Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.058
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Circulation ; 149(22): e1223-e1238, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38660790

RESUMO

Tricuspid valve disease is an often underrecognized clinical problem that is associated with significant morbidity and mortality. Unfortunately, patients will often present late in their disease course with severe right-sided heart failure, pulmonary hypertension, and life-limiting symptoms that have few durable treatment options. Traditionally, the only treatment for tricuspid valve disease has been medical therapy or surgery; however, there have been increasing interest and success with the use of transcatheter tricuspid valve therapies over the past several years to treat patients with previously limited therapeutic options. The tricuspid valve is complex anatomically, lying adjacent to important anatomic structures such as the right coronary artery and the atrioventricular node, and is the passageway for permanent pacemaker leads into the right ventricle. In addition, the mechanism of tricuspid pathology varies widely between patients, which can be due to primary, secondary, or a combination of causes, meaning that it is not possible for 1 type of device to be suitable for treatment of all cases of tricuspid valve disease. To best visualize the pathology, several modalities of advanced cardiac imaging are often required, including transthoracic echocardiography, transesophageal echocardiography, cardiac computed tomography, and cardiac magnetic resonance imaging, to best visualize the pathology. This detailed imaging provides important information for choosing the ideal transcatheter treatment options for patients with tricuspid valve disease, taking into account the need for the lifetime management of the patient. This review highlights the important background, anatomic considerations, therapeutic options, and future directions with regard to treatment of tricuspid valve disease.


Assuntos
American Heart Association , Valva Tricúspide , Humanos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/patologia , Estados Unidos , Doenças das Valvas Cardíacas/terapia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/terapia , Implante de Prótese de Valva Cardíaca
2.
Artigo em Inglês | MEDLINE | ID: mdl-39110339

RESUMO

PURPOSE: Staphylococcus aureus prosthetic valve endocarditis (SAPVE) is a serious infection with high mortality. The main objective of this study was to identify factors associated with in-hospital mortality. METHODS: From January 2008 to December 2021, consecutive patients from a Spanish cohort of infective endocarditis with a definitive diagnosis of SAPVE were analyzed. RESULTS: During the study period, 219 cases of definitive SAPVE were diagnosed, which accounted for 16.7% of a total of 1309 cases of definitive prosthetic valve endocarditis (PVE). Patients presented advanced age and marked comorbidity. There was a higher incidence of persistent bacteremia, septic shock, stroke, and acute kidney injury than in cases of PVE caused by other microorganisms. Methicillin resistance was not associated with differences in clinical presentation, echocardiographic findings, or mortality. Only 50.6% of the patients with surgical indications (88 patients) underwent surgery. Overall, in-hospital mortality was 47.9%. The variables associated with in-hospital mortality were age (OR:1.03, 95% CI: 1.00-1.05; p = 0.016), heart failure (OR:2.86, 95% CI: 1.53-5.32; p = 0.001), acute kidney injury (OR:2.42, 95%CI:1.28-4.58; p = 0.006), stroke (OR:3.53, 95%CI:1.79-6.96; p < 0.001) and surgery indicated but not performed (OR:2.01, 95%CI:1.06-3.8; p = 0.030). On the other hand, the performance of surgery per se in patients with SAPVE, regardless of whether there was a surgical indication according to the guidelines, was not associated with a reduction in in-hospital mortality. CONCLUSIONS: SAPVE is characterized by high mortality, which is more marked in patients who present a surgical indication but do not undergo surgery.

3.
Crit Care ; 28(1): 111, 2024 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-38581030

RESUMO

BACKGROUND: Optimal intensive care of patients undergoing valve surgery is a complex balancing act between sedation for monitoring and timely postoperative awakening. It remains unclear, if these requirements can be fulfilled by volatile sedations in intensive care medicine in an efficient manner. Therefore, this study aimed to assess the time to extubation and secondary the workload required. METHODS: We conducted a prospective randomized single-center trial at a tertiary university hospital to evaluate the postoperative management of open valve surgery patients. The study was randomized with regard to the use of volatile sedation compared to propofol sedation. Sedation was discontinued 60 min after admission for critical postoperative monitoring. RESULTS: We observed a significantly earlier extubation (91 ± 39 min vs. 167 ± 77 min; p < 0.001), eye-opening (86 ± 28 min vs. 151 ± 71 min; p < 0.001) and command compliance (93 ± 38 min vs. 164 ± 75 min; p < 0.001) using volatile sedation, which in turn was associated with a significantly increased workload of a median of 9:56 min (± 4:16 min) set-up time. We did not observe any differences in complications. Cardiopulmonary bypass time did not differ between the groups 101 (IQR 81; 113) versus 112 (IQR 79; 136) minutes p = 0.36. CONCLUSIONS: Using volatile sedation is associated with few minutes additional workload in assembling and enables a significantly accelerated evaluation of vulnerable patient groups. Volatile sedation has considerable advantages and emerges as a safe sedation technique in our vulnerable study population. TRIAL REGISTRATION: Clinical trials registration (NCT04958668) was completed on 1 July 2021.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Propofol , Humanos , Propofol/uso terapêutico , Estudos Prospectivos , Procedimentos Cirúrgicos Cardíacos/métodos , Cuidados Críticos/métodos , Extubação , Hipnóticos e Sedativos/uso terapêutico
4.
Artigo em Inglês | MEDLINE | ID: mdl-38522874

RESUMO

The so-called Commando procedure, initially described by David and colleagues, consists in the reconstruction of the mitro-aortic fibrous lamina by a patch that enlarges both annuli. Its use has been described to upsize the aortic and mitral annulus for double valve replacement in adolescents. We describe a modified technique of this reconstruction of the fibrous skeleton of the heart, combined with Konno procedure to further enlarge the aortic annulus. In modified Commando procedure, following the reconstruction of aortomitral continuity with a bovine pericardium CardioCel patch (Admedus Regen Pty Ltd, Perth, WA, Australia), an aortic valved conduit that was made on the bench in order to have bottom skirt that enabled the suturing of the composite conduit far inside the left ventricle outflow tract. Coronary buttons were implanted at the supra-commissural level. The advantages of this modified Commando procedure are (1) the creation of a new aortic annulus when the integrity of this annulus has been compromised, (2) the upsizing of both annuli to any possible size of aortic and mitral prostheses, and (3) the relief of any residual left ventricular outflow tract obstruction.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Criança , Adolescente , Animais , Bovinos , Humanos , Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Valva Mitral/cirurgia , Próteses e Implantes
5.
J Artif Organs ; 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38769278

RESUMO

Preclinical testing using animal models is indispensable in cardiovascular research. However, the translation to clinical practice of these animal models is questionable since it is not always clear how representative they are. This systematic review intends to summarize the interspecies differences in the coagulation profile of animal models used in cardiovascular research. It aims to guide future research in choosing the optimal animal species. A literature search of PubMed, Embase, Web of Science (Core Collection) and Cochrane Library was performed using a search string that was well defined and not modified during the study. An overview of the search terms used in each database can be found in the appendix. Articles describing coagulation systems in large animals were included. We identified 30 eligible studies of which 15 were included. Compared to humans, sheep demonstrated a less active external pathway of coagulation. Sheep had a higher platelet count but the platelet activatability and response to biomaterials were lower. Both sheep and pigs displayed no big differences in the internal coagulation system compared to humans. Pigs showed results very similar to those of humans, with the exception of a higher platelet count and stronger platelet aggregation in pigs. Coagulation profiles of different species used for preclinical testing show strong variation. Adequate knowledge of these differences is key in the selection of the appropriate species for preclinical cardiovascular research. Future thrombogenicity research should compare sheep to pig in an identical experimental setup.

6.
Molecules ; 29(13)2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38999030

RESUMO

Coatings with xenogenic materials, made of detonation nanodiamonds, provide additional strength and increase elasticity. A functionally developed surface of nanodiamonds makes it possible to apply antibiotics. Previous experiments show the stability of such coatings; however, studies on stability in the bloodstream and calcification of the material in natural conditions have yet to be conducted. Tritium-labeled nanodiamonds (negative and positive) were obtained by the tritium activation method and used to develop coatings for a pork aorta to analyze their stability in a pig's bloodstream using a radiotracer technique. A chitosan layer was applied from a solution of carbonic acid under high-pressure conditions to prevent calcification. The obtained materials were used to prepare a porcine conduit, which was surgically stitched inside the pig's aorta for four months. The aorta samples, including nanodiamond-coated and control samples, were analyzed for nanodiamond content and calcium, using the radiotracer and ICP-AES methods. A histological analysis of the materials was also performed. The obtained coatings illustrate a high in vivo stability and low levels of calcification for all types of nanodiamonds. Even though we did not use additional antibiotics in this case, the development of infection was not observed for negatively charged nanodiamonds, opening up prospects for their use in developing coatings.


Assuntos
Materiais Revestidos Biocompatíveis , Nanodiamantes , Trítio , Animais , Nanodiamantes/química , Suínos , Materiais Revestidos Biocompatíveis/química , Trítio/química , Aorta , Bioprótese , Quitosana/química , Próteses Valvulares Cardíacas
7.
J Anat ; 242(1): 50-63, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36152032

RESUMO

Minimally invasive approaches for aortic valve replacement are now at the forefront of pathological aortic valve treatment. New trials show comparability of these devices to existing therapies, not only in high-risk surgical cohorts but also in low-risk and intermediate-risk cohorts. This review provides vital clinical and anatomical background to aortic valvular disease treatment guidelines, while also providing an update on transcatheter aortic valve implantation (TAVI) devices in Europe, their interventional trials and associated complications.


Assuntos
Estenose da Valva Aórtica , COVID-19 , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 101(3): 639-650, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36655511

RESUMO

BACKGROUND: Permanent pacemaker implantation (PPI) is a common complication after transcatheter aortic valve implantation (TAVI). The cusp-overlap view (COV) was adopted to reduce PPI risk after TAVI with self-expandable valves (SEVs); however, the evidence remains scarce. We performed a systematic review with meta-analysis comparing COV and the standard coplanar view (CPV) technique to evaluate their effectiveness and safety. METHODS: Following the PRISMA statement, data were extracted from studies published by August 2022 and found in PubMed/MEDLINE, EMBASE, CENTRAL/CCTR, ClinicalTrials.gov, SciELO, LILACS, and Google Scholar. The primary outcome of interest was post-procedural PPI and the secondary outcomes were new left bundle branch block (LBBB), moderate/severe paravalvular leak (PVL), valve dislocation (pop-out); need of second transcatheter heart valve, 30-day mortality, stroke, conversion to surgery, coronary obstruction, implantation depth (mm), and post-TAVI mean gradients (mmHg). RESULTS: Eleven studies met our eligibility criteria and included 1464 patients in the COV group and 1743 patients in the CPV group. Patients who underwent TAVI with COV had lower risk of PPI (odds ratio 0.48; 95% confidence interval [CI] 0.33-0.70; p = 0.001) and higher implantation depths with COV (mean difference -0.83; 95% CI -1.2 to -0.45; p < 0.001). We did not observe any statistically significant differences in the rates of new LBBB, moderate/severe PVL, valve dislocation, need of second transcatheter heart valve, 30-day mortality, stroke, conversion to surgery, coronary obstruction, and post-TAVI mean gradients (mmHg). CONCLUSION: In TAVI with SEVs, the application of COV is associated with lower risk of PPI compared with the standard CPV without increasing risk for adverse outcomes.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Arritmias Cardíacas/etiologia , Bloqueio de Ramo/etiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
9.
Catheter Cardiovasc Interv ; 101(7): 1203-1213, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37070459

RESUMO

BACKGROUND: Permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) is associated with higher risk of mortality and rehospitalization for heart failure. Efforts to prevent conduction abnormalities (CA) requiring PPI after TAVI should be made. The membranous septum (MS) length and its interaction with implantation depth (ID-ΔMSID) could provide useful information about the risk of CA/PPI following TAVI. OBJECTIVES: To identify MS length and ΔMSID as predictors of CA/PPI following TAVI. METHODS: Study-level meta-analysis of studies published by September 30, 2022. RESULTS: Eighteen studies met our eligibility including 5740 patients. Shorter MS length was associated with a significantly higher risk of CA/PPI (per 1 mm decrease: odds ratio [OR] 1.60, 95% confidence interval [CI] 1.28-1.99, p < 0.001). Similarly, lower ΔMSID was associated with a significantly higher risk of CA/PPI (per 1 mm decrease: OR 1.75, 95% CI 1.32-2.31, p < 0.001). Meta-regression analyses revealed a statistically significant modulation of the effect of shorter MS length and lower ΔMSID on the outcome (CA/PPI) by balloon postdilatation (positive regression coefficients with p < 0.001); with increasing use of balloon postdilatation, the effect of shorter MS length and lower ΔMSID on the outcome increased. MS length and ΔMSID demonstrated excellent discriminative abilities, with diagnostic ORs equaling 9.49 (95% CI 4.73-19.06), and 7.19 (95% CI 3.31-15.60), respectively. CONCLUSION: Considering that short MS length and low ΔMSID are associated with higher risk of CA and PPI, we should include measurement of MS length in the pre-TAVI planning with MDCT and try to establish optimal ID values before the procedure to avoid CA/PPI.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Resultado do Tratamento , Tomografia Computadorizada por Raios X , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
10.
J Cardiothorac Vasc Anesth ; 37(9): 1591-1598, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36462976

RESUMO

OBJECTIVES: Perioperative transfusion thresholds have garnered increasing scrutiny as restrictive strategies have been shown to be noninferior. The study authors used data from a statewide academic collaborative to test the association between transfusion and 30-day mortality. DESIGN: All adult patients undergoing coronary artery bypass grafting (CABG) and/or valve surgeries between 2013 and 2019 in the authors' Academic Cardiac Surgery Consortium were examined. The relationship between the number of overall packed red blood cell (pRBC) and coagulation product (CP) (fresh frozen plasma, cryoprecipitate, platelets) transfusions on 30-day mortality was evaluated. Multivariate regression was used to evaluate predictors of transfusion and study endpoints. Machine learning (ML) models also were developed to predict 30-day mortality and rank transfusion-related features by relative importance. SETTING: At an Academic Cardiac Surgery Consortium of 5 institutions. PARTICIPANTS: Patients ≥18 years old undergoing CABG and/or valve surgeries. MEASUREMENTS AND MAIN RESULTS: Of the 7,762 patients (median hematocrit [HCT] 39%, IQR 35%-43%) who were included in the final study cohort, >40% were transfused at least 1 unit of pRBC or CP. In adjusted analyses, higher preoperative HCT was associated with reduced odds of mortality (adjusted odds ratio [aOR] 0.95, 95% CI 0.92-0.98), renal failure (aOR 0.95, 95% CI 0.92-0.98), and prolonged mechanical ventilation (aOR 0.97, 95% CI 0.95-0.99). In contrast, perioperative transfusions were associated with increased 30-day mortality after adjustment for preoperative HCT and other baseline features. The ML models were able to predict 30-day mortality with an area under the curve of 0.814-to-0.850, with perioperative transfusions displaying the highest feature importance. CONCLUSIONS: The present analysis found increasing HCT to be associated with a lower incidence of mortality. The study authors also found a direct dose-response association between transfusions and all study endpoints examined.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cirurgia Torácica , Humanos , Adulto , Adolescente , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Transfusão de Sangue , Ponte de Artéria Coronária , Morbidade
11.
Perfusion ; 38(2): 432-435, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35289195

RESUMO

Background: Paravalvular leak (PVL) is a recognized and challenging complication after surgical or transcatheter valve replacement. The transcatheter closure of PVL has become the first-line treatment in clinical practice when the procedure is not contraindicated. Transcatheter PVL closure rests on a complex procedure and complications still occur in approximately 9% of patients. Case Report: We describe the case of a delayed mechanical prosthetic leaflet impingement after transcatheter closure of a paravalvular leak associated with a Valsalva pseudoaneurysm that required an urgent surgery. Conclusion: Aorta-left ventricle communication could be a relative contraindication to be assessed on a case-by-case basis, but transcatheter closure does not preclude subsequent attempt for surgical repair and outcome.


Assuntos
Falso Aneurisma , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Cateterismo Cardíaco/métodos , Falha de Prótese
12.
Perfusion ; 38(4): 807-817, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35430909

RESUMO

INTRODUCTION: Haemolysis and inflammation contribute to cardiac surgery-associated acute kidney injury (CS-AKI). We aimed to assess the performance of plasma haemolysis index (HI) and interleukine-6 (IL-6) for the prediction of all-stage CS-AKI. We also assessed their ability to predict moderate-to-severe CS-AKI and to discriminate persistent from transient CS-AKI. METHODS: Adult patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) were prospectively included. Haemolysis index and IL-6 were measured immediately after the end of CPB and 6 hours later. Correction for haemodilution relied upon changes in albuminaemia. Persistent CS-AKI was defined as a steady/increasing CS-AKI stage between the 48th and the 60th postoperative hour as compared with the worst stage observed within the 48 first hours. RESULTS: Among 82 patients, CS-AKI occurred in 37 (45%) patients. Postoperative HI and IL-6 were positively correlated to the duration of CPB (r ≤ 0.51, p ≤ 0.0003). Whether we considered isolated measurements of HI or IL-6, their indexation to haemodilution or not, their kinetics and/or their combination, the prediction of all stage CS-AKI was inaccurate (area under the receiver operating characteristic curve [AUCROC]≤ 0.68) whereas moderate-to-severe CS-AKI (6 patients only) was predicted with an honourable performance (AUCROC = 0.77 [95%CI 0.67;0.86] and 0.87 [95%CI 0.77;0.93] for HI and IL-6, respectively). The persistent/transient nature of CS-AKI was inaccurately predicted (AUCROC ≤ 0.68). CONCLUSIONS: In a population in which most CS-AKI cases were mild, although they frequently (41%) persisted >48 hours, CS-AKI was inaccurately predicted by HI and/or IL-6. A better performance for moderate-to-severe CS-AKI prediction is likely. These preliminary findings are yet to be validated.


Assuntos
Injúria Renal Aguda , Procedimentos Cirúrgicos Cardíacos , Adulto , Humanos , Lipocalina-2 , Interleucina-6 , Proteínas Proto-Oncogênicas , Hemólise , Proteínas de Fase Aguda , Biomarcadores , Valor Preditivo dos Testes , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/etiologia , Ponte Cardiopulmonar/efeitos adversos , Creatinina , Complicações Pós-Operatórias
13.
Sensors (Basel) ; 23(8)2023 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-37112167

RESUMO

IntraValvular Impedance (IVI) sensing is an innovative concept for monitoring heart valve prostheses after implant. We recently demonstrated IVI sensing feasible in vitro for biological heart valves (BHVs). In this study, for the first time, we investigate ex vivo the IVI sensing applied to a BHV when it is surrounded by biological tissue, similar to a real implant condition. A commercial model of BHV was sensorized with three miniaturized electrodes embedded in the commissures of the valve leaflets and connected to an external impedance measurement unit. To perform ex vivo animal tests, the sensorized BHV was implanted in the aortic position of an explanted porcine heart, which was connected to a cardiac BioSimulator platform. The IVI signal was recorded in different dynamic cardiac conditions reproduced with the BioSimulator, varying the cardiac cycle rate and the stroke volume. For each condition, the maximum percent variation in the IVI signal was evaluated and compared. The IVI signal was also processed to calculate its first derivative (dIVI/dt), which should reflect the rate of the valve leaflets opening/closing. The results demonstrated that the IVI signal is well detectable when the sensorized BHV is surrounded by biological tissue, maintaining the similar increasing/decreasing trend that was found during in vitro experiments. The signal can also be informative on the rate of valve opening/closing, as indicated by the changes in dIVI/dt in different dynamic cardiac conditions.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Próteses Valvulares Cardíacas , Animais , Suínos , Impedância Elétrica , Implantação de Prótese , Animais de Laboratório , Desenho de Prótese
14.
Circulation ; 144(3): 186-194, 2021 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-33947202

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a transformative therapy for aortic stenosis. Despite rapid improvements in technology and techniques, serious complications remain relatively common and are not well described by single outcome measures. The purpose of this study was to determine whether there is site-level variation in TAVR outcomes in the United States using a novel 30-day composite measure. METHODS: We performed a retrospective cohort study using data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapies Registry to develop a novel ranked composite performance measure that incorporates mortality and serious complications. The selection and rank order of the complications for the composite was determined by their adjusted association with 1-year outcomes. Sites with risk-adjusted outcomes significantly more or less frequent than the national average based on a 95% probability interval were classified as performing worse or better than expected. RESULTS: The development cohort consisted of 52 561 patients who underwent TAVR between January 1, 2015, and December 31, 2017. Based on associations with 1-year risk-adjusted mortality and health status, we identified 4 periprocedural complications to include in the composite risk model in addition to mortality. Ranked empirically according to severity, these included stroke, major, life-threatening or disabling bleeding, stage III acute kidney injury, and moderate or severe perivalvular regurgitation. Based on these ranked outcomes, we found that there was significant site-level variation in quality of care in TAVR in the United States. Overall, better than expected site performance was observed in 25/301 (8%) sites, performance as expected was observed in 242/301 sites (80%), and worse than expected performance was observed in 34/301 (11%) sites. Thirty-day mortality; stroke; major, life-threatening, or disabling bleeding; and moderate or severe perivalvular leak were each substantially more common in sites with worse than expected performance as compared with other sites. There was good aggregate reliability of the model. CONCLUSIONS: There are substantial variations in the quality of TAVR care received in the United States and 11% of sites were identified as providing care below the average level of performance. Further study is necessary to determine structural, process-related, and technical factors associated with high- and low-performing sites.


Assuntos
Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/etiologia , Gerenciamento Clínico , Feminino , Pesquisas sobre Atenção à Saúde , Humanos , Masculino , Medidas de Resultados Relatados pelo Paciente , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Prognóstico , Sistema de Registros , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Estados Unidos/epidemiologia
15.
Circulation ; 143(25): e1088-e1114, 2021 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-33980041

RESUMO

Aortic stenosis with concomitant chronic kidney disease (CKD) represents a clinical challenge. Aortic stenosis is more prevalent and progresses more rapidly and unpredictably in CKD, and the presence of CKD is associated with worse short-term and long-term outcomes after aortic valve replacement. Because patients with advanced CKD and end-stage kidney disease have been excluded from randomized trials, clinicians need to make complex management decisions in this population that are based on retrospective and observational evidence. This statement summarizes the epidemiological and pathophysiological characteristics of aortic stenosis in the context of CKD, evaluates the nuances and prognostic information provided by noninvasive cardiovascular imaging with echocardiography and advanced imaging techniques, and outlines the special risks in this population. Furthermore, this statement provides a critical review of the existing literature pertaining to clinical outcomes of surgical versus transcatheter aortic valve replacement in this high-risk population to help guide clinical decision making in the choice of aortic valve replacement and specific prosthesis. Finally, this statement provides an approach to the perioperative management of these patients, with special attention to a multidisciplinary heart-kidney collaborative team-based approach.


Assuntos
American Heart Association , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/terapia , Gerenciamento Clínico , Insuficiência Renal Crônica/diagnóstico por imagem , Insuficiência Renal Crônica/terapia , Estenose da Valva Aórtica/epidemiologia , Comorbidade , Ecocardiografia/normas , Humanos , Insuficiência Renal Crônica/epidemiologia , Medição de Risco/métodos , Estados Unidos/epidemiologia
16.
Circulation ; 143(10): 1043-1061, 2021 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-33683945

RESUMO

After 15 years of successive randomized, controlled trials, indications for transcatheter aortic valve replacement (TAVR) are rapidly expanding. In the coming years, this procedure could become the first line treatment for patients with a symptomatic severe aortic stenosis and a tricuspid aortic valve anatomy. However, randomized, controlled trials have excluded bicuspid aortic valve (BAV), which is the most frequent congenital heart disease occurring in 1% to 2% of the total population and representing at least 25% of patients 80 years of age or older referred for aortic valve replacement. The use of a less invasive transcatheter therapy in this elderly population became rapidly attractive, and approximately 10% of patients currently undergoing TAVR have a BAV. The U.S. Food and Drug Administration and the "European Conformity" have approved TAVR for low-risk patients regardless of the aortic valve anatomy whereas international guidelines recommend surgical replacement in BAV populations. Given this progressive expansion of TAVR toward younger and lower-risk patients, heart teams are encountering BAV patients more frequently, while the ability of this therapy to treat such a challenging anatomy remains uncertain. This review will address the singularity of BAV anatomy and associated technical challenges for the TAVR procedure. We will examine and summarize available clinical evidence and highlight critical knowledge gaps regarding TAVR utilization in BAV patients. We will provide a comprehensive overview of the role of computed tomography scans in the diagnosis, and classification of BAV and TAVR procedure planning. Overall, we will offer an integrated framework for understanding the current role of TAVR in the treatment of bicuspid aortic stenosis and for guiding physicians in clinical decision-making.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino
17.
J Intern Med ; 292(3): 428-437, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35373870

RESUMO

BACKGROUND: Prosthetic valve endocarditis (PVE) is a feared complication after heart valve surgery. Studies on differences in bacteriology in various types of PVE are limited. OBJECTIVES: This study aimed to investigate the microbiology of PVE depending on the type of prosthetic valve and timing of diagnosis. METHODS: A retrospective study based on the Swedish Registry on Infective Endocarditis focusing on PVE was conducted. The cohort was divided into mechanical and bioprosthetic valves; into endocarditis localization in the aortic, mitral, or tricuspid valve; and into early and late PVE. The microbiology in these groups was compared. Predictors of Staphylococcus aureus as the cause of PVE were examined by multivariable logistic regression. RESULTS: A total of 780 episodes of PVE in 749 patients were compared regarding the distribution of causative microbiological agents. The most common agents included alpha-hemolytic streptococci (29%), S. aureus (22%), enterococci (14%), coagulase-negative staphylococci (CoNS) (12%), and Cutibacterium acnes (6%). S. aureus was more commonly found on mechanical valves compared to bioprosthetic ones (36% vs. 17%, p < 0.001) whereas alpha-hemolytic streptococci, enterococci, and CoNS were more common on bioprosthetic valves. There were no significant differences in the microbiology of PVE affecting mitral or aortic valves or in cases of early and late PVE. Predictors for S. aureus as the cause of PVE were end-stage renal disease, intravenous drug use, mechanical valve, and tricuspid localization of endocarditis. CONCLUSIONS: The type of prosthetic heart valve is associated with the causative pathogen. Patients with mechanical valves are more likely to have PVE caused by S. aureus.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Endocardite/complicações , Endocardite/microbiologia , Endocardite Bacteriana/microbiologia , Próteses Valvulares Cardíacas/efeitos adversos , Próteses Valvulares Cardíacas/microbiologia , Humanos , Infecções Relacionadas à Prótese/complicações , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/cirurgia , Sistema de Registros , Estudos Retrospectivos , Staphylococcus aureus
18.
J Cardiovasc Electrophysiol ; 33(5): 997-1004, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35322490

RESUMO

INTRODUCTION: Device infections constitute a major complication of transvenous pacemakers. Mechanical heart valves (MHV) increase the risk of infective endocarditis (IE) and pacemaker infection, requiring lifelong vitamin K-antagonists (VKA), which may affect patient management. Leadless pacemakers (LP) are associated with low infection rates, posing an attractive option in MHV patients requiring permanent pacing. This study describes outcomes following LP implantation in patients with MHV. METHODS: This is a multicenter, observational, retrospective study including consecutive patients implanted with an LP at 5 centers between June 2015 and January 2020. Procedural outcomes, antithrombotic management, complications, performance during follow-up and episodes of bacteremia and IE were compared between patients with and without an MHV (MHV and non-MHV groups). RESULTS: Four hundred fifty-nine patients were included (74 in the MHV group, 16.1%, and 385 in the non-MHV group, 83.9%). Procedural outcomes and acute electrical performance were comparable between groups. Vascular complications and cardiac perforation occurred in 2.7 versus 2.3% (p = 1) and 0% versus 0.8% (p = 1) in the MHV group and non-MHV group. One case of IE occurred in the MHV group and 2 in the non-MHV group. In MHV patients, uninterrupted VKA was used in 83.8%, whereas 16.2% were heparin-bridged. Vascular complication or tamponade occurred in 1 (8.3%) MHV heparin-bridged patient versus 1 (1.6%) MHV uninterrupted VKA patient (p = .3). CONCLUSION: LP implantation outcomes in MHV patients are comparable to the general LP population. Device-related infections are rare following LP implantation, including in patients with MHV. In the MHV group, periprocedural anticoagulation management was not associated with significantly different rates of tamponade or vascular complication.


Assuntos
Próteses Valvulares Cardíacas , Marca-Passo Artificial , Valvas Cardíacas , Heparina , Humanos , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
19.
J Cardiothorac Vasc Anesth ; 36(8 Pt B): 3065-3073, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35550725

RESUMO

OBJECTIVES: The present authors aimed to assess the late outcomes of patients undergoing aortic root enlargement (ARE) at the time of surgical aortic valve replacement (SAVR). DESIGN: Study-level meta-analysis with reconstructed time-to-event data. SETTING: Follow-up of patients after surgical procedure. PARTICIPANTS: Adult patients with aortic valve disease requiring surgery. INTERVENTIONS: SAVR with ARE versus SAVR without ARE. MEASUREMENTS AND MAIN RESULTS: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses reporting guideline. The following databases were searched for studies meeting the authors' inclusion criteria and published by November 30, 2021: PubMed/MEDLINE, Embase, SciELO, LILACS, CCTR/CENTRAL, and Google Scholar. Nine nonrandomized studies met the authors' eligibility criteria. All studies were nonrandomized. A total of 213,134 patients (SAVR with ARE: 7,556 patients; SAVR without ARE: 205,578 patients) were included from studies published from 1997 to 2021. The total rate of AAE was 3.7%, varying in the studies from 2.9% to 28.1%. The studies consisted of patients whose mean age varied from 63 to 79 years. Patients in the SAVR with ARE group had a significantly better overall survival (hazard ratio [HR] 0.94, 95% confidence interval [CI] 0.90-0.99, p = 0.016) in the unmatched populations, but the matched analysis revealed no difference between SAVR with/without ARE in terms of overall survival (HR, 1.06; 95% CI, 0.90-1.25; p = 0.474). CONCLUSIONS: In the context of patients undergoing SAVR with or without ARE, patients who undergo ARE do not experience worse late outcomes. Further randomized controlled trials are needed to confirm or refute the authors' current findings.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Pessoa de Meia-Idade , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
20.
J Card Surg ; 37(12): 5588-5590, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36335637

RESUMO

This case report describes an initially stabilized transcatheter heart valve that embolized in the ascending aorta, leading to a postprocedural acute type A aortic dissection.


Assuntos
Dissecção Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Aorta/cirurgia , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA