1.
J Clin Microbiol ; 62(10): e0043424, 2024 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-39297624

RESUMO

The MBT Pathfinder is an automated colony-picking robot designed for efficient sample preparation in matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. This article presents results from three key experiments evaluating the instrument's performance in conjunction with MALDI Biotyper instrument. The method comparison experiment assessed its clinical performance, demonstrating comparable results with gram-positive, gram-negative, and anaerobic bacteria (scores larger than 2.00) and superior performance over simple direct yeast transfer (score: 1.80) when compared to samples prepared manually. The repeatability experiment confirmed consistent performance over multiple days and labs (average log score: 2.12, std. deviation: 0.59). The challenge panel experiment showcased its consistent and accurate performance across various samples and settings, yielding average scores between 1.76 and 2.19. These findings underline the MBT Pathfinder as a reliable and efficient tool for MALDI-TOF mass spectrometry sample preparation in clinical and research applications.


Assuntos
Automação Laboratorial , Bactérias , Robótica , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Humanos , Bactérias/classificação , Bactérias/isolamento & purificação , Automação Laboratorial/métodos , Manejo de Espécimes/métodos , Reprodutibilidade dos Testes
2.
J Clin Microbiol ; 62(8): e0047624, 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39007562

RESUMO

Using sequential immunoassays for the screening of blood donors is well described for viral serology testing but not for the screening of syphilis. In this study, we report the evaluation results and 2-year sequential testing data using two highly sensitive automated serology assays, the Alinity s Syphilis chemiluminescent immunoassay for screening, with all repeatedly reactive samples then tested on the Elecsys Syphilis electrochemiluminescence immunoassay. We screened 1,767,782 blood donor samples between 7 July 2021 and 6 July 2023 and found the Alinity false-positive rate to be low at 0.08% (1,456/1,767,782). The common false-positive rate between the two assays was also low (3.83%, 58/1,514). Concordantly reactive samples were further tested using a Treponema pallidum particle agglutination test, a rapid plasma reagin test, and a fluorescent treponemal antibody absorption test. There were 262/1,376 concordantly reactive Alinity and Elecsys blood donor samples with reactivity on one or more of the confirmatory tests. A total of 26/1,376 donors had a current syphilis infection, 152/1,376 reported a past history of syphilis and had been treated, and 84/1,376 did not report a past history of syphilis. We suggest that future studies could explore the use of sequential immunoassays to aid in the serodiagnosis for syphilis. IMPORTANCE: The serodiagnosis for syphilis usually follows two methodologies-a "traditional" algorithm using a non-treponemal test followed by confirmation using a treponemal test, or a "reverse" algorithm using a treponemal test followed by a non-treponemal test. There are limited reports in the literature of using a modified reverse algorithm (treponemal test followed by a second treponemal test), and to the best of knowledge, there are currently no published articles using two highly sensitive automated immunoassays to aid the serodiagnosis of syphilis. In addition, the Treponema pallidum particle agglutination (TPPA) assay is commonly used as a confirmatory test for the diagnosis of syphilis. With the withdrawal of the TPPA assay from Australia and presumably from the global market also, alternative testing algorithms are now required. This study provides proof of concept for using sequential immunoassays in the diagnosis of syphilis.


Assuntos
Doadores de Sangue , Sorodiagnóstico da Sífilis , Sífilis , Treponema pallidum , Humanos , Sífilis/diagnóstico , Sífilis/sangue , Imunoensaio/métodos , Sorodiagnóstico da Sífilis/métodos , Treponema pallidum/imunologia , Programas de Rastreamento/métodos , Anticorpos Antibacterianos/sangue , Reações Falso-Positivas , Automação Laboratorial/métodos , Sensibilidade e Especificidade , Feminino , Masculino
3.
J Clin Microbiol ; 62(5): e0144523, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38557148

RESUMO

The virulence of methicillin-resistant Staphylococcus aureus (MRSA) and its potentially fatal outcome necessitate rapid and accurate detection of patients colonized with MRSA in healthcare settings. Using the BD Kiestra Total Lab Automation (TLA) System in conjunction with the MRSA Application (MRSA App), an imaging application that uses artificial intelligence to interpret colorimetric information (mauve-colored colonies) indicative of MRSA pathogen presence on CHROMagar chromogenic media, anterior nares specimens from three sites were evaluated for the presence of mauve-colored colonies. Results obtained with the MRSA App were compared to manual reading of agar plate images by proficient laboratory technologists. Of 1,593 specimens evaluated, 1,545 (96.98%) were concordant between MRSA App and laboratory technologist reading for the detection of MRSA growth [sensitivity 98.15% (95% CI, 96.03, 99.32) and specificity 96.69% (95% CI, 95.55, 97.60)]. This multi-site study is the first evaluation of the MRSA App in conjunction with the BD Kiestra TLA System. Using the MRSA App, our results showed 98.15% sensitivity and 96.69% specificity for the detection of MRSA from anterior nares specimens. The MRSA App, used in conjunction with laboratory automation, provides an opportunity to improve laboratory efficiency by reducing laboratory technologists' labor associated with the review and interpretation of cultures.


Assuntos
Automação Laboratorial , Técnicas Bacteriológicas , Staphylococcus aureus Resistente à Meticilina , Sensibilidade e Especificidade , Infecções Estafilocócicas , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Humanos , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/microbiologia , Automação Laboratorial/métodos , Técnicas Bacteriológicas/métodos , Automação/métodos , Colorimetria/métodos , Inteligência Artificial
4.
J Clin Microbiol ; 62(5): e0165123, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38572970

RESUMO

In clinical bacteriology laboratories, reading and processing of sterile plates remain a significant part of the routine workload (30%-40% of the plates). Here, an algorithm was developed for bacterial growth detection starting with any type of specimens and using the most common media in bacteriology. The growth prediction performance of the algorithm for automatic processing of sterile plates was evaluated not only at 18-24 h and 48 h but also at earlier timepoints toward the development of an early growth monitoring system. A total of 3,844 plates inoculated with representative clinical specimens were used. The plates were imaged 15 times, and two different microbiologists read the images randomly and independently, creating 99,944 human ground truths. The algorithm was able, at 48 h, to discriminate growth from no growth with a sensitivity of 99.80% (five false-negative [FN] plates out of 3,844) and a specificity of 91.97%. At 24 h, sensitivity and specificity reached 99.08% and 93.37%, respectively. Interestingly, during human truth reading, growth was reported as early as 4 h, while at 6 h, half of the positive plates were already showing some growth. In this context, automated early growth monitoring in case of normally sterile samples is envisioned to provide added value to the microbiologists, enabling them to prioritize reading and to communicate early detection of bacterial growth to the clinicians.


Assuntos
Inteligência Artificial , Bactérias , Sensibilidade e Especificidade , Humanos , Bactérias/crescimento & desenvolvimento , Bactérias/isolamento & purificação , Bactérias/classificação , Algoritmos , Técnicas Bacteriológicas/métodos , Processamento de Imagem Assistida por Computador/métodos , Infecções Bacterianas/diagnóstico , Infecções Bacterianas/microbiologia , Bacteriologia , Automação Laboratorial/métodos , Meios de Cultura/química
5.
J Clin Microbiol ; 62(5): e0002824, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38639489

RESUMO

The mpox outbreak, caused by monkeypox virus (MPXV), accelerated the development of molecular diagnostics. In this study, we detail the evaluation of the Research Use Only (RUO) NeuMoDx MPXV assay by multiple European and US sites. The assay was designed and developed by Qiagen for the NeuMoDx Molecular Systems. Primers and probes were tested for specificity and inclusivity in silico. The analytical sensitivity of the assay was determined by testing dilutions of synthetic and genomic MPXV DNA. A total of 296 clinical samples were tested by three sites; the Johns Hopkins University (US), UZ Gent (Belgium, Europe), and Hospital Universitario San Cecilio (Spain, Europe). The analytical sensitivity of the assay was 50 copies/mL for both clades I and II. The assay showed 100% in silico identity for 80 clade I and 99.98% in silico identity for 5,162 clade II genomes. Clade II primers and probes showed 100% in silico specificity; however, identity of at least one of the two sets of clade I primers and probes with variola, cowpox, camelpox, and vaccinia viruses was noticed. The clinical validation showed sensitivity of 99.21% [95% confidence interval (CI): 95.66-99.98%] and specificity of 96.64% (95% CI: 91.62-99.08%) for lesion swab samples. The NeuMoDx MPXV Test shows acceptable analytical and clinical performance. The assay improves the laboratory's workflow as it consolidates nucleic acid extraction, PCR, data analysis, and interpretation and can be interfaced. The Test Strip can differentiate clades I and II, which has important laboratory safety implications. IMPORTANCE: In this manuscript, we provide detailed in silico analysis and clinical evaluation of the assay using a large cohort of clinical samples across three academic centers in Europe and the United States. Because the assay differentiates MPXV clades I and II, this manuscript is timely due to the current need to rule out the regulated clade I by diagnostic clinical laboratories. In December 2023, and due to first report of cases of sexually transmitted clade I infections in the Democratic Republic of the Congo, when generic assays that do not differentiate the clades are used, samples are considered regulated. The assay meets the need of full automation and has a marked positive impact on the laboratory workflow.


Assuntos
Técnicas de Diagnóstico Molecular , Monkeypox virus , Mpox , Reação em Cadeia da Polimerase em Tempo Real , Sensibilidade e Especificidade , Humanos , Monkeypox virus/genética , Monkeypox virus/isolamento & purificação , Monkeypox virus/classificação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Mpox/diagnóstico , Mpox/virologia , Técnicas de Diagnóstico Molecular/métodos , Europa (Continente) , Estados Unidos , Automação Laboratorial/métodos , Primers do DNA/genética , Bélgica
6.
J Clin Microbiol ; 62(5): e0174923, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38624235

RESUMO

The timely identification of microbial pathogens is essential to guide targeted antimicrobial therapy and ultimately, successful treatment of an infection. However, the yield of standard microbiology testing (SMT) is directly related to the duration of antecedent antimicrobial therapy as SMT culture methods are dependent on the recovery of viable organisms, the fastidious nature of certain pathogens, and other pre-analytic factors. In the last decade, metagenomic next-generation sequencing (mNGS) has been successfully utilized as a diagnostic tool for various applications within the clinical laboratory. However, mNGS is resource, time, and labor-intensive-requiring extensive laborious preliminary benchwork, followed by complex bioinformatic analysis. We aimed to address these shortcomings by developing a largely Automated targeted Metagenomic next-generation sequencing (tmNGS) PipeLine for rapId inFectIous disEase Diagnosis (AMPLIFIED) to detect bacteria and fungi directly from clinical specimens. Therefore, AMPLIFIED may serve as an adjunctive approach to complement SMT. This tmNGS pipeline requires less than 1 hour of hands-on time before sequencing and less than 2 hours of total processing time, including bioinformatic analysis. We performed tmNGS on 50 clinical specimens with concomitant cultures to assess feasibility and performance in the hospital laboratory. Of the 50 specimens, 34 (68%) were from true clinical infections. Specimens from cases of true infection were more often tmNGS positive compared to those from the non-infected group (82.4% vs 43.8%, respectively, P = 0.0087). Overall, the clinical sensitivity of AMPLIFIED was 54.6% with 85.7% specificity, equating to 70.6% and 75% negative and positive predictive values, respectively. AMPLIFIED represents a rapid supplementary approach to SMT; the typical time from specimen receipt to identification of potential pathogens by AMPLIFIED is roughly 24 hours which is markedly faster than the days, weeks, and months required to recover bacterial, fungal, and mycobacterial pathogens by culture, respectively. IMPORTANCE: To our knowledge, this represents the first application of an automated sequencing and bioinformatics pipeline in an exclusively pediatric population. Next-generation sequencing is time-consuming, labor-intensive, and requires experienced personnel; perhaps contributing to hesitancy among clinical laboratories to adopt such a test. Here, we report a strong case for use by removing these barriers through near-total automation of our sequencing pipeline.


Assuntos
Bactérias , Infecções Bacterianas , Fungos , Sequenciamento de Nucleotídeos em Larga Escala , Metagenômica , Micoses , Humanos , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Fungos/genética , Fungos/isolamento & purificação , Fungos/classificação , Bactérias/genética , Bactérias/isolamento & purificação , Bactérias/classificação , Infecções Bacterianas/diagnóstico , Infecções Bacterianas/microbiologia , Metagenômica/métodos , Micoses/diagnóstico , Micoses/microbiologia , Automação Laboratorial/métodos , Sensibilidade e Especificidade , Técnicas de Diagnóstico Molecular/métodos , Fatores de Tempo , Biologia Computacional/métodos , Masculino , Feminino , Criança , Adolescente , Adulto , Pré-Escolar
7.
Anal Bioanal Chem ; 416(26): 5827-5839, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39207494

RESUMO

Commercial automation systems for small- and medium-sized laboratories, including research environments, are often complex to use. For liquid handling systems (LHS), development is required not only for the robot's movements but also for adapting the bioanalytical method to the automated system. This study investigates whether a more human-like automation strategy-using a robotic system (RS)-is more suitable for research laboratories than a professional automation approach utilizing a commercial automated LHS. We conducted a series of measurements for protein determination using a Bradford assay manually, with a fully automated LHS, and with our human-like RS. Although the hand-like RS approach requires more than twice the time of the LHS, it achieved the best standard deviation in this setup (RS = 0.5, manual = 0.71, LHS = 0.86). Due to the low limit of detection (LOD) and limit of quantification (LOQ), most protein samples could be quantified with the RS (samples below LOQ = 9.7%, LOD = 0.23; LOQ = 0.25) compared to manual (samples below LOQ = 28.8%, LOD = 0.24; LOQ = 0.26) and the LHS (samples below LOQ = 36.1%, LOD = 0.27; LOQ = 0.31). In another time-dependent enzymatic assay test, the RS achieved results comparable to the manual method and the LHS, although the required time could be a constraint for short incubation times. Our results demonstrate that a more hand-like automation system closely models the manual process, leading easier to accurate bioanalytical results. We conclude that such a system could be more suitable for typical research environments than a complex LHS.


Assuntos
Automação , Robótica , Robótica/instrumentação , Limite de Detecção , Automação Laboratorial/métodos , Automação Laboratorial/instrumentação , Humanos , Proteínas/análise
8.
J Clin Lab Anal ; 38(8): e25037, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38619294

RESUMO

BACKGROUND: In newborns, elevated nucleated red blood cell (NRBC) levels can be associated with enhanced erythropoietic stress and might be predictive for adverse outcome. Also, the presence of NRBC in peripheral blood might lead to erroneous enumeration results of white blood cells in automated hematology analyzers. We aimed to assess the comparability of the Sysmex XN 1000 to manual slide reviews and correlation of NRBC with inflammation markers. METHODS: Specimens of 3397 children under 1 year were compared by automated and microscopic NRBC enumeration. Additionally, potential correlations between NRBC and age and inflammation markers were examined. RESULTS: Overall, there was good correlation (r = 0.97) between automated (range: 0%-3883%) and microscopic enumeration (range: 0%-3694%) of NRBC with high comparability up to a NRBC value of 200% and an increase in the variation between the two methods with increasing NRBC numbers. When 94 samples with ≤ 200% NRBC and ≥ 30% divergence between methods were separately reanalyzed with respect to overlapping cell populations in their scattergrams, Sysmex would have generated unrecognized incorrect automated results in 47 samples, corresponding to 1.4% of total study samples. NRBC counts were negatively correlated to age, but not to inflammation markers. CONCLUSION: Sysmex XN 1000 is highly precise in the enumeration of NRBC in children under 1 year up to counts of 200% and might replace time-intense manual counting in routine diagnostics. In the setting of neonatal and intensive care diagnostics, microscopic control and supervision of scattergrams are highly recommended for any automated NRBC enumeration processes.


Assuntos
Eritroblastos , Humanos , Lactente , Eritroblastos/citologia , Recém-Nascido , Contagem de Eritrócitos/métodos , Feminino , Masculino , Automação Laboratorial/métodos , Microscopia/métodos
9.
Stud Hist Philos Sci ; 106: 109-117, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38936271

RESUMO

In the second half of the 20th century, neuroscientists across North America developed automated systems for use in their research laboratories. Their decisions to do so were complex and contingent, partly a result of global reasons, such as the need to increase efficiency and flexibility, and partly a result of local reasons, such as the need to amend perceived biases of earlier research methodologies. Automated methods were advancements but raised several challenges. Transferring a system from one location to another required that certain components of the system be standardized, such as the hardware, software, and programming language. This proved difficult as commercial manufacturers lacked incentives to create standardized products for the few neuroscientists working towards automation. Additionally, investing in automated systems required massive amounts of time, labor, funding, and computer expertise. Moreover, neuroscientists did not agree on the value of automation. My brief history investigates Karl Pribram's decisions to expand his newly created automated system by standardizing equipment, programming, and protocols. Although he was an eminent Stanford neuroscientist with strong institutional support and computer know-how, the development and transfer of his automated behavioral testing system was riddled with challenges. For Pribram and neuroscience more generally, automation was not so automatic.


Assuntos
Neurociências , Neurociências/métodos , Neurociências/história , Neurociências/instrumentação , História do Século XX , Automação/métodos , Automação/instrumentação , Automação Laboratorial/instrumentação , Automação Laboratorial/métodos , Automação Laboratorial/história , América do Norte
10.
Biomed Chromatogr ; 37(8): e5633, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36974028

RESUMO

Currently, primarily urine, whole blood and serum samples are analyzed for doping-relevant substances in professional sports, but recently dried blood spots (DBS) have been introduced as complementary matrix, offering advantageous features, e.g. a minimally invasive sampling procedure. In order to cope with the increased application of DBS, a comprehensive initial testing procedure (ITP) was developed, optimized and validated, comprising a total of 233 substances representing all groups on the World Anti-Doping Agency's (WADA's) Prohibited List. The sample preparation was conducted by employing a fully automated system using an efficient flow-through extraction of a 4 mm diameter spot followed by LC-HRMS/MS analysis. The procedure was successfully validated in terms of selectivity, limit of detection, reproducibility, carryover and robustness with respect to an alternative manual sample preparation, an alternative dried blood collection device and the sample extract stability, and was thus found to meet the required criteria of the relevant guidelines published by WADA for routine application. As a proof-of-concept, DBS samples were analyzed after the administration of the glucocorticoids prednisone and dexamethasone, as well as the stimulant pseudoephedrine and the beta-blocker propranolol. All substances were detected in post-administration samples for at least 4 h and up to 24 h after intake, depending on the collection time period, using the developed testing procedure. In particular, for substances that are only banned in-competition, data obtained from DBS samples can be useful for the interpretation of adverse analytical findings. In conclusion, the developed ITP accounts for the anticipated increasing relevance of DBS in anti-doping analysis in the future and provides a foundation for optimized approaches for specific substance classes.


Assuntos
Dopagem Esportivo , Humanos , Teste em Amostras de Sangue Seco/métodos , Automação Laboratorial/métodos , Manejo de Espécimes , Reprodutibilidade dos Testes
11.
Biotechnol Bioeng ; 119(1): 59-71, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34596238

RESUMO

Developing media to sustain cell growth and production is an essential and ongoing activity in bioprocess development. Modifications to media can often address host or product-specific challenges, such as low productivity or poor product quality. For other applications, systematic design of new media can facilitate the adoption of new industrially relevant alternative hosts. Despite manifold existing methods, common approaches for optimization often remain time and labor-intensive. We present here a novel approach to conventional media blending that leverages stable, simple, concentrated stock solutions to enable rapid improvement of measurable phenotypes of interest. We applied this modular methodology to generate high-performing media for two phenotypes of interest: biomass accumulation and heterologous protein production, using high-throughput, milliliter-scale batch fermentations of Pichia pastoris as a model system. In addition to these examples, we also created a flexible open-source package for modular blending automation on a low-cost liquid handling system to facilitate wide use of this method. Our modular blending method enables rapid, flexible media development, requiring minimal labor investment and prior knowledge of the host organism, and should enable developing improved media for other hosts and phenotypes of interest.


Assuntos
Automação Laboratorial/métodos , Reatores Biológicos , Meios de Cultura , Fermentação/fisiologia , Biomassa , Meios de Cultura/análise , Meios de Cultura/química , Meios de Cultura/metabolismo , Pichia/genética , Pichia/metabolismo
12.
J Pharmacol Exp Ther ; 377(1): 133-145, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33468642

RESUMO

Human taste threshold measurements often are used to infer tastant receptor functionality. However, taste thresholds can be influenced by receptor-independent variables. Examination of the full range of taste-active concentrations by taste discrimination has been hampered by logistics of testing multiple concentrations in replicate with human subjects. We developed an automated rapid throughput operant methodology for taste discrimination and applied it to concentration-response analysis of human taste. Tastant solutions (200 µl) drawn from a 96-well plate and self-administered to the tongue served as discriminative stimuli for money-reinforced responses on a touch-sensitive display. Robust concentration-response functions for "basic taste" stimuli were established, with particular focus on agonists of the taste 1 receptor member 2-taste 1 receptor member 3 heterodimer receptor (TAS1R2/R3). With a training cue of 100 mM sucrose, EC50 values of 56, 79, and 310 µM and 40 mM were obtained for rebaudioside A, sucralose, acesulfame potassium, and sucrose, respectively. Changing the sucrose training cue to 300 mM had no impact, but changing to 30 mM resulted in slight leftward shifts in potencies. A signal detection method also was used to determine values of d', a probabilistic value for discriminability, which indicated that 5 mM was near the limits of detection for sucrose. With repeated testing, both EC50 values and 5 mM sucrose d' values were established for each individual subject. The results showed little correspondence between threshold sensitivities and EC50 values for sucrose. We conclude that concentration-response analysis of taste discrimination provides a more reliable means of inferring receptor function than measurement of discriminability at the lowest detectable tastant concentrations. SIGNIFICANCE STATEMENT: Many inferences about human tastant receptor functionality have been made from taste threshold measurements, which can be influenced by variables unrelated to receptors. We herein report a new methodology that enables rigorous concentration-response analysis of human taste discrimination and its use toward quantitative characterization of tastant agonist activity. Our data suggest that taste discrimination concentration-response functions are a more reliable reflection of underlying receptor activity than threshold measures obtained at the lowest detectable tastant concentrations.


Assuntos
Discriminação Psicológica , Ensaios de Triagem em Larga Escala/métodos , Limiar Gustativo , Adulto , Automação Laboratorial/instrumentação , Automação Laboratorial/métodos , Relação Dose-Resposta a Droga , Feminino , Ensaios de Triagem em Larga Escala/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Receptores Acoplados a Proteínas G/metabolismo , Sacarose/farmacologia , Percepção Gustatória , Língua/efeitos dos fármacos , Língua/metabolismo , Língua/fisiologia
13.
Mod Pathol ; 34(9): 1780-1794, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34017063

RESUMO

The use of immunohistochemistry in the reporting of prostate biopsies is an important adjunct when the diagnosis is not definite on haematoxylin and eosin (H&E) morphology alone. The process is however inherently inefficient with delays while waiting for pathologist review to make the request and duplicated effort reviewing a case more than once. In this study, we aimed to capture the workflow implications of immunohistochemistry requests and demonstrate a novel artificial intelligence tool to identify cases in which immunohistochemistry (IHC) is required and generate an automated request. We conducted audits of the workflow for prostate biopsies in order to understand the potential implications of automated immunohistochemistry requesting and collected prospective cases to train a deep neural network algorithm to detect tissue regions that presented ambiguous morphology on whole slide images. These ambiguous foci were selected on the basis of the pathologist requesting immunohistochemistry to aid diagnosis. A gradient boosted trees classifier was then used to make a slide-level prediction based on the outputs of the neural network prediction. The algorithm was trained on annotations of 219 immunohistochemistry-requested and 80 control images, and tested by threefold cross-validation. Validation was conducted on a separate validation dataset of 222 images. Non IHC-requested cases were diagnosed in 17.9 min on average, while IHC-requested cases took 33.4 min over multiple reporting sessions. We estimated 11 min could be saved on average per case by automated IHC requesting, by removing duplication of effort. The tool attained 99% accuracy and 0.99 Area Under the Curve (AUC) on the test data. In the validation, the average agreement with pathologists was 0.81, with a mean AUC of 0.80. We demonstrate the proof-of-principle that an AI tool making automated immunohistochemistry requests could create a significantly leaner workflow and result in pathologist time savings.


Assuntos
Aprendizado Profundo , Interpretação de Imagem Assistida por Computador/métodos , Imuno-Histoquímica , Patologia Clínica/métodos , Neoplasias da Próstata/diagnóstico , Automação Laboratorial/métodos , Biópsia , Humanos , Masculino , Fluxo de Trabalho
14.
Microb Cell Fact ; 20(1): 184, 2021 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-34556155

RESUMO

BACKGROUND: Microorganisms can be metabolically engineered to produce a wide range of commercially important chemicals. Advancements in computational strategies for strain design and synthetic biological techniques to construct the designed strains have facilitated the generation of large libraries of potential candidates for chemical production. Consequently, there is a need for high-throughput laboratory scale techniques to characterize and screen these candidates to select strains for further investigation in large scale fermentation processes. Several small-scale fermentation techniques, in conjunction with laboratory automation have enhanced the throughput of enzyme and strain phenotyping experiments. However, such high throughput experimentation typically entails large operational costs and generate massive amounts of laboratory plastic waste. RESULTS: In this work, we develop an eco-friendly automation workflow that effectively calibrates and decontaminates fixed-tip liquid handling systems to reduce tip waste. We also investigate inexpensive methods to establish anaerobic conditions in microplates for high-throughput anaerobic phenotyping. To validate our phenotyping platform, we perform two case studies-an anaerobic enzyme screen, and a microbial phenotypic screen. We used our automation platform to investigate conditions under which several strains of E. coli exhibit the same phenotypes in 0.5 L bioreactors and in our scaled-down fermentation platform. We also propose the use of dimensionality reduction through t-distributed stochastic neighbours embedding (t-SNE) in conjunction with our phenotyping platform to effectively cluster similarly performing strains at the bioreactor scale. CONCLUSIONS: Fixed-tip liquid handling systems can significantly reduce the amount of plastic waste generated in biological laboratories and our decontamination and calibration protocols could facilitate the widespread adoption of such systems. Further, the use of t-SNE in conjunction with our automation platform could serve as an effective scale-down model for bioreactor fermentations. Finally, by integrating an in-house data-analysis pipeline, we were able to accelerate the 'test' phase of the design-build-test-learn cycle of metabolic engineering.


Assuntos
Automação Laboratorial/métodos , Escherichia coli/metabolismo , Fermentação , Engenharia Metabólica/instrumentação , Engenharia Metabólica/métodos , Anaerobiose , Escherichia coli/genética , Ensaios de Triagem em Larga Escala/instrumentação , Ensaios de Triagem em Larga Escala/métodos
15.
Mycoses ; 64(3): 245-251, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33174310

RESUMO

BACKGROUND: Light microscopy to study the infection of fungi in skin specimens is time-consuming and requires automation. OBJECTIVE: We aimed to design and explore the application of an automated microscope for fungal detection in skin specimens. METHODS: An automated microscope was designed, and a deep learning model was selected. Skin, nail and hair samples were collected. The sensitivity and the specificity of the automated microscope for fungal detection were calculated by taking the results of human inspectors as the gold standard. RESULTS: An automated microscope was built, and an image processing model based on the ResNet-50 was trained. A total of 292 samples were collected including 236 skin samples, 50 nail samples and six hair samples. The sensitivities of the automated microscope for fungal detection in skin, nails and hair were 99.5%, 95.2% and 60%, respectively, and the specificities were 91.4%, 100% and 100%, respectively. CONCLUSION: The automated microscope we developed is as skilful as human inspectors for fungal detection in skin and nail samples; however, its performance in hair samples needs to be improved.


Assuntos
Automação Laboratorial/instrumentação , Automação Laboratorial/métodos , Aprendizado Profundo , Fungos/citologia , Microscopia/métodos , Pele/microbiologia , Cabelo/microbiologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Microscopia de Fluorescência , Unhas/microbiologia , Sensibilidade e Especificidade
16.
J Clin Lab Anal ; 35(1): e23586, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32969530

RESUMO

BACKGROUND: Automated flow cytometry-based urine analyzer is increasingly being used to identify and enumerate cells and particles in urine specimens. It measures electrical conductivity which could be transformed to osmolality. Using this machine, all urine specimens could be screened for osmolality without requiring a separate dedicated device. We evaluated the performance of the new instrument, the UF-5000 (Sysmex Corporation), in the measurement of urine osmolality. METHODS: The precision of urine osmolality measurement by the UF-5000 was evaluated for 20 days and 4 times a day for 2 concentrations. The linearity and detection capability were evaluated according to the Clinical and Laboratory Standards Institute guidelines. For comparison, 270 random urine specimens from patients were tested simultaneously using the UF5000 and the OsmoPro micro-osmometer (Advanced instruments). RESULTS: The laboratory-based coefficient variations were less than 5%. Urine osmolality using the UF-5000 has a verified linear range (y = 1.097x + 16.91, R2  = .997). Within the comparison analysis, the mean difference was not large (-7.72%) but each differences were largely dispersed with 95% limits of agreement (LoA) from -70.5 to 55.06%, and the mean absolute difference -28.3 mOsm/kg with 95% LoA from -295.13 to 238.45 mOsm/kg. Cohen's kappa value was 0.54 (95% CI, 0.45-0.63). CONCLUSIONS: The UF-5000 measured conductivity and generated an acceptable quantitative analysis of urine osmolality. When compared with the results of the freezing point depression method used by the OsmoPro, a percentage of the measured urine osmolality by the UF-5000 was outside the allowable limit.


Assuntos
Automação Laboratorial , Citometria de Fluxo , Urinálise , Automação Laboratorial/métodos , Automação Laboratorial/normas , Condutividade Elétrica , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Humanos , Concentração Osmolar , Urinálise/métodos , Urinálise/normas , Urina/química , Urina/citologia
17.
Int J Mol Sci ; 22(17)2021 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-34502110

RESUMO

Aptamers feature a number of advantages, compared to antibodies. However, their application has been limited so far, mainly because of the complex selection process. 'High-throughput sequencing fluorescent ligand interaction profiling' (HiTS-FLIP) significantly increases the selection efficiency and is consequently a very powerful and versatile technology for the selection of high-performance aptamers. It is the first experiment to allow the direct and quantitative measurement of the affinity and specificity of millions of aptamers simultaneously by harnessing the potential of optical next-generation sequencing platforms to perform fluorescence-based binding assays on the clusters displayed on the flow cells and determining their sequence and position in regular high-throughput sequencing. Many variants of the experiment have been developed that allow automation and in situ conversion of DNA clusters into base-modified DNA, RNA, peptides, and even proteins. In addition, the information from mutational assays, performed with HiTS-FLIP, provides deep insights into the relationship between the sequence, structure, and function of aptamers. This enables a detailed understanding of the sequence-specific rules that determine affinity, and thus, supports the evolution of aptamers. Current variants of the HiTS-FLIP experiment and its application in the field of aptamer selection, characterisation, and optimisation are presented in this review.


Assuntos
Aptâmeros de Nucleotídeos/química , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Análise de Sequência de DNA/métodos , Automação Laboratorial/instrumentação , Automação Laboratorial/métodos , Sequenciamento de Nucleotídeos em Larga Escala/instrumentação , Mutagênese , Dispositivos Ópticos , Análise de Sequência de DNA/instrumentação
18.
Int J Mol Sci ; 22(3)2021 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-33498248

RESUMO

Hereditary factor XIII (FXIII) deficiency is a rare autosomal bleeding disorder which can cause life-threatening bleeding. Acquired deficiency can be immune-mediated or due to increased consumption or reduced synthesis. The most commonly used screening test is insensitive, and widely used quantitative assays have analytical limitations. The present study sought to validate Technofluor FXIII Activity, the first isopeptidase-based assay available on a routine coagulation analyser, the Ceveron s100. Linearity was evidenced throughout the measuring range, with correlation coefficients of >0.99, and coefficients of variation for repeatability and reproducibility were <5% and <10%, respectively. A normally distributed reference range of 47.0-135.5 IU/dL was derived from 154 normal donors. Clinical samples with Technofluor FXIII Activity results between 0 and 167.0 IU/dL were assayed with Berichrom® FXIII Activity, a functional ammonia release assay, and the HemosIL™ FXIII antigen assay, generating correlations of 0.950 and 0.980, respectively. Experiments with a transglutaminase inhibitor showed that Technofluor FXIII Activity can detect inhibition of enzymatic activity. No interference was exhibited by high levels of haemolysis and lipaemia, and interference by bilirubin was evident at 18 mg/dL, a level commensurate with severe liver disease. Technofluor FXIII Activity is a rapid, accurate and precise assay suitable for routine diagnostic use with fewer interferents than ammonia release FXIII activity assays.


Assuntos
Automação Laboratorial/métodos , Testes de Coagulação Sanguínea/métodos , Carbono-Nitrogênio Liases/metabolismo , Deficiência do Fator XIII/diagnóstico , Fator XIII/análise , Corantes Fluorescentes/normas , Automação Laboratorial/normas , Bilirrubina/metabolismo , Testes de Coagulação Sanguínea/normas , Compostos Cromogênicos/normas , Fator XIII/metabolismo , Deficiência do Fator XIII/sangue , Fluorometria/métodos , Fluorometria/normas , Hemólise , Humanos , Testes Imunológicos/métodos , Testes Imunológicos/normas , Reprodutibilidade dos Testes , Transglutaminases/metabolismo
19.
Molecules ; 26(18)2021 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-34577009

RESUMO

A fully automated sequential injection system was tested in terms of its application in liberation testing, and capabilities and limitations were discussed for clotrimazole liberation from three semisolid formulations. An evaluation based on kinetic profiles obtained in short and longer sampling intervals and steady-state flux values were applied as traditional methods. The obtained clotrimazole liberation profile was faster in the case of Delcore and slower for Clotrimazol AL and Canesten cream commercial formulations. The steady-state flux values for the tested formulations were 52 µg cm-2 h-1 for Canesten, 35 µg cm-2 h-1 for Clotrimazol AL, and 7.2 µg cm-2 h-1 for Delcore measured in 4 min sampling intervals. A simplified approach for the evaluation of the initial rate based on the gradient between the second and third sampling points was used for the first time and was found to correspond well with the results of the conventional methods. A comparison based on the ratio of the steady-state flux and the initial rate values for Canesten and Clotrimazol AL proved the similarity of the obtained results. The proposed alternative was successfully implemented for the comparison of short-term kinetic profiles. Consequently, a faster and simpler approach for dissolution/liberation testing can be used.


Assuntos
Antifúngicos/análise , Automação Laboratorial/métodos , Clotrimazol/análise , Análise de Injeção de Fluxo/métodos , Composição de Medicamentos , Liberação Controlada de Fármacos , Cinética , Creme para a Pele
20.
Gut ; 69(6): 1116-1126, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31563875

RESUMO

OBJECTIVE: Fibrosis stage is strongly associated with liver-related outcomes and is a key surrogate endpoint in drug trials for non-alcoholic steatohepatitis. Dual-photon microscopy allows automated quantification of fibrosis-related parameters (q-FPs) and may facilitate large-scale histological studies. We aim to validate the performance of q-FPs in a large histological cohort. DESIGN: 344 patients with non-alcoholic fatty liver disease (NAFLD) underwent 428 liver biopsies (240 had paired transient elastography examination). Fibrosis stage was scored using the NASH Clinical Research Network system, and q-FPs were measured by dual-photon microscopy using unstained slides. Patients were randomly assigned to the training and validation cohorts to test the performance of individual q-FPs and derive optimal cut-offs. RESULTS: Over 25 q-FPs had area under the receiver-operating characteristics curves >0.90 for different fibrosis stages. Among them, the perimeter of collagen fibres and number of long collagen fibres had the highest accuracy. At the best cut-offs, the two q-FPs had 88.3%-96.2% sensitivity and 78.1%-91.1% specificity for different fibrosis stages in the validation cohort. q-FPs and histological scoring had nearly identical correlations with liver stiffness measurement, suggesting that the accuracy of q-FPs approached that of histological assessment. Among patients with paired liver biopsies, changes in the same q-FPs were associated with changes in fibrosis stage. At a median follow-up of 5.6 years, baseline q-FPs predicted liver-related events. CONCLUSION: q-FP is highly accurate in the assessment of fibrosis in NAFLD patients. This automated platform can be used in future studies as objective and reliable evaluation of histological fibrosis.


Assuntos
Cirrose Hepática/patologia , Hepatopatia Gordurosa não Alcoólica/patologia , Absorciometria de Fóton , Automação Laboratorial/métodos , Biópsia , Feminino , Humanos , Fígado/patologia , Fígado/ultraestrutura , Cirrose Hepática/diagnóstico , Estudos Longitudinais , Masculino , Hepatopatia Gordurosa não Alcoólica/diagnóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos