image quality and heart-to-extra-cardiac ratios comparing early versus later imaging with tetrofosmin were comparable if not equivalent to each other. The equivalency of the imaging quality occurs with 15 minutes (on average) earlier imaging compared to sestamibi and 30 minutes compared to standard time tetrofosmin. The subjective findings of equivalent image quality are also shown with objective measurements of heart-to-extra-cardiac ratios. In this review, the significantly shorter injection-to-acquisition times with tetrofosmin compared to sestamibi resulted in better efficiency and less waiting times for patients; in addition, significantly higher re-scan rates with sestamibi compared to tetrofosmin due to hepatic activity contributed to better throughput with tetrofosmin.


Assuntos
Cardiopatias/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Compostos Organofosforados/administração & dosagem , Compostos de Organotecnécio/administração & dosagem , Tecnécio Tc 99m Sestamibi/administração & dosagem , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Fatores de Tempo
6.
J Nucl Cardiol ; 26(3): 763-771, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-28776314

RESUMO

BACKGROUND: SPECT myocardial perfusion imaging (MPI) is a clinical mainstay that is typically performed with static imaging protocols and visually or semi-quantitatively assessed for perfusion defects based upon the relative intensity of myocardial regions. Dynamic cardiac SPECT presents a new imaging technique based on time-varying information of radiotracer distribution, which permits the evaluation of regional myocardial blood flow (MBF) and coronary flow reserve (CFR). In this work, a preliminary feasibility study was conducted in a small patient sample designed to implement a unique combined static-dynamic single-dose one-day visit imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT for improving the diagnosis of coronary artery disease (CAD). METHODS: Fifteen patients (11 males, four females, mean age 71 ± 9 years) were enrolled for a combined dynamic and static SPECT (Infinia Hawkeye 4, GE Healthcare) imaging protocol with a single dose of 99mTc-tetrofosmin administered at rest and a single dose administered at stress in a one-day visit. Out of 15 patients, eleven had selective coronary angiography (SCA), 8 within 6 months and the rest within 24 months of SPECT imaging, without intervening symptoms or interventions. The extent and severity of perfusion defects in each myocardial region was graded visually. Dynamically acquired data were also used to estimate the MBF and CFR. Both visually graded images and estimated CFR were tested against SCA as a reference to evaluate the validity of the methods. RESULTS: Overall, conventional static SPECT was normal in ten patients and abnormal in five patients, dynamic SPECT was normal in 12 patients and abnormal in three patients, and CFR from dynamic SPECT was normal in nine patients and abnormal in six patients. Among those 11 patients with SCA, conventional SPECT was normal in 5, 3 with documented CAD on SCA with an overall accuracy of 64%, sensitivity of 40% and specificity of 83%. Dynamic SPECT image analysis also produced a similar accuracy, sensitivity, and specificity. CFR was normal in 6, each with CAD on SCA with an overall accuracy of 91%, sensitivity of 80%, and specificity of 100%. The mean CFR was significantly lower for SCA detected abnormal than for normal patients (3.86±1.06 vs 1.94±0. 0.67, P < 0.001). CONCLUSIONS: The visually assessed image findings in static and dynamic SPECT are subjective, and may not reflect direct physiologic measures of coronary lesion based on SCA. The CFR measured with dynamic SPECT is fully objective, with better sensitivity and specificity, available only with the data generated from the dynamic SPECT method.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Tecnécio Tc 99m Sestamibi
7.
Eur J Nucl Med Mol Imaging ; 45(10): 1762-1771, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29516131

RESUMO

PURPOSE: In this prospective study we compared the accuracy of 18F-fluorocholine PET/CT with that of 99mTc-MIBI or99mTc-tetrofosmin SPECT/CT in the preoperative detection of parathyroid adenoma in patients with primary hyperparathyroidism. We also assessed the value of semiquantitative parameters in differentiating between parathyroid hyperplasia and adenoma. METHODS: Both 18F-fluorocholine PET/CT and 99mTc-MIBI/tetrofosmin SPECT/CT were performed in 100 consecutive patients with biochemical evidence of primary hyperparathyroidism. At least one abnormal focus on either 18F-fluorocholine or 99mTc-MIBI/tetrofosmin corresponding to a parathyroid gland or ectopic parathyroid tissue was considered as a positive finding. In 76 patients with positive findings on at least one imaging modality, surgical exploration was performed within 6 months, and the results were related to histopathological findings and clinical and laboratory findings at 3-6 months as the standard of truth. In 24 patients, no surgery was performed: in 18 patients with positive imaging findings surgery was refused or considered risky, and in 6 patients imaging was negative. Therefore, data from 82 patients (76 undergoing surgery, 6 without surgery) in whom the standard of truth criteria were met, were used in the final analysis. RESULTS: All patients showed biochemical evidence of primary hyperparathyroidism with a mean serum calcium level of 2.78 ± 0.34 mmol/l and parathormone (PTH) level of 196.5 ± 236.4 pg/ml. The study results in 76 patients with verified histopathology and 3 patients with negative imaging findings were analysed. Three of six patients with negative imaging showed normalized serum PTH and calcium levels on laboratory follow-up at 3 and 6 months, and the results were considered true negative. In a patient-based analysis, the detection rate with 18F-fluorocholine PET/CT was 93% (76/82), but was only 61% (50/82) with 99mTc-MIBI/tetrofosmin SPECT/CT. In a lesion-based analysis, the sensitivity, specificity, positive predictive value, negative predictive value and overall accuracy of 18F-fluorocholine PET/CT in the detection of parathyroid adenoma were 93.7%, 96.0%, 90.2%, 97.4% and 95.3%, respectively, and of 99mTc-MIBI/tetrofosmin SPECT/CT were 60.8%, 98.5%, 94.1%, 86.3% and 87.7%, respectively. Although 18F-fluorocholine PET-positive adenomatous lesions showed higher SUVmax values than the hyperplastic glands (6.80 ± 3.78 vs. 4.53 ± 0.40) in the semiquantitative analysis, the difference was not significant (p = 0.236). The mean size (measured as the length of the greatest dimension) and weight of adenomas were 15.9 ± 7.6 mm (median 15 mm, range 1-40 mm) and 1.71 ± 1.86 g (median 1 g, range: 0.25-9 g), respectively. Among the analysed parameters including serum calcium and PTH and the size and weight of parathyroid adenomas, size was significantly different between patients with negative 99mTc-MIBI/tetrofosmin SPECT/CT and those with positive 99mTc-MIBI/tetrofosmin SPECT/CT (mean size 13.4 ± 7.6 mm vs. 16.9 ± 7.4 mm, respectively; p = 0.042). CONCLUSION: In this prospective study, 18F-fluorocholine PET/CT showed promise as a functional imaging modality, being clearly superior to 99mTc-MIBI/tetrofosmin SPECT/CT, especially in the detection and localization of small parathyroid adenomas in patients with primary hyperparathyroidism. SUVmax was higher in parathyroid adenomas than in hyperplasia. However, further evaluation of this modality is needed.


Assuntos
Colina/análogos & derivados , Hiperparatireoidismo Primário/diagnóstico por imagem , Compostos Organofosforados , Compostos de Organotecnécio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tecnécio Tc 99m Sestamibi , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
8.
Pharm Res ; 36(1): 18, 2018 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-30498970

RESUMO

BACKGROUND: Little is known about the affinity and stability of 99mTc-labeled 2-methoxyisobutylisonitrile (99mTc-MIBI) and tetrofosmin (99mTc-TF) for imaging of multiple drug resistance transporters in cancer. We examined the affinity of 99mTc-labeled compounds for these transporters and their stability. METHODS: 99mTc-MIBI and 99mTc-TF were incubated in vesicles expressing P-glycoprotein (MDR1), multidrug resistance-associated protein (MRP)1-4, or breast cancer resistance protein with and without verapamil (MDR1 inhibitor) or MK-571 (MRP inhibitor). Time activity curves of 99mTc-labeled compounds were established using SK-N-SH neuroblastoma, SK-MEL-28 melanoma, and PC-3 prostate adenocarcinoma cell lines, and transporter expression of multiple drug resistance was measured in these cells. The stability was evaluated. RESULTS: In vesicles, 99mTc-labeled compounds had affinity for MDR1 and MRP1. 99mTc-TF had additional affinity for MRP2 and MRP3. In SK-N-SH cells expressing MDR1 and MRP1, MK-571 produced the highest uptake of both 99mTc-labeled compounds. 99mTc-MIBI uptake with inhibitors was higher than 99mTc-TF uptake with inhibitors. 99mTc-TF was taken up more in SK-MEL-28 cells expressing MRP1 and MRP2 than PC-3 cells expressing MRP1 and MRP3. 99mTc-MIBI was metabolized, whereas 99mTc-TF had high stability. CONCLUSION: 99mTc-MIBI is exported via MDR1 and MRP1 (MRP1 > MDR1) at greater levels and more quickly compared to 99mTc-TF, which is exported via MDR1 and MRP1-3 (MRP1 > MDR1; MRP1, 2 > MRP3). Because 99mTc-MIBI is metabolized, clinical imaging for monitoring MDR and shorter examination times may be possible with an earlier scanning time on late phase imaging. 99mTc-TF has high stability and accurately reflects the function of MDR1 and MRP1-3.


Assuntos
Monitoramento de Medicamentos/métodos , Resistência a Múltiplos Medicamentos , Resistencia a Medicamentos Antineoplásicos , Imagem Molecular/métodos , Proteínas Associadas à Resistência a Múltiplos Medicamentos/metabolismo , Compostos Radiofarmacêuticos/metabolismo , Animais , Linhagem Celular Tumoral , Estabilidade de Medicamentos , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/metabolismo , Camundongos SCID , Proteínas Associadas à Resistência a Múltiplos Medicamentos/antagonistas & inibidores , Neoplasias/diagnóstico por imagem , Neoplasias/tratamento farmacológico , Compostos Organofosforados/química , Compostos Organofosforados/metabolismo , Compostos de Organotecnécio/química , Compostos de Organotecnécio/metabolismo , Propionatos/farmacologia , Quinolinas/farmacologia , Compostos Radiofarmacêuticos/química , Fatores de Tempo , Verapamil/farmacologia , Ensaios Antitumorais Modelo de Xenoenxerto
9.
J Nucl Cardiol ; 25(1): 63-71, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-27381341

RESUMO

BACKGROUND: Dobutamine stress myocardial perfusion imaging (MPI) is a useful alternative for the evaluation of coronary artery disease (CAD) in elderly patients who are unable to perform an exercise stress test. However, data on the long-term prognostic value of stress MPI in elderly patients are lacking. Therefore, this study evaluated the long-term prognostic value of dobutamine stress MPI in elderly patients unable to perform an exercise test. METHODS: The study population consisted of 247 elderly patients (mean age 71 ± 5 years) who underwent dobutamine stress single-photon emission computed tomography (SPECT) MPI. An abnormal SPECT study was defined as the presence of fixed and/or reversible perfusion defects. A summed stress score (SSS) was obtained to estimate the extent and severity of perfusion defects. End points during follow-up were all-cause mortality, cardiac mortality, and nonfatal myocardial infarction (MI). RESULTS: During a median follow-up of 14 years (range 12-16), 168 (68%) patients died (all-cause mortality), of which 56 (23%) were due to cardiac causes. Nonfatal MI occurred in 19 (8%) patients. Kaplan-Meier survival curves showed that MPI provided optimal risk stratification in patients with normal and abnormal MPI. Multivariable analysis identified an abnormal MPI as a strong significant predictor of all-cause mortality and cardiac events. A multivariable analysis also revealed that a reversible defect and SSS were strong long-term predictors of cardiac mortality and hard cardiac events. CONCLUSION: Dobutamine stress 99mTc-tetrofosmin SPECT provides incremental prognostic information for the prediction of long-term cardiovascular outcomes in elderly patients, unable to perform exercise testing. Dobutamine stress MPI is useful in risk classifying elderly patients.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/mortalidade , Progressão da Doença , Dobutamina , Teste de Esforço , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Infarto do Miocárdio/diagnóstico por imagem , Compostos Organofosforados , Compostos de Organotecnécio , Prognóstico , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Resultado do Tratamento
10.
J Nucl Cardiol ; 25(5): 1875-1878, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29147830

RESUMO

An 83-year-old man underwent exercise stress test with single photon emission computed tomography (SPECT) myocardial perfusion imaging for new electrocardiogram (EKG) changes. The stress EKG did not show any significant changes. Myocardial perfusion imaging with SPECT demonstrated an inferior wall defect and extracardiac uptake of nuclear tracer. Simultaneous cardiac computed tomography performed for attenuation correction showed presence of intrapericardial hepatic tissue in an anterior diaphragmatic hernia. The herniated tissue was noted to influence the perfusion image and cause the defect. To date, this is a unique finding based on review of literature.


Assuntos
Hérnias Diafragmáticas Congênitas/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso de 80 Anos ou mais , Eletrocardiografia , Hérnias Diafragmáticas Congênitas/patologia , Humanos , Fígado/patologia , Masculino , Pericárdio/patologia
11.
J Nucl Cardiol ; 24(4): 1314-1327, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-26976142

RESUMO

BACKGROUND: We attempted to validate the performance of a fast myocardial perfusion imaging (MPI) protocol in diagnostically challenging patients. METHODS: 78 patients with ΒΜΙ > 24.9, LVH or three vessels disease underwent two sequential gated-MPI studies. The first at 15 (Early Imaging, EI) and the second at 45 (Late Imaging, LI) minutes post 99mTc-injection, at both stress and rest. Counts over heart (H), liver (Liv) and subdiaphragmatic space (Sub) and image quality, and myocardial perfusion and function parameters were compared between the two protocols. Coronary angiography was performed within 2 months from MPI, and ROC analysis was used to compare the diagnostic accuracy for the detection of ≥50% diameter luminal stenosis. RESULTS: Quality was optimal-good in 93% of EI and 98% of LI studies (P = .12), H/Liv and stress H/Sub ratios were similar, but rest H/Sub ratio was lower in EI (P = .009). SSS [10 (0 to 46) vs 9 (0 to 36), P = .006] and SDS [3 (0 to 35) vs 2 (0 to 34), P = .02] were higher in EI protocol. LVEF, motion and thickening scores did not differ between the two protocols. A highly significant (P < .001) linear relationship with clinically negligible mean differences in Bland-Altman analysis was observed for all perfusion and function-related data. Sensitivity (EI 81%, LI 80%) and specificity (65% for both) did not differ (P = .23) between the two protocols. CONCLUSION: The fast protocol is technically feasible and diagnostically accurate compared to the established protocol in diagnostically challenging patients.


Assuntos
Imagem de Perfusão do Miocárdio/métodos , Compostos de Organotecnécio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Protocolos Clínicos , Angiografia Coronária , Feminino , Câmaras gama , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Curva ROC
12.
Folia Med (Plovdiv) ; 59(4): 396-404, 2017 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-29341944

RESUMO

Considered rare disease in the past, primary hyperparathyroidism (PHPT) has dramatically increased in incidence over the past thirty years with the introduction of routine calcium measurements; it is now approximately 42 per 100 000 persons. By far, the most common lesion found in patients with PHPT is the solitary parathyroid adenoma, occurring in 85%-90% of patients, while in the rest 10%- 15% primary hyperplasia of the parathyroid glands is present. Currently, the most widely used surgical approach is minimally invasive parathyroidectomy which is associated with less post-surgery complications and shorter operation time. To be successful this procedure needs to rely on a precise preoperative localization of the abnormal parathyroid glands, hence preoperative parathyroid imaging gained so large importance. The rationale for locating abnormal parathyroid tissue prior to surgery is that the glands can be notoriously unpredictable in their location. There is a general consensus that the best imaging procedure identifying abnormal parathyroid glands is the preoperative scintigraphy with 99mTc-sestamibi or 99mTc-tetrofosmin. It is characterized with high sensitivity and specificity exceeding those of ultrasound, CT or MRI. Combining scintigraphy with the other imaging techniques increases the precision for topic localization.


Assuntos
Hiperparatireoidismo Primário/diagnóstico por imagem , Hiperparatireoidismo Secundário/diagnóstico por imagem , Medicina Nuclear/métodos , Glândulas Paratireoides/diagnóstico por imagem , Humanos , Compostos Organofosforados , Compostos de Organotecnécio , Glândulas Paratireoides/anatomia & histologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tecnécio Tc 99m Sestamibi
13.
J Pineal Res ; 60(1): 3-15, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26292662

RESUMO

The occurrence of metastasis, an important breast cancer prognostic factor, depends on cell migration/invasion mechanisms, which can be controlled by regulatory and effector molecules such as Rho-associated kinase protein (ROCK-1). Increased expression of this protein promotes tumor growth and metastasis, which can be restricted by ROCK-1 inhibitors. Melatonin has shown oncostatic, antimetastatic, and anti-angiogenic effects and can modulate ROCK-1 expression. Metastatic and nonmetastatic breast cancer cell lines were treated with melatonin as well as with specific ROCK-1 inhibitor (Y27632). Cell viability, cell migration/invasion, and ROCK-1 gene expression and protein expression were determined in vitro. In vivo lung metastasis study was performed using female athymic nude mice treated with either melatonin or Y27832 for 2 and 5 wk. The metastases were evaluated by X-ray computed tomography and single photon emission computed tomography (SPECT) and by immunohistochemistry for ROCK-1 and cytokeratin proteins. Melatonin and Y27632 treatments reduced cell viability and invasion/migration of both cell lines and decreased ROCK-1 gene expression in metastatic cells and protein expression in nonmetastatic cell line. The numbers of 'hot' spots (lung metastasis) identified by SPECT images were significantly lower in treated groups. ROCK-1 protein expression also was decreased in metastatic foci of treated groups. Melatonin has shown to be effective in controlling metastatic breast cancer in vitro and in vivo, not only via inhibition of the proliferation of tumor cells but also through direct antagonism of metastatic mechanism of cells rendered by ROCK-1 inhibition. When Y27632 was used, the effects were similar to those found with melatonin treatment.


Assuntos
Amidas/farmacologia , Neoplasias da Mama/tratamento farmacológico , Melatonina/farmacologia , Proteínas de Neoplasias/antagonistas & inibidores , Piridinas/farmacologia , Quinases Associadas a rho/antagonistas & inibidores , Animais , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/enzimologia , Neoplasias da Mama/patologia , Linhagem Celular Tumoral , Feminino , Humanos , Camundongos , Camundongos Nus , Metástase Neoplásica , Proteínas de Neoplasias/metabolismo , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Ensaios Antitumorais Modelo de Xenoenxerto , Quinases Associadas a rho/metabolismo
14.
J Nucl Cardiol ; 23(6): 1470-1476, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-26719152

RESUMO

BACKGROUND: Combined supine-prone myocardial perfusion imaging (CSP MPI) has been shown to reduce attenuation artifact in comparison to supine-only (SU) MPI in mixed-gender populations with varying risk for coronary artery disease (CAD), often where patients served as their own controls. However, there is limited direct comparison of these imaging strategies in men. METHODS: 934 male patients underwent CSP or SU MPI. Diagnostic certainty of interpretation was compared. Within the cohort, 116 were referred for left heart catheterization (LHC) to assess for CAD. Sensitivity, specificity, and area under the curve (AUC) were compared with additional analysis based on body mass index (BMI). RESULTS: 597 patients completed the SU protocol and 337 patients completed the CSP protocol. Equivocal studies were seen more frequently in the SU group (13%) than in the CSP group (4%, P < .001). At catheterization, the specificity for CSP MPI of 70% was higher than 40% for SU MPI (P = .032). The CSP AUC (0.80 ± 0.06) was significantly larger than SU AUC (0.57 ± 0.05, P = .004). CSP specificity was significantly higher in obese patients. CONCLUSIONS: CSP MPI increases diagnostic certainty and improves test accuracy for CAD detection in men with CAD risk factors, especially obese patients, compared to SU MPI.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Obesidade/epidemiologia , Posicionamento do Paciente/estatística & dados numéricos , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Comorbidade , Feminino , Florida/epidemiologia , Humanos , Masculino , Saúde do Homem , Imagem de Perfusão do Miocárdio/métodos , Obesidade/diagnóstico por imagem , Posicionamento do Paciente/métodos , Prevalência , Decúbito Ventral , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Decúbito Dorsal
15.
J Nucl Cardiol ; 22(5): 1019-30, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25515421

RESUMO

BACKGROUND: Respiratory-related cardiac motion could have considerable effects on myocardial perfusion imaging, leading to misinterpretation of the images. In this study, we examined the influence of respiratory correction on ECG-gated myocardial perfusion SPECT (RC-GSPECT) concerning regional myocardial perfusion and function. MATERIALS AND METHODS: Using the NCAT phantom, a typical torso phantom was generated. SimSET, a Monte Carlo simulator, was used to image the photon emerging from the phantom. Twenty-six patients underwent a 2-day stress-rest ECG-gated myocardial perfusion SPECT (GSPECT) imaging. A separate study was also performed by simultaneous respiratory and cardiac triggering with the real-time position management (RPM) for respiratory correction (RC). RESULTS: In simulation study, count density in the inferior and inferoseptal walls increased in the lower bin of the respiratory cycle. On the other hand, there was a higher correlation between RC-GSPECT and echocardiography for left ventricular ejection fraction (LVEF) (r = 0.95, P < .01 vs r = 0.88, P < .01 for GSPECT). CONCLUSION: We proposed a new approach for respiratory and cardiac-gated SPECT to eliminate respiratory motion artifacts. RC-GSPECT is a feasible method in MPI studies and may play an important role to improve the quality of MPI images, particularly in the inferior wall.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Imagem de Perfusão do Miocárdio , Respiração , Idoso , Artefatos , Simulação por Computador , Ecocardiografia , Teste de Esforço , Feminino , Imagem do Acúmulo Cardíaco de Comporta , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Movimento , Imagens de Fantasmas , Compostos Radiofarmacêuticos , Tecnécio/química , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda
16.
Clin Cases Miner Bone Metab ; 11(1): 25-30, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25002876

RESUMO

OBJECTIVE: Technetium Parathyroid Scintigraphy (TS) is the most popular noninvasive localization procedure in patients with primary hyperparathyroidism (PHPT). Awareness of various factors involved in technetium uptake helps understand the outcome of TS. METHODS: We utilize a case of changing TS scans in a patient to review the literature on the various biological and technical factors involved in technetium uptake by the abnormal parathyroid tissue. A 56 year female was diagnosed with PHPT and osteopenia. An initial scan using (99m)Tc-Tetrofosmin showed no definite areas of abnormal parathyroid tissue. Patient refused surgical exploration, was started on Bisphosponates and subsequently monitored. Five years later she suffered fracture of her right wrist. A repeat TS using (99m)Tc-Sestamibi revealed hypervascular parathyroid lesion in the right lower neck. She underwent successful removal of a right lower parathyroid adenoma. RESULTS: Technical factors like the type of Tc isotope used, imaging techniques and biological factors like biochemical parameters (calcium, vitamin D levels), adenoma size, content of oxyphilic cells, vascularity can affect the outcome of the scan. CONCLUSION: Clinicians should be aware of technical and biological factors that could result in negative scan in parathyroid nuclear scintigraphy.

17.
J Nucl Med Technol ; 52(3): 239-246, 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39137982

RESUMO

Myocardial perfusion imaging (MPI) provides physiologic and functional information about the heart muscle and its blood flow. Extracardiac radioactivity can interfere with visualization of the inferior wall of the myocardium, leading to poor-quality images, difficulties in interpretation, and delays in routine practice. This study aimed to identify the efficiency of having the patient consume a carbonated lemon drink to minimize the extracardiac radioactivity of 99mTc-sestamibi in comparison to 99mTc-tetrofosmin during MPI. Methods: This was a retrospective study that recruited 158 patients with known or suspected coronary artery disease referred to undergo 99mTc-sestamibi or 99mTc-tetrofosmin rest/stress single-day MPI. The patients were divided into 2 groups of mixed sexes and different ages. The first group comprised 78 patients injected with 99mTc-sestamibi, and the second group comprised 80 patients injected with 99mTc-tetrofosmin. For both groups, the patients drank 30 mL of fresh lemon juice diluted with 150 mL of soda water, and then we gave the patients about 100 mL of straight soda water, before imaging for both the rest and the stress phases. Results: Generally, in both groups, the 99mTc-tetrofosmin produced a good-quality image in comparison with the 99mTc-sestamibi. The mean rank of the total score for 99mTc-tetrofosmin (62.75) was less than that for 99mTc-sestamibi (96.68), and this difference was highly statistically significant (P = 0.000). There were statistically significant differences in the ratios and mean ranks for both groups in favor of 99mTc-tetrofosmin in patients having coronary artery disease. Conclusion: The use of a carbonated lemon drink minimizes extracardiac activity from both 99mTc-labeled MPI radiopharmaceuticals. This finding was more statistically significant for 99mTc-tetrofosmin MPI, providing better image quality and earlier imaging in both the rest and the stress phases because of faster hepatobiliary clearance.


Assuntos
Citrus , Imagem de Perfusão do Miocárdio , Compostos Organofosforados , Compostos de Organotecnécio , Humanos , Imagem de Perfusão do Miocárdio/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Tecnécio Tc 99m Sestamibi , Bebidas Gaseificadas , Doença da Artéria Coronariana/diagnóstico por imagem
18.
World J Nucl Med ; 21(4): 314-319, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36398310

RESUMO

Objective The aim of this study is to establish a method for the fractionation of tetrofosmin cold kit under different storage conditions and to optimize an alternate chromatography method from the reference method to test radiochemical purity (RCP). Materials and Methods Tetrofosmin cold kit vial was fractionated aseptically in six equal fractions and stored in vials and syringes. To test the stability of the reconstituted solution for a longer duration, the mother vials and syringes were stored at two different temperatures, that is, at 4°C and at -20°C till further used. Radiolabeling of fractionated tetrofosmin was performed as per the standard labeling protocol. Radionuclide purity, radioassay, and pH were tested. Radiolabeling efficiency and RCP were determined by paper chromatography. Results Radionuclide purity of eluate was greater than 99.9%. The pH of technetium-99m (Tc-99m) eluate and Tc-99m tetrofosmin was between 4.5-7.5 and 7.5-9.5, respectively. The deviation in the radioactivity during all measurements was less than 1%. The kits fractioned in glass vials resulted in higher radiolabeling yield and RCP as compared with kits fractionated in syringes. The RCP of glass vial versus syringe was observed to be greater than 95 versus 90% and 95 versus 80% at -20°C and 4°C, respectively. Conclusion Tetrofosmin kit can be used in a cost-effective manner by fractionation. One tetrofosmin vial can be used in six fractions for up to 15 days when stored at -20°C and 4°C freezer temperature. The alternative method to check the RCP of Tc-99m tetrofosmin is safer and less time consuming as compared with the reference method.

19.
Folia Med (Plovdiv) ; 64(1): 181-186, 2022 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-35851889

RESUMO

We present a case of a 47-year-old woman with type 1 multiple endocrine neoplasia, primary hyperparathyroidism, insulinoma, and nonfunctioning pituitary adenoma. In July 2017, the patient was referred to the Department of Nuclear Medicine of St George University Hospital in Plovdiv for a PET/CT scan because of persistent hypoglycemic episodes and high serum insulin levels. A whole-body PET/CT examination was performed 65 min after intravenous application of 188 MBq 18F-FDG on a hybrid PET/CT scanner (Biograph mCT 64, Siemens). We detected a low metabolically active lesion 10 mm in diameter (SUVmax - 2.00), located below the left thyroid lobe suspicious for parathyroid adenoma. In the remaining scanned areas there were no PET/CT data for other areas with increased glucose metabolism with malignant characteristics that could be associated with the underlying disease.


Assuntos
Fluordesoxiglucose F18 , Neoplasia Endócrina Múltipla Tipo 1 , Feminino , Humanos , Isótopos , Pessoa de Meia-Idade , Neoplasia Endócrina Múltipla Tipo 1/diagnóstico por imagem , Compostos Organofosforados , Compostos de Organotecnécio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Cintilografia , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único/métodos
20.
Comput Biol Med ; 141: 105164, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34971980

RESUMO

AIM: The purpose of this study was to automatically extract myocardial regions from transaxial single-photon emission computed tomography (SPECT) images using deep learning to reduce the effects of extracardiac activity, which has been problematic in cardiac nuclear imaging. METHOD: Myocardial region extraction was performed using two deep neural network architectures, U-Net and U-Net ++, and 694 myocardial SPECT images manually labeled with myocardial regions were used as the training data. In addition, a multi-slice input method was introduced during the learning session while taking the relationships to adjacent slices into account. Accuracy was assessed using Dice coefficients at both the slice and pixel levels, and the most effective number of input slices was determined. RESULTS: The Dice coefficient was 0.918 at the pixel level, and there were no false positives at the slice level using U-Net++ with 9 input slices. CONCLUSION: The proposed system based on U-Net++ with multi-slice input provided highly accurate myocardial region extraction and reduced the effects of extracardiac activity in myocardial SPECT images.


Assuntos
Aprendizado Profundo , Redes Neurais de Computação , Perfusão , Tomografia Computadorizada de Emissão de Fóton Único
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA