Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Scand J Med Sci Sports ; 34(6): e14679, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38898554

RESUMO

PURPOSE: The Achilles tendon consists of three subtendons with the ability to slide relative to each other. As optimal intratendinous sliding is thought to reduce the overall stress in the tendon, alterations in sliding behavior could potentially play a role in the development of Achilles tendinopathy. The aims of this study were to investigate the difference in intratendinous sliding within the Achilles tendon during isometric contractions between asymptomatic controls and patients with Achilles tendinopathy and the effect of changing the horizontal foot position on intratendinous sliding in both groups. METHODS: Twenty-nine participants (13 Achilles tendinopathy and 16 controls) performed isometric plantarflexion contractions at 60% of their maximal voluntary contraction (MVC), in toes-neutral, and at 30% MVC in toes-neutral, toes-in, and toes-out positions during which ultrasound images were recorded. Intratendinous sliding was estimated as the superficial-to-middle and middle-to-deep relative displacement. RESULTS: Patients with Achilles tendinopathy present lower intratendinous sliding than asymptomatic controls. Regarding the horizontal foot position in both groups, the toes-out foot position resulted in increased sliding compared with both toes-neutral and toes-out foot position. CONCLUSION: We provided evidence that patients with Achilles tendinopathy show lower intratendinous sliding than asymptomatic controls. Since intratendinous sliding is a physiological feature of the Achilles tendon, the external foot position holds promise to increase sliding in patients with Achilles tendinopathy and promote healthy tendon behavior. Future research should investigate if implementing this external foot position in rehabilitation programs stimulates sliding within the Achilles tendon and improves clinical outcome.


Assuntos
Tendão do Calcâneo , , Contração Isométrica , Tendinopatia , Ultrassonografia , Humanos , Tendão do Calcâneo/diagnóstico por imagem , Tendão do Calcâneo/lesões , Tendão do Calcâneo/fisiopatologia , Tendinopatia/fisiopatologia , Tendinopatia/reabilitação , Masculino , Adulto , Feminino , Estudos de Casos e Controles , Pé/fisiopatologia , Pessoa de Meia-Idade , Postura/fisiologia , Adulto Jovem
2.
Eur J Appl Physiol ; 124(2): 633-647, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37950761

RESUMO

PURPOSE: The aim of this study was to investigate internal Achilles tendon (AT) displacement, AT shear wave velocity (SWV), and triceps surae (TS) muscle shear modulus in athletes. METHODS: Internal AT displacement was assessed using ultrasound during isometric contraction. Shear wave elastography was used to assess AT SWV (m × s-1) at rest and TS muscle shear modulus (kPa) during passive ankle dorsiflexion. RESULTS: A total of 131 athletes participated in this study. Athletes who had not exercised within two days had greater AT non-uniformity and mean anterior tendon displacement, and lower SWV at the proximal AT measurement site (mean difference [95% CI]: 1.8 mm [0.6-2.9], p = 0.003; 1.6 mm [0.2-2.9], p = 0.021; - 0.9 m × s-1 [- 1.6 to - 0.2], p = 0.014, respectively). Male basketball players had a lower mean AT displacement compared to gymnasts (- 3.7 mm [- 6.9 to - 0.5], p = 0.042), with the difference localised in the anterior half of the tendon (- 5.1 mm [- 9.0 to - 1.1], p = 0.022). Male gymnasts had a smaller absolute difference in medial gastrocnemius-minus-soleus shear modulus than basketball players (59.6 kPa [29.0-90.2], p < 0.001) and track and field athletes (52.7 kPa [19.2-86.3], p = 0.004). Intraclass correlation coefficients of measurements ranged from 0.720 to 0.937 for internal AT displacement, from 0.696 to 0.936 for AT SWE, and from 0.570 to 0.890 for TS muscles. CONCLUSION: This study provides a reliability assessment of muscle and tendon SWV. The relative differences in passive TS muscle shear modulus suggest sport-specific adaptation. Importantly, in healthy individuals, lower AT displacement after exercise may reflect the time required for tendon recovery.


Assuntos
Tendão do Calcâneo , Técnicas de Imagem por Elasticidade , Humanos , Masculino , Tendão do Calcâneo/diagnóstico por imagem , Tendão do Calcâneo/fisiologia , Reprodutibilidade dos Testes , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Perna (Membro) , Atletas
3.
Scand J Med Sci Sports ; 31(5): 1069-1077, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33464638

RESUMO

The purpose of this study was investigate tendon displacement patterns in non-surgically treated patients 14 months after acute Achilles tendon rupture (ATR) and to classify patients into groups based on their Achilles tendon (AT) displacement patterns. Twenty patients were tested. Sagittal images of AT were acquired using B-mode ultrasonography during ramp contractions at a torque level corresponding to 30% of the maximal isometric plantarflexion torque of the uninjured limb. A speckle tracking algorithm was used to track proximal-distal movement of the tendon tissue at 6 antero-posterior locations. Two-way repeated measures ANOVA for peak tendon displacement was performed. K-means clustering was used to classify patients according to AT displacement patterns. The difference in peak relative displacement across locations was larger in the uninjured (1.29 ± 0.87 mm) than the injured limb (0.69 ± 0.68 mm), with a mean difference (95% CI) of 0.60 mm (0.14-1.05 mm, P < .001) between limbs. For the uninjured limb, cluster analysis formed 3 groups, while 2 groups were formed for the injured limb. The three distinct patterns of AT displacement during isometric plantarflexion in the uninjured limb may arise from subject-specific anatomical variations of AT sub-tendons, while the two patterns in the injured limb may reflect differential recovery after ATR with non-surgical treatment. Subject-specific tendon characteristics are a vital determinant of stress distribution across the tendon. Changes in stress distribution may lead to variation in the location and magnitude of peak displacement within the free AT. Quantifying internal tendon displacement patterns after ATR provides new insights into AT recovery.


Assuntos
Tendão do Calcâneo/lesões , Tendão do Calcâneo/fisiopatologia , Contração Isométrica , Ruptura/fisiopatologia , Tendão do Calcâneo/diagnóstico por imagem , Adulto , Algoritmos , Fenômenos Biomecânicos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Ruptura/diagnóstico por imagem , Ruptura/terapia , Torque , Ultrassonografia
4.
Can J Physiol Pharmacol ; 95(9): 985-992, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28301729

RESUMO

The objective of this study was to study the functional changes of the left atrium after radiofrequency ablation treatment for atrial fibrillation and the therapeutic effect of atorvastatin. Fifty-eight patients undergoing radiofrequency ablation for atrial fibrillation were randomly divided into non-atorvastatin group and atorvastatin group. Patients in the atorvastatin group were treated with atorvastatin 20 mg p.o. per night in addition to the conventional treatment of atrial fibrillation; patients in the non-atorvastatin group received conventional treatment of atrial fibrillation only. Echocardiography was performed before radiofrequency ablation operation and 1 week, 2 weeks, 3 weeks, and 4 weeks after operation. Two-dimensional ultrasound speckle tracking imaging system was used to measure the structural indexes of the left atrium. Results indicated that there was no significant change for indexes representing the structural status of the left atrium within a month after radiofrequency ablation (P > 0.05); however, there were significant changes for indexes representing the functional status of the left atrium. There were also significant changes in indexes reflecting left atrial strain status: the S and SRs of atorvastatin group were higher than those of non-atorvastatin group (P < 0.05). In summary, atorvastatin could improve left atrial function and shorten the duration of atrial stunning after radiofrequency ablation of atrial fibrillation.


Assuntos
Atorvastatina/farmacologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Átrios do Coração/efeitos dos fármacos , Átrios do Coração/fisiopatologia , Miocárdio Atordoado/tratamento farmacológico , Miocárdio Atordoado/etiologia , Adulto , Idoso , Atorvastatina/uso terapêutico , Fibrilação Atrial/complicações , Feminino , Átrios do Coração/patologia , Átrios do Coração/efeitos da radiação , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio Atordoado/complicações , Miocárdio Atordoado/fisiopatologia , Volume Sistólico/efeitos dos fármacos , Volume Sistólico/efeitos da radiação , Sístole/efeitos dos fármacos
5.
Ultrasound Med Biol ; 49(12): 2548-2556, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37741741

RESUMO

OBJECTIVE: Restricted tendon gliding is commonly observed in patients after finger flexor tendon (FFT) repair. The study described here was aimed at quantifying the amount of FFT gliding to evaluate the recovery of post-operative tendons using a 2-D radiofrequency (RF)-based ultrasound speckle tracking algorithm (UST). METHODS: Ex vivo uniaxial tensile testing of porcine flexor tendons and in vivo isometric testing of human FFT were implemented to verify the efficacy of UST beforehand. The verified UST was then applied to the patients after FFT repair to compare tendon gliding between affected and healthy sides and to investigate its correlation with the joint range of motion (ROM). RESULTS: Excellent validity was confirmed with the average R2 value of 0.98, mean absolute error of 0.15 ± 0.08 mm and mean absolute percentage error of 5.19 ± 2.43% between results from UST and ex vivo testing. The test-retest reliability was verified with good agreement of ICC (0.90). The affected side exhibited less gliding (p = 0.001) and smaller active ROM (p = 0.002) than the healthy side. Meanwhile, a significant correlation between tendon gliding and passive ROM was found only on the healthy side (ρ = 0.711, p = 0.009). CONCLUSION: The present study provides a promising protocol to evaluate post-operative tendon recovery by quantifying the amount of FFT gliding with a validated UST. FFT gliding in patients with different levels of ROM restriction should be further explored for categorizing the severity of tendon adhesion.


Assuntos
Traumatismos dos Tendões , Humanos , Animais , Suínos , Traumatismos dos Tendões/diagnóstico por imagem , Traumatismos dos Tendões/cirurgia , Reprodutibilidade dos Testes , Técnicas de Sutura , Tendões/diagnóstico por imagem , Tendões/cirurgia , Dedos/cirurgia , Fenômenos Biomecânicos
6.
Ann Biomed Eng ; 49(1): 262-275, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32483747

RESUMO

The quick onset of muscle fatigue is a critical issue when applying neuromuscular electrical stimulation (NMES) to generate muscle contractions for functional limb movements, which were lost/impaired due to a neurological disorder or an injury. For in situ assessment of the effect of NMES-induced muscle fatigue, a novel noninvasive sensor modality that can quantify the degraded contractility of a targeted muscle is required. In this study, instantaneous strain maps of a contracting muscle were derived from ultra-high-frame-rate (2 kHz) ultrasound images to quantify the contractility. A correlation between strain maps and isometric contraction force values was investigated. When the muscle reached its maximum contraction, the maximum and the mean values of the strain map were correlated with the force values and were further used to stage the contractility change. During the muscle activation period, a novel methodology based on the principal component regression (PCR) was proposed to explore the strain-force correlation. The quadriceps muscle of 3 able-bodied human participants was investigated during NMES-elicited isometric knee extension experiments. Strong to very strong correlation results were obtained and indicate that the proposed measurements from ultrasound images are promising to quantify the muscle contractility changes during NMES.


Assuntos
Fadiga Muscular/fisiologia , Músculo Quadríceps/diagnóstico por imagem , Músculo Quadríceps/fisiologia , Adulto , Estimulação Elétrica , Feminino , Humanos , Contração Isométrica , Masculino , Ultrassonografia , Adulto Jovem
7.
J Biomech ; 80: 16-22, 2018 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-30224164

RESUMO

There is increasing evidence that tendons are heterogeneous and take advantage of structural mechanisms to enhance performance and reduce injury. Fascicle-sliding, for example, is used by energy-storing tendons to enable them to undergo large extensions while protecting the fascicles from damage. Reductions in fascicle-sliding capacity may thus predispose certain populations to tendinopathy. Evidence from the Achilles tendon of significant superficial-to-deep non-uniformity that is reduced with age supports this theory. Similar patellar tendon non-uniformity has been observed, but the effects of age and sex have yet to be assessed. Healthy adults (n = 50, 25M/25F) from a broad range of ages (23-80) were recruited and non-uniformity was quantified using ultrasound speckle-tracking during passive knee extension. Significant superficial-to-deep non-uniformity and proximal/distal variations were observed. No effect of age was found, but males exhibited significantly greater non-uniformity than females (p < 0.05). The results contrast with previous findings in the Achilles tendon; in this study, tendons and tendon regions at high risk for tendinopathy (i.e. males and proximal regions, respectively) exhibited greater non-uniformity, whereas high-risk Achilles tendons (i.e. older adults) previously showed reduced non-uniformity. This suggests that non-uniformity may be dominated by factors other than fascicle-sliding. Anatomically, the varied proximal attachment of the patellar tendon may influence non-uniformity, with quadriceps passive resistance limiting superficial tendon movement, thus linking flexibility, non-uniformity and injury risk. This study also provides evidence of a differential effect of aging on the patellar tendon compared with evidence from prior studies on other tendons necessitating further study to elucidate links between non-uniformity and injury.


Assuntos
Ligamento Patelar/anatomia & histologia , Ligamento Patelar/diagnóstico por imagem , Tendões/anatomia & histologia , Tendões/diagnóstico por imagem , Tendão do Calcâneo/anatomia & histologia , Tendão do Calcâneo/diagnóstico por imagem , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Joelho/fisiologia , Masculino , Pessoa de Meia-Idade , Movimento , Músculo Quadríceps/anatomia & histologia , Músculo Quadríceps/diagnóstico por imagem , Fatores Sexuais , Tendinopatia/fisiopatologia , Ultrassonografia , Adulto Jovem
8.
J Innov Opt Health Sci ; 10(6)2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29399203

RESUMO

The three-dimensional (3D) mechanical response of the cornea to intraocular pressure (IOP) elevation has not been previously reported. In this study, we use an ultrasound speckle tracking technique to measure the 3D displacements and strains within the central 5.5 mm of porcine corneas during the whole globe inflation. Inflation tests were performed on dextran-treated corneas (treated with a 10% dextran solution) and untreated corneas. The dextran-treated corneas showed an inflation response expected of a thin spherical shell, with through-thickness thinning and in-plane stretch, although the strain magnitudes exhibited a heterogeneous spatial distribution from the central to more peripheral cornea. The untreated eyes demonstrated a response consistent with swelling during experimentation, with through-thickness expansion overriding the inflation response. The average volume ratios obtained in both groups was near 1 confirming general incompressibility, but local regions of volume loss or expansion were observed. These results suggest that biomechanical measurements in 3D provide important new insight to understand the mechanical response of ocular tissues such as the cornea.

9.
J Biomech ; 61: 258-262, 2017 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-28802742

RESUMO

Ultrasound-based methods have shown promise in their ability to characterize non-uniform deformations in large energy-storing tendons such as the Achilles and patellar tendons, yet applications to other areas of the body have been largely unexplored. The noninvasive quantification of collateral ligament strain could provide an important clinical metric of knee frontal plane stability, which is relevant in ligament injury and for measuring outcomes following total knee arthroplasty. In this pilot cadaveric experiment, we investigated the possibility of measuring collateral ligament strain with our previously validated speckle-tracking approach, but encountered a number of challenges during both data acquisition and processing. Given the clinical interest in this type of tool, and the fact that this is a developing area of research, the goal of this article is to transparently describe this pilot study, both in terms of methods and results, while also identifying specific challenges to this work and areas for future study. Some challenges faced relate generally to speckle-tracking of soft tissues (e.g. the limitations of using a 2D imaging modality to characterize 3D motion), while others are specific to this application (e.g. the small size and complex anatomy of the collateral ligaments). This work illustrates a clear need for additional studies, particularly relating to the collection of ground-truth data and more thorough validation work. These steps will be critical prior to the translation of ultrasound-based measures of collateral ligament strains into the clinic.


Assuntos
Ligamento Colateral Médio do Joelho/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Elasticidade , Feminino , Humanos , Masculino , Ligamento Colateral Médio do Joelho/fisiologia , Projetos Piloto , Ultrassonografia
10.
Ann Biomed Eng ; 44(7): 2302-12, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26563101

RESUMO

This study aimed to develop and validate a high frequency ultrasound method for measuring distributive, 3D strains in the sclera during elevations of intraocular pressure. A 3D cross-correlation based speckle-tracking algorithm was implemented to compute the 3D displacement vector and strain tensor at each tracking point. Simulated ultrasound radiofrequency data from a sclera-like structure at undeformed and deformed states with known strains were used to evaluate the accuracy and signal-to-noise ratio (SNR) of strain estimation. An experimental high frequency ultrasound (55 MHz) system was built to acquire 3D scans of porcine eyes inflated from 15 to 17 and then 19 mmHg. Simulations confirmed good strain estimation accuracy and SNR (e.g., the axial strains had less than 4.5% error with SNRs greater than 16.5 for strains from 0.005 to 0.05). Experimental data in porcine eyes showed increasing tensile, compressive, and shear strains in the posterior sclera during inflation, with a volume ratio close to one suggesting near-incompressibility. This study established the feasibility of using high frequency ultrasound speckle tracking for measuring 3D tissue strains and its potential to characterize physiological deformations in the posterior eye.


Assuntos
Pressão Intraocular , Esclera/diagnóstico por imagem , Esclera/fisiopatologia , Ultrassonografia/métodos , Animais , Razão Sinal-Ruído , Suínos , Resistência à Tração
11.
Med Eng Phys ; 37(7): 712-6, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25962378

RESUMO

The purpose of this study was to investigate middle-age effects on Achilles displacement patterns under passive stretch and eccentric loading. Healthy young (24.1 ± 1.4 years, n = 9) and middle-aged (49.0 ± 3.1 years, n = 9) adults were positioned prone and the ankle was cyclically dorsiflexed (0.5 Hz, 25° range) during passive stretch and active lengthening. Achilles displacements were tracked in cine ultrasound using 2D speckle tracking. Displacements were found to be non-uniform, with mid and deep portions of the tendon displacing more than superficial portions. However, the degree of non-uniformity was significantly reduced in middle-aged adults, suggesting a potential age-related reduction in inter-fascicle sliding or a shift in loading sharing between plantarflexors. Eccentric loading reduced displacement magnitudes, likely reflecting distal tendon stretch induced via active muscle contractions. Changes in tendon displacement with active loading were greater in middle-aged adults, which could reflect greater tendon compliance. The observed age-related changes in Achilles tendon behavior may have implications for both plantarflexor performance and injury risk.


Assuntos
Tendão do Calcâneo/fisiologia , Envelhecimento/fisiologia , Movimento/fisiologia , Tendão do Calcâneo/anatomia & histologia , Tendão do Calcâneo/diagnóstico por imagem , Envelhecimento/patologia , Articulação do Tornozelo/fisiologia , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Amplitude de Movimento Articular/fisiologia , Ultrassonografia , Adulto Jovem
12.
Ultrasonics ; 56: 399-408, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25262347

RESUMO

Ultrasound speckle tracking for carotid strain assessment has in the past decade gained interest in studies of arterial stiffness and cardiovascular diseases. The aim of this study was to validate and directly contrast carotid strain assessment by speckle tracking applied on clinical and high-frequency ultrasound images in vitro. Four polyvinyl alcohol phantoms mimicking the carotid artery were constructed with different mechanical properties and connected to a pump generating carotid flow profiles. Gray-scale ultrasound long- and short-axis images of the phantoms were obtained using a standard clinical ultrasound system, Vivid 7 (GE Healthcare, Horten, Norway) and a high-frequency ultrasound system, Vevo 2100 (FUJIFILM, VisualSonics, Toronto, Canada) with linear-array transducers (12L/MS250). Radial, longitudinal and circumferential strains were estimated using an in-house speckle tracking algorithm and compared with reference strain acquired by sonomicrometry. Overall, the estimated strain corresponded well with the reference strain. The correlation between estimated peak strain in clinical ultrasound images and reference strain was 0.91 (p<0.001) for radial strain, 0.73 (p<0.001) for longitudinal strain and 0.90 (p<0.001) for circumferential strain and for high-frequency ultrasound images 0.95 (p<0.001) for radial strain, 0.93 (p<0.001) for longitudinal strain and 0.90 (p<0.001) for circumferential strain. A significant larger bias and root mean square error was found for circumferential strain estimation on clinical ultrasound images compared to high frequency ultrasound images, but no significant difference in bias and root mean square error was found for radial and longitudinal strain when comparing estimation on clinical and high-frequency ultrasound images. The agreement between sonomicrometry and speckle tracking demonstrates that carotid strain assessment by ultrasound speckle tracking is feasible.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Algoritmos , Artérias Carótidas/fisiologia , Humanos , Imagens de Fantasmas , Ultrassonografia
13.
Ultrasound Med Biol ; 41(4): 1029-42, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25616585

RESUMO

Being multilayered and anisotropic, biological tissues such as cardiac and arterial walls are structurally complex, making the full assessment and understanding of their mechanical behavior challenging. Current standard mechanical testing uses surface markers to track tissue deformations and does not provide deformation data below the surface. In the study described here, we found that combining mechanical testing with 3-D ultrasound speckle tracking could overcome this limitation. Rat myocardium was tested with a biaxial tester and was concurrently scanned with high-frequency ultrasound in three dimensions. The strain energy function was computed from stresses and strains using an iterative non-linear curve-fitting algorithm. Because the strain energy function consists of terms for the base matrix and for embedded fibers, spatially varying fiber orientation was also computed by curve fitting. Using finite-element simulations, we first validated the accuracy of the non-linear curve-fitting algorithm. Next, we compared experimentally measured rat myocardium strain energy function values with those in the literature and found a matching order of magnitude. Finally, we retained samples after the experiments for fiber orientation quantification using histology and found that the results satisfactorily matched those computed in the experiments. We conclude that 3-D ultrasound speckle tracking can be a useful addition to traditional mechanical testing of biological tissues and may provide the benefit of enabling fiber orientation computation.


Assuntos
Ecocardiografia Tridimensional/métodos , Estresse Mecânico , Algoritmos , Animais , Fenômenos Biomecânicos , Ratos
14.
J Biomech ; 47(5): 1151-6, 2014 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-24438767

RESUMO

This study aimed to characterize the mechanical responses of the sclera, the white outer coat of the eye, under equal-biaxial loading with unrestricted shear. An ultrasound speckle tracking technique was used to measure tissue deformation through sample thickness, expanding the capabilities of surface strain techniques. Eight porcine scleral samples were tested within 72 h postmortem. High resolution ultrasound scans of scleral cross-sections along the two loading axes were acquired at 25 consecutive biaxial load levels. An additional repeat of the biaxial loading cycle was performed to measure a third normal strain emulating a strain gage rosette for calculating the in-plane shear. The repeatability of the strain measurements during identical biaxial ramps was evaluated. A correlation-based ultrasound speckle tracking algorithm was used to compute the displacement field and determine the distributive strains in the sample cross-sections. A Fung type constitutive model including a shear term was used to determine the material constants of each individual specimen by fitting the model parameters to the experimental stress-strain data. A non-linear stress-strain response was observed in all samples. The meridian direction had significantly larger strains than that of the circumferential direction during equal-biaxial loadings (P's<0.05). The stiffness along the two directions was also significantly different (P=0.02) but highly correlated (R(2)=0.8). These results showed that the mechanical properties of the porcine sclera were nonlinear and anisotropic under biaxial loading. This work has also demonstrated the feasibility of using ultrasound speckle tracking for strain measurements during mechanical testing.


Assuntos
Esclera/fisiologia , Algoritmos , Animais , Anisotropia , Fenômenos Biomecânicos , Esclera/diagnóstico por imagem , Estresse Mecânico , Suínos , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA