Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
Beijing Da Xue Xue Bao Yi Xue Ban ; 55(1): 139-143, 2023 Feb 18.
Artigo em Chinês | MEDLINE | ID: mdl-36718702

RESUMO

OBJECTIVE: To assess the safety and efficacy of Neuroform Atlas stent used in treatment of unruptured wide-neck intracranial aneurysms. METHODS: Clinical data of 62 patients with unruptured wide-neck intracranial aneurysms undergoing Neuroform Atlas stent-assisted coiling from August 2020 to September 2021 were retrospectively analyzed. There were 64 aneurysms in those 62 patients. Among them, 25 aneurysms were located at the bifurcation of M1 segment on middle cerebral artery, 16 at the anterior communicating artery, 10 at the C7 segment of internal carotid artery, 5 at the C6 segment of internal carotid artery, 4 at the apex of basilar artery, 3 at the A3 segment of anterior cerebral artery, and 1 at the M2 segment of middle cerebral artery. All the patients underwent Neuroform Atlas stent-assisted coiling, including 49 patients with single stent assisted coiling and 15 patients with dual stents assisted coiling (14"Y"style and 1"X"style). After the procedure, the immediate DSA was performed to evaluate the status of aneurysm occlusion and the parent artery patency. The clinical follow-up was performed 3 months after the operation and evaluated based on the modified Rankin Scale(mRS).DSA image was reviewed at 6 months after operation and Raymond grading scale was used to assess the status of aneurysm occlusion and the parent artery patency. RESULTS: A total of 62 patients with 64 aneurysms were all achieved technical success(100%).The immediate post-procedural Raymond scale was assessed, including Raymond Ⅰ in 57 aneurysms(89.1%, 57/64), Raymond Ⅱ in 6 aneurysms(9.3%, 6/64) and Raymond Ⅲ in 1 aneurysm(1.6%, 1/64). The peri-procedural complications rate was 4.8%(3/62), 2 patients developed intraoperative thrombosis and 1 patient suffered from local subarachnoid hemorrhage. Among them, 55 patients obtained 3 months clinical follow-up after operation and all the patients had good outcomes (mRS≤2), 50 patients with 52 aneurysms were followed up with DSA 6 months after operation, including Raymond Ⅰ in 45 aneurysms(86.5%, 45/52), Raymond Ⅱ in 4 aneurysms(7.7%, 4/52) and Raymond Ⅲ in 3 aneurysms(5.8%, 3/52). CONCLUSION: Neuroform Atlas stent for the treatment of unruptured wide-neck intracranial aneurysms has high safety and good efficacy, and has its advantages over other traditional stents.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/cirurgia , Aneurisma Intracraniano/etiologia , Estudos Retrospectivos , Resultado do Tratamento , Embolização Terapêutica/métodos , Stents/efeitos adversos , Angiografia Cerebral
2.
Neurosurg Rev ; 45(4): 2717-2722, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35403981

RESUMO

The Woven EndoBridge device (WEB) was introduced in 2010 to treat wide-neck bifurcation aneurysms (WNBAs). Three landmark studies have been conducted to assess its safety and efficacy: WEBCAST, WEBCAST 2, and French Observatory Study. However, these studies have not compared its safety and efficacy to other treatment modalities. In this study, we compare WEB versus microsurgical clipping in the management of unruptured WNBA. We conducted a retrospective study of unruptured WNBA meeting the morphological criteria to be amenable for WEB treatment operated on at our institution. Surgical morbidity, mortality, and occlusion rates were assessed. We compared our results to those reported in the cumulative population of the three WEB landmark studies at 1 year. A total of 84 patients with 89 WNBA were included. The most common aneurysm location was the middle cerebral artery bifurcation (n = 67/89, 75%). No operative mortality was observed. Morbidity comprised small-vessel vasospasm (n = 1/89, 1%) resulting in hemiparesis vs. 3% morbidity for WEB (p = .324). All but one (n = 1/89, 1%) WNBA were completely occluded vs WEB occlusion rate of 53% at 1 year, statistically significantly worse (p < .001). In our analysis, we were not able to show superiority of WEB in terms of procedural morbidity in comparison to microsurgical clipping, defined as worsening in mRS. Microsurgical clipping achieves statistically significantly higher rates of complete aneurysm occlusion, thus posing the question of whether the WEB should be presented as a viable, comparable alternative to patients amenable to surgical treatment.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Humanos , Aneurisma Intracraniano/terapia , Estudos Retrospectivos , Resultado do Tratamento
3.
Br J Neurosurg ; 34(3): 333-338, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31650871

RESUMO

Purpose: The Neuroform Atlas is a self-expandable and low-profiled stent that is used for aneurysm neck scaffolding and has been recently approved for clinical practice in Korea. We present our initial experiences of endovascular coiling using the Neuroform Atlas stent.Materials and methods: All cerebral aneurysms treated by stent-assisted coiling with a Neuroform atlas stent in two institutions between February and May 2018 were retrospectively evaluated. Fifty-one patients with 55 un-ruptured saccular cerebral aneurysms (mean size: 4.72 ± 1.81 mm, mean neck diameter: 3.82 ± 1.23 mm, mean dome-to-neck ratio: 1.21) were included in our study (40 females, mean age: 59.29 ± 11.96 years). Patient demographics, aneurysm characteristics, initial angiographic post procedural outcomes, and clinical and angiographic follow-up data were analysed.Results: There was one case of procedural failure due to a downward slip during stent deployment. The technical success rate was 98.2% (54/55). A post-procedure control angiogram showed complete occlusion in 27 (50%), residual neck in 16 (29.6%) and residual sac in 11 (20.4%) aneurysms. There were no procedure-related complications. In one case, a symptomatic thromboembolism with left hand grip weakness (grade IV) was observed two days after the procedure and resolved at discharge. The modified Rankin scale score at discharge was 0 in all patients. Angiographic follow-up data at a mean of 4.8 months were available for 51/54 (94.4%) aneurysms. Among them, 27 aneurysms (52.9%) were stable, 20 aneurysms (39.2%) showed progressive occlusion and 4 aneurysms showed an increased modified Raymond Roy occlusion classification score (only one of these patients was included in the recanalization criteria).Conclusion: Our findings suggest the Neuroform Atlas stent can be useful for the coiling of cerebral aneurysms without significant complications regardless of aneurysm location.


Assuntos
Aneurisma Intracraniano , Stents , Idoso , Angiografia Cerebral , Embolização Terapêutica , Feminino , Força da Mão , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Masculino , Pessoa de Meia-Idade , República da Coreia , Estudos Retrospectivos , Resultado do Tratamento
4.
Radiologe ; 60(4): 321-324, 2020 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-32140742

RESUMO

CLINICAL ISSUE: Intracranial aneurysms most commonly occur at bifurcation sites. In case of dealing with broad based aneurysms, the risk of accidental vessel occlusion during embolization should not be underestimated. Therefore, several devices are available, e.g. WEB device and barrelsStent. Besides that, a special technique gives the opportunity to place two stents into each other or next to each other into both branches of a bifurcation. Over 300 patients included in 18 studies were treated with Y­stenting (e.g., Medline/Embase) showing a good clinical outcome in 92%. A complete occlusion was achieved in 91%. The rate of neurologic deficits was 4%, the procedure-caused mortality was 2%. Furthermore, 12% of the patients sustained a stroke during the intervention. Ruptured aneurysm was found in 19%. CONCLUSION: All in all, a high occlusion rate and a low rate of mortality and stroke were shown by using Y­stenting.


Assuntos
Procedimentos Endovasculares/tendências , Aneurisma Intracraniano/terapia , Procedimentos Endovasculares/instrumentação , Humanos , Stents , Resultado do Tratamento
5.
Vasa ; 49(3): 215-224, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31904308

RESUMO

Background: Adverse morphological features of the proximal aortic neck have been identified as culprits for late failure after endovascular aneurysm repair (EVAR). Our objective was to investigate the prognostic role of wide proximal aortic neck in EVAR. Methods: We conducted a review of the literature in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines to identify studies comparing outcomes of EVAR in patients with large versus small proximal aortic neck. A meta-analysis of time-to-event data was performed with the inverse-variance method and the results were reported as summary hazard ratio (HR) and 95 % CI. We applied random-effects models of meta-analysis. Results: We identified 9 observational studies reporting on a total of 7,682 patients (1,961 with large diameter and 5,721 with small diameter neck). The hazard of death (HR 1.57, 95 % CI 1.23-2.01; P = 0.0003), aneurysm-related reintervention (HR 2.06, 95 % CI 1.23-3.45; P = 0.006), type Ia endoleak (HR 6.69, 95 % CI 4.39-10.20; P < 0.001), sac expansion (HR 10.07, 95 % CI 1.80-56.53; P = 0.009), aneurysm rupture (HR 2.96, 95 % CI 2.00-4.38; P < 0.0001), and neck-related adverse events (HR 10.33, 95 % CI 4.95-21.56; P < 0.0001) was higher in patients with large diameter proximal aortic neck than in those with small neck. Conclusions: Patients with a large proximal aortic neck were found to have poorer outcomes than those with small neck. This finding has implications in decision making when selecting methods for aneurysm treatment and in EVAR surveillance for aneurysm-related complications in this cohort of patients.


Assuntos
Aneurisma da Aorta Abdominal , Procedimentos Endovasculares , Prótese Vascular , Endoleak , Humanos , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
J Neuroradiol ; 47(4): 323-327, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30954550

RESUMO

BACKGROUND: Unfavorable aneurysm anatomy can make microwire navigation challenging, increasing the risk of complications. We present our experience of WEB-assisted microcatheterization in complex aneurysms. CLINICAL PRESENTATION: Flow diversion was performed for three wide-neck large/giant intracranial aneurysms. A WEB was placed inside the sac, blocking the aneurysm neck and providing a contact surface to redirect the microwire across the aneurysm. CONCLUSION: WEB-assisted microcatheterization appears an alternative strategy for the treatment of complex aneurysms.


Assuntos
Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/cirurgia , Cirurgia Assistida por Computador/métodos , Cateterismo , Feminino , Humanos , Microcirurgia/métodos , Pessoa de Meia-Idade , Resultado do Tratamento
7.
Neurol Neurochir Pol ; 50(6): 425-431, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27546894

RESUMO

OBJECTIVE: We report our experience with stent-assisted coiling of anterior communicating artery aneurysms with special consideration of angiographic and clinical outcomes, retreatment rate and periprocedural complications. MATERIALS AND METHODS: The analysis included 34 consecutive ruptured and unruptured wide-neck aneurysms. The aneurysm size ranged from 2 to 18mm (mean 5.47). Clinical examinations with the use of modified Rankin Score and angiographic outcomes were evaluated initially post-embolization and at a minimum follow-up of 6 months. RESULTS: Initial post-treatment complete and near-complete aneurysm occlusion was achieved in 32 (94%) and 2 (6%) cases, respectively. Imaging follow-up, performed in 28 (82%) patients, showed no change in the degree of occlusion in 25 (89%) cases and coil compaction in 3 (11%) patients. Of these, one (3.6%) patient underwent a second coil embolization. The periprocedural severe complication rate was 2.9% (1/35) and was associated with prolonged attempt of retrieval of migrated coil resulting in anterior cerebral artery infarct with serious clinical consequences. In another 3 patients periprocedural adverse events without delayed clinical consequences were noticed. The clinical follow-up evaluation achieved in 33 (97%) patients showed no change in 30 (91%) cases, one patient (3%) with clinical improvement and two (6%) cases of neurological deterioration. CONCLUSIONS: The use of stent is feasible and effective for coil embolization of wide-necked anterior communicating artery aneurysms. Although periprocedural complications resulting in severe morbidity are rare, they should be noted, since in terms of thromboembolic events some of them presumably have a potential to be avoidable.


Assuntos
Aneurisma Roto/terapia , Artéria Cerebral Anterior/cirurgia , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/terapia , Stents , Adulto , Idoso , Aneurisma Roto/diagnóstico por imagem , Artéria Cerebral Anterior/diagnóstico por imagem , Angiografia Cerebral , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
8.
Neuroradiol J ; : 19714009241247463, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38621366

RESUMO

BACKGROUND: Wide neck bifurcation aneurysms (WNBAs) are a subtype of aneurysms that are especially complex to treat. We aim to conduct a systematic review and meta-analysis to synthesize the available literature on the safety and efficacy of employing endovascular clip system (eCLIPs) in the treatment of WNBAs. METHODS: We report this study in accordance to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) 2020 guidelines. PubMed, Embase, Web of Science, and Scopus were queried for this review. Screening and extraction were performed by at least two authors to ensure accuracy and completeness, and a senior author arbitrated any discrepancies. All data were analyzed using R software version 4.3.0. and random-effects model. RESULTS: Four studies were finally included, of which three were prospective and one was retrospective. Successful adjunctive coiling occurred in 91.38% (95% CI = 70.71-97.9) of cases and overall technical success was achieved in 88.61% (95 CI = 75.54-95.15) of cases. The pooled complete occlusion (Raymond-Roy Class I) was 50.65% (95% CI = 39.63-61.60) and adequate occlusion (Raymond-Roy Class I/II) was 84.42% (95% CI = 74.53-90.93). Thrombo-embolic complication had a pooled rate of 1.22% (95% CI = 0.17-8.15), retreatment rate was 6.10% (95% CI = 2.56-13.83), and mortality reported in 3.66% (95% CI = 1.18-10.74) of patients. CONCLUSION: The use of eCLIPs may be a safe and efficacious treatment for WNBAs. Future randomized controlled trials are needed for further validation of the findings.

9.
J Clin Med ; 13(14)2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39064207

RESUMO

Flow diversion for intracranial aneurysms emerged as an efficacious and durable treatment option over the last two decades. In a paradigm shift from intrasaccular aneurysm embolization to parent vessel remodeling as the mechanism of action, the proliferation of flow-diverting devices has enabled the treatment of many aneurysms previously considered untreatable. In this review, we review the history and development of flow diverters, highlight the pivotal clinical trials leading to their regulatory approval, review current devices including endoluminal and intrasaccular flow diverters, and discuss current and expanding indications for their use. Areas of clinical equipoise, including ruptured aneurysms and wide-neck bifurcation aneurysms, are summarized with a focus on flow diverters for these pathologies. Finally, we discuss future directions in flow diversion technology including bioresorbable flow diverters, transcriptomics and radiogenomics, and machine learning and artificial intelligence.

10.
Front Neurol ; 15: 1391799, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39099782

RESUMO

Background: Treating wide-neck bifurcated cerebral aneurysms (WNBAs) using various techniques and new devices has shown favorable outcomes. However, endovascular coiling can be technically challenging when the aneurysm neck is incorporated into the parent vessel. Furthermore, although recent research has reported favorable outcomes of Neuroform Atlas stent (NAS)-assisted coiling, broad inclusion criteria have hampered precise evaluations of their effectiveness and safety for treating complex WNBAs. Therefore, this study evaluated whether the use of a single NAS is a safe and effective approach for treating complex WNBAs. Methods: We treated 76 complex WNBAs (unruptured, n = 49; ruptured, n = 27) using single NAS-assisted coil embolization and retrospectively analyzed the clinical and angiographic outcomes. Results: In a cohort of 68 patients (mean age, 58.3 ± 11.6 years; males n = 20, 29.4%; females, n = 48, 70.6%), 76 stents were successfully delivered to the target aneurysms, yielding a technical success rate of 98.6%. Complete occlusion was evident in 59 (77.6%) of 76 aneurysms, with neck remnants found in 16 (21.1%) and partial occlusion in 1 (1.3%). Treatment-related morbidities comprised one branch occlusion and one parenchymal hemorrhage. However, no new neurological symptoms of unruptured aneurysms were evident at discharge. The outcomes of 20 of the 27 ruptured aneurysms were favorable (Glasgow Outcome Scale scores of 4 or 5) at the final follow-up assessment (mean 12.2 [6-29] months), except for one initial subarachnoid hemorrhage. Post-treatment angiography revealed complete occlusion in 89.1%, neck remnants in 7.8%, and incomplete occlusion in 3.1% of the aneurysms. Approximately 88.2% of the patients were assessed at least once by follow-up diagnostic or magnetic resonance angiography (mean, 12.5 ± 4.3 [range, 6-29] months), with five (7.8%) minor and two (3.1%) major recurrences. Conclusion: A single NAS is safe and effective for treating WNBAs incorporated into parent vessels.

11.
Clin Neuroradiol ; 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39023542

RESUMO

BACKGROUND: Stent assisted coiling technique have shown to be an effective and safe endovascular strategy for wide neck bifurcation aneurysms in achieving greater packing, allowing the closure of the aneurysm and preserving the parent arteries, compared to simple coiling. MATERIAL AND METHODS: We conducted a retrospective analysis of 79 patients with cerebral aneurysms treated using 'Y'-configuration double Neuroform® stent-assisted coiling at our center from July 2009 to July 2022. RESULTS: Of the 79 patients, 76% (60/79) were incidental unruptured cerebral aneurysm and 24% were patients treated for aneurysm recanalization of a previous ruptured aneurysm (19/79). The most frequent locations were anterior communicating artery (AComA) 44.3% (35/79) and middle cerebral artery (MCA) 32.9% (26/79). We found a complete and almost complete aneurysm occlusion (Raymond-Roy occlusion classification (RROC) 1 and 2): in 100% (79/79) in the angiography after procedure, in 97.6% (42/43) at the first follow-up at 6-8 months and 100% (57/57) at the first 1-2 years of follow-up. No mortality related to treatment was detected. We registered 2.5% (2/79) major ipsilateral strokes, one due to acute in stent thrombosis (patient had a mRS: 0 in follow up at 90 days) and a spinal anterior artery occlusion (patient had a mRS: 3 in follow up at 90 days). CONCLUSION: The 'Y' stent-assisted coiling technique with double Neuroform® is a safe and effective technique for the treatment of wide-neck bifurcation aneurysms, with high rates of complete occlusion, preserving the permeability of the afferent and efferent arteries and low rate of complications.

12.
Interv Neuroradiol ; : 15910199231226294, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38234203

RESUMO

BACKGROUND: The Woven Endo-Bridge (WEB) device revolutionized the treatment of wide-necked bifurcation aneurysms by intrasaccular flow diversion. The latest advancement is the WEB-17 system, offering greater flexibility with fewer wires, enabling treatment of smaller distal aneurysms using smaller microcatheters than the WEB-21 system. METHODS: We conducted a systematic review following preferred reporting items for systematic reviews and meta-analyses guidelines, analyzing data from seven retrospective cohort studies involving 483 aneurysms treated with the WEB-17 device. Statistical analysis computed pooled prevalence rates and 95% confidence intervals using appropriate models for each outcome and R software version 4.3.1 (R Foundation for Statistical Computing, Vienna, Austria). RESULTS: Technical success was achieved in 475 out of 483 aneurysms treated with the WEB-17 device, with a success rate of 98.34% (95% confidence interval (CI) = 96.72-99.17). Among the successful cases, 4.97% (95% CI = 1.60-14.39) required adjunctive devices. Adequate occlusion, defined as complete occlusion or neck remnants, was observed in 94.41% (95% CI = 88.17-97.46) of cases. Periprocedural complications were infrequent, with thromboembolic complications occurring in 4.93% (95% CI = 3.29-7.30) of cases, hemorrhagic complications in 1.28% (95% CI = 0.58-2.83), and postprocedural neurologic complications in 0.99% (95% CI = 0.31-3.14). Procedure-related morbidity was observed in 1.71% (95% CI = 0.86-3.39) of cases, and there was one procedure-related mortality reported at 0.21% (95% CI = .03-1.50). Mortality unrelated to the procedure occurred in 1% (95% CI = 0.23-4.15). CONCLUSION: Our findings suggest that the WEB-17 device is associated with a high rate of technical success, favorable angiographic outcomes, and a low rate of periprocedural complications. Further research, including prospective trials, is needed to confirm these findings and establish its safety and efficacy definitively.

13.
Neuroradiol J ; : 19714009241247457, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38613671

RESUMO

BACKGROUND: Recurrent intracranial aneurysms present a significant clinical challenge, demanding innovative and effective treatment approaches. The Woven EndoBridge (WEB) device has emerged as a promising endovascular solution for managing these intricate cases. This study aims to assess the safety and efficacy of the WEB device in treating recurrent intracranial aneurysms. METHODS: We conducted a comprehensive search across multiple databases, including PubMed, Scopus, Embase, and Web of Science, from inception to June 5, 2023. Eligible studies focused on evaluating WEB device performance and included a minimum of five patients with recurrent intracranial aneurysms. The complete and adequate occlusion rates, neck remnant rates, and periprocedural complication rates were pooled using SATA V.17. RESULTS: Our analysis included five studies collectively enrolling 73 participants. Participant ages ranged from 52.9 to 65 years, with 64.4% being female. Aneurysms were wide-necked and predominantly located in the middle cerebral artery, basilar artery, and anterior cerebral artery. Previous treatments encompassed coiling, clipping, and the use of WEB devices. Our study found an overall adequate occlusion rate of 0.80 (95% CI 0.71-0.89), a complete occlusion rate of 0.39 (95% CI 0.28-0.50), and a neck remnant rate of 0.38 (95% CI 0.27-0.48). Periprocedural complications were reported at a rate of 0%, although heterogeneity was observed in this data. Notably, evidence of publication bias was identified in the reporting of periprocedural complication rates. CONCLUSION: Our findings suggest that the WEB device is associated with favorable outcomes for treating recurrent wide-neck intracranial aneurysms.

14.
Surg Neurol Int ; 14: 300, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37680930

RESUMO

Background: Endovascular treatment of wide-necked bifurcation aneurysms remains challenging. Although the advent of PulseRider and Web has expanded treatment options, aneurysms with a large deviation from the parent artery axis remains difficult to treat. We present the case of a wide-necked bifurcation aneurysm that was misaligned with the angle between the long axis of the parent artery and the aneurysm and was successfully treated with Y-shaped PulseRider-assisted coil embolization. Case Description: A 64-year-old woman presented with an unruptured basilar tip aneurysm. Cerebral angiography showed a wide-necked aneurysm measuring 8.1 mm × 6.1 mm, neck 5.7 mm. The aneurysm was strongly tilted to the right and posterior relative to the basilar artery, and the bilateral posterior cerebral artery (PCA) and superior cerebellar artery (SCA) diverged from the aneurysm body. PulseRider-assisted coil embolization was performed. A Y-shaped PulseRider was selected to be placed in a hybrid fashion with the right arch in the aneurysm and the left arch in the branch. Adequate coil embolization with preservation of the bilateral PCA and SCA was possible, and cerebral angiography immediately after the treatment showed slight dome filling. Cerebral angiography 6 months after the procedure showed that the embolic status had improved to complete occlusion. Conclusion: For wide-neck bifurcation aneurysms with a misaligned axis, a Y-shaped PulseRider used in a hybrid fashion, in which the leaflet on the side with the tilted axis is placed in the aneurysm, allows the PulseRider to be deployed more closely to the aneurysm, thereby enabling good coil embolization.

15.
World Neurosurg ; 180: 213-223.e7, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37813336

RESUMO

BACKGROUND: Wide-necked bifurcation aneurysms (WNBAs) are challenging intracranial aneurysms. Several device and treatment approaches have been proposed for the treatment of WNBAs. The endovascular clip system (eCLIPs) is a newly developed endovascular device with flow diverter and flow disruptor features. This study aims to investigate the safety and efficacy of the eCLIPs for treatment of patients with WNBAs. METHODS: This is a systematic review and meta-analysis study conducted in accordance with the PRISMA (preferred reporting items for systematic reviews and meta-analyses) guidelines. The electronic databases of PubMed, Embase, Scopus, and Web of Science were systematically reviewed from inception to June 19, 2023. The rate of complete and near-complete occlusion, successful device implantation, and serious adverse events were pooled using STATA, version 17. RESULTS: A total of 5 studies with 110 patients with WNBAs were systematically investigated. Our findings show that the immediate successful implantation rate of eCLIPs was 0.93 (95% confidence interval [CI], 0.88-0.97). Moreover, the immediate postoperative complete occlusion rate was 0.34 (95% CI, 0.10-0.58), and the immediate postoperative near-complete occlusion rate was 0.35 (95% CI, 0.24-0.45). Also, the near-complete occlusion rate at the latest follow-up was 0.3 (95% CI, 0.16-0.44). The serious adverse event rate was 0.14 (95% CI, 0.05-0.22). Stroke was also reported in 2 studies, with 1 study reporting 1 patient who experienced stroke within the first 24 hours and 1 study reporting no patients with stroke. CONCLUSIONS: Our findings document that the eCLIPs is a safe and effective device for treating patients with WNBAs and associated with favorable outcomes.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Acidente Vascular Cerebral , Humanos , Resultado do Tratamento , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Aneurisma Intracraniano/etiologia , Embolização Terapêutica/efeitos adversos , Instrumentos Cirúrgicos , Acidente Vascular Cerebral/etiologia , Estudos Retrospectivos , Stents
16.
Adv Mater ; 35(46): e2305868, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37579579

RESUMO

Ruptured wide-neck aneurysms (WNAs), especially in a setting of coagulopathy, are associated with significant morbidity and mortality. It is shown that by trapping a sub-millimeter clinical catheter inside the aneurysm sac using a flow diverter stent (FDS), instant hemostasis can be achieved by filling the aneurysm sac using a novel biomaterial, rescuing catastrophic bleeding in large-animal models. Multiple formulations of a biomaterial comprising gelatin, nanoclay (NC), and iohexol are developed, optimized, and extensively tested in vitro to select the lead candidate for further testing in vivo in murine, porcine, and canine models of WNAs, including in a subset with aneurysm rupture. The catheter-injectable and X-ray visible versions of the gel embolic agent (GEA) with the optimized mechanical properties outperform control groups, including a subset that receive a clinically used liquid embolic (Onyx, Medtronic), with and without aneurysm rupture. A combinatorial approach to ruptured WNAs with GEA and FDS may change the standard of medical practice and save lives.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Aneurisma Intracraniano , Animais , Cães , Camundongos , Suínos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/complicações , Resultado do Tratamento , Stents , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/terapia , Aneurisma Roto/complicações
17.
Interv Neuroradiol ; : 15910199231182460, 2023 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-37321652

RESUMO

The invested effort and collaboration of clinicians and medical device companies to improve occlusion rates and clinical outcomes for patients with intracranial aneurysms treated via less invasive endovascular means led to the development of the concept of intrasaccular devices. Intrasaccular devices were introduced to offer simple treatment options, offering easier navigation through difficult anatomy, simpler and quicker deployment into large and wide-neck aneurysms. Additionally, they offer easier sizing, whilst offering a wide range of options suitable for aneurysms of different sizes. The concept of most intrasaccular devices is to occupy the aneurysm neck, however offering better stability than simple coiling, therefore increasing the chance of long-term aneurysm occlusion. This is achieved without a sizable metal content within the parent vessel, contrary to flow diverters, theoretically reducing the risk of thromboembolic events. This review aims to discuss the history and latest developments of intrasaccular intracranial devices, which offer an exciting and potentially successful option for treatment of complex intracranial aneurysms.

18.
Neurol Res ; 45(5): 465-471, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36534604

RESUMO

OBJECTIVES: To evaluate the clinical, technical, and angiographic results in endovascular management of wide-neck intracranial aneurysms (WN-IAs) using the balloon-remodeling technique. METHODS: This study was a prospective, single-center study that was carried out over a period of three years from January 2019 to December 2021 at the Neuro-Interventional Unit at our hospital. Patients who presented with WNIAs and were eligible for endovascular treatment using the balloon-remodeling approach were included in the study. RESULTS: We included 37 patients with a mean age of 49.7 ± 12.3 years. About 91.9% of the participants had SAH, 5.4% had unruptured aneurysms, and 2.7% had intracranial hemorrhage. The mean time to treatment was 6.97 ± 7.35 days, the mean aneurysm diameter was 5.7 ± 1.7 mm, and the mean neck diameter was 3.8 ± 1.0 mm. The majority of the patients had a dom-to-neck ratio of less than 2 (89.2%). We have used hyper form balloons in 48.6%, hyper glide in 43.2%, Copernic balloons in 5.4%, and eclipse in 2.7%. According to the Raymond-Roy occlusion classification, 86.5% of the patients had complete obliteration, 10.8% had residual neck, and 2.7% had a residual aneurysm. Almost 91.9% had no complications, 2.7% had ischemia, and 5.4% had mild rupture by wire, treated by 5 min hyperinflation of the balloon till hemorrhage stopped. CONCLUSIONS: Balloon-assisted detachable coiling is an important option in the treatment of WN-IAs. We found that this technique allowed safe and efficient treatment of aneurysms when conventional treatment had failed due to WN. Endovascular coiling using the balloon remodeling technique of wide neck showed a high technical success rate and good short-term clinical outcomes. A good selection of patients with WN-IAs treated by endovascular coiling using balloon remodeling technique and a good selection of materials used help in decreasing the complications.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Adulto , Pessoa de Meia-Idade , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Resultado do Tratamento , Estudos Prospectivos , Estudos Retrospectivos , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Angiografia Cerebral/métodos , Stents
19.
Front Neurol ; 14: 1070847, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36816566

RESUMO

Objective: In the study, we explored the safety and effectiveness of staged stenting strategy for acutely wide-neck ruptured intracranial aneurysms. Methods: Online databases, including PubMed, EMBASE, the Cochrane database, and Web of Science, were retrospectively and systematically searched. The main observation indicators were the procedure-related complication rate, complete occlusion rate, and favorable clinical outcome. Meta-analysis was performed using a random or fixed effect model based on heterogeneity. Results: A total of 5 studies with 143 patients were included. The hemorrhagic complication rate of the initial coiling and staged stenting was 2.8% (4 of 143) and 0, respectively. The ischemic complication rate of the coiling and supplemental stenting was 3.5% (5 of 143) and 2.9% (4 of 139), respectively. There were no deaths due to procedure-related complications in two stages. The aneurysm complete occlusion rate was 25% (95% CI, 0.13-0.03; I2 = 4.4%; P = 0.168) after initial coiling, 54% (95% CI, 0.63-0.64; I2 = 0%; P = 0.872) after staged stenting, and 74% (95% CI, 0.66-0.81; I2 = 56.4%; P = 0.562) at follow-up, respectively. Favorable clinical outcome rate 74% (95% CI, 0.61-0.86; I2 = 50.5%; P = 0.133) after discharge of initial coiling treatment, and 86% (95% CI, 0.80-0.92; I2 = 0; P = 0.410) after discharge from stenting, and 97% (95% CI, 0.93-1.01; I2 = 43.8%; P = 0.130) at follow-up. Conclusion: Staged stenting treatment of wide-neck RIA with coiling in the acute phase followed by delayed regular stent or flow-diverter stent had high aneurysm occlusion rate, favorable clinical outcome rate and low procedure-related complication rate. A more dedicated and well-designed controlled study is warranted for further evaluation of staged stenting treatment compared to SCA in wide-neck RIA.

20.
Interv Neuroradiol ; : 15910199231201544, 2023 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-37697720

RESUMO

PURPOSE: This study is a systematic review about the WEB device and addresses the efficacy and safety of this device for the endovascular treatment of ruptured and unruptured intracranial aneurysms. MATERIAL AND METHODS: This systematic literature review followed PRISMA-P guidelines and included studies published until 2010. PubMed and ScienceDirect databases were searched, resulting in 22 articles meeting the inclusion criteria. RESULTS: The studies involved 1705 patients and 1224 aneurysms, predominantly wide-neck aneurysms in the middle cerebral artery, internal carotid artery, and basilar artery. The treatment success rate was 28.1%, with the WEB-SL and WEB-SLS devices being commonly used. The immediate post-treatment adequate occlusion rate was 33.3%, increasing to 49.7% at follow-up. Thromboembolic complications occurred in 6.5% of cases, while other complications were observed in 3.1% of cases. The mortality rate associated with the WEB device was low, approximately 1%. CONCLUSION: The WEB device demonstrates favorable outcomes in treating patients with intracranial aneurysms, with adequate occlusion rates improving over time. Thromboembolic complications are the primary concern, but overall complication and mortality rates remain low. Further research is needed to optimize device selection, standardize classification systems, and enhance long-term evaluation and training protocols.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA