Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88.645
Filtrar
Mais filtros

Coleções SMS-SP
Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 119(47): e2214662119, 2022 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-36375085

RESUMO

Second harmonic generation microscopy (SHG) is generally acknowledged as a powerful tool for the label-free three-dimensional visualization of tissues and advanced materials, with one of its most popular applications being collagen imaging. Despite the great need, progress in super-resolved SHG imaging lags behind the developments reported over the past years in fluorescence-based optical nanoscopy. In this work, we demonstrate super-resolved re-scan SHG, qualitatively and quantitatively showing on collagenous tissues the available resolution advantage over the diffraction limit. We introduce as well super-resolved re-scan two-photon excited fluorescence microscopy, an imaging modality not explored to date.


Assuntos
Microscopia de Geração do Segundo Harmônico , Microscopia de Geração do Segundo Harmônico/métodos , Microscopia de Fluorescência/métodos , Colágeno , Fótons , Cintilografia
2.
Am J Gastroenterol ; 119(2): 331-341, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37782524

RESUMO

INTRODUCTION: Gastric emptying testing (GET) assesses gastric motility, however, is nonspecific and insensitive for neuromuscular disorders. Gastric Alimetry (GA) is a new medical device combining noninvasive gastric electrophysiological mapping and validated symptom profiling. This study assessed patient-specific phenotyping using GA compared with GET. METHODS: Patients with chronic gastroduodenal symptoms underwent simultaneous GET and GA, comprising a 30-minute baseline, 99m TC-labelled egg meal, and 4-hour postprandial recording. Results were referenced to normative ranges. Symptoms were profiled in the validated GA App and phenotyped using rule-based criteria based on their relationships to the meal and gastric activity: (i) sensorimotor, (ii) continuous, and (iii) other. RESULTS: Seventy-five patients were assessed, 77% female. Motility abnormality detection rates were as follows: GET 22.7% (14 delayed, 3 rapid), GA spectral analysis 33.3% (14 low rhythm stability/low amplitude, 5 high amplitude, and 6 abnormal frequency), and combined yield 42.7%. In patients with normal spectral analysis, GA symptom phenotypes included sensorimotor 17% (where symptoms strongly paired with gastric amplitude, median r = 0.61), continuous 30%, and other 53%. GA phenotypes showed superior correlations with Gastroparesis Cardinal Symptom Index, Patient Assessment of Upper Gastrointestinal Symptom Severity Index, and anxiety scales, whereas Rome IV Criteria did not correlate with psychometric scores ( P > 0.05). Delayed emptying was not predictive of specific GA phenotypes. DISCUSSION: GA improves patient phenotyping in chronic gastroduodenal disorders in the presence and absence of motility abnormalities with increased correlation with symptoms and psychometrics compared with gastric emptying status and Rome IV criteria. These findings have implications for the diagnostic profiling and personalized management of gastroduodenal disorders.


Assuntos
Duodenopatias , Gastroparesia , Humanos , Feminino , Masculino , Esvaziamento Gástrico/fisiologia , Gastroparesia/diagnóstico por imagem , Cintilografia
3.
Radiology ; 310(1): e230764, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38165245

RESUMO

While musculoskeletal imaging volumes are increasing, there is a relative shortage of subspecialized musculoskeletal radiologists to interpret the studies. Will artificial intelligence (AI) be the solution? For AI to be the solution, the wide implementation of AI-supported data acquisition methods in clinical practice requires establishing trusted and reliable results. This implementation will demand close collaboration between core AI researchers and clinical radiologists. Upon successful clinical implementation, a wide variety of AI-based tools can improve the musculoskeletal radiologist's workflow by triaging imaging examinations, helping with image interpretation, and decreasing the reporting time. Additional AI applications may also be helpful for business, education, and research purposes if successfully integrated into the daily practice of musculoskeletal radiology. The question is not whether AI will replace radiologists, but rather how musculoskeletal radiologists can take advantage of AI to enhance their expert capabilities.


Assuntos
Inteligência Artificial , Comércio , Humanos , Cintilografia , Exame Físico , Radiologistas
4.
Bioinformatics ; 39(1)2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36416135

RESUMO

SUMMARY: Limited by spatial resolution and visual contrast, bone scintigraphy interpretation is susceptible to subjective factors, which considerably affects the accuracy and repeatability of lesion detection and anatomical localization. In this work, we design and implement an end-to-end multi-task deep learning model to perform automatic lesion detection and anatomical localization in whole-body bone scintigraphy. A total of 617 whole-body bone scintigraphy cases including anterior and posterior views were retrospectively analyzed. The proposed semi-supervised model consists of two task flows. The first one, the lesion segmentation flow, received image patches and was trained in a supervised way. The other one, skeleton segmentation flow, was trained on as few as five labeled images in conjunction with the multi-atlas approach, in a semi-supervised way. The two flows joint in their encoder layers so each flow can capture more generalized distribution of the sample space and extract more abstract deep features. The experimental results show that the architecture achieved the highest precision in the finest bone segmentation task in both anterior and posterior images of whole-body scintigraphy. Such an end-to-end approach with very few manual annotation requirement would be suitable for algorithm deployment. Moreover, the proposed approach reliably balances unsupervised labels construction and supervised learning, providing useful insight for weakly labeled image analysis. SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.


Assuntos
Aprendizado Profundo , Estudos Retrospectivos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Cintilografia , Aprendizado de Máquina Supervisionado
5.
Magn Reson Med ; 91(6): 2294-2309, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38181183

RESUMO

PURPOSE: Quantitative MRI finds important applications in clinical and research studies. However, it is encoding intensive and may suffer from prohibitively long scan times. Accelerated MR parameter mapping techniques have been developed to help address these challenges. Here, an accelerated joint T1, T 2 * $$ {{\mathrm{T}}_2}^{\ast } $$ , frequency and proton density mapping technique with scan-specific self-supervised network reconstruction is proposed to synergistically combine parallel imaging, model-based, and deep learning approaches to speed up parameter mapping. METHODS: Proposed framework, Joint MAPLE, includes parallel imaging, signal modeling, and data consistency blocks which are optimized jointly in a combined loss function. A scan-specific self-supervised reconstruction is embedded into the framework, which takes advantage of multi-contrast data from a multi-echo, multi-flip angle, gradient echo acquisition. RESULTS: In comparison with parallel reconstruction techniques powered by low-rank methods, emerging scan specific networks, and model-based T 2 * $$ {{\mathrm{T}}_2}^{\ast } $$ estimation approaches, the proposed framework reduces the reconstruction error in parameter maps by approximately two-fold on average at acceleration rates as high as R = 16 with uniform sampling. It can outperform evaluated parallel reconstruction techniques up to four-fold on average in the presence of challenging sub-sampling masks. It is observed that Joint MAPLE performs well at extreme acceleration rates of R = 25 and R = 36 with error values less than 20%. CONCLUSION: Joint MAPLE enables higher fidelity parameter estimation at high acceleration rates by synergistically combining parallel imaging and model-based parameter mapping and exploiting multi-echo, multi-flip angle datasets. Utilizing a scan-specific self-supervised reconstruction obviates the need for large data sets for training while improving the parameter estimation ability.


Assuntos
Algoritmos , Encéfalo , Imageamento por Ressonância Magnética/métodos , Cintilografia , Prótons , Processamento de Imagem Assistida por Computador/métodos
6.
Opt Express ; 32(7): 11934-11951, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38571030

RESUMO

Optical coherence tomography (OCT) can resolve biological three-dimensional tissue structures, but it is inevitably plagued by speckle noise that degrades image quality and obscures biological structure. Recently unsupervised deep learning methods are becoming more popular in OCT despeckling but they still have to use unpaired noisy-clean images or paired noisy-noisy images. To address the above problem, we propose what we believe to be a novel unsupervised deep learning method for OCT despeckling, termed Double-free Net, which eliminates the need for ground truth data and repeated scanning by sub-sampling noisy images and synthesizing noisier images. In comparison to existing unsupervised methods, Double-free Net obtains superior denoising performance when trained on datasets comprising retinal and human tissue images without clean images. The efficacy of Double-free Net in denoising holds significant promise for diagnostic applications in retinal pathologies and enhances the accuracy of retinal layer segmentation. Results demonstrate that Double-free Net outperforms state-of-the-art methods and exhibits strong convenience and adaptability across different OCT images.


Assuntos
Algoritmos , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Retina/diagnóstico por imagem , Cintilografia , Processamento de Imagem Assistida por Computador/métodos
7.
Eur J Nucl Med Mol Imaging ; 51(3): 749-755, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37943339

RESUMO

BACKGROUND: In patients with marginal zone lymphoma (MZL), [18F]FDG PET/CT provided inconsistent diagnostic accuracy. C-X-C motif chemokine receptor 4 (CXCR4) is overexpressed in MZL and thus, may emerge as novel theranostic target. We aimed to evaluate the diagnostic performance of CXCR4-targeting [68Ga]Ga-PentixaFor when compared to [18F]FDG PET/CT in MZL. METHODS: Thirty-two untreated MZL patients (nodal, n = 17; extranodal, n = 13; splenic, n = 2) received [68Ga]Ga-PentixaFor and [18F]FDG PET/CT within median 2 days. We performed a visual and quantitative analysis of the total lymphoma volume by measuring maximum/peak standardized uptake values (SUVmax/peak), and calculating target-to-background ratios (TBR, defined as lesion-based SUVpeak divided by SUVmean from blood pool). Visual comparisons for both radiotracers were carried out for all target lesions (TL), and quantitative analysis of concordant TL evident on both scans. Last, MZL subtype analyses were also conducted. RESULTS: On a patient-based level, [68Ga]Ga-PentixaFor identified MZL manifestations in 32 (100%) subjects (vs. [18F]FDG, 25/32 [78.1%]). Of the 256 identified TL, 127/256 (49.6%) manifestations were evident only on CXCR4-directed imaging, while only 7/256 (2.7%) were identified on [18F]FDG but missed by [68Ga]Ga-PentixaFor. In the remaining 122/256 (47.7%) concordant TL, [68Ga]Ga-PentixaFor consistently provided increased metrics when compared to [18F]FDG: SUVmax, 10.3 (range, 2.53-37.2) vs. 5.72 (2.32-37.0); SUVpeak, 6.23 (1.58-25.7) vs. 3.87 (1.54-27.7); P < 0.01, respectively. Concordant TL TBR on [68Ga]Ga-PentixaFor (median, 3.85; range, 1.05-16.0) was also approximately 1.8-fold higher relative to [18F]FDG (median, 2.08; range, 0.81-28.8; P < 0.01). Those findings on image contrast, however, were driven by nodal MZL (P < 0.01), and just missed significance for extranodal MZL (P = 0.06). CONCLUSIONS: In newly diagnosed MZL patients, [68Ga]Ga-PentixaFor identified more sites of disease when compared to [18F]FDG, irrespective of MZL subtype. Quantitative PET parameters including TBR were also higher on [68Ga]Ga-PentixaFor PET/CT, suggesting improved diagnostic read-out using chemokine receptor-targeted imaging.


Assuntos
Complexos de Coordenação , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Fluordesoxiglucose F18 , Radioisótopos de Gálio , Peptídeos Cíclicos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons , Cintilografia
8.
Eur J Nucl Med Mol Imaging ; 51(5): 1268-1286, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38366197

RESUMO

The numbers of diagnostic and therapeutic nuclear medicine agents under investigation are rapidly increasing. Both novel emitters and novel carrier molecules require careful selection of measurement procedures. This document provides guidance relevant to dosimetry for first-in human and early phase clinical trials of such novel agents. The guideline includes a short introduction to different emitters and carrier molecules, followed by recommendations on the methods for activity measurement, pharmacokinetic analyses, as well as absorbed dose calculations and uncertainty analyses. The optimal use of preclinical information and studies involving diagnostic analogues is discussed. Good practice reporting is emphasised, and relevant dosimetry parameters and method descriptions to be included are listed. Three examples of first-in-human dosimetry studies, both for diagnostic tracers and radionuclide therapies, are given.


Assuntos
Medicina Nuclear , Compostos Radiofarmacêuticos , Humanos , Medicina Nuclear/métodos , Radiometria/métodos , Cintilografia , Compostos Radiofarmacêuticos/uso terapêutico , Guias de Prática Clínica como Assunto , Ensaios Clínicos como Assunto
9.
Eur J Nucl Med Mol Imaging ; 51(3): 820-827, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37843598

RESUMO

BACKGROUND: Clear evidence regarding the effect of reduced tumour accumulation in later peptide receptor radionuclide therapy (PRRT) cycles is lacking. Therefore, we aimed to quantify potential cycle effects for patients treated with [177Lu]Lu-HA-DOTATATE using a population pharmacokinetic (PK) modelling approach. METHODS: A population PK model was developed using imaging data from 48 patients who received multiple cycles of [177Lu]Lu-HA-DOTATATE. The five-compartment model included a central, kidney, spleen, tumour and lumped rest compartment. Tumour volume and continued use of long-acting somatostatin analogues (SSAs) were tested as covariates in the model. In addition, the presence of a cycle effect was evaluated by relating the uptake rate in a specific cycle as a fraction of the (tumour or organ) uptake rate in the first cycle. RESULTS: The final PK model adequately captured observed radioactivity accumulation in kidney, spleen and tumour. A higher tumour volume was identified to increase the tumour uptake rate, where a twofold increase in tumour volume resulted in a 2.3-fold higher uptake rate. Also, continued use of long-acting SSAs significantly reduced the spleen uptake rate (68.4% uptake compared to SSA withdrawal (10.5% RSE)). Lastly, a cycle effect was significantly identified, where tumour uptake rate decreased to 86.9% (5.3% RSE) in the second cycle and even further to 79.7% (5.6% RSE) and 77.6% (6.2% RSE) in the third and fourth cycle, respectively, compared to cycle one. CONCLUSIONS: Using a population PK modelling approach, the cycle effect of reduced tumour uptake in subsequent PRRT cycles was quantified. Our findings implied that downregulation of target receptors is probably not the major cause of the cycle effect, due to a plateau in the decrease of tumour uptake in the fourth cycle.


Assuntos
Tumores Neuroendócrinos , Compostos Organometálicos , Tomografia por Emissão de Pósitrons , Cintilografia , Humanos , Octreotida , Tumores Neuroendócrinos/radioterapia , Tumores Neuroendócrinos/patologia , Somatostatina , Radioisótopos , Receptores de Peptídeos , Compostos Organometálicos/uso terapêutico
10.
Eur J Nucl Med Mol Imaging ; 51(3): 768-778, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37823909

RESUMO

PURPOSE: Molecular radiotherapy is a treatment modality that is highly suitable for targeting micrometastases and [177Lu]Lu-DOTATATE is currently being explored as a potential novel treatment option for high-risk neuroblastoma. p53 is a key player in the proapoptotic signalling in response to radiation-induced DNA damage and is therefore a potential target for radiosensitisation. METHODS: This study investigated the use of the p53 stabilising peptide VIP116 and [177Lu]Lu-DOTATATE, either alone or in combination, for treatment of neuroblastoma tumour xenografts in mice. Initially, the uptake of [177Lu]Lu-DOTATATE in the tumours was confirmed, and the efficacy of VIP116 as a monotherapy was evaluated. Subsequently, mice with neuroblastoma tumour xenografts were treated with placebo, VIP116, [177Lu]Lu-DOTATATE or a combination of both agents. RESULTS: The results demonstrated that monotherapy with either VIP116 or [177Lu]Lu-DOTATATE significantly prolonged median survival compared to the placebo group (90 and 96.5 days vs. 50.5 days, respectively). Notably, the combination treatment further improved median survival to over 120 days. Furthermore, the combination group exhibited the highest percentage of complete remission, corresponding to a twofold increase compared to the placebo group. Importantly, none of the treatments induced significant nephrotoxicity. Additionally, the therapies affected various molecular targets involved in critical processes such as apoptosis, hypoxia and angiogenesis. CONCLUSION: In conclusion, the combination of VIP116 and [177Lu]Lu-DOTATATE presents a promising novel treatment approach for neuroblastoma. These findings hold potential to advance research efforts towards a potential cure for this vulnerable patient population.


Assuntos
Neuroblastoma , Tumores Neuroendócrinos , Compostos Organometálicos , Tomografia por Emissão de Pósitrons , Cintilografia , Humanos , Camundongos , Animais , Proteína Supressora de Tumor p53 , Octreotida/uso terapêutico , Compostos Organometálicos/uso terapêutico , Xenoenxertos , Neuroblastoma/radioterapia , Tumores Neuroendócrinos/radioterapia
11.
Eur J Nucl Med Mol Imaging ; 51(3): 681-690, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37843599

RESUMO

PURPOSE: There is a need for early quantitative markers of potential treatment response in patients with hereditary transthyretin (ATTRv) amyloidosis to guide therapy. This study aims to evaluate changes in cardiac tracer uptake on bone scintigraphy in ATTRv amyloidosis patients on different treatments. METHODS: In this retrospective cohort study, outcomes of 20 patients treated with the transthyretin (TTR) gene silencer patisiran were compared to 12 patients treated with a TTR-stabilizer. Changes in NYHA class, cardiac biomarkers in serum, wall thickness, and diastolic parameters on echocardiography and NYHA class during treatment were evaluated. RESULTS: Median heart/whole-body (H/WB) ratio on bone scintigraphy decreased from 4.84 [4.00 to 5.31] to 4.16 [3.66 to 4.81] (p < .001) in patients treated with patisiran for 29 [15-34] months. No changes in the other follow-up parameters were observed. In patients treated with a TTR-stabilizer for 24 [20 to 30] months, H/WB ratio increased from 4.46 [3.24 to 5.13] to 4.96 [ 3.39 to 5.80] (p = .010), and troponin T increased from 19.5 [9.3 to 34.0] ng/L to 20.0 [11.8 to 47.8] ng/L (p = .025). All other parameters did not change during treatment with a TTR-stabilizer. CONCLUSION: A change in cardiac tracer uptake on bone scintigraphy may be an early marker of treatment-specific response or disease progression in ATTRv amyloidosis patients.


Assuntos
Neuropatias Amiloides Familiares , Cardiomiopatias , Humanos , Pré-Albumina/genética , Estudos Retrospectivos , Seguimentos , Neuropatias Amiloides Familiares/diagnóstico por imagem , Cintilografia , Cardiomiopatias/diagnóstico por imagem
12.
Eur J Nucl Med Mol Imaging ; 51(3): 828-840, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37947850

RESUMO

PURPOSE: We aimed to investigate the potential of [68Ga]Ga-FAPI-04 PET/CT as an alternative diagnostic and theranostic tool in well-differentiated NETs refractory to [177Lu]Lu-DOTATATE therapy. METHODS: Patients who received at least two cycles of [177Lu]Lu-DOTATATE therapy for metastatic NETs and progressed under treatment were included. All patients had performed [68Ga]Ga-DOTATATE and [68Ga]Ga-FAPI-04 PET/CT within 3 weeks. The number of PET-positive lesions related to NETs and tumor sites was documented. Mann-Whitney U and chi-square tests were used to compare SUVmax levels of tracers and the number of detected metastases. RESULTS: Twelve patients (7 male, 5 female) who met the eligibility criteria were included in the study. Ten patients had grade 1-2 NET of various origins, and two had paraganglioma and pheochromocytoma. One hundred ninety-eight of 230 lesions (86%) were SSTR positive with a median SUVmax of 16.6 (2.2-76.5), and 88 of 230 lesions (38.2%) were [68Ga]Ga-FAPI-04 positive with a median SUVmax of 5.1 (2.3-21). Median SUVmax level and detected number of tumors were significantly higher in [68Ga]Ga-DOTATATE PET/CT (p=<0.001). [68Ga]Ga-FAPI-04 PET/CT was completely (n:2) or almost completely (n:3) negative in 5 (42%) patients. Two (17%) patients had flip-flop SSTR/FAPI uptake in tumors. In four patients (33%), tumor uptake or the number of PET-positive lesions was inferior in [68Ga]Ga-FAPI-04 PET/CT. In only one patient (8%), tumor uptakes were higher in [68Ga]Ga-FAPI-04 PET/CT. Low-dose [177Lu]Lu-FAPI-46 dosimetry was performed on the FAPI-dominant patient; absorbed radiation doses per GBq were 1.26 Gy, 0.36 Gy, 0.32 Gy, and 0.2 Gy for kidneys, liver, spleen, and total body, respectively. The mean absorbed dose per GBq was 0.33 Gy for liver mass and 0.41 Gy for metastatic lymph nodes. CONCLUSION: Our preliminary results demonstrated that [68Ga]Ga-FAPI-04 PET/CT mainly failed in well-differentiated NETs refractory to [177Lu]Lu-DOTATATE therapy and had a limited role as an alternative diagnostic or theranostic agent. Further investigations with a larger patient population are required to determine the impact of [68Ga]Ga-FAPI-04 PET/CT on NETs.


Assuntos
Tumores Neuroendócrinos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Quinolinas , Cintilografia , Humanos , Masculino , Feminino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/terapia , Tumores Neuroendócrinos/patologia , Radioisótopos de Gálio , Medicina de Precisão , Biomarcadores
13.
Rev Endocr Metab Disord ; 25(1): 1-3, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38041785

RESUMO

The prevalence of thyroid disease continues to rise. As a consequence, the research in the thyroid field has significantly increased over time. Thus, clinicians, and endocrinologists first, have to be aware of the important continuous progress achieved, in particular of thyroid cancer, to better manage their patients. This themed issue, titled "New Insights in Thyroid Diagnosis and Treatment," delves deep into contemporary hot topics in thyroid field. These papers included in the present issue are focused on several aspects in this area, such as imaging, molecular analysis, machine learning and radiomics, nuclear medicine, clinical, and laboratory. Seven papers centers around thyroid cancer. Three papers review imaging modalities for thyroid nodule/cancer assessment. Two papers report a comprehensive review of metabolic issues involving thyroid gland. Finally, a large overview about genetics of Graves' disease is reported in another study. Clinicians will find this issue very interesting.


Assuntos
Doença de Graves , Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Humanos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Doença de Graves/diagnóstico , Nódulo da Glândula Tireoide/diagnóstico por imagem , Cintilografia
14.
Mol Psychiatry ; 28(8): 3384-3390, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37532797

RESUMO

In humans, the negative effects of alcohol are linked to immune dysfunction in both the periphery and the brain. Yet acute effects of alcohol on the neuroimmune system and its relationships with peripheral immune function are not fully understood. To address this gap, immune response to an alcohol challenge was measured with positron emission tomography (PET) using the radiotracer [11C]PBR28, which targets the 18-kDa translocator protein, a marker sensitive to immune challenges. Participants (n = 12; 5 F; 25-45 years) who reported consuming binge levels of alcohol (>3 drinks for females; >4 drinks for males) 1-3 months before scan day were enrolled. Imaging featured a baseline [11C]PBR28 scan followed by an oral laboratory alcohol challenge over 90 min. An hour later, a second [11C]PBR28 scan was acquired. Dynamic PET data were acquired for at least 90 min with arterial blood sampling to measure the metabolite-corrected input function. [11C]PBR28 volume of distributions (VT) was estimated in the brain using multilinear analysis 1. Subjective effects, blood alcohol levels (BAL), and plasma cytokines were measured during the paradigm. Full completion of the alcohol challenge and data acquisition occurred for n = 8 (2 F) participants. Mean peak BAL was 101 ± 15 mg/dL. Alcohol significantly increased brain [11C]PBR28 VT (n = 8; F(1,49) = 34.72, p > 0.0001; Cohen's d'=0.8-1.7) throughout brain by 9-16%. Alcohol significantly altered plasma cytokines TNF-α (F(2,22) = 17.49, p < 0.0001), IL-6 (F(2,22) = 18.00, p > 0.0001), and MCP-1 (F(2,22) = 7.02, p = 0.004). Exploratory analyses identified a negative association between the subjective degree of alcohol intoxication and changes in [11C]PBR28 VT. These findings provide, to our knowledge, the first in vivo human evidence for an acute brain immune response to alcohol.


Assuntos
Encéfalo , Tomografia por Emissão de Pósitrons , Masculino , Feminino , Humanos , Tomografia por Emissão de Pósitrons/métodos , Encéfalo/metabolismo , Cintilografia , Concentração Alcoólica no Sangue , Receptores de GABA/metabolismo , Imunidade , Citocinas/metabolismo
15.
Endoscopy ; 56(5): 345-352, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38141620

RESUMO

INTRODUCTION: Gastric peroral endoscopic myotomy (G-POEM) is a promising technique for treating refractory gastroparesis. We present the first double-blind randomized study comparing the clinical efficacy of G-POEM versus pyloric botulinum toxin injection (BTI). METHODS: This randomized study, conducted in two expert centers, enrolled patients with refractory gastroparesis, medically managed for >6 months and confirmed by gastric emptying scintigraphy (GES), into two groups, G-POEM versus BTI, with follow-up of 1 year. The primary end point was the 3-month clinical efficacy, defined as a >1-point decrease in the mean Gastroparesis Cardinal Symptom Index (GCSI) score. Secondary end points were: 1-year efficacy, GES evolution, adverse events, and quality of life. RESULTS: 40 patients (22 women; mean age 48.1 [SD 17.4]), with mean symptom duration of 5.8 (SD 5.7) years, were randomized. Etiologies included idiopathic (n=18), diabetes (n=11), postoperative (n=6), and mixed (n=4). G-POEM showed a higher 3-month clinical success than BTI (65% vs. 40%, respectively; P=0.10), along with non-significantly higher 1-year clinical success (60% vs. 40%, respectively) on intention-to-treat analysis. The GCSI decreased in both groups at 3 months and 1 year. Only three minor adverse events occurred in the G-POEM group. The GES improvement rate was 72% in the G-POEM group versus 50% in the BTI group (non-significant). CONCLUSION: G-POEM seems to have a higher clinically relevant success rate than BTI, but this was not statistically demonstrated. This study confirms the interest in treatments targeting the pylorus, either mechanically or chemically, for managing refractory gastroparesis.


Assuntos
Toxinas Botulínicas , Gastroparesia , Piloromiotomia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Toxinas Botulínicas/administração & dosagem , Toxinas Botulínicas/efeitos adversos , Esvaziamento Gástrico/efeitos dos fármacos , Gastroparesia/tratamento farmacológico , Gastroparesia/etiologia , Gastroparesia/cirurgia , Gastroscopia , Injeções , Piloromiotomia/métodos , Piloromiotomia/efeitos adversos , Piloro/cirurgia , Qualidade de Vida , Cintilografia , Resultado do Tratamento
16.
World J Urol ; 42(1): 382, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38904679

RESUMO

BACKGROUND: Current potential living kidney donor's assessment includes functional and anatomical evaluation. Scintigraphy is recommended in some cases and some centers include this test in the donor's protocol. Recent studies advocate for the avoidance of this test as CT or MRI volumetry showed to accurately assess donor's renal function. OBJECTIVE: To summarize scientific evidence on image tests for pre-donation and/or post-nephrectomy renal function evaluation. EVIDENCE ACQUISITION: This review followed the guidelines set by the European Association of Urology and adhered to PRISMA 2020 recommendations. The protocol was registered in PROSPERO on 10th December 2022 (ID: CRD42022379273). EVIDENCE SYNTHESIS: Twenty-one studies met the inclusion criteria after thorough screening and eligibility assessment. According to QUADAS-2, patient selection and flow/timing domains showed a predominant low risk of bias. The correlation between split renal function (SRF) using CT and scintigraphy varied from weak (r = 0.21) to remarkably strong (r = 0.949). Bland-Altman agreement demonstrated moderate to excellent results, with mean differences ranging from -0.06% to 1.76%. The correlation between split renal volume (CT) and estimated glomerular filtration rate (eGFR) at 6 months or 1 year after nephrectomy showed a moderate correlation, with coefficients ranging from 0.708 to 0.83. The correlation between SRF (MRI) and renal scintigraphy reported a moderate correlation, with correlation coefficients of 0.58 and 0.84. MRI and scintigraphy displayed a good agreement, with a 66% agreement observed and mean differences of ± 0.3%. CONCLUSIONS: Despite study heterogeneity, MRI or CT-based renal volumetry appears promising compared to scintigraphy, with favorable correlations and agreement.


Assuntos
Transplante de Rim , Rim , Doadores Vivos , Imageamento por Ressonância Magnética , Nefrectomia , Cintilografia , Tomografia Computadorizada por Raios X , Humanos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Nefrectomia/métodos , Rim/diagnóstico por imagem , Rim/anatomia & histologia , Testes de Função Renal , Coleta de Tecidos e Órgãos/métodos
17.
Eur Radiol ; 34(4): 2212-2222, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37673964

RESUMO

OBJECTIVES: To compare the efficacy of computed tomography volumetry (CTV), technetium99m galactosyl-serum-albumin (99mTc-GSA) scintigraphy, and gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic-acid-enhanced MRI (EOB-MRI) in estimating the liver fibrosis (LF) stage in patients undergoing liver resection. METHODS: This retrospective study included 91 consecutive patients who had undergone preoperative dynamic CT and 99mTc-GSA scintigraphy. EOB-MRI was performed in 76 patients. CTV was used to measure the total liver volume (TLV), spleen volume (SV), normalised to the body surface area (BSA), and liver-to-spleen volume ratio (TLV/SV). 99mTc-GSA scintigraphy provided LHL15, HH15, and GSA indices. The liver-to-spleen ratio (LSR) was calculated in the hepatobiliary phase of EOB-MRI. Hyaluronic acid and type 4 collagen levels were measured in 65 patients. Logistic regression and receiver operating characteristic (ROC) analyses were performed to identify useful parameters for estimating the LF stage and laboratory data. RESULTS: According to the multivariable logistic regression analysis, SV/BSA (odds ratio [OR], 1.01; 95% confidence interval [CI], 1.003-1.02; p = 0.011), LSR (OR, 0.06; 95%CI, 0.004-0.70; p = 0.026), and hyaluronic acid (OR, 1.01; 95%CI, 1.001-1.02; p = 0.024) were independent variables for severe LF (F3-4). Combined SV/BSA, LSR, and hyaluronic acid correctly estimated severe LF, with an AUC of 0.91, which was significantly larger than the AUCs of the GSA index (AUC = 0.84), SV/BSA (AUC = 0.83), or LSR (AUC = 0.75) alone. CONCLUSIONS: Combined CTV, EOB-MRI, and hyaluronic acid analyses improved the estimation accuracy of severe LF compared to CTV, EOB-MRI, or 99mTc-GSA scintigraphy individually. CLINICAL RELEVANCE STATEMENT: The combined analysis of spleen volume on CT volumetry, liver-to-spleen ratio on gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic-acid-enhanced MRI, and hyaluronic acid can identify severe liver fibrosis associated with a high risk of liver failure after hepatectomy and recurrence in patients with hepatocellular carcinoma. KEY POINTS: • Spleen volume of CT volumetry normalised to the body surface area, liver-to-spleen ratio of EOB-MRI, and hyaluronic acid were independent variables for liver fibrosis. • CT volumetry and EOB-MRI enable the detection of severe liver fibrosis, which may correlate with post-hepatectomy liver failure and complications. • Combined CT volumetry, gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic-acid-enhanced MRI (EOB-MRI), and hyaluronic acid analyses improved the estimation of severe liver fibrosis compared to technetium99m galactosyl-serum-albumin scintigraphy.


Assuntos
Falência Hepática , Neoplasias Hepáticas , Poliaminas , Humanos , Tecnécio , Albumina Sérica , Estudos Retrospectivos , Gadolínio , Ácido Hialurônico , Compostos Radiofarmacêuticos , Neoplasias Hepáticas/diagnóstico por imagem , Testes de Função Hepática , Fígado/diagnóstico por imagem , Fígado/cirurgia , Fígado/patologia , Cintilografia , Agregado de Albumina Marcado com Tecnécio Tc 99m , Pentetato de Tecnécio Tc 99m , Cirrose Hepática/patologia , Hepatectomia , Tomografia Computadorizada por Raios X , Imageamento por Ressonância Magnética/métodos
18.
J Surg Res ; 293: 613-617, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37837816

RESUMO

INTRODUCTION: Lymphoscintigraphy (LS) helps identify drainage to interval (epitrochlear or popliteal) lymph node basins for extremity melanomas. This study evaluated how often routine LS evaluation identified an interval sentinel lymph node (SLN) and how often that node was found to have metastasis. METHODS: A single institution, retrospective study identified patients with an extremity melanoma who underwent routine LS and SLN biopsy over a 25-y period. Comparisons of factors associated with the identification of interval node drainage and tumor status were made. RESULTS: In 634 patients reviewed, 5.7% of patients drained to an interval SLN. Of those biopsied, 29.2% were positive for micrometastases. Among patients with biopsies of both the traditional and interval nodal basins, nearly 20% had positive interval nodes with negative SLNs in the traditional basin. Sex, age, thickness, ulceration, and the presence of mitotic figures were not predictive of identifying an interval node on LS, nor for having disease in an interval node. Anatomic location of the primary melanoma was the only identifiable risk factor, as no interval nodes were identified in melanomas of the thigh or upper arm (P ≤ 0.001). CONCLUSIONS: Distal extremity melanomas have a moderate risk of mapping to an interval SLN. Routine LS should be considered in these patients, especially as these may be the only tumor-positive nodes. However, primary extremity melanomas proximal to the epitrochlear or popliteal nodal basins do not map to interval nodes, and improved savings and workflow could be realized by selectively omitting routine LS in such patients.


Assuntos
Linfadenopatia , Melanoma , Linfonodo Sentinela , Neoplasias Cutâneas , Humanos , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/patologia , Linfocintigrafia , Estudos Retrospectivos , Metástase Linfática/diagnóstico por imagem , Metástase Linfática/patologia , Cintilografia , Neoplasias Cutâneas/diagnóstico por imagem , Neoplasias Cutâneas/cirurgia , Neoplasias Cutâneas/patologia , Melanoma/diagnóstico por imagem , Melanoma/cirurgia , Melanoma/patologia , Linfonodos/patologia , Biópsia de Linfonodo Sentinela , Extremidade Superior/diagnóstico por imagem , Excisão de Linfonodo , Melanoma Maligno Cutâneo
19.
Q J Nucl Med Mol Imaging ; 68(1): 23-31, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38587360

RESUMO

Pediatric gastrointestinal imaging plays a crucial role in evaluating and managing digestive system disorders in children. This comprehensive review dives into the nuances of pediatric gastrointestinal imaging techniques, focusing on three specific modalities: gastric emptying scintigraphy (GES), intestinal transit scintigraphy (ITS), and gastrointestinal bleeding scintigraphy. GES involves real-time monitoring of stomach emptying using radiotracers and gamma camera technology. While challenges exist in standardizing protocols due to age-specific meal compositions, GES remains pivotal in diagnosing motility disorders, gastroesophageal reflux, and abdominal pain in children. ITS, utilizing [67Ga], provides insights into gastrointestinal motility disorders such as Hirschsprung disease. It aids in whole-gut transit evaluation, guiding surgical interventions and improving long-term clinical outcomes. Gastrointestinal bleeding scintigraphy, employing [99mTc], assists in diagnosing conditions like Meckel's diverticulum and occult bleeding, offering continuous monitoring to pinpoint the bleeding site along the entire gastrointestinal tract. SPECT-CT improves the accuracy and the standards of care. Each technique's protocol details, clinical indications, and diagnostic capabilities are thoroughly discussed, highlighting the importance of these non-invasive, functional imaging modalities in pediatric gastroenterology.


Assuntos
Esvaziamento Gástrico , Radioisótopos , Humanos , Criança , Cintilografia , Hemorragia Gastrointestinal
20.
Q J Nucl Med Mol Imaging ; 68(1): 3-22, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38445832

RESUMO

Congenital anomalies of the kidney and urinary tract, as well as urinary infections, are very frequent in children. After the clinical and laboratory evaluation, the first imaging procedure to be done is a renal and bladder ultrasound, but afterwards, a main contribution comes from nuclear medicine. Through minimally invasive and sedation-free procedures, nuclear medicine allows the evaluation of the functional anatomy of the urinary tract, and the quantification of renal function and drainage. If pediatric dosage cards provided by scientific societies are used, radiation exposure can also be low. In the pediatric conditions previously mentioned, nuclear medicine is used both for initial diagnosis and follow-up, mostly in cases of suspicion of ureteropelvic or ureterovesical junction syndromes, as well as vesicoureteral reflux or renal scars of febrile infectious episodes. Pediatric nephro-urology constitutes a significant workload of pediatric nuclear medicine departments. The following paragraphs are a revision of the renal radiopharmaceuticals, as well as the nuclear nephro-urology procedures - dynamic and static renal scintigraphy, and direct and indirect radionuclide cystography. A summary of the techniques, main indications, interpretation criteria and pitfalls will be provided. Some future directions for the field are also pointed out, among which the most relevant is the need for nuclear medicine professionals to use standardized protocols and integrate multidisciplinary teams with other pediatric and adult health professionals that manage these life-long pediatric pathologies, which are recognized as an important cause of adult chronic kidney disease.


Assuntos
Medicina Nuclear , Urologia , Criança , Humanos , Medicina Nuclear/métodos , Urologia/métodos , Cintilografia , Rim/diagnóstico por imagem , Diagnóstico por Imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA