Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 456
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
BMC Pregnancy Childbirth ; 22(1): 177, 2022 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-35241026

RESUMO

BACKGROUND: The aim of the present study was to clarify fetal heart rate (FHR) evolution patterns in infants with cerebral palsy (CP) according to different types of umbilical cord complications. METHODS: This case-control study included children born: with a birth weight ≥2000 g, at gestational age ≥33 weeks, with disability due to CP, and between 2009 and 2014. Obstetric characteristics and FHR patterns were compared among patients with CP associated with (126 cases) and without (594 controls) umbilical cord complications. RESULTS: There were 32 umbilical cord prolapse cases and 94 cases with coexistent antenatal umbilical cord complications. Compared with the control group, the persistent non-reassuring pattern was more frequent in cases with coexistent antenatal umbilical cord complications (p = 0.012). A reassuring FHR pattern was observed on admission, but resulted in prolonged deceleration, especially during the first stage of labor, and was significantly identified in 69% of cases with umbilical cord prolapse and 35% of cases with antenatal cord complications, compared to 17% of control cases (p < 0.001). CONCLUSION: Hypercoiled cord and abnormal placental umbilical cord insertion, may be associated with CP due to acute hypoxic-ischemic injury as well as sub-acute or chronic adverse events during pregnancy, while umbilical cord prolapse may be characterized by acute hypoxic-ischemic injury during delivery.


Assuntos
Paralisia Cerebral/etiologia , Frequência Cardíaca Fetal , Doenças do Recém-Nascido/etiologia , Complicações do Trabalho de Parto/fisiopatologia , Complicações na Gravidez/fisiopatologia , Cordão Umbilical/fisiopatologia , Adulto , Traumatismos do Nascimento/complicações , Estudos de Casos e Controles , Feminino , Humanos , Hipóxia-Isquemia Encefálica/complicações , Recém-Nascido , Masculino , Gravidez , Prolapso , Cordão Umbilical/anormalidades , Cordão Umbilical/irrigação sanguínea
2.
Pediatr Dev Pathol ; 24(3): 241-245, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33593145

RESUMO

Heterotopic liver tissue in the umbilical cord is rare, and the outcome is quite unpredictable based on the few reported cases. We present a case of heterotopic liver nodule in the umbilical cord of a midtrimester fetus who died in utero. Although such association has only been reported once, heterotopic nodular tissue in the umbilical cord must be regarded as a potential cause of fetal demise by a mechanism analogous to the more common umbilical cord abnormalities resulting in umbilical vessel compromise.


Assuntos
Coristoma/patologia , Morte Fetal/etiologia , Fígado/patologia , Cordão Umbilical/anormalidades , Cordão Umbilical/patologia , Feminino , Humanos , Gravidez , Artéria Umbilical Única/patologia
3.
BMC Pregnancy Childbirth ; 21(1): 211, 2021 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-33731044

RESUMO

BACKGROUND: Umbilical cord may insert abnormally i.e. marginal insertion to a placenta which can cause different birth and perinatal complications. Despite the increased effort taken by different responsible bodies, the prevalence of birth and perinatal complications are still high, possibly due to anomalous cord insertion. So far, anomalous cord insertion lacks proper attention in different medical settings. Hence, the present study aims to assess the magnitude, risk factors, and adverse birth outcomes of marginal cord insertion among singleton births. METHODS: An institution-based cross-sectional study design was conducted. A systematic random sampling technique was used to select study participants. Data were collected by using a structured questionnaire and it was entered into epi-data version 3.1 then exported to SPSS version 20 for data cleansing and analysis. Bi-variable and multivariable logistic regressions were employed to identify risk factors and adverse outcomes associated with marginal cord insertions. Crude and adjusted odds ratio (P-value < 0.05) with a 95% confidence interval were calculated. RESULT: The magnitude of marginal cord insertion was 6.4% (95% CI = 4.4-8.8%) in singleton pregnancies. Independent risk factors for marginal cord insertion were advanced maternal age (AOR = 2.24, 95% CI: 1.35-11.08), primiparity (AOR = 1.98, 95% CI: 1.37-8.69), maternal chronic hypertension (AOR = 3.07, 95% CI: 1.66-9.76), previous cesarean delivery (AOR = 2.51, 95% CI: 1.43-10.21), and use of intrauterine contraceptive device before pregnancy (AOR = 2.22, 95% CI: 1.36-12.30). Pregnancies complicated by marginal cord insertion are at higher risk to develop low birth weight (AOR = 2.89, 95% CI: 1.23-6.80), preterm birth (AOR = 4.00, 95% CI: 1.44-11.14), and emergency cesarean delivery (AOR = 3.68, 95% CI: 1.03-13.81). CONCLUSION AND RECOMMENDATION: Marginal cord insertion is a mistreated potential risk for low birth weight, preterm birth, and emergency cesarean delivery. Routine screening of marginal cord insertion should be considered in pregnancies with advanced age, nulliparity, hypertensive disorder, history of cesarean section, and intrauterine contraceptive device usage before pregnancy.


Assuntos
Cesárea/estatística & dados numéricos , Complicações na Gravidez , Nascimento Prematuro/epidemiologia , Cordão Umbilical/anormalidades , Adulto , Estudos Transversais , Etiópia/epidemiologia , Feminino , Humanos , Recém-Nascido de Baixo Peso , Recém-Nascido , Dispositivos Intrauterinos/estatística & dados numéricos , Idade Materna , Gravidez , Complicações na Gravidez/diagnóstico , Complicações na Gravidez/epidemiologia , Complicações na Gravidez/cirurgia , Resultado da Gravidez/epidemiologia , Prevalência , Fatores de Risco
4.
Arch Gynecol Obstet ; 304(1): 59-64, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33389094

RESUMO

BACKGROUND: Thrombosis of umbilical vessels is a rare occurrence that is difficult to detect during routine antenatal examinations but can lead to poor perinatal outcomes. OBJECTIVE: The aim of this study is to examine the association between meaningful clinical manifestations and features associated with thrombosis of umbilical vessels, and to evaluate optimal management options. METHODS: A retrospective study of umbilical cord thrombi cases enrolled between 2015-2019 was carried out. Data were analyzed from the medical archives where the diagnosis of all cases was established by histopathology. RESULTS: Gross examination reported additional cord abnormalities (7/10), including the irregular length of the umbilical cord, narrowed cord with hyper-coiling, swollen cord with deficiency of Wharton's jelly, placenta velamentous and umbilical infarction. Pathological examination accounted for 10 cases of umbilical cord thrombosis including umbilical artery embolism (3/10), umbilical vein thrombi (5/10) and funisitis (2/10). Clinical findings depicted that the chief complaint was decreased fetal movement companied by nonreactive NST tests (5/10). With the exception of two stillbirths, the remaining pregnancies (8/10) were terminated by cesarean section. All neonates are alive, including one VLBW and three LBW cases. CONCLUSION: We have observed that umbilical structural dysplasia, maternal coagulation disorder, vascular endothelial injury and elevated blood glucose may lead to the formation of thrombosis. Focus on specific signs during a prenatal ultrasound, EFM monitoring and counting fetal movements can help in early identification of umbilical cord thrombi. Our results support the more effective approach of emergency cesarean section during the third trimester.


Assuntos
Cesárea/efeitos adversos , Trombose/patologia , Artérias Umbilicais/patologia , Cordão Umbilical/anormalidades , Feminino , Morte Fetal/etiologia , Monitorização Fetal/métodos , Humanos , Recém-Nascido , Gravidez , Complicações Cardiovasculares na Gravidez/diagnóstico , Resultado da Gravidez , Terceiro Trimestre da Gravidez , Estudos Retrospectivos , Fatores de Risco , Natimorto , Trombose/diagnóstico , Trombose/etiologia , Ultrassonografia Pré-Natal/métodos , Artérias Umbilicais/diagnóstico por imagem , Cordão Umbilical/diagnóstico por imagem
5.
Am J Obstet Gynecol ; 223(6): 907.e1-907.e13, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32497609

RESUMO

BACKGROUND: It is crucial to interpret fetal heart rate patterns with a focus on the pattern evolution during labor to estimate the relationship between cerebral palsy and delivery. However, nationwide data are not available. OBJECTIVE: The aim of our study was to demonstrate the features of fetal heart rate pattern evolution and estimate the timing of fetal brain injury during labor in cerebral palsy cases. STUDY DESIGN: In this longitudinal study, 1069 consecutive intrapartum fetal heart rate strips from infants with severe cerebral palsy at or beyond 34 weeks of gestation, were analyzed. They were categorized as follows: (1) continuous bradycardia (Bradycardia), (2) persistently nonreassuring, (3) reassuring-prolonged deceleration, (4) Hon's pattern, and (5) persistently reassuring. The clinical factors underlying cerebral palsy in each group were assessed. RESULTS: Hypoxic brain injury during labor (those in the reassuring-prolonged deceleration and Hon's pattern groups) accounted for 31.5% of severe cerebral palsy cases and at least 30% of those developed during the antenatal period. Of the 1069 cases, 7.86% were classified as continuous bradycardia (n=84), 21.7% as persistently nonreassuring (n=232), 15.6% as reassuring-prolonged deceleration (n=167), 15.9% as Hon's pattern (n=170), 19.8% as persistently reassuring (n=212), and 19.1% were unclassified (n=204). The overall interobserver agreement was moderate (kappa 0.59). Placental abruption was the most common cause (31.9%) of cerebral palsy, accounting for almost 90% of cases in the continuous bradycardia group (64 of 73). Among the cases in the Hon's pattern group (n=67), umbilical cord abnormalities were the most common clinical factor for cerebral palsy development (29.9%), followed by placental abruption (20.9%), and inappropriate operative vaginal delivery (13.4%). CONCLUSION: Intrapartum hypoxic brain injury accounted for approximately 30% of severe cerebral palsy cases, whereas a substantial proportion of the cases were suspected to have either a prenatal or postnatal onset. Up to 16% of cerebral palsy cases may be preventable by placing a greater focus on the earlier changes seen in the Hon's fetal heart rate progression.


Assuntos
Bradicardia/fisiopatologia , Paralisia Cerebral , Sofrimento Fetal/fisiopatologia , Hipóxia Fetal/fisiopatologia , Frequência Cardíaca Fetal , Hipóxia Encefálica/fisiopatologia , Cordão Nucal/fisiopatologia , Complicações do Trabalho de Parto/fisiopatologia , Adulto , Cardiotocografia , Estudos de Coortes , Feminino , Sangue Fetal , Humanos , Recém-Nascido , Masculino , Cordão Nucal/epidemiologia , Gravidez , Cordão Umbilical/anormalidades
6.
J Med Primatol ; 49(2): 113-115, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31879963

RESUMO

Obstruction of umbilical blood flow is a common cause of death in fetal nonhuman primates, but cord accidents have not been reported in the macaque. We describe two cases of cord accident in rhesus macaques (Macaca mulatta) resulting in fetal death at approximately 110 and 50 days of gestation, respectively.


Assuntos
Morte Fetal , Doenças Fetais/patologia , Macaca mulatta , Doenças dos Macacos/patologia , Anormalidade Torcional/veterinária , Cordão Umbilical/anormalidades , Animais , Morte Fetal/etiologia , Doenças Fetais/etiologia , Doenças dos Macacos/etiologia , Anormalidade Torcional/patologia
7.
Pediatr Dev Pathol ; 23(2): 107-114, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31345137

RESUMO

This study focused to investigate a possible association of extensive umbilical hypercoiling (displaying an umbilical coiling index [UCI] of at least 1.0 coils/cm), clinical outcome, and associated pathoanatomical placental lesions. Of the 771 singleton placentas from the second and third trimesters submitted for pathoanatomical evaluation, 15 cases (2%) displayed extensive hypercoiling. There was an association of excessive hypercoiling with hypotrophy of fetuses and children (11 cases) and fetal demise (12 cases). Thin cord syndrome and umbilical stricture were observed in 9 cases and 4 cases, respectively. Seven of the 15 cases with excessive umbilical hypercoiling showed increased placental fibrin deposition (47% of the cases with hypercoiling), in 4 cases sufficient for rendering the diagnosis of massive perivillous fibrin deposition. Signs of maternal vascular malperfusion (n = 6) and chorangiosis (n = 2) were also detected in cases with hypercoiling. Recurrence of excessive umbilical hypercoiling was observed in 2 families, suggesting a genetic predisposition for the development of this lesion. Extensive hypercoiling could be a hitherto underrecognized pathogenetic factor for the development of massive perivillous fibrin deposition. A high UCI measured in the second trimester by ultrasound may be predictive of fetal hypotrophy, and intensified fetal monitoring is warranted, particularly if there is a history of hypercoiling and adverse fetal outcome.


Assuntos
Morte Fetal/etiologia , Fibrina/metabolismo , Placenta/patologia , Cordão Umbilical/anormalidades , Cordão Umbilical/patologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Placenta/anatomia & histologia , Gravidez , Segundo Trimestre da Gravidez , Terceiro Trimestre da Gravidez
8.
Prenat Diagn ; 40(4): 507-513, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31875322

RESUMO

OBJECTIVE: To assess the influence of abnormal cord insertion (CI) detected by first trimester ultrasonography on the development of twin-to-twin transfusion syndrome (TTTS) in monochorionic diamniotic (MCDA) twins. METHOD: In this retrospective cohort study, consecutive patients with MCDA twins who underwent fetal ultrasound screening in the first trimester between January 2011 and January 2017 were enrolled. The CI sites were evaluated between 11 + 0 and 13 + 6 weeks' gestation. All twin pairs were assigned to the abnormal CI group (twin pair with velamentous cord insertion (VCI) and/or marginal cord insertion (MCI) in one or both twins) or the normal CI group (twin pair with both normal CI). The relationships of adverse outcomes in two groups were analyzed. RESULTS: A total of 109 MCDA twin pairs were examined; 15 cases were classified into the abnormal CI group and 94 cases into the normal CI group. The incidence of TTTS was significantly higher in the abnormal than in the normal CI group (26.7% vs 7.45%, P = .04). In patients who developed TTTS, all donors had VCI. CONCLUSION: Ultrasound evaluation of abnormal CI at 11 + 0 to 13 + 6 weeks' gestation in MCDA twins is valuable in the assessment of the risk for TTTS.


Assuntos
Transfusão Feto-Fetal/epidemiologia , Placenta/diagnóstico por imagem , Cordão Umbilical/anormalidades , Adulto , Feminino , Humanos , Gravidez , Primeiro Trimestre da Gravidez , Estudos Retrospectivos , Gêmeos Monozigóticos , Ultrassonografia Pré-Natal , Cordão Umbilical/diagnóstico por imagem
9.
J Ultrasound Med ; 39(2): 351-358, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31432561

RESUMO

OBJECTIVES: We sought to study potential diagnostic criteria for marginal placental cord insertions as determined by associations with obstetric outcomes. METHODS: This single-center retrospective cohort investigation included singleton gestations delivering from January 1, 2012, to December 31, 2016, and having a standard or detailed fetal ultrasound examination from 18 weeks to 21 weeks 6 days. Cord insertion-to-placental edge distances were used to create a referent comparison group and 3 patient groups: greater than 3.0 cm (comparison); greater than 2.0 to 3.0 cm (group 1); greater than 1.0 to 2.0 cm (group 2); and 1.0 cm or less (group 3). The primary outcome consisted of any one of spontaneous delivery before 37 weeks, fetal growth restriction, oligohydramnios, placental abruption, or intrauterine fetal demise. RESULTS: The numbers of participants and mean distances ± SDs for the comparison group and groups 1 to 3, respectively, were 628 and 4.68 ± 1.17 cm, 106 and 2.52 ± 0.26 cm, 131 and 1.60 ± 0.29 cm, and 77 and 0.36 ± 0.37 cm, respectively. The primary outcome was significantly associated only with cord insertion-to-placental edge distances of 1.0 cm or less (adjusted odds ratio, 3.05; 95% confidence interval, 1.73-5.38). CONCLUSIONS: Marginal cord insertions may be diagnosed when the cord insertion-to-placental edge distance is 1.0 cm or less.


Assuntos
Placenta/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Cordão Umbilical/diagnóstico por imagem , Adulto , Feminino , Humanos , Placenta/anormalidades , Gravidez , Resultado da Gravidez , Segundo Trimestre da Gravidez , Estudos Retrospectivos , Cordão Umbilical/anormalidades
10.
J Perinat Med ; 48(8): 819-824, 2020 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-32769224

RESUMO

Objectives Furcate cord insertion is a rare abnormality affecting approximately 0.1% of all pregnancies. Macroscopically, the umbilical vessels separate before reaching the placenta, lose their Wharton's jelly, and insert at the placenta centrally, eccentrically, or marginally. The aim of this retrospective study was to determine the prevalence of furcate cord insertion more accurately, the pathological characteristics, and clinical outcomes. Methods We conducted a retrospective study of 132 cases of furcate insertion of the umbilical cord using the pathological database of the Charité University Hospital Berlin, Germany, between 1993 and 2016. This included 99 cases, including one termination of pregnancy within our institution and 33 cases from external hospitals. An analysis of the pathological features of the 132 cases and the perinatal outcome of the 98 cases within our institution were performed. Results Furcate cord insertion occurred in 0.16% pregnancies. Of the 132 cases, seven cases of intrauterine fetal deaths were observed. Three of those could be linked to the furcate cord insertion. In two of those cases, single umbilical vessel rupture was identified as the cause of fetal death. Conclusions In most cases of furcate cord insertion, the outcome is good; however, intrauterine fetal death occurs in approximately 1.02% of cases.


Assuntos
Morte Fetal , Doenças Placentárias , Cordão Umbilical , Malformações Vasculares , Adulto , Causas de Morte , Feminino , Morte Fetal/etiologia , Morte Fetal/prevenção & controle , Mortalidade Fetal , Alemanha/epidemiologia , Humanos , Doenças Placentárias/diagnóstico , Doenças Placentárias/etiologia , Gravidez , Resultado da Gravidez/epidemiologia , Prevalência , Estudos Retrospectivos , Ultrassonografia Pré-Natal/métodos , Cordão Umbilical/anormalidades , Cordão Umbilical/diagnóstico por imagem , Cordão Umbilical/lesões , Malformações Vasculares/complicações , Malformações Vasculares/diagnóstico por imagem , Malformações Vasculares/mortalidade , Geleia de Wharton/diagnóstico por imagem
11.
J Perinat Med ; 48(8): 825-828, 2020 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-32769227

RESUMO

Objectives Assisted reproductive technologies (ART) may be associated with placental abnormalities including placenta previa, umbilical cord abnormalities, and placental abruption. Our study evaluates the relationship between ART and placental abnormalities compared with spontaneously conceived controls. Methods An IRB-approved cohort study was conducted including women who delivered between January 2013 and December 2018. We excluded delivery prior to 23 weeks and known fetal anomalies. Patients were matched with controls (2:1) for parity, age, and mode of delivery. Controls were women who had spontaneously conceived and delivered immediately preceding and following the index delivery. The primary outcome was placental abnormalities found on both antenatal ultrasound and pathology in ART gestations compared with spontaneously conceived gestations. Results There were 120 ART pregnancies and 240 matched control pregnancies identified. The groups were similar for parity, BMI, comorbidities, number of multiples, mode of delivery, and female newborns. The ART group had a higher maternal age (37.1±5 y vs. 30.0±5 y; p<0.001), greater preterm birth (29 vs. 6%; p<0.001), and lower BW (2,928±803 g vs. 3,273±586 g; p<0.001). The ART group had a higher incidence of placenta previa on ultrasound (4.0 vs. 0.4%, p=0.01), adherent placentas at delivery (3 vs. 0% p=0.014), placental abruption (2 vs. 0%; p=0.04), as well as an increased rate of velamentous cord insertion (12 vs. 3%, p<0.001) and marginal cord insertion (28 vs. 15%, p=0.002). ART demonstrated a two-fold likelihood of abnormal placental pathology. Conclusions ART is associated with increased rate of placental abnormalities, including abnormal umbilical cord insertion and increased rates of adherent placentation. This information may be beneficial in planning and surveillance in patients with ART pregnancies.


Assuntos
Descolamento Prematuro da Placenta , Parto Obstétrico , Placenta Prévia , Técnicas de Reprodução Assistida/estatística & dados numéricos , Ultrassonografia Pré-Natal/métodos , Cordão Umbilical , Descolamento Prematuro da Placenta/diagnóstico , Descolamento Prematuro da Placenta/epidemiologia , Adulto , Índice de Massa Corporal , Comorbidade , Parto Obstétrico/métodos , Parto Obstétrico/estatística & dados numéricos , Feminino , Humanos , Recém-Nascido , Paridade , Placenta/diagnóstico por imagem , Placenta Prévia/diagnóstico , Placenta Prévia/epidemiologia , Gravidez , Resultado da Gravidez/epidemiologia , Estudos Retrospectivos , Medição de Risco/métodos , Cordão Umbilical/anormalidades , Cordão Umbilical/diagnóstico por imagem , Estados Unidos/epidemiologia
12.
J Obstet Gynaecol Res ; 46(1): 173-175, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31646709

RESUMO

Cesarean section en caul could cause neonatal anemia, but the mechanism remains unknown. We demonstrate an association between neonatal anemia and velamentous insertion of the umbilical cord in cesarean section en caul, and suggest a way to make this procedure safer. We performed cesarean section en caul, but the placenta and the membrane sac were delivered separately. The neonate was severely anemic. The umbilical cord was attached to the membrane and the blood vessel connecting the umbilical cord and placenta was torn. The amniotic membrane covering the placental surface had peeled away. Velamentous insertion of the umbilical cord could be a cause of neonatal anemia associated with cesarean section en caul.


Assuntos
Anemia Neonatal/etiologia , Cesárea/efeitos adversos , Cordão Umbilical/anormalidades , Adulto , Âmnio/cirurgia , Cesárea/métodos , Feminino , Humanos , Recém-Nascido , Gravidez , Fatores de Risco , Cordão Umbilical/cirurgia
13.
Am J Perinatol ; 37(1): 104-111, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31756760

RESUMO

OBJECTIVES: This article prospectively examines the use of ultrasound for antenatal detection of abnormal placental cord insertion (PCI) and compares the antenatal classification with delivered placental classification. STUDY DESIGN: This prospective cohort study examined 277 singleton pregnancies in a tertiary center. Scans were performed between 10 and 14, 18 and 22, and 32 and 34 weeks where PCI site was identified and its shortest distance to margin measured. Standardized images of delivered placentas were taken and digitally measured. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of antenatal classification compared with delivered placental classification were calculated. RESULTS: Abnormal PCI (distance < 2 cm from margin) was confirmed in 30/277 (11%) placentas at delivery. Note that 102/277 (37%) of PCI sites were classified as abnormal in the first trimester (T1), 43/277 (16%) in the second trimester (T2), and 28/277 (10%) in the third trimester (T3). Sensitivity (73%) and specificity (91%) were highest at T2. The PPVs were low (22% in T1, 51% in T2, and 64% in T3) and the NPVs were high (96% in T1 and 97% in both T2 and T3) for all scans. CONCLUSION: Abnormal PCI can be detected antenatally with optimal agreement with postnatal classification in T2. However, the incidence is overestimated at early scans with low PPVs.


Assuntos
Placenta/anormalidades , Ultrassonografia Pré-Natal , Cordão Umbilical/anormalidades , Adulto , Estudos de Viabilidade , Feminino , Humanos , Placenta/anatomia & histologia , Placenta/diagnóstico por imagem , Gravidez , Trimestres da Gravidez , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade , Cordão Umbilical/diagnóstico por imagem
14.
Med Sci Monit ; 25: 3170-3180, 2019 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-31036798

RESUMO

The umbilical cord is the only connection between the mother and the fetus, through which it is possible to transport respiratory gases, nutrients, and metabolites. Thanks to the umbilical cord, the fetus has also the ability to move, which is necessary for its proper psychomotor development. The correct structure and function of umbilical vessels and the entire umbilical cord determine the possibility of proper development and survival of the fetus. Umbilical cord anatomy should be assessed in the ultrasound examination in the first trimester. It is of vital importance to confirm the correct number of umbilical vessels and their intra-abdominal course, as well as carefully assessing the abdominal and placental insertion sites. In the latter half of pregnancy, the use of the Doppler imaging enables assessment of the function of the fetal-placental vessels, thus providing valuable information about the condition of the fetus.


Assuntos
Diagnóstico Pré-Natal/métodos , Ultrassonografia Pré-Natal/métodos , Cordão Umbilical/anormalidades , Cordão Umbilical/diagnóstico por imagem , Feminino , Sofrimento Fetal/diagnóstico por imagem , Feto/diagnóstico por imagem , Feto/metabolismo , Humanos , Gravidez
15.
J Ultrasound Med ; 38(12): 3131-3140, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31144344

RESUMO

Abnormalities of the placenta and umbilical cord have been associated with adverse pregnancy outcomes. Antenatal detection of placental and umbilical cord abnormalities using ultrasound (US) imaging is now gaining popularity with the advancements in obstetric US. This article reviews the use of 2-dimensional obstetric US as a tool to measure and assess placental and umbilical cord morphometry. It highlights the potential role of placental and umbilical cord morphometry as a valuable component of the screening tool for high risk pregnancies and identifies the need for further research to examine its feasibility.


Assuntos
Placenta/anormalidades , Placenta/diagnóstico por imagem , Ultrassonografia Pré-Natal , Cordão Umbilical/anormalidades , Cordão Umbilical/diagnóstico por imagem , Feminino , Humanos , Gravidez
16.
Fetal Pediatr Pathol ; 38(4): 359-360, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30947594

RESUMO

Background: Umbilical cord haematomas may result in mortality or significant morbidity due to interference with vital fetal blood flow. Case report: We present a massive umbilical haematoma in a asymptomatic neonate without risk factors or hypoxic event. Conclusion: Although massive umbilical haematomas may result in miscarriage and fetal hypoxia, in some cases there may be no complications.


Assuntos
Hematoma/diagnóstico , Cordão Umbilical/patologia , Feminino , Hematoma/complicações , Hemorragia , Humanos , Hipóxia , Recém-Nascido , Masculino , Gravidez , Fatores de Risco , Ultrassonografia Pré-Natal , Cordão Umbilical/anormalidades
17.
Am J Med Genet A ; 176(5): 1222-1224, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29681107

RESUMO

Proteus syndrome (PS) is characterized by the progressive, segmental, or patchy overgrowth of the skin, and other tissues. This is the first case report of recurrent severe insulin-independent hypoglycemia in an infant with PS. Somatic p.E17K of AKT1 mutation was confirmed. The patient also had a giant umbilical cord, which has not yet been reported in PS.


Assuntos
Hipoglicemia/sangue , Fenótipo , Síndrome de Proteu/sangue , Síndrome de Proteu/diagnóstico , Cordão Umbilical/anormalidades , Biomarcadores , Análise Mutacional de DNA , Humanos , Lactente , Imageamento por Ressonância Magnética , Masculino , Mutação , Diagnóstico Pré-Natal , Síndrome de Proteu/genética , Proteínas Proto-Oncogênicas c-akt/genética , Cordão Umbilical/diagnóstico por imagem
18.
J Perinat Med ; 46(9): 1040-1047, 2018 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-29267174

RESUMO

OBJECTIVE: To clarify and compare if the neurological outcomes of fetal growth restriction (FGR) cases with abnormal cord insertion (CI) are associated with a higher risk of a poor neurological outcome in subjects aged 3 years or less versus those with normal CI. METHODS: A multicenter retrospective cohort study was conducted among patients with a birth weight lower than the 3rd percentile, based on the standard reference values for Japanese subjects after 22 weeks' gestation, who were treated at a consortium of nine perinatal centers in Japan between June 2005 and March 2011. Patients whose birth weights were less than the 3rd percentile and whose neurological outcomes from birth to 3 years of age could be checked from their medical records were analyzed. The relationship between abnormal CI and neurological outcomes was analyzed. Univariate and multivariate models of multivariate logistic regression were employed to estimate the raw and odds ratio (OR) with 95% confidence intervals comparing marginal (MCI) and velamentous cord insertion (VCI) to normal CI. RESULTS: Among 365 neonates, 63 cases of MCI and 14 cases of VCI were observed. After excluding 24 cases with neonatal or infant death from the total FGR population, the assessment of the outcomes of the infants aged 3 years or younger showed the following rates of neurological complications: 7.3% (n=25) for cerebral palsy, 8.8% (n=30) for developmental disorders, 16.7% (n=57) for small-for-gestational-age short stature (SGA), 0.6% (n=2) for impaired hearing, 0.9% (n=3) for epilepsy, 1.2% (n=4). The ORs (95% confidence intervals) based on multivariate analysis were as follows: cerebral palsy=10.1 (2.4-41.5) in the VCI group and 4.3 (1.6-11.9) in the MCI group, developmental disorders=6.7 (1.7-26) in the VCI group and 3.9 (1.1-14.2) in the single umbilical artery (SUA) group, 5.1 (1.4-18.7) for birth weight <1000 g and 2.8 (1.2-6.7) for placental weight <200 g. CONCLUSIONS: The present results indicate that growth-restricted fetuses diagnosed with a birth weight below the 3rd percentile exhibiting abnormal umbilical CI are at a high risk for poor neurological outcomes, including cerebral palsy and/or developmental disorders.


Assuntos
Peso ao Nascer , Paralisia Cerebral , Desenvolvimento Infantil , Retardo do Crescimento Fetal , Doenças do Sistema Nervoso , Cordão Umbilical , Paralisia Cerebral/diagnóstico , Paralisia Cerebral/epidemiologia , Paralisia Cerebral/etiologia , Pré-Escolar , Feminino , Retardo do Crescimento Fetal/diagnóstico , Retardo do Crescimento Fetal/epidemiologia , Idade Gestacional , Humanos , Lactente , Recém-Nascido , Japão/epidemiologia , Masculino , Doenças do Sistema Nervoso/diagnóstico , Doenças do Sistema Nervoso/epidemiologia , Doenças do Sistema Nervoso/etiologia , Gravidez , Nascimento Prematuro/epidemiologia , Prognóstico , Estudos Retrospectivos , Medição de Risco , Ultrassonografia Pré-Natal/métodos , Artérias Umbilicais/diagnóstico por imagem , Cordão Umbilical/anormalidades , Cordão Umbilical/diagnóstico por imagem
19.
J Obstet Gynaecol Res ; 44(4): 623-629, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29316011

RESUMO

AIM: We evaluated risk factors for birthweight discordance in monochorionic diamniotic (MCDA) twin pregnancies without twin-twin transfusion syndrome (TTTS). METHODS: We investigated all MCDA twin placentas injected with colored dye at our institution between 2007 and 2015. We excluded pairs of twins with TTTS, fetal demise, or severe fetal malformation. All pairs of twins were assigned to the discordant group (birthweight discordance ≥ 25%) or the concordant group (birthweight discordance < 25%). In each pair of twins, we described vascular anastomoses as either arterioarterial, venovenous (VV), or arterial-venous, and abnormal umbilical cord insertion as either marginal or velamentous. We also recorded placental sharing discordance. RESULTS: A total of 150 placentas were analyzed. The incidence of VV anastomosis in the discordant group (40%) was significantly higher than that in the concordant group (12%, P = 0.005). Unilateral abnormal umbilical cord insertion was significantly more common in the discordant group (85%) than in the concordant group (38%, P < 0.001). Placental sharing discordance was seen more frequently in the discordant group than in the concordant group. Multiple logistic analysis revealed that VV anastomosis (odds ratio: 4.7; 95% confidence interval: 1.2-18.6, P < 0.01) and unilateral abnormal umbilical cord insertion of the smaller twin (odds ratio: 5.7; 95% confidence interval: 1.4-22.9, P < 0.01) were independent risk factors for birthweight discordance. CONCLUSION: VV anastomoses and unilateral abnormal umbilical cord insertion of the smaller twin are independent risk factors for birthweight discordance in MCDA twin pregnancies without TTTS.


Assuntos
Peso ao Nascer , Doenças em Gêmeos/patologia , Doenças do Recém-Nascido/patologia , Gravidez de Gêmeos , Gêmeos Monozigóticos , Cordão Umbilical/anormalidades , Fístula Vascular/patologia , Veias/anormalidades , Adolescente , Adulto , Doenças em Gêmeos/epidemiologia , Feminino , Humanos , Recém-Nascido , Doenças do Recém-Nascido/epidemiologia , Gravidez , Fatores de Risco , Fístula Vascular/epidemiologia , Adulto Jovem
20.
Pediatr Rev ; 39(7): 332-341, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29967078

RESUMO

The umbilical cord, a vital conduit between the placenta and the fetus, loses much of its significance after birth. However, newborns can often present with various abnormalities of the umbilicus, such as benign granulomas or more serious lesions due to persistent remnants, many of which can change the normal course of cord separation and may be associated with significant morbidities if left unrecognized and uncorrected. Although not uncommon, sanguineous drainage from the umbilical stump can be quite alarming to new parents. Parental counseling regarding normal umbilical cord changes, as well as abnormal findings, such as discharge and skin changes, are important for the recognition and timely treatment of potentially significant umbilical cord disorders.


Assuntos
Complicações na Gravidez/diagnóstico , Cordão Umbilical/anormalidades , Feminino , Humanos , Recém-Nascido , Gravidez , Complicações na Gravidez/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA