Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 561
Filtrar
Mais filtros

País/Região como assunto
Intervalo de ano de publicação
1.
Nano Lett ; 24(13): 3882-3889, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38527217

RESUMO

We develop analytical models of optical-field-driven electron tunneling from the edge and surface of free-standing two-dimensional (2D) materials. We discover a universal scaling between the tunneling current density (J) and the electric field near the barrier (F): In(J/|F|ß) ∝ 1/|F| with ß values of 3/2 and 1 for edge emission and vertical surface emission, respectively. At ultrahigh values of F, the current density exhibits an unexpected high-field saturation effect due to the reduced dimensionality of the 2D material, which is absent in the traditional bulk material. Our calculation reveals the dc bias as an efficient method for modulating the optical-field tunneling subcycle emission characteristics. Importantly, our model is in excellent agreement with a recent experiment on graphene. Our results offer a useful framework for understanding optical-field tunneling emission from 2D materials, which are helpful for the development of optoelectronics and emerging petahertz vacuum nanoelectronics.

2.
J Neurosci ; 43(16): 2950-2959, 2023 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-36922026

RESUMO

Numerosity, the set size of a group of items, helps guide human and animals' behavior and decisions. Numerosity perception is thought to be a precursor of symbolic numerical cognition. Previously, we uncovered neural populations selectively tuned to numerosities organized in a network of topographic maps in human association cortex. Here we investigate whether these numerosity maps are also involved in the processing of symbolic numbers, using 7T fMRI and a number-detection task. We recruited 7 participants (3 females) and found that the numerosity map at the temporal-occipital cortex (NTO) also responds to symbolic numbers. Furthermore, we found that numerosity-tuned neuronal populations at the NTO map in the left hemisphere are tuned to symbolic numbers. These results reveal different functions of the numerosity maps and support a link between numerosity representation and symbolic number processing in the ventral temporal-occipital cortex.SIGNIFICANCE STATEMENT Humans and other animals share an intuitive "number sense" to approximately represent numerosity. However, humans possess a unique ability to process number symbols (e.g., Arabic numbers). It has been argued that the human understanding of symbolic numbers is rooted in our ability to numerosity perception. Here we investigate whether numerosity-tuned neuronal populations organized at a network of topographic maps also respond to symbolic numbers. We find one of the maps at the temporal-occipital cortex is involved in symbolic numerical cognition and the neuronal populations are tuned to numbers. These results provide evidence for a link between nonsymbolic numerosity and symbolic number processing.


Assuntos
Mapeamento Encefálico , Cognição , Feminino , Humanos , Lobo Temporal , Lobo Occipital , Imageamento por Ressonância Magnética
3.
Neuroimage ; 286: 120511, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38184158

RESUMO

GABA+ and Glx (glutamate and glutamine) are widely studied metabolites, yet the commonly used magnetic resonance spectroscopy (MRS) techniques have significant limitations, including sensitivity to B0 and B1+-inhomogeneities, limited bandwidth of MEGA-pulses, high SAR which is accentuated at 7T. To address these limitations, we propose SLOW-EPSI method, employing a large 3D MRSI coverage and achieving a high resolution down to 0.26 ml. Simulation results demonstrate the robustness of SLOW-editing for both GABA+ and Glx against B0 and B1+-inhomogeneities within the range of [-0.3, +0.3] ppm and [40 %, 250 %], respectively. Two protocols, both utilizing a 70 mm thick FOV slab, were employed to target distinct brain regions in vivo, differentiated by their orientation: transverse and tilted. Protocol 1 (n = 11) encompassed 5 locations (cortical gray matter, white matter, frontal lobe, parietal lobe, and cingulate gyrus). Protocol 2 (n = 5) involved 9 locations (cortical gray matter, white matter, frontal lobe, occipital lobe, cingulate gyrus, caudate nucleus, hippocampus, putamen, and inferior thalamus). Quantitative analysis of GABA+ and Glx was conducted in a stepwise manner. First, B1+/B1--inhomogeneities were corrected using water reference data. Next, GABA+ and Glx values were calculated employing spectral fitting. Finally, the GABA+ level for each selected region was compared to the global Glx within the same subject, generating the GABA+/Glx_global ratio. Our findings from two protocols indicate that the GABA+/Glx_global level in cortical gray matter was approximately 16 % higher than in white matter. Elevated GABA+/Glx_global levels acquired with protocol 2 were observed in specific regions such as the caudate nucleus (0.118±0.067), putamen (0.108±0.023), thalamus (0.092±0.036), and occipital cortex (0.091±0.010), when compared to the cortical gray matter (0.079±0.012). Overall, our results highlight the effectiveness of SLOW-EPSI as a robust and efficient technique for accurate measurements of GABA+ and Glx at 7T. In contrast to previous SVS and 2D-MRSI based editing sequences with which only one or a limited number of brain regions can be measured simultaneously, the method presented here measures GABA+ and Glx from any brain area and any arbitrarily shaped volume that can be flexibly selected after the examination. Quantification of GABA+ and Glx across multiple brain regions through spectral fitting is achievable with a 9-minute acquisition. Additionally, acquisition times of 18-27 min (GABA+) and 9-18 min (Glx) are required to generate 3D maps, which are constructed using Gaussian fitting and peak integration.


Assuntos
Encéfalo , Substância Cinzenta , Humanos , Espectroscopia de Ressonância Magnética/métodos , Encéfalo/metabolismo , Substância Cinzenta/metabolismo , Ácido Glutâmico/metabolismo , Ácido gama-Aminobutírico/metabolismo , Imageamento por Ressonância Magnética/métodos
4.
Hum Brain Mapp ; 45(3): e26597, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38375948

RESUMO

Although functional magnetic resonance imaging (fMRI) is widely applied in the brain, fMRI of the spinal cord is more technically demanding. Proximity to the vertebral column and lungs results in strong spatial inhomogeneity and temporal fluctuations in B0 . Increasing field strength enables higher spatial resolution and improved sensitivity to blood oxygenation level-dependent (BOLD) signal, but amplifies the effects of B0 inhomogeneity. In this work, we present the first task fMRI in the spinal cord at 7 T. Further, we compare the performance of single-shot and multi-shot 2D echo-planar imaging (EPI) protocols, which differ in sensitivity to spatial and temporal B0 inhomogeneity. The cervical spinal cords of 11 healthy volunteers were scanned at 7 T using single-shot 2D EPI at 0.75 mm in-plane resolution and multi-shot 2D EPI at 0.75 and 0.6 mm in-plane resolutions. All protocols used 3 mm slice thickness. For each protocol, the BOLD response to 13 10-s noxious thermal stimuli applied to the right thumb was acquired in a 10-min fMRI run. Image quality, temporal signal to noise ratio (SNR), and BOLD activation (percent signal change and z-stat) at both individual- and group-level were evaluated between the protocols. Temporal SNR was highest in single-shot and multi-shot 0.75 mm protocols. In group-level analyses, activation clusters appeared in all protocols in the ipsilateral dorsal quadrant at the expected C6 neurological level. In individual-level analyses, activation clusters at the expected level were detected in some, but not all subjects and protocols. Single-shot 0.75 mm generally produced the highest mean z-statistic, while multi-shot 0.60 mm produced the best-localized activation clusters and the least geometric distortion. Larger than expected within-subject segmental variation of BOLD activation along the cord was observed. Group-level sensory task fMRI of the cervical spinal cord is feasible at 7 T with single-shot or multi-shot EPI. The best choice of protocol will likely depend on the relative importance of sensitivity to activation versus spatial localization of activation for a given experiment. PRACTITIONER POINTS: First stimulus task fMRI results in the spinal cord at 7 T. Single-shot 0.75 mm 2D EPI produced the highest mean z-statistic. Multi-shot 0.60 mm 2D EPI provided the best-localized activation and least distortion.


Assuntos
Medula Cervical , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Medula Cervical/diagnóstico por imagem , Imagem Ecoplanar/métodos , Medula Espinal/diagnóstico por imagem , Medula Espinal/patologia , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia
5.
Hum Brain Mapp ; 45(6): e26681, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38656060

RESUMO

Olfactory perception depends not only on olfactory inputs but also on semantic context. Although multi-voxel activity patterns of the piriform cortex, a part of the primary olfactory cortex, have been shown to represent odor perception, it remains unclear whether semantic contexts modulate odor representation in this region. Here, we investigated whether multi-voxel activity patterns in the piriform cortex change when semantic context modulates odor perception and, if so, whether the modulated areas communicate with brain regions involved in semantic and memory processing beyond the piriform cortex. We also explored regional differences within the piriform cortex, which are influenced by olfactory input and semantic context. We used 2 × 2 combinations of word labels and odorants that were perceived as congruent and measured piriform activity with a 1-mm isotropic resolution using 7T MRI. We found that identical odorants labeled with different words were perceived differently. This labeling effect was observed in multi-voxel activity patterns in the piriform cortex, as the searchlight decoding analysis distinguished identical odors with different labels for half of the examined stimulus pairs. Significant functional connectivity was observed between parts of the piriform cortex that were modulated by labels and regions associated with semantic and memory processing. While the piriform multi-voxel patterns evoked by different olfactory inputs were also distinguishable, the decoding accuracy was significant for only one stimulus pair, preventing definitive conclusions regarding the locational differences between areas influenced by word labels and olfactory inputs. These results suggest that multi-voxel patterns of piriform activity can be modulated by semantic context, possibly due to communication between the piriform cortex and the semantic and memory regions.


Assuntos
Mapeamento Encefálico , Imageamento por Ressonância Magnética , Odorantes , Percepção Olfatória , Córtex Piriforme , Semântica , Humanos , Masculino , Córtex Piriforme/fisiologia , Córtex Piriforme/diagnóstico por imagem , Percepção Olfatória/fisiologia , Feminino , Adulto , Adulto Jovem
6.
Hum Brain Mapp ; 45(5): e26667, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38544432

RESUMO

Emotion regulation is a process by which individuals modulate their emotional responses to cope with different environmental demands, for example, by reappraising the emotional situation. Here, we tested whether effective connectivity of a reappraisal-related neural network at rest is predictive of successfully regulating high- and low-intensity negative emotions in an emotion-regulation task. Task-based and resting-state functional magnetic resonance imaging (rs-fMRI) data of 28 participants were collected using ultra-high magnetic field strength at 7 Tesla during three scanning sessions. We used spectral dynamic causal modeling (spDCM) on the rs-fMRI data within brain regions modulated by emotion intensity. We found common connectivity patterns for both high- and low-intensity stimuli. Distinctive effective connectivity patterns in relation to low-intensity stimuli were found from frontal regions connecting to temporal regions. Reappraisal success for high-intensity stimuli was predicted by additional connections within the vlPFC and from temporal to frontal regions. Connectivity patterns at rest predicting reappraisal success were generally more pronounced for low-intensity stimuli, suggesting a greater role of stereotyped patterns, potentially reflecting preparedness, when reappraisal was relatively easy to implement. The opposite was true for high-intensity stimuli, which might require a more flexible recruitment of resources beyond what is reflected in resting state connectivity patterns. Resting-state effective connectivity emerged as a robust predictor for successful reappraisal, revealing both shared and distinct network dynamics for high- and low-intensity stimuli. These patterns signify specific preparatory states associated with heightened vigilance, attention, self-awareness, and goal-directed cognitive processing, particularly during reappraisal for mitigating the emotional impact of external stimuli. Our findings hold potential implications for understanding psychopathological alterations in brain connectivity related to affective disorders.


Assuntos
Mapeamento Encefálico , Emoções , Humanos , Emoções/fisiologia , Encéfalo/fisiologia , Transtornos do Humor , Processos Mentais , Imageamento por Ressonância Magnética/métodos
7.
Magn Reson Med ; 92(1): 4-14, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38441257

RESUMO

PURPOSE: To understand how macromolecular content varies in the human brain with age in a large cohort of healthy subjects. METHODS: In-vivo 1H-MR spectra were acquired using ultra-short TE STEAM at 7T in the posterior cingulate cortex. Macromolecular content was studied in 147 datasets from a cohort ranging in age from 19 to 89 y. Three fitting approaches were used to evaluate the macromolecular content: (1) a macromolecular resonances model developed for this study; (2) LCModel-simulated macromolecules; and (3) a combination of measured and LCModel-simulated macromolecules. The effect of age on the macromolecular content was investigated by considering age both as a continuous variable (i.e., linear regressions) and as a categorical variable (i.e., multiple comparisons among sub-groups obtained by stratifying data according to age by decade). RESULTS: While weak age-related effects were observed for macromolecular peaks at ˜0.9 (MM09), ˜1.2 (MM12), and ˜1.4 (MM14) ppm, moderate to strong effects were observed for peaks at ˜1.7 (MM17), and ˜2.0 (MM20) ppm. Significantly higher MM17 and MM20 content started from 30 to 40 y of age, while for MM09, MM12, and MM14, significantly higher content started from 60 to 70 y of age. CONCLUSIONS: Our findings provide insights into age-related differences in macromolecular contents and strengthen the necessity of using age-matched measured macromolecules during quantification.


Assuntos
Envelhecimento , Substâncias Macromoleculares , Humanos , Idoso , Pessoa de Meia-Idade , Adulto , Masculino , Feminino , Idoso de 80 Anos ou mais , Substâncias Macromoleculares/química , Adulto Jovem , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Giro do Cíngulo/diagnóstico por imagem , Giro do Cíngulo/química
8.
Magn Reson Med ; 91(4): 1576-1585, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38044841

RESUMO

PURPOSE: Ultra-high field (UHF) provides improved SNR which greatly benefits SNR starved imaging techniques such as perfusion imaging. However, transmit field (B1 + ) inhomogeneities commonly observed at UHF hinders the excitation uniformity. Here we show how replacing standard excitation pulses with parallel transmit pulses can improve efficiency of velocity selective labeling. METHODS: The standard tip-down and tip-up excitation pulses found in a velocity selective preparation module were replaced with tailored non-selective kT -points pulse solutions. Bloch simulations and experimental validation on a custom-built flow phantom and in vivo was performed to evaluate different pulse configurations in circularly polarized mode (CP-mode) and parallel transmit (pTx) mode. RESULTS: Tailored pTx pulses significantly improved velocity selective labeling fidelity and signal uniformity. The transverse magnetization normalized RMS error was reduced from 0.489 to 0.047 when compared to standard rectangular pulses played in CP-mode. Simulations showed that manipulation of time symmetry in the tailored pTx pulses is vital in minimizing residual magnetization. In addition, in vivo experiments achieved a 44% lower RF power output and a shorter pulse duration when compared to using adiabatic pulses in CP-mode. CONCLUSION: Using tailored pTx pulses for excitation within a velocity selective labeling preparation mitigated transmit field artifacts and improved SNR and contrast fidelity. The improvement in labeling efficiency highlights the potential of using pTx to improve robustness and accessibility of flow-based sequences such as velocity selective spin labeling at ultra-high field.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas , Artefatos , Algoritmos
9.
Magn Reson Med ; 91(3): 1268-1280, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38009927

RESUMO

PURPOSE: The aim of this work is to evaluate a new eight-channel transceiver (TxRx) coaxial dipole array for imaging of the human head at 9.4T developed to improve specific absorption rate (SAR) performance, and provide for a more compact and robust alternative to the state-of-the art dipole arrays. METHODS: First, the geometry of a single coaxial element was optimized to minimize peak SAR and sensitivity to the load variation. Next, a multi-tissue voxel model was used to numerically simulate a TxRx array coil that consisted of eight coaxial dipoles with the optimal configuration. Finally, we compared the developed array to other human head dipole arrays. Results of numerical simulations were verified on a bench and in the scanner including in vivo measurements on a healthy volunteer. RESULTS: The developed eight-element coaxial dipole TxRx array coil showed up to 1.1times higher SAR-efficiency than a similar in geometry folded-end and fractionated dipole array while maintaining whole brain coverage and low sensitivity of the resonance frequency to variation in the head size. CONCLUSION: As a proof of concept, we developed and constructed a prototype of a 9.4T (400 MHz) human head array consisting of eight TxRx coaxial dipoles. The developed array improved SAR-efficiency and provided for a more compact and robust alternative to the folded-end dipole design. To the best of our knowledge, this is the first example of using coaxial dipoles for human head MRI at ultra-high field.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas , Desenho de Equipamento , Cabeça/diagnóstico por imagem
10.
Magn Reson Med ; 91(2): 513-529, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37705412

RESUMO

PURPOSE: To increase the RF coil performance and RF management for body imaging at 10.5 T by validating and evaluating a high-density 16-channel transceiver array, implementing virtual observation points (VOPs), and demonstrating specific absorption rate (SAR) constrained imaging in vivo. METHODS: The inaccuracy of the electromagnetic model of the array was quantified based on B1 + and SAR data. Inter-subject variability was estimated using a new approach based on the relative SAR deviation of different RF shims between human body models. The pTx performance of the 16-channel array was assessed in simulation by comparison to a previously demonstrated 10-channel array. In vivo imaging of the prostate was performed demonstrating SAR-constrained static RF shimming and acquisition modes optimized for refocused echoes (AMORE). RESULTS: The model inaccuracy of 29% and the inter-subject variability of 85% resulted in a total safety factor of 1.91 for pelvis studies. For renal and cardiac imaging, inter-subject variabilities of 121% and 141% lead to total safety factors of 2.25 and 2.45, respectively. The shorter wavelength at 10.5 T supported the increased element density of the 16-channel array which in turn outperformed the 10-channel version for all investigated metrics. Peak 10 g local SAR reduction of more than 25% without a loss of image quality was achieved in vivo, allowing a theoretical improvement in measurement efficiency of up to 66%. CONCLUSIONS: By validating and characterizing a 16-channel dipole transceiver array, this work demonstrates, for the first time, a VOP-enabled RF coil for human torso imaging enabling increased pTx performance at 10.5 T.


Assuntos
Imageamento por Ressonância Magnética , Próstata , Masculino , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Desenho de Equipamento , Simulação por Computador , Ondas de Rádio
11.
Magn Reson Med ; 92(1): 43-56, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38303151

RESUMO

PURPOSE: To introduce universal modes by applying the universal pulse concept to time-interleaved acquisition of modes (TIAMO), thereby achieving calibration-free B 1 + $$ {B}_1^{+} $$ inhomogeneity mitigation for body imaging at ultra-high fields. METHODS: Two databases of different RF arrays were used to demonstrate the feasibility of universal modes. The first comprised 31 cardiac in vivo data sets acquired at 7T while the second consisted of 6 simulated 10.5T pelvic data sets. Subject-specific solutions and universal modes were computed and subsequently evaluated alongside predefined default modes. For the cardiac database, subdivision into subpopulations was investigated. The optimization was performed using least-squares (LS) TIAMO and acquisition modes optimized for refocused echoes (AMORE). Finally, universal modes based on simulated pelvis data were applied in vivo at 10.5T. RESULTS: In all studied cases, the universal modes yield improvements over the predefined default modes of up to 51% (cardiac) and 30% (pelvic) in terms of median excitation error when using two modes. The subpopulation-specific cardiac solutions revealed a further improvement of universal modes at the expense of increased errors when applied outside the appropriate subpopulation. Direct application of simulation-based universal modes in vivo resulted in up to a 14% reduction in excitation error compared to default modes and up to a 34% reduction in peak 10 g local specific absorption rate (SAR) compared to subject-specific solutions. CONCLUSIONS: Universal modes are feasible for calibration-free B 1 + $$ {B}_1^{+} $$ inhomogeneity mitigation at ultra-high fields. In addition, simulation-based solutions can be applied directly in vivo, eliminating the need for large in vivo databases.


Assuntos
Algoritmos , Coração , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Pelve , Humanos , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Pelve/diagnóstico por imagem , Calibragem , Masculino , Adulto , Simulação por Computador , Imagens de Fantasmas , Feminino , Análise dos Mínimos Quadrados , Bases de Dados Factuais
12.
Magn Reson Med ; 2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-39054786

RESUMO

PURPOSE: T 2 $$ {}_2 $$ -weighted turbo-spin-echo (TSE) sequences are a fundamental technique in brain imaging but suffer from field inhomogeneities at ultra-high fields. Several methods have been proposed to mitigate the problem, but were limited so far to nonselective three-dimensional (3D) measurements, making short acquisitions difficult to achieve when targeting very high resolution images, or needed additional calibration procedures, thus complicating their application. METHODS: Slab-selective excitation pulses were designed for flexible placement utilizing the concept of k T $$ {}_T $$ -spokes. Phase-coherent refocusing universal pulses were subsequently optimized with the Gradient Ascent Pulse Engineering algorithm and tested in vivo for improved signal homogeneity. RESULTS: Implemented within a 3D variable flip angle TSE sequence, these pulses led to a signal-to-noise ratio (SNR) improvement ranging from 10% to 30% compared to a two-dimensional (2D) T2w TSE sequence employing B 1 + $$ {\mathrm{B}}_1^{+} $$ -shimmed pulses. B 1 + $$ {\mathrm{B}}_1^{+} $$ field inhomogeneities could be mitigated and artifacts from B 0 $$ {\mathrm{B}}_0 $$ deviations reduced. The concept of universal pulses was successfully applied. CONCLUSION: We present a pulse design method which provides a set of calibration-free universal pulses (UPs) for slab-selective excitation and phase-coherent refocusing in slab-selective TSE sequences.

13.
Magn Reson Med ; 92(2): 605-617, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38440807

RESUMO

PURPOSE: Directly imaging the function of cerebral perforating arteries could provide valuable insight into the pathology of cerebral small vessel diseases (cSVD). Arterial pulsatility has been identified as a useful biomarker for assessing vascular dysfunction. In this study, we investigate the feasibility and reliability of using dual velocity encoding (VENC) phase-contrast MRI (PC-MRI) to measure the pulsatility of cerebral perforating arteries at 7 T. METHODS: Twenty participants, including 12 young volunteers and 8 elder adults, underwent high-resolution 2D PC-MRI scans with VENCs of 20 cm/s and 40 cm/s at 7T. The sensitivity of perforator detection and the reliability of pulsatility measurement of cerebral perforating arteries using dual-VENC PC-MRI were evaluated by comparison with the single-VENC data. The effects of temporal resolution in the PC-MRI acquisition and aging on the pulsatility measurements were investigated. RESULTS: Compared to the single VENCs, dual-VENC PC-MRI provided improved sensitivity of perforator detection and more reliable pulsatility measurements. Temporal resolution impacted the pulsatility measurements, as decreasing temporal resolution led to an underestimation of pulsatility. Elderly adults had elevated pulsatility in cerebral perforating arteries compared to young adults, but there was no difference in the number of detected perforators between the two age groups. CONCLUSION: Dual-VENC PC-MRI is a reliable imaging method for the assessment of pulsatility of cerebral perforating arteries, which could be useful as a potential imaging biomarker of aging and cSVD.


Assuntos
Artérias Cerebrais , Imageamento por Ressonância Magnética , Fluxo Pulsátil , Humanos , Feminino , Masculino , Adulto , Idoso , Reprodutibilidade dos Testes , Artérias Cerebrais/diagnóstico por imagem , Artérias Cerebrais/fisiologia , Fluxo Pulsátil/fisiologia , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Adulto Jovem , Doenças de Pequenos Vasos Cerebrais/diagnóstico por imagem , Circulação Cerebrovascular/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Angiografia por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos
14.
Magn Reson Med ; 92(3): 1277-1289, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38469893

RESUMO

PURPOSE: Ultrahigh field (≥7 T) MRI is at the cutting edge of medical imaging, enabling enhanced spatial and spectral resolution as well as enhanced susceptibility contrast. However, transmit ( B 1 + $$ {\mathrm{B}}_1^{+} $$ ) field inhomogeneity due to standing wave effects caused by the shortened RF wavelengths at 7 T is still a challenge to overcome. Novel hardware methods such as dielectric pads have been shown to improve the B 1 + $$ {\mathrm{B}}_1^{+} $$ field inhomogeneity but are currently limited in their corrective effect by the range of high-permittivity materials available and have a fixed shelf life. In this work, an optimized metasurface design is presented that demonstrates in vivo enhancement of the B 1 + $$ {\mathrm{B}}_1^{+} $$ field. METHODS: A prototype metasurface was optimized by an empirical capacitor sweep and by varying the period size. Phantom temperature experiments were performed to evaluate potential metasurface heating effects during scanning. Lastly, in vivo gradient echo images and B 1 + $$ {\mathrm{B}}_1^{+} $$ maps were acquired on five healthy subjects on a 7 T system. Dielectric pads were also used as a comparison throughout the work as a standard comparison. RESULTS: The metasurfaces presented here enhanced the average relative SNR of the gradient echo images by a factor of 2.26 compared to the dielectric pads factor of 1.61. Average B 1 + $$ {\mathrm{B}}_1^{+} $$ values reflected a similar enhancement of 27.6% with the metasurfaces present versus 8.9% with the dielectric pads. CONCLUSION: The results demonstrate that metasurfaces provide superior performance to dielectric padding as shown by B 1 + $$ {\mathrm{B}}_1^{+} $$ maps reflecting their direct effects and resulting enhancements in image SNR at 7 T.


Assuntos
Desenho de Equipamento , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Imageamento por Ressonância Magnética/instrumentação , Humanos , Perna (Membro)/diagnóstico por imagem , Adulto , Aumento da Imagem/métodos , Feminino , Masculino , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Razão Sinal-Ruído
15.
Magn Reson Med ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38888143

RESUMO

PURPOSE: To investigate the impact of reduced k-space sampling on B 1 + $$ {\mathrm{B}}_1^{+} $$ mapping and the resulting impact on phase shimming and dynamic/universal parallel transmit (pTx) RF pulse design. METHODS: Channel-wise 3D B 1 + $$ {\mathrm{B}}_1^{+} $$ maps were measured at 7 T in 35 and 23 healthy subjects for the heart and prostate region, respectively. With these B 1 + $$ {\mathrm{B}}_1^{+} $$ maps, universal phase shims optimizing homogeneity and B 1 + $$ {\mathrm{B}}_1^{+} $$ efficiency were designed for heart and prostate imaging. In addition, universal 4kT-point pulses were designed for the heart. Subsequently, individual phase shims and individual 4kT-pulses were designed based on B 1 + $$ {\mathrm{B}}_1^{+} $$ maps with different acceleration factors and tested on the original maps. The performance of the pulses was compared by evaluating their coefficients of variation (CoV), B 1 + $$ {\mathrm{B}}_1^{+} $$ efficiencies and specific energy doses (SED). Furthermore, validation measurements were carried out for one heart and one prostate subject. RESULTS: For both organs, the universal phase shims showed significantly higher B 1 + $$ {\mathrm{B}}_1^{+} $$ efficiencies and lower CoVs compared to the vendor provided default shim, but could still be improved with individual phase shims based on accelerated B 1 + $$ {\mathrm{B}}_1^{+} $$ maps (acquisition time = 30 s). In the heart, the universal 4kT-pulse achieved significantly lower CoVs than tailored phase shims. Tailored 4kT-pulses based on accelerated B 1 + $$ {\mathrm{B}}_1^{+} $$ maps resulted in even further reduced CoVs or a 2.5-fold reduction in SED at the same CoVs as the universal 4kT-pulse. CONCLUSION: Accelerated B 1 + $$ {\mathrm{B}}_1^{+} $$ maps can be used for the design of tailored pTx pulses for prostate and cardiac imaging at 7 T, which further improve homogeneity, B 1 + $$ {\mathrm{B}}_1^{+} $$ efficiency, or SED compared to universal pulses.

16.
Magn Reson Med ; 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38988040

RESUMO

PURPOSE: To explore the high signal-to-noise ratio (SNR) efficiency of interleaved multishot 3D-EPI with standard image reconstruction for fast and robust high-resolution whole-brain quantitative susceptibility (QSM) and R 2 ∗ $$ {R}_2^{\ast } $$ mapping at 7 and 3T. METHODS: Single- and multi-TE segmented 3D-EPI is combined with conventional CAIPIRINHA undersampling for up to 72-fold effective gradient echo (GRE) imaging acceleration. Across multiple averages, scan parameters are varied (e.g., dual-polarity frequency-encoding) to additionally correct for B 0 $$ {\mathrm{B}}_0 $$ -induced artifacts, geometric distortions and motion retrospectively. A comparison to established GRE protocols is made. Resolutions range from 1.4 mm isotropic (1 multi-TE average in 36 s) up to 0.4 mm isotropic (2 single-TE averages in approximately 6 min) with whole-head coverage. RESULTS: Only 1-4 averages are needed for sufficient SNR with 3D-EPI, depending on resolution and field strength. Fast scanning and small voxels together with retrospective corrections result in substantially reduced image artifacts, which improves susceptibility and R 2 ∗ $$ {R}_2^{\ast } $$ mapping. Additionally, much finer details are obtained in susceptibility-weighted image projections through significantly reduced partial voluming. CONCLUSION: Using interleaved multishot 3D-EPI, single-TE and multi-TE data can readily be acquired 10 times faster than with conventional, accelerated GRE imaging. Even 0.4 mm isotropic whole-head QSM within 6 min becomes feasible at 7T. At 3T, motion-robust 0.8 mm isotropic whole-brain QSM and R 2 ∗ $$ {R}_2^{\ast } $$ mapping with no apparent distortion in less than 7 min becomes clinically feasible. Stronger gradient systems may allow for even higher effective acceleration rates through larger EPI factors while maintaining optimal contrast.

17.
NMR Biomed ; 37(6): e5118, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38342102

RESUMO

Parallel imaging is one of the key MRI technologies that allow reduction of image acquisition time. However, the parallel imaging reconstruction commonly leads to a signal-to-noise ratio (SNR) drop evaluated using a so-called geometrical factor (g-factor). The g-factor is minimized by increasing the number of array elements and their spatial diversity. At the same time, increasing the element count requires a decrease in their size. This may lead to insufficient coil loading, an increase in the relative noise contribution from the RF coil itself, and hence SNR reduction. Previously, instead of increasing the channel number, we introduced the concept of electronically switchable time-varying sensitivities, which was shown to improve parallel imaging performance. In this approach, each reconfigurable receive element supports two spatially distinct sensitivity profiles. In this work, we developed and evaluated a novel eight-element human head receive-only reconfigurable coaxial dipole array for human head imaging at 9.4 T. In contrast to the previously reported reconfigurable dipole array, the new design does not include direct current (DC) control wires connected directly to the dipoles. The coaxial cable itself is used to deliver DC voltage to the PIN diodes located at the ends of the antennas. Thus, the novel reconfigurable coaxial dipole design opens a way to scale the dynamic parallel imaging up to a realistic number of channels, that is, 32 and above. The novel array was optimized and tested experimentally, including in vivo studies. It was found that dynamic sensitivity switching provided an 8% lower mean and 33% lower maximum g-factor (for Ry × Rz = 2 × 2 acceleration) compared with conventional static sensitivities.


Assuntos
Imageamento por Ressonância Magnética , Razão Sinal-Ruído , Imageamento por Ressonância Magnética/instrumentação , Humanos , Imagens de Fantasmas , Desenho de Equipamento , Encéfalo/diagnóstico por imagem
18.
Int J Neuropsychopharmacol ; 27(6)2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38833581

RESUMO

BACKGROUND: The NMDA antagonist S-ketamine is gaining increasing use as a rapid-acting antidepressant, although its exact mechanisms of action are still unknown. In this study, we investigated ketamine in respect to its properties toward central noradrenergic mechanisms and how they influence alertness behavior. METHODS: We investigated the influence of S-ketamine on the locus coeruleus (LC) brain network in a placebo-controlled, cross-over, 7T functional, pharmacological MRI study in 35 healthy male participants (25.1 ± 4.2 years) in conjunction with the attention network task to measure LC-related alertness behavioral changes. RESULTS: We could show that acute disruption of the LC alertness network to the thalamus by ketamine is related to a behavioral alertness reduction. CONCLUSION: The results shed new light on the neural correlates of ketamine beyond the glutamatergic system and underpin a new concept of how it may unfold its antidepressant effects.


Assuntos
Atenção , Estudos Cross-Over , Ketamina , Locus Cerúleo , Imageamento por Ressonância Magnética , Humanos , Ketamina/farmacologia , Ketamina/administração & dosagem , Locus Cerúleo/efeitos dos fármacos , Locus Cerúleo/diagnóstico por imagem , Locus Cerúleo/fisiologia , Masculino , Adulto , Adulto Jovem , Atenção/efeitos dos fármacos , Atenção/fisiologia , Antagonistas de Aminoácidos Excitatórios/farmacologia , Antagonistas de Aminoácidos Excitatórios/administração & dosagem , Método Duplo-Cego , Antidepressivos/farmacologia , Antidepressivos/administração & dosagem
19.
J Magn Reson Imaging ; 59(3): 941-951, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37276054

RESUMO

BACKGROUND: Paramagnetic rim lesions (PRLs) are associated with chronic inflammation in multiple sclerosis (MS). 7-Tesla (7T) magnetic resonance imaging (MRI) can evaluate the integrity of the blood-brain barrier (BBB) in addition to the tissue myelination status and cell loss. PURPOSE: To use MRI metrics to investigate underlying physiology and clinical importance of PRLs. STUDY TYPE: Prospective. SUBJECTS: Thirty-six participants (mean-age 47, 23 females, 13 males) of mixed MS subtypes. FIELD STRENGTH/SEQUENCE: 7T, MP2RAGE, MULTI-ECHO 3D-GRE, FLAIR. ASSESSMENT: Lesion heterogeneity; longitudinal changes in lesion counts; comparison of T1, R2*, and χ; association between baseline lesion types and disease progression (2-3 annual MRI visits with additional years of annual clinical follow-up). STATISTICAL TESTS: Two-sample t-test, Wilcoxon Rank-Sum test, Pearson's chi-square test, two-group comparison with linear-mixed-effect model, mixed-effect ANOVA, logistic regression. P-values <0.05 were considered significant. RESULTS: A total of 58.3% of participants had at least one PRL at baseline. Higher male proportion in PRL+ group was found. Average change in PRL count was 0.20 (SD = 2.82) for PRLs and 0.00 (SD = 0.82) for mottled lesions. Mean and median pre-/post-contrast T1 were longer in PRL+ than in PRL-. No differences in mean χ were seen for lesions grouped by PRL (P = 0.310, pre-contrast; 0.086, post-contrast) or PRL/M presence (P = 0.234, pre-contrast; 0.163, post-contrast). Median χ were less negative in PRL+ and PRL/M+ than in PRL- and PRL/M-. Mean and median pre-/post-contrast R2* were slower in PRL+ compared to PRL-. Mean and median pre-/post-contrast R2* were slower in PRL/M+ than in PRL/M-. PRL presence at baseline was associated with confirmed EDSS Plus progression (OR 3.75 [1.22-7.59]) and PRL/M+ at baseline with confirmed EDSS Plus progression (OR 3.63 [1.14-7.43]). DATA CONCLUSION: Evidence of BBB breakdown in PRLs was not seen. Quantitative metrics confirmed prior results suggesting greater demyelination, cell loss, and possibly disruption of tissue anisotropy in PRLs. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Assuntos
Esclerose Múltipla , Feminino , Humanos , Masculino , Esclerose Múltipla/patologia , Barreira Hematoencefálica/patologia , Encéfalo/patologia , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos
20.
J Magn Reson Imaging ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38587279

RESUMO

BACKGROUND: The choroid plexus (ChP), a densely vascularized structure, has drawn increasing attention for its involvement in brain homeostasis and waste clearance. While the volumetric changes have been explored in many imaging studies, few studies have investigated the vascular degeneration associated with aging in the ChP. PURPOSE: To investigate the sub-structural characteristics of the ChP, particularly the vascular compartment using high-resolution 7T imaging enhanced with Ferumoxytol, an ultrasmall super-paramagnetic iron oxide, which greatly increase the susceptibility contrast for vessels. STUDY TYPE: Prospective. SUBJECTS: Forty-nine subjects without neurological disorders (age: 21-80 years; 42 ± 17 years; 20 females). FIELD STRENGTH/SEQUENCE: 7-T with 2D and 3D T2* GRE, 3D MPRAGE T1, 2D TSE T2, and 2D FLAIR. ASSESSMENT: The vascular and stromal compartments of the ChP were segmented using K-means clustering on post-contrast 2D GRE images. Visual and qualitative assessment of ChP vascular characteristics were conducted independently by three observers. Vascular density (Volvessel/VolChP ratio) and susceptibility change (Δχ) induced by Ferumoxytol were analyzed on 3D GRE-derived susceptibility-weighted imaging and quantitative susceptibility mapping, respectively. STATISTICAL TESTS: Independent t-test, Mann-Whitney U test, and Chi-square test were utilized for group comparisons. The relationship between age and ChP's vascular alterations was examined using Pearson's correlation. Intra-class coefficient was calculated for inter-observer agreement. A P value <0.05 was considered statistically significant. RESULTS: 2D GRE images demonstrated superior contrast and accurate delineation of ChP substructures (ICC = 0.86). Older subjects exhibited a significantly smaller vascular density (16.5 ± 4.34%) and lower Δχ (22.10 ± 12.82 ppb) compared to younger subjects (24.85 ± 6.84% and 34.64 ± 12.69 ppb). Vascular density and mean Δχ within the ChP negatively correlated with age (r = -0.48, and r = -0.45). DATA CONCLUSION: Ferumoxytol-enhanced 7T images can demonstrate ChP alterations in elderly with decreased vascular density and expansion of nonvascular compartment. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA