Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 209
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(6): 1095-1100, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38511484

RESUMO

INTRODUCTION: In cryoballoon ablation (CBA) procedures, transseptal access (TSA) is generally achieved using a standard sheath and needle system that is exchanged for the cryoballoon delivery sheath and dilator over a long wire. Sheath exchange has been related with air embolic events. Recently, an integrated dilator-needle system assembled to the cryoballoon sheath was introduced. We aimed to evaluate the efficacy and safety of an integrated TSA tool compared with the traditional approach in atrial fibrillation CBA procedures. METHODS: Patients scheduled for CBA procedures were randomized 1:1 to traditional TSA (t-TSA) or integrated TSA (i-TSA). TSA time was defined as time from superior vena cava to LA insertion of the cryoballoon delivery sheath, after sheath exchange (t-TSA) or directly (i-TSA). RESULTS: Ninety-seven patients (76 males, mean age 59 ± 10 years) were randomized, 48 patients underwent t-TSA, and 49 i-TSA. Mean TSA time was 5 min 59 s ± 5 min 36 s in the t-TSA group and 2 min 59 s ± 2 min 14 s in the i-TSA group (p < .001). Total fluoroscopy time, skin-to-skin procedure time, and LA dwell time were respectively 15 ± 6, 69 ± 16, and 44 ± 12 min in the t-TSA group and 13 ± 6, 65 ± 15, and 43 ± 11 min in the i-TSA group (p = ns). No clinically significant acute complications related to TSA were noted in both cohorts. CONCLUSION: This is the first randomized study comparing both TSA approaches. TSA in CBA procedures using this integrated tool enables a safe and efficient workflow, reducing TSA time and avoiding sheath exchange.


Assuntos
Fibrilação Atrial , Criocirurgia , Desenho de Equipamento , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Criocirurgia/instrumentação , Criocirurgia/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Fatores de Tempo , Cateteres Cardíacos , Duração da Cirurgia , Agulhas , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Estudos Prospectivos , Frequência Cardíaca , Potenciais de Ação
2.
J Cardiovasc Electrophysiol ; 35(1): 16-24, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37890041

RESUMO

INTRODUCTION: Mechanical force to achieve transseptal puncture (TSP) using a standard needle may lead to overshooting and injury, and can potentially be avoided using a radiofrequency (RF)-powered needle or wire. Applying electrocautery to needles and guidewires as an alternative to purpose-built RF systems has been associated with safety risks, such as tissue coring and thermal damage. The commercially available AcQCross needle-dilator system (Medtronic) features a sharp open-ended needle for mechanical puncture, as well as a built-in connector to enable energy delivery for RF puncture. This investigation compares the safety and efficacy of the AcQCross needle to the dedicated VersaCross RF wire system and generator (Baylis Medical/Boston Scientific). METHODS: In an ex vivo porcine model, VersaCross wire punctures were performed using 1 s, constant mode (approx. 10 W) with maximum two attempts. AcQCross punctures were performed by applying energy for 2 s using a standard electrosurgical generator at 10 W (max. five attempts), 20 W (max. two attempts), and 30 W (max. two attempts). Efficacy was assessed in terms of puncture success and a number of energy applications required for TSP. Safety was assessed quantitatively as force required for TSP, energy required to puncture, and incidence of tissue coring, as well as by qualitative assessment of puncture sites. Additional qualitative observation of tissue cores and debris were obtained from TSP performed in live swine. RESULTS: RF TSP was 100% successful using the VersaCross wire with 1.0 ± 0.0 attempts. When power was used with the AcQCross needle, it failed to puncture at low (10 and 20 W) power settings; TSP was achieved with 30 W of energy with 91% success using 1.53 ± 0.51 attempts (p < .05 vs. VC) with greater variability (F1,33 = 9223.5, p < .0001). Compared to RF puncture using the VersaCross system, mechanical puncture, alone, using the AcQcross needle required six times more force (8 mm additional forward device displacement) to perforate the septum. Qualitative assessment of puncture sites revealed larger defects and more tissue charring with the AcQCross needle at 30 W compared to punctures with VersaCross wire. Tissue coring with the open-ended AcQCross needle was observed in vivo and measured to occur in 57% of punctures using the ex vivo model; no coring was observed with the closed-tip VersaCross wire. CONCLUSIONS: The AcQCross needle frequently required higher energy of 30 W to achieve RF TSP and was associated with tissue coring and charring, which have been, previously, reported when electrifying a standard open-ended mechanical needle or guidewire. These findings may limit safety and effectiveness compared to the VersaCross system.


Assuntos
Ablação por Cateter , Suínos , Animais , Desenho de Equipamento , Eletrocoagulação , Agulhas , Punções , Modelos Animais , Resultado do Tratamento
3.
Rev Cardiovasc Med ; 25(5): 170, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-39076496

RESUMO

Background: Transseptal puncture (TSP) performed with the Brockenbrough (BRK) needle is technically demanding and carries potential risks. The back end of the percutaneous transluminal coronary angioplasty (PTCA) guidewire is blunt and flexible, with good support, it can puncture the right ventricle-free wall, which is thicker than the atrial-septum. The guidewire is thin and easy to manipulate. This study evaluated the performance of TSP with a PTCA guidewire and microcatheter without a needle. Methods: The back end of a PTCA guidewire was advanced into the Tiger (TIG) catheter, within the SL1 sheath, to puncture the fossa ovalis (FO) under fluoroscopy. Subsequently, the microcatheter was inserted into the left atrium (LA) above the guidewire, and the front end of the guidewire was exchanged in the LA. After the puncture site was confirmed by contrast, the TIG catheter and a 0.032 inch wire were advanced into the LA. Finally, the sheath, with the dilator, was advanced over the wire into the LA. The safety margin of this method was tested in a pig model. Results: The puncture was successful in all seven pigs tested with a puncture-to-sheath entry time of < 20 minutes and no procedure-related complications. The method was successfully used to perform a difficult TSP in a patient with an extremely tortuous inferior vena cava, in whom puncture with a BRK needle had repeatedly failed. Conclusions: Cardiologists may use the PTCA guidewire and microcatheter as an alternative to the needle while performing TSP in special conditions, such as an extremely tortuous inferior vena cava.

4.
Rev Cardiovasc Med ; 25(2): 38, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-39077341

RESUMO

Background: Percutaneous radiofrequency catheter ablation (RFA) in hypertrophic obstructive cardiomyopathy (HOCM) with intracardiac echocardiography (ICE) guidance is a novel method that has been proven to be safe and effective in a small sample size study. RFA of the interventricular septum through a trans-atrial septal approach in HOCM patients with a longer follow-up has not been reported. Methods: 62 consecutive patients from March 2019 to February 2022 were included in this study. The area between the hypertrophied septum and anterior mitral valve (MV) leaflet was established using the three-dimensional system (CARTO 3 system), and all patients received atrial septal puncture under the guidance of intracardiac echocardiography (ICE). Point-by-point ablation was performed to cover the contact area. After ablation, the patients were followed up for 1, 3, 6, and 12 months. Transthoracic echocardiography was performed at 1, 3, 6, and 12 months, and resting and exercise-provoked left ventricular outflow tract (LVOT) gradients were obtained. Results: During the 1-year follow-up, most patients' symptoms improved. The NYHA grading of the patient decreased from 2 (2, 3) at baseline to 2 (1, 2) (p < 0.001). LVOT peak gradient at rest was decreased from 59 ( ± 27) mmHg to 30 ( ± 24) mmHg (p < 0.001), and the provoked peak gradient was decreased from 99 ( ± 33) mmHg to 59 ( ± 34) mmHg (p < 0.001). The average maximum septal thickness was reduced from 21 ( ± 4) mm to 19 ( ± 4) mm (p < 0.001). Conclusions: After a 1-year follow-up, ice-guided radiofrequency ablation for HOCM might be a safe, accurate, and effective method. The catheter might be reliably attached to the ablation target area via trans-atrial septal access.

5.
Catheter Cardiovasc Interv ; 103(7): 1138-1144, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38695165

RESUMO

Following the introduction in the latest European and American guidelines, transcatheter edge-to-edge repair has become a valid alternative to surgery for ineligible patients. Among the available technologies, MitraClip (Abbott) was the first to be introduced for the percutaneous treatment of mitral regurgitation with the edge-to-edge technique. Although its safety and effectiveness has been widely demonstrated, the optimal procedural results are highly dependent from operators' experience. In this manuscript, we provide a full guide of advanced steering maneuvers of MitraClip in different scenarios of transseptal puncture.


Assuntos
Cateterismo Cardíaco , Cateteres Cardíacos , Insuficiência da Valva Mitral , Valva Mitral , Punções , Humanos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Desenho de Equipamento , Septos Cardíacos/cirurgia , Septos Cardíacos/diagnóstico por imagem , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Resultado do Tratamento
6.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38366154

RESUMO

AIMS: Common to adult electrophysiology studies (EPSs), intracardiac echocardiography (ICE) use in paediatric and congenital heart disease (CHD) EPS is limited. The purpose of this study was to assess the efficacy of ICE use and incidence of associated complications in paediatric and CHD EPS. METHODS AND RESULTS: This single-centre retrospective matched cohort study reviewed EPS between 2013 and 2022. Demographics, CHD type, and EPS data were collected. Intracardiac echocardiography cases were matched 1:1 to no ICE controls to assess differences in complications, ablation success, fluoroscopy exposure, procedure duration, and arrhythmia recurrence. Cases and controls with preceding EPS within 5 years were excluded. Intracardiac echocardiography cases without an appropriate match were excluded from comparative analyses but included in the descriptive cohort. We performed univariable and multivariable logistic regression to assess associations between variables and outcomes. A total of 335 EPS were reviewed, with ICE used in 196. The median age of ICE cases was 15 [interquartile range (IQR) 12-17; range 3-47] years, and median weight 57 [IQR 45-71; range 15-134] kg. There were no ICE-related acute or post-procedural complications. There were 139 ICE cases matched to no ICE controls. Baseline demographics and anthropometrics were similar between cases and controls. Fluoroscopy exposure (P = 0.02), procedure duration (P = 0.01), and arrhythmia recurrence (P = 0.01) were significantly lower in ICE cases. CONCLUSION: Intracardiac echocardiography in paediatric and CHD ablations is safe and reduces procedure duration, fluoroscopy exposure, and arrhythmia recurrence. However, not every arrhythmia substrate requires ICE use. Thoughtful selection will ensure the judicious and strategic application of ICE to enhance outcomes.


Assuntos
Ablação por Cateter , Cardiopatias Congênitas , Adulto , Humanos , Criança , Estudos Retrospectivos , Estudos de Coortes , Resultado do Tratamento , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/cirurgia , Ecocardiografia/métodos , Fluoroscopia , Ablação por Cateter/efeitos adversos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia
7.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38619048

RESUMO

AIMS: A three-dimensional electroanatomic mapping system-guided transseptal puncture (3D-TSP), without fluoroscopy or echocardiography, has been only minimally reported. Indications for 3D-TSP remain unclear. Against this background, this study aims to establish a precise technique and create a workflow for validating and selecting eligible patients for fluoroless 3D-TSP. METHODS AND RESULTS: We developed a new methodology for 3D-TSP based on a unipolar electrogram derived from a transseptal needle tip (UEGM tip) in 102 patients (the derivation cohort) with intracardiac echocardiography (ICE) from March 2018 to February 2019. The apparent current of injury (COI) was recorded at the muscular limbus of the foramen ovalis (FO) on the UEGM tip (sinus rhythm: 2.57 ± 0.95 mV, atrial fibrillation: 1.92 ± 0.77 mV), which then disappeared or significantly reduced at the central FO. Changes in the COI, serving as a major criterion to establish a 3D-TSP workflow, proved to be the most valuable indicator for identifying the FO in 99% (101/102) of patients compared with three previous techniques (three minor criteria) of reduction in atrial unipolar or bipolar potential and FO protrusion. A total of 99.9% (1042/1043) patients in the validation cohort underwent successful 3D-TSP through the workflow from March 2019 to July 2023. Intracardiac echocardiography guidance was required for 6.6% (69/1042) of patients. All four criteria were met in 740 patients, resulting in a 100% pure fluoroless 3D-TSP success rate. CONCLUSION: In most patients, fluoroless 3D-TSP was successfully achieved using changes in the COI on the UEGM tip. Patients who met all four criteria were considered suitable for 3D-TSP, while those who met none required ICE guidance.


Assuntos
Fibrilação Atrial , Técnicas Eletrofisiológicas Cardíacas , Imageamento Tridimensional , Punções , Humanos , Masculino , Feminino , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Técnicas Eletrofisiológicas Cardíacas/métodos , Idoso , Pessoa de Meia-Idade , Ablação por Cateter/métodos , Ablação por Cateter/instrumentação , Agulhas , Septos Cardíacos/cirurgia , Septos Cardíacos/diagnóstico por imagem , Fluxo de Trabalho , Ecocardiografia
8.
Curr Cardiol Rep ; 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38995505

RESUMO

PURPOSE OF THE REVIEW: Intracardiac echocardiography (ICE) provides real-time, fluoroless imaging of cardiac structures, allowing optimal catheter positioning and energy delivery during ablation procedures. This review summarizes the use of ICE in catheter ablation of atrial fibrillation (AF). RECENT FINDINGS: Growing evidence suggests that the use of ICE improves procedural safety and facilitates radiofrequency and cryoballoon AF ablation. ICE-guided catheter ablation is associated with reduced procedural duration and fluoroscopy use. Recent studies have examined the role of ICE in guiding novel ablation techniques, such as pulsed field ablation. Finally, the use of ICE allows for early detection and timely management of potentially serious procedural complications. Intracardiac echocardiography offers significant advantages during AF ablation procedures and its use should be encouraged to improve procedural safety and efficacy.

9.
Indian Pacing Electrophysiol J ; 24(1): 35-39, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37804946

RESUMO

BACKGROUND: While steerable sheaths are widely used to improve catheter stability and contact force during radiofrequency (RF) catheter ablation in patients with atrial fibrillation (AF), steerable sheaths are less commonly used during transseptal puncture. This study evaluated whether left atrial catheterization efficiency can be improved using the VersaCross combined steerable sheath and transseptal system compared to previous standard workflow. METHODS: This study retrospectively analyzed AF ablation performed using the VersaCross Workflow consisting of VersaCross steerable sheath and RF wire for transseptal puncture and catheter ablation (VCW) to the standard workflow using a fixed curve sheath with RF needle followed by exchange for an Agilis steerable sheath for catheter ablation (STW). RESULTS: Thirty patients underwent RF ablation for paroxysmal or persistent AF, 15 using the VCW and 15 using the STW. Transseptal puncture time was 10.8 mins faster with the VCW compared to the standard workflow (20.9 ± 5.9 min vs. 31.7 ± 15.1 min; p = 0.024). Time to left atrial catheterization was 40% faster with the VCW compared to the STW (21.3 ± 5.8 min vs. 35.2 ± 14.4 min; p = 0.003). Overall procedure time was 14.2 min faster in the VCW compared to the STW (86.3 ± 16.1 min vs. 100.5 ± 19.3 min; p = 0.044). CONCLUSIONS: Use of the VersaCross steerable system significantly reduced time to transseptal puncture, time to left atrial catheterization, and overall RF ablation time.

10.
J Cardiovasc Electrophysiol ; 34(2): 382-388, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36423239

RESUMO

INTRODUCTION: Transseptal puncture (TSP) is routinely performed for left atrial ablation procedures. The use of a three-dimensional (3D) mapping system or intracardiac echocardiography (ICE) is useful in localizing the fossa ovalis and reducing fluoroscopy use. We aimed to compare the safety and efficacy between 3D mapping system-guided TSP and ICE-guided TSP techniques. METHODS: We conducted a prospective observational study of patients undergoing TSP for left atrial catheter ablation procedures (mostly atrial fibrillation ablation). Propensity scoring was used to match patients undergoing 3D-guided TSP with patients undergoing ICE-guided TSP. Logistic regression was used to compare the clinical data, procedural data, fluoroscopy time, success rate, and complications between the groups. RESULTS: Sixty-five patients underwent 3D-guided TSP, and 151 propensity score-matched patients underwent ICE-guided TSP. The TSP success rate was 100% in both the 3D-guided and ICE-guided groups. Median needle time was 4.00 min (interquartile range [IQR]: 2.57-5.08) in patients with 3D-guided TSP compared to 4.02 min (IQR: 2.83-6.95) in those with ICE-guided TSP (p = .22). Mean fluoroscopy time was 0.2 min (IQR: 0.1-0.4) in patients with 3D-guided TSP compared to 1.2 min (IQR: 0.7-2.2) in those with ICE-guided TSP (p < .001). There were no complications related to TSP in both group. CONCLUSIONS: Three-dimensional mapping-guided TSP is as safe and effective as ICE-guided TSP without additional cost.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Pontuação de Propensão , Átrios do Coração , Punções , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fluoroscopia , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 34(8): 1690-1697, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37417961

RESUMO

INTRODUCTION: Transseptal puncture (TSP) to allow for large delivery sheath left atrial (LA) access remains a challenging aspect of LA appendage closure (LAAC) in patients with prior history of TSP, thick or lipomatous septum, atrial septal aneurysms, or other complex cardiac anatomies. This study investigates the use of the VersaCross large access (VLA) system (Baylis Medical/Boston Scientific) to improve procedural efficiency of LAAC compared to the standard needle workflow. METHODS AND RESULTS: Fifty LAAC procedures using WATCHMAN FLX between November 2021 and September 2022 were retrospectively analyzed comparing the VLA workflow (n = 25) to the standard needle workflow (n = 25). Study primary endpoint was time to procedural efficiency, and secondary endpoints included TSP time, acute LAAC success, fluoroscopy use, device recaptures, and periprocedural complications. Acute LAAC was successfully completed in all cases with no intraprocedural complications. TSP time was faster, but not significant, using the VLA workflow compared to the standard RF needle workflow (2.6 ± 1.1 min vs. 3.0 ± 1.8 min, p = 0.38). Time to WATCHMAN sheath in LA from TSP was 27% faster (1.5 ± 0.8 min vs. 2.1 ± 0.9 min; p = 0.03), and time to WATCHMAN release from TSP was 19% faster (10.5. ± 2.5 min vs. 13.0 ± 3.7 min; p = 0.01) with the VLA workflow. Overall procedure time was 15% faster (30.4 ± 5.1 min vs. 36.0 ± 6.6 min; p = 0.003) using VLA. Fluoroscopy time was 25% lower (4.0 ± 2.2 min vs. 5.5 ± 2.3 min; p = 0.003) and fluoroscopy dose was 60% lower (97.0 ± 91.7 mGy vs. 241.8 ± 240.6 mGy; p = 0.01) and more consistent [F-test, p ˂ 0.0001] using the VLA workflow compared to the needle workflow. CONCLUSION: The VLA system streamlines LAAC procedures, improving LAAC efficiency and reducing fluoroscopy use by allowing for de novo dilation of the septum for large-bore delivery sheaths, and reducing device exchanges and delivery sheath manipulation.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Cateterismo Cardíaco , Átrios do Coração , Resultado do Tratamento
12.
Artigo em Inglês | MEDLINE | ID: mdl-36626294

RESUMO

OBJECTIVE: The radiofrequency (RF) needle has been shown to improve transseptal puncture efficiency and safety compared to mechanical needles. This study aimed to investigate the use of VersaCross RF transseptal wire system (Baylis Medical) to improve procedural efficiency of left atrial appendage closure (LAAC) compared to the standard RF needle-based workflow. METHODS: Eighty-one LAAC procedures using WATCHMAN FLX were retrospectively analyzed comparing the standard RF needle-based workflow to a RF wire-based workflow. Study primary endpoint was time to WATCHMAN device release, and secondary endpoints were transseptal puncture time, LAAC success, fluoroscopy use, and procedural complications. RESULTS: Twenty-five cases using standard RF needle-based workflow were compared to 56 cases using the RF wire-based workflow. Baseline patient characteristics were similar between both groups. LAAC was successful in all patients with no differences in intraprocedural complication rates (p = 0.40). Transseptal puncture time was 1.3 min faster using the RF wire-based workflow compared to the standard RF needle-based workflow (6.5 ± 2.3  vs. 7.8 ± 2.3 min, p = 0.02). Overall, time to final WATCHMAN device release was 4.5 min faster with the RF wire-based workflow compared to the RF needle-based workflow (24.6 ± 5.6 vs. 29.1 ± 9.6 min, p = 0.01). Fluoroscopy time was 21% lower using the RF wire-based workflow (7.6 ± 2.8 vs. 9.6 ± 4.4 min; p = 0.05) and fluoroscopy dose was 67% lower (47.1 ± 35.3 vs. 144.9 ± 156.9 mGy, p = 0.04) and more consistent (F-test, p ˂ 0.0001). CONCLUSIONS: The RF wire-based workflow streamlines LAAC procedures, improving LAAC efficiency and safety by reducing fluoroscopy, device exchanges, and delivery sheath manipulation.

13.
Catheter Cardiovasc Interv ; 101(1): 227-230, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36413620

RESUMO

BACKGROUND: Left atrial appendage occlusion (LAAO) has emerged over the last two decades as an efficient and safe alternative to oral anticoagulation for stroke prevention. However, LAAO remains challenging due to the variety of anatomies and the multiple steps required to complete the procedure. AIMS: We report the first series of in-human experience of the new all-in-one VersaCross Connect system designed to access the left atrium in conjunction with the delivery sheath for deployment of the WATCHMAN FLX device. METHODS: We prospectively included the first nine consecutive cases of LAAO using the new VersaCross Connect system for WATCHMAN FLX device implantation at the Montreal Heart Institute and Vancouver General Hospital and collected procedural duration (defined as time from femoral access to closure) and time from transseptal puncture to device delivery. RESULTS: VersaCross Connect system use for WATCHMAN FLX implantation was successful in all patients. No procedural complication was reported. Mean procedural time was 31 ± 6.3 min with a fluoroscopy time of 6.7 ± 4.9 min. The mean delay between the transseptal puncture and device implantation was 12.2 ± 1.9 min. CONCLUSIONS: We showed that the VersaCross Connect system was safe and successfully used in all first nine cases. This new system helped improve the efficiency of the procedure.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Resultado do Tratamento , Átrios do Coração , Cateterismo Cardíaco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
14.
Catheter Cardiovasc Interv ; 102(7): 1331-1340, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37855202

RESUMO

BACKGROUND: The presented study investigates the application of bi-arterial 3D printed models to guide transseptal puncture (TSP) in left atrial appendage closure (LAAC). AIMS: The objectives are to (1) test the feasibility of 3D printing (3DP) for TSP guidance, (2) analyse the distribution of the optimal TSP locations, and (3) define a CT-derived 2D parameter suitable for predicting the optimal TSP locations. METHODS: Preprocedural planning included multiplanar CT reconstruction, 3D segmentation, and 3DP. TSP was preprocedurally simulated in vitro at six defined sites. Based on the position of the sheath, TSP sites were classified as optimal, suboptimal, or nonoptimal. The aim was to target the TSP in the recommended position during the procedure. Procedure progress was assessed post hoc by the operator. RESULTS: Of 68 screened patients, 60 patients in five centers (mean age of 74.68 ± 7.64 years, 71.66% males) were prospectively analyzed (3DP failed in one case, and seven patients did not finally undergo the procedure). In 55 patients (91.66%), TSP was performed in the optimal location as recommended by the 3DP. The optimal locations for TSP were postero-inferior in 45.3%, mid-inferior in 45.3%, and antero-inferior in 37.7%, with a mean number of optimal segments of 1.34 ± 0.51 per patient. When the optimal TSP location was achieved, the procedure was considered difficult in only two (3.6%) patients (but in both due to complicated LAA anatomy). Comparing anterior versus posterior TSP in 2D CCT, two parameters differed significantly: (1) the angle supplementary to the LAA ostium and the interatrial septum angle (160.83° ± 9.42° vs. 146.49° ± 8.67°; p = 0.001), and (2) the angle between the LAA ostium and the mitral annulus (95.02° ± 3.73° vs. 107.38° ± 6.76°; p < 0.001), both in the sagittal plane. CONCLUSIONS: In vitro TSP simulation accurately determined the optimal TSP locations for LAAC and facilitated the procedure. More than one-third of the optimal TSP sites were anterior.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Feminino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Resultado do Tratamento , Fibrilação Atrial/terapia , Fibrilação Atrial/cirurgia , Impressão Tridimensional , Tomografia Computadorizada por Raios X , Punções/métodos
15.
Catheter Cardiovasc Interv ; 102(2): 266-272, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37403549

RESUMO

Improper identification of the atrial septal defect margins during surgery and inadvertent suturing of the surgical patch to the Eustachian valve of the inferior vena cava (IVC) results in the diversion of inferior venacaval blood to the left atrium causing cyanosis. This complication has been dealt so far with surgery. We report the planning and implementation of a novel transcatheter rediversion of the IVC to the right atrium using a covered stent.


Assuntos
Cianose , Comunicação Interatrial , Veia Cava Inferior , Humanos , Feminino , Adulto , Veia Cava Inferior/cirurgia , Ecocardiografia , Cianose/diagnóstico por imagem , Cianose/etiologia , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Hipóxia , Complicações Pós-Operatórias , Resultado do Tratamento
16.
Europace ; 25(4): 1500-1502, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36892147

RESUMO

AIMS: Pulsed field ablation (PFA) for pulmonary vein isolation (PVI) combines the benefits of high procedural efficacy and safety. Transseptal puncture (TSP) to obtain left atrial (LA) access during PVI remains an important source of complications during LA procedures. For PFA procedures, TSP is generally performed using a standard transseptal sheath that is then exchanged over the wire for a dedicated PFA sheath, which might be a potential source for air embolism. We aimed to prospectively evaluate the feasibility and safety of a simplified workflow using the PFA sheath (Faradrive, Boston Scientific) directly for TSP. METHODS AND RESULTS: We prospectively enrolled 100 patients undergoing PVI using PFA at two centres. TSP was performed using the PFA sheath and a standard 98 cm transseptal needle under fluoroscopic guidance. TSP via the PFA sheath was successfully performed in all patients and no complications occurred. The median time from the first groin puncture to the completed LA access was 12 min (IQR 8-16 min). CONCLUSION: An over-the-needle TSP directly with the PFA sheath proved feasible and safe in our study. This simplified workflow has the potential to reduce the risk of air embolism, to shorten procedure time, and to reduce cost.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Embolia Aérea , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Embolia Aérea/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Punções/métodos , Resultado do Tratamento
17.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38011331

RESUMO

AIMS: This study was performed to compare the usability, efficiency, and safety of a modified angioplasty guidewire-assisted transseptal puncture (TSP) technique vs. the conventional approach in facilitating access into the left atrium during left atrial appendage occlusion (LAAO) procedures for the treatment of atrial fibrillation. METHODS AND RESULTS: The ADVANCE-LAAO trial (Angioplasty Guidewire-Assisted vs. Conventional Transseptal Puncture for Left Atrial Appendage Occlusion) was an investigator-initiated, prospective, multicentre, randomized controlled trial (NCT05125159). Patients with atrial fibrillation who underwent LAAO were prospectively enrolled from four centres and randomly assigned to an angioplasty guidewire-assisted TSP group (n = 131) or to a conventional Brockenbrough needle TSP group (n = 132). The primary endpoint was the one-time success rate of TSP. We also analysed the TSP procedure time, failure rate of the assigned TSP type, radiation dose, contrast dose, and procedural complications in both groups. All patients in the guidewire-assisted group underwent successful TSP, whereas five in the standard conventional group switched to the guidewire-assisted approach. The guidewire-assisted puncture improved the one-time success rate (92.4 vs. 77.3%, P = 0.001), shortened the TSP procedure time (109.2 ± 48.2 vs. 120.5 ± 57.6 s, P = 0.023), and tended to have a higher rate of good coaxial orientation of the sheath with the left atrial appendage during the LAAO procedure (66.4 vs. 54.5%, P = 0.059). No TSP-related complications occurred in the guidewire-assisted TSP group, whereas two complications occurred in the conventional TSP group. There was no significant difference in the failure rate of the assigned TSP type, the total procedure time, the total radiation dose, the rate of successful LAAO implantation, or the procedural complication rate between the two groups (all P > 0.05). CONCLUSION: This study confirmed that angioplasty guidewire-assisted puncture can effectively improve the success rate of TSP during LAAO procedures. This novel technique has high potential for application in interventional therapies requiring TSP.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Angioplastia , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Punções/métodos , Resultado do Tratamento
18.
Europace ; 25(3): 1126-1134, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36610064

RESUMO

AIMS: Transseptal puncture (TP) for left-sided catheter ablation procedures is routinely performed under fluoroscopic or echocardiographic guidance [transoesophageal echocardiography (TEE) or intracardiac echocardiography (ICE)], although three-dimensional (3D) mapping systems are readily available in most electrophysiology laboratories. Here, we sought to assess the feasibility and safety of a right atrial (RA) 3D map-guided TP. METHODS AND RESULTS: In 104 patients, 3D RA mapping was performed to identify the fossa ovalis (FO) using the protrusion technique. The radiofrequency transseptal needle was visualized and navigated to the desired potential FO-TP site. Thereafter, the interventionalist was unblinded to TEE and the potential FO-TP site was reassessed regarding its convenience and safety. After TP, the exact TP site was documented using a 17-segment-FO model. Reliable identification of the FO was feasible in 102 patients (98%). In these, 114 3D map-guided TP attempts were performed, of which 96 (84%) patients demonstrated a good position and 18 (16%) an adequate position after TEE unblinding. An out-of-FO or dangerous position did not occur. A successful 3D map-guided TP was performed in 110 attempts (97%). Four attempts (3%) with adequate positions were aborted in order to seek a more convenient TP site. The median time from RA mapping until the end of the TP process was 13 (12-17) min. No TP-related complications occurred. Ninety-eight TP sites (85.1%) were in the central portion or in the inner loop of the FO. CONCLUSION: A 3D map-guided TP is feasible and safe. It may assist to decrease radiation exposure and the need for TEE/ICE during left-sided catheter ablation procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Estudos de Viabilidade , Cateterismo Cardíaco/métodos , Átrios do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Punções , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Resultado do Tratamento
19.
J Cardiothorac Vasc Anesth ; 37(6): 988-999, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36870792

RESUMO

Transseptal puncture is an increasingly common procedure undertaken to gain access to the left side of the heart during structural heart disease interventions. Precision guidance during this procedure is paramount to ensure success and patient safety. As such, multimodality imaging, such as echocardiography, fluoroscopy, and fusion imaging, is routinely used to guide safe transseptal puncture. Despite the use of multimodal imaging, there is currently no uniform nomenclature of cardiac anatomy between the various imaging modes and proceduralists, and echocardiographers tend to use imaging modality-specific terminology when communicating among the various imaging modes. This variability in nomenclature among imaging modes stems from differing anatomic descriptions of cardiac anatomy. Given the required level of precision in performing transseptal puncture, a clearer understanding of the basis of cardiac anatomic nomenclature is required by both echocardiographers as well as proceduralists; enhanced understanding can help facilitate communication across specialties and possibly improve communication and safety. In this review, the authors highlight the variation in cardiac anatomy nomenclature among various imaging modes.


Assuntos
Septo Interatrial , Ablação por Cateter , Cardiopatias , Humanos , Cateterismo Cardíaco/métodos , Septo Interatrial/diagnóstico por imagem , Septo Interatrial/cirurgia , Ecocardiografia/métodos , Punções/métodos
20.
Cardiol Young ; 33(5): 754-759, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35673794

RESUMO

BACKGROUND: Electroanatomic mapping systems are increasingly used during ablations to decrease the need for fluoroscopy and therefore radiation exposure. For left-sided arrhythmias, transseptal puncture is a common procedure performed to gain access to the left side of the heart. We aimed to demonstrate the radiation exposure associated with transseptal puncture. METHODS: Data were retrospectively collected from the Catheter Ablation with Reduction or Elimination of Fluoroscopy registry. Patients with left-sided accessory pathway-mediated tachycardia, with a structurally normal heart, who had a transseptal puncture, and were under 22 years of age were included. Those with previous ablations, concurrent diagnostic or interventional catheterisation, and missing data for fluoroscopy use or procedural outcomes were excluded. Patients with a patent foramen ovale who did not have a transseptal puncture were selected as the control group using the same criteria. Procedural outcomes were compared between the two groups. RESULTS: There were 284 patients in the transseptal puncture group and 70 in the patent foramen ovale group. The transseptal puncture group had a significantly higher mean procedure time (158.8 versus 131.4 minutes, p = 0.002), rate of fluoroscopy use (38% versus 7%, p < 0.001), and mean fluoroscopy time (2.4 versus 0.6 minutes, p < 0.001). The acute success and complication rates were similar. CONCLUSIONS: Performing transseptal puncture remains a common reason to utilise fluoroscopy in the era of non-fluoroscopic ablation. Better tools are needed to make non-fluoroscopic transseptal puncture more feasible.


Assuntos
Ablação por Cateter , Forame Oval Patente , Exposição à Radiação , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Punções/métodos , Ablação por Cateter/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA