Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38.790
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Methods ; 229: 63-70, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38917960

RESUMO

Studying the molecular and immunological basis of allergic diseases often requires purified native allergens. The methodologies for protein purification are usually difficult and may not be completely successful. The objective of this work was to describe a methodology to purify allergens from their natural source, while maintaining their native form. The purification strategy consists of a three-step protocol and was used for purifying five specific allergens, Ole e 1, Amb a 1, Alt a 1, Bet v 1 and Cup a 1. Total proteins were extracted in PBS (pH 7.2). Then, the target allergens were pre-purified and enriched by salting-out using increasing concentrations of ammonium sulfate. The allergens were further purified by anion exchange chromatography. Purification of Amb a 1 required an extra step of cation exchange chromatography. The detection of the allergens in the fractions obtained were screened by SDS-PAGE, and Western blot when needed. Further characterization of purified Amb a 1 was performed by mass spectrometry. Ole e 1, Alt a 1, Bet v 1 and Cup a 1 were obtained at > 90 % purity. Amb a 1 was obtained at > 85 % purity. Overall, we propose an easy-to-perform purification approach that allows obtaining highly pure allergens. Since it does not involve neither chaotropic nor organic reagents, we anticipate that the structural and biological functions of the purified molecule remain intact. This method provides a basis for native allergen purification that can be tailored according to specific needs.


Assuntos
Alérgenos , Alérgenos/química , Alérgenos/isolamento & purificação , Alérgenos/imunologia , Cromatografia por Troca Iônica/métodos , Eletroforese em Gel de Poliacrilamida/métodos , Humanos , Sulfato de Amônio/química
2.
J Proteome Res ; 23(4): 1221-1231, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38507900

RESUMO

Proteins usually execute their biological functions through interactions with other proteins and by forming macromolecular complexes, but global profiling of protein complexes directly from human tissue samples has been limited. In this study, we utilized cofractionation mass spectrometry (CF-MS) to map protein complexes within the postmortem human brain with experimental replicates. First, we used concatenated anion and cation Ion Exchange Chromatography (IEX) to separate native protein complexes in 192 fractions and then proceeded with Data-Independent Acquisition (DIA) mass spectrometry to analyze the proteins in each fraction, quantifying a total of 4,804 proteins with 3,260 overlapping in both replicates. We improved the DIA's quantitative accuracy by implementing a constant amount of bovine serum albumin (BSA) in each fraction as an internal standard. Next, advanced computational pipelines, which integrate both a database-based complex analysis and an unbiased protein-protein interaction (PPI) search, were applied to identify protein complexes and construct protein-protein interaction networks in the human brain. Our study led to the identification of 486 protein complexes and 10054 binary protein-protein interactions, which represents the first global profiling of human brain PPIs using CF-MS. Overall, this study offers a resource and tool for a wide range of human brain research, including the identification of disease-specific protein complexes in the future.


Assuntos
Proteínas , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Proteínas/química , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia por Troca Iônica/métodos , Encéfalo , Proteoma/análise
3.
J Proteome Res ; 23(7): 2315-2322, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38913967

RESUMO

Native top-down mass spectrometry (nTDMS) allows characterization of protein structure and noncovalent interactions with simultaneous sequence mapping and proteoform characterization. The majority of nTDMS studies utilize purified recombinant proteins, with significant challenges hindering application to endogenous systems. To perform native top-down proteomics (nTDP), where endogenous proteins from complex biological systems are analyzed by nTDMS, it is essential to separate proteins under nondenaturing conditions. However, it remains difficult to achieve high resolution with MS-compatible online chromatography while preserving protein tertiary structure and noncovalent interactions. Herein, we report the use of online mixed-bed ion exchange chromatography (IEC) to enable separation of endogenous proteins from complex mixtures under nondenaturing conditions, preserving noncovalent interactions for nTDP analysis. We have successfully detected large proteins (>146 kDa) and identified endogenous metal-binding and oligomeric protein complexes in human heart tissue lysate. The use of a mixed-bed stationary phase allowed retention and elution of proteins over a wide range of isoelectric points without altering the sample or mobile phase pH. Overall, our method provides a simple online IEC-MS platform that can effectively separate proteins from complex mixtures under nondenaturing conditions and preserve higher-order structure for nTDP applications.


Assuntos
Proteômica , Cromatografia por Troca Iônica/métodos , Humanos , Proteômica/métodos , Miocárdio/química , Espectrometria de Massas/métodos , Misturas Complexas/química , Proteínas/química , Proteínas/análise , Proteínas/isolamento & purificação
4.
J Proteome Res ; 23(7): 2431-2440, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38965920

RESUMO

Alpha-1-acid glycoprotein (AGP) is a heterogeneous glycoprotein fulfilling key roles in many biological processes, including transport of drugs and hormones and modulation of inflammatory and immune responses. The glycoform profile of AGP is known to change depending on (patho)physiological states such as inflammatory diseases or pregnancy. Besides complexity originating from five N-glycosylation sites, the heterogeneity of the AGP further expands to genetic variants. To allow in-depth characterization of this intriguing protein, we developed a method using anion exchange chromatography (AEX) coupled to mass spectrometry (MS) revealing the presence of over 400 proteoforms differing in their glycosylation or genetic variants. More precisely, we could determine that AGP mainly consists of highly sialylated higher antennary structures with on average 16 sialic acids and 0 or 1 fucose per protein. Interestingly, a slightly higher level of fucosylation was observed for AGP1 variants compared to that of AGP2. Proteoform assignment was supported by integrating data from complementary MS-based approaches, including AEX-MS of an exoglycosidase-treated sample and glycopeptide analysis after tryptic digestion. The developed analytical method was applied to characterize AGP from plasma of women during and after pregnancy, revealing differences in glycosylation profiles, specifically in the number of antennae, HexHexNAc units, and sialic acids.


Assuntos
Orosomucoide , Humanos , Orosomucoide/metabolismo , Orosomucoide/química , Feminino , Gravidez , Cromatografia por Troca Iônica/métodos , Glicosilação , Espectrometria de Massas/métodos , Fucose/química , Fucose/metabolismo , Glicopeptídeos/análise , Glicopeptídeos/química , Glicopeptídeos/sangue
5.
Anal Chem ; 96(31): 12801-12808, 2024 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-39051724

RESUMO

Plasmid DNA (pDNA) is an essential tool in genetic engineering that has gained prevalence in cell and gene therapies. Plasmids exist as supercoiled (SC), open circular (OC), and linear forms. Plasmid multimerization can also occur during the manufacturing process. Even though the SC forms are thought to provide optimal knock-in (KI) efficiency, there is no strong consensus on the effect of the topological forms and multimers on the functional activity. In addition, the results obtained for conventional pDNAs (>5 kbp) do not necessarily translate to smaller pDNAs (∼3 kbp). In this study, a workflow was developed for the analytical and functional characterization of pDNA topological forms and multimers. An anion exchange chromatography (AEC) method was first developed to quantify the topological forms and multimers. Four AEC columns were initially compared, one of which was found to provide superior chromatographic performance. The effect of mobile phase pH, various salts, column temperature, and acetonitrile content on the separation performance was systematically studied. The method performance, including precision and accuracy, was evaluated. The final AEC method was compared to capillary gel electrophoresis (CGE) by analyzing several pDNA sequences and lots. A forced degradation study revealed unexpectedly high degradation of the SC forms. Finally, the KI efficiency was compared for the SC and OC forms, and the multimers.


Assuntos
Plasmídeos , Plasmídeos/genética , Cromatografia por Troca Iônica , Eletroforese Capilar , DNA/química , Concentração de Íons de Hidrogênio
6.
Anal Chem ; 96(24): 9849-9858, 2024 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-38836774

RESUMO

The scarcity and dynamic nature of phosphotyrosine (pTyr)-modified proteins pose a challenge for researching protein complexes with pTyr modification, which are assembled through multiple protein-protein interactions. We developed an integrated complex-centric platform for large-scale quantitative profiling of pTyr signaling complexes based on cofractionation/mass spectrometry (CoFrac-MS) and a complex-centric algorithm. We initially constructed a trifunctional probe based on pTyr superbinder (SH2-S) for specifically binding and isolation of intact pTyr protein complexes. Then, the CoFrac-MS strategy was employed for the identification of pTyr protein complexes by integrating ion exchange chromatography in conjunction with data independent acquisition mass spectrometry. Furthermore, we developed a novel complex-centric algorithm for quantifying protein complexes based on the protein complex elution curve. Utilizing this algorithm, we effectively quantified 216 putative protein complexes. We further screened 21 regulated pTyr protein complexes related to the epidermal growth factor signal. Our study engenders a comprehensive framework for the intricate examination of pTyr protein complexes and presents, for the foremost occasion, a quantitative landscape delineating the composition of pTyr protein complexes in HeLa cells.


Assuntos
Algoritmos , Espectrometria de Massas , Fosfotirosina , Transdução de Sinais , Fosfotirosina/metabolismo , Fosfotirosina/análise , Fosfotirosina/química , Humanos , Células HeLa , Cromatografia por Troca Iônica/métodos
7.
Anal Chem ; 96(22): 8880-8885, 2024 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-38771719

RESUMO

The characterization of proteins and complexes in biological systems is essential to establish their critical properties and to understand their unique functions in a plethora of bioprocesses. However, it is highly difficult to analyze low levels of intact proteins in their native states (especially those exceeding 30 kDa) with liquid chromatography (LC)-mass spectrometry (MS). Herein, we describe for the first time the use of nanoflow ion-exchange chromatography directly coupled with native MS to resolve mixtures of intact proteins. Reference proteins and protein complexes with molecular weights between 10 and 150 kDa and a model cell lysate were separated using a salt-mediated pH gradient method with volatile additives. The method allowed for low detection limits (0.22 pmol of monoclonal antibodies), while proteins presented nondenatured MS (low number of charges and limited charge state distributions), and the oligomeric state of the complexes analyzed was mostly kept. Excellent chromatographic separations including the resolution of different proteoforms of large proteins (>140 kDa) and a peak capacity of 82 in a 30 min gradient were obtained. The proposed setup and workflows show great potential for analyzing diverse proteoforms in native top-down proteomics, opening unprecedented opportunities for clinical studies and other sample-limited applications.


Assuntos
Espectrometria de Massas , Cromatografia por Troca Iônica/métodos , Espectrometria de Massas/métodos , Proteínas/análise , Proteínas/química , Nanotecnologia , Humanos , Proteômica/métodos , Anticorpos Monoclonais/química , Anticorpos Monoclonais/análise
8.
Electrophoresis ; 45(3-4): 234-243, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37847878

RESUMO

In this study, methods for analyzing inorganic ions and carbohydrates in cardioplegia and nephroplegia solutions were developed and validated using ion chromatography with both conductivity and pulsed amperometric detection. The inorganic ions such as sodium, potassium, and calcium were separated by a cation-exchange column with 27 mM methanesulfonic acid as mobile phase at 0.5 mL/min. The anion (chloride) and carbohydrates (mannitol and glucose) were analyzed by an anion-exchange column using a mobile phase of 20 mM sodium hydroxide at 1.0 mL/min. The methods showed a high sensitivity for all analytes, with quantification limits from 0.0002 to 0.06 mg/L. Good linearities between the peak areas and concentrations were found for all analytes within the selected concentration range (R2  > 0.999). Relative standard deviation values for repeatability and interday precision were 0.1%-1.0% and 0.7%-1.6%, respectively. The accuracy was validated by determining the percentage recovery, which was between 98.0% and 101.3% for all analytes, indicating good accuracy of the methods. The robustness was verified by using an experimental design. Finally, real samples were analyzed to determine the content of the analytes. All assay values were between 96.8% and 102.5%.


Assuntos
Carboidratos , Glucose , Cromatografia por Troca Iônica/métodos , Carboidratos/análise , Ânions , Parada Cardíaca Induzida
9.
Electrophoresis ; 45(5-6): 369-379, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38059740

RESUMO

Adenoviruses are well-known viral vectors that have been previously used in gene therapy and as a vaccine-delivery vehicle for humans and animals. During the COVID-19 pandemic, it gained renewed attention, but at the same time, it raised concerns due to side effects observed with some of the resulting vaccines administered to patients. It has been indicated that these side effects might be attributed to impurities present in the final product. Therefore, constant enhancement of the vaccine purity and further improvement of impurity detection methods are needed. In this work, we showcase an example of industry-relevant adenovirus bioprocess optimization. Our data show the effect of upstream parameters on the bioburden introduced to the downstream process. We provide an example of process optimization using a combination of the PATfix analytical method, ddPCR, infectivity, total DNA, and total protein analyses to optimize cell density, multiplicity of infection, and length of production. Additionally, we provide data illustrating the robustness of the convective interaction media quaternary amine monolithic chromatography step. This anion exchange strategy was shown to remove over 99% of protein and DNA impurities, including those unable to be addressed by tangential flow filtration, while maintaining high adenovirus recoveries.


Assuntos
Adenoviridae , Vacinas , Animais , Humanos , Pandemias , Cromatografia por Troca Iônica/métodos , DNA
10.
Microb Pathog ; 192: 106706, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38763316

RESUMO

Mannheimiahaemolytica is an opportunistic agent of the respiratory tract of bovines, a member of the Pasteurellaceae family, and the causal agent of fibrinous pleuropneumonia. This bacterium possesses different virulence factors, allowing it to colonize and infect its host. The present work describes the isolation and characterization of a serine protease secreted by M. haemolytica serotype 1. This protease was isolated from M. haemolytica cultured media by precipitation with 50 % methanol and ion exchange chromatography on DEAE-cellulose. It is a 70-kDa protease able to degrade sheep and bovine fibrinogen or porcine gelatin but not bovine IgG, hemoglobin, or casein. Mass spectrometric analysis indicates its identity with protease IV of M. haemolytica. The proteolytic activity was active between pH 5 and 9, with an optimal pH of 8. It was stable at 50 °C for 10 min but inactivated at 60 °C. The sera of bovines with chronic or acute pneumonia recognized this protease. Still, it showed no cross-reactivity with rabbit hyperimmune serum against the secreted metalloprotease from Actinobacilluspleuropneumoniae, another member of the Pasteurellaceae family. M. haemolytica secreted proteases could contribute to the pathogenesis of this bacterium through fibrinogen degradation, a characteristic of this fibrinous pleuropneumonia.


Assuntos
Fibrinogênio , Mannheimia haemolytica , Serina Proteases , Animais , Mannheimia haemolytica/enzimologia , Ovinos , Bovinos , Fibrinogênio/metabolismo , Concentração de Íons de Hidrogênio , Serina Proteases/metabolismo , Serina Proteases/isolamento & purificação , Temperatura , Proteólise , Peso Molecular , Gelatina/metabolismo , Estabilidade Enzimática , Proteínas de Bactérias/metabolismo , Proteínas de Bactérias/isolamento & purificação , Espectrometria de Massas , Cromatografia por Troca Iônica , Suínos , Fatores de Virulência/metabolismo , Fatores de Virulência/isolamento & purificação
11.
Biotechnol Bioeng ; 121(5): 1702-1715, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38230585

RESUMO

Digital twin (DT) is a virtual and digital representation of physical objects or processes. In this paper, this concept is applied to dynamic control of the collection window in the ion exchange chromatography (IEC) toward sample variations. A possible structure of a feedforward model-based control DT system was proposed. Initially, a precise IEC mechanistic model was established through experiments, model fitting, and validation. The average root mean square error (RMSE) of fitting and validation was 8.1% and 7.4%, respectively. Then a model-based gradient optimization was performed, resulting in a 70.0% yield with a remarkable 11.2% increase. Subsequently, the DT was established by systematically integrating the model, chromatography system, online high-performance liquid chromatography, and a server computer. The DT was validated under varying load conditions. The results demonstrated that the DT could offer an accurate control with acidic variants proportion and yield difference of less than 2% compared to the offline analysis. The embedding mechanistic model also showed a positive predictive performance with an average RMSE of 11.7% during the DT test under >10% sample variation. Practical scenario tests indicated that tightening the control target could further enhance the DT robustness, achieving over 98% success rate with an average yield of 72.7%. The results demonstrated that the constructed DT could accurately mimic real-world situations and perform an automated and flexible pooling in IEC. Additionally, a detailed methodology for applying DT was summarized.


Assuntos
Anticorpos Monoclonais , Cromatografia Líquida de Alta Pressão/métodos , Anticorpos Monoclonais/química , Cromatografia por Troca Iônica/métodos
12.
Biotechnol Bioeng ; 121(2): 719-734, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37942560

RESUMO

Recombinant adeno-associated viral vectors (rAAVs) have become an industry-standard technology in the field of gene therapy, but there are still challenges to be addressed in their biomanufacturing. One of the biggest challenges is the removal of capsid species other than that which contains the gene of interest. In this work, we develop a mechanistic model for the removal of empty capsids-those that contain no genetic material-and enrichment of full rAAV using anion-exchange membrane chromatography. The mechanistic model was calibrated using linear gradient experiments, resulting in good agreement with the experimental data. The model was then applied to optimize the purification process through maximization of yield studying the impact of mobile phase salt concentration and pH, isocratic wash and elution length, flow rate, percent full (purity) requirement, loading density (challenge), and the use of single-step or two-step elution modes. A solution from the optimization with purity of 90% and recovery yield of 84% was selected and successfully validated, as the model could predict the recovery yield with remarkable fidelity and was able to find process conditions that led to significant enrichment. This is, to the best of our knowledge, the first case study of the application of de novo mechanistic modeling for the enrichment of full capsids in rAAV manufacturing, and it serves as demonstration of the potential of mechanistic modeling in rAAV process development.


Assuntos
Dependovirus , Vetores Genéticos , Cromatografia por Troca Iônica/métodos , Dependovirus/genética , Terapia Genética , Capsídeo/química
13.
Biotechnol Bioeng ; 121(8): 2500-2523, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38807330

RESUMO

Recombinant adeno-associated virus, serotype 9 (rAAV9) has shown promise as a gene therapy vector for muscle and central nervous diseases. High-dose requirements of these therapies present critical safety considerations and biomanufacturing challenges. Notably, the reduction of empty capsids (ECs), which lack therapeutic transgene, from rAAV9 products is critical to maximize efficacy. Removal of rAAV ECs from full capsids is a major downstream challenge because of their highly similar biophysical characteristics. Ultracentrifugation (UC) reduces ECs but is laborious and difficult to scale. In this paper, to replace a poorly scalable UC process, we developed an anion exchange (AEX) chromatography for rAAV9 EC reduction from full capsids. AEX load preparation by dilution incurred major product loss. The addition of histidine and surfactants to dilution buffers increased yield and reduced aggregation. Elution salts were screened and sodium acetate was found to maximize yield and EC reduction. The most promising load dilution buffer and elution salt were used in combination to form an optimized AEX method. The process reduced ECs three-fold, demonstrated robustness to a broad range of EC load challenges, and was scaled for large-scale manufacture. Compared to UC, the AEX method simplified scale-up, reduced ECs to comparable levels (20%), afforded similar purity and product quality, and increased yield by 14%.


Assuntos
Capsídeo , Dependovirus , Terapia Genética , Dependovirus/genética , Terapia Genética/métodos , Capsídeo/química , Capsídeo/metabolismo , Humanos , Vetores Genéticos/genética , Cromatografia por Troca Iônica/métodos , Ultracentrifugação
14.
Biotechnol Bioeng ; 121(9): 2936-2951, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38874319

RESUMO

The demand for Lentiviral Vector (LV) drug substance is increasing. However, primary capture using convective anion-exchange chromatography remains a significant manufacturing challenge. This stems from a poor understanding of the complex adsorption behaviors linked to LVs intricate and variable structure, such as high binding heterogeneity which is typically characterized by a gradient elution profile consisting of two peaks. Understanding which LV structural components drive these phenomena is therefore crucial for rational process design. This work identifies the key LV envelope components responsible for binding to quaternary-amine membrane adsorbents. Eliminating the pseudotype protein (Vesicular Stomatitis Virus G glycoprotein [VSV-G]) did not impact the heterogenous two-peak elution profile, suggesting it is not a major binding species. Digestion of envelope glycosaminoglycans (GAGs), present on proteoglycans, leads to a dramatic reduction in the proportion of vector eluted in peak 2, decreasing from 50% to 3.1%, and a threefold increase in peak 1 maximum. Data from reinjection experiments point towards interparticle envelope heterogeneity from discrete LV populations, where the two-peak profile emerges from a subpopulation of LVs interacting via highly charged GAGs (peak 2) along with a weaker binding population likely interacting through the phospholipid membrane and envelope protein (peak 1).


Assuntos
Vetores Genéticos , Lentivirus , Cromatografia por Troca Iônica/métodos , Lentivirus/genética , Vetores Genéticos/genética , Vetores Genéticos/química , Vetores Genéticos/metabolismo , Humanos , Proteínas do Envelope Viral/genética , Proteínas do Envelope Viral/química , Proteínas do Envelope Viral/metabolismo
15.
Pharm Res ; 41(7): 1443-1454, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38951451

RESUMO

PURPOSE: Chemical modifications in monoclonal antibodies can change hydrophobicity, charge heterogeneity as well as conformation, which eventually can impact their physical stability. In this study, the effect of the individual charge variants on physical stability and aggregation propensity in two different buffer conditions used during downstream purification was investigated. METHODS: The charge variants were separated using semi-preparative cation exchange chromatography and buffer exchanged in the two buffers with pH 6.0 and 3.8. Subsequently each variant was analysed for size heterogeneity using size exclusion chromatography and dynamic light scattering, conformational stability, colloidal stability, and aggregation behaviour under accelerated stability conditions. RESULTS: Size variants in each charge variant were similar in both pH conditions when analyzed without extended storage. However, conformational stability was lower at pH 3.8 than pH 6.0. All charge variants showed similar apparent melting temperature at pH 6.0. In contrast, at pH 3.8 variants A3, A5, B2, B3 and B4 display lower Tm, suggesting reduced conformational stability. Further, A2, A3 and A5 exhibit reduced colloidal stability at pH 3.8. In general, acidic variants are more prone to aggregation than basic variants. CONCLUSION: Typical industry practice today is to examine in-process intermediate stability with acidic species and basic species taken as a single category each. We suggest that perhaps stability evaluation needs to be performed at specie level as different acidic or basic species have different stability and this knowledge can be used for clever designing of the downstream process to achieve a stable product.


Assuntos
Anticorpos Monoclonais , Estabilidade Proteica , Anticorpos Monoclonais/química , Concentração de Íons de Hidrogênio , Estabilidade de Medicamentos , Conformação Proteica , Agregados Proteicos , Cromatografia por Troca Iônica/métodos , Interações Hidrofóbicas e Hidrofílicas , Cromatografia em Gel , Coloides/química , Produtos Biológicos/química , Humanos , Soluções Tampão
16.
Anal Bioanal Chem ; 416(20): 4503-4517, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38896239

RESUMO

Residues of various highly polar pesticides and their metabolites are commonly found in numerous food products. Some of these compounds, such as glyphosate, are not only used in large amounts in agriculture, but are also controversially discussed in public. Here, we present a method, employing ion chromatography (IC) coupled to tandem mass spectrometry (IC-MS/MS), for the analyses of glyphosate, aminomethyl phosphonic acid (AMPA), N-acetyl-glyphosate (NAGly), fosetyl, and 10 further highly polar pesticides and metabolites in various plant and animal matrices following a minimal sample preparation by means of the QuPPe method. Thorough investigations showed that an AS19 column enabled the analysis of all 14 compounds within 30 min. The best sensitivity could be obtained with the make-up solvent acetonitrile being admixed to the mobile phase at a 1:2 flow rate ratio. Matrix effects were thoroughly studied in terms of ion suppression and retention time shifts. Conductivity detection was used to monitor elution profiles of matrix co-extractives in comparison with matrix effect profiles obtained by continuous post-column infusion of a mix with 13 highly polar pesticides and metabolites. These tests indicated that a fivefold dilution of QuPPe extracts was suitable for the routine analysis of samples for MRL-conformity, as it considerably reduced matrix effects maintaining sufficient sensitivity and high recovery rates in eight different commodities. The suitability of the final method for its application in routine analysis was verified by the analysis of >130 samples containing incurred residues where the results were compared with two existing LC-MS/MS methods.


Assuntos
Contaminação de Alimentos , Resíduos de Praguicidas , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Animais , Contaminação de Alimentos/análise , Resíduos de Praguicidas/análise , Praguicidas/análise , Ânions/análise , Análise de Alimentos/métodos , Cromatografia por Troca Iônica/métodos , Plantas/química
17.
Anal Bioanal Chem ; 416(15): 3595-3604, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38676823

RESUMO

Nucleotide sugars (NS) fulfil important roles in all living organisms and in humans, related defects result in severe clinical syndromes. NS can be seen as the "activated" sugars used for biosynthesis of a wide range of glycoconjugates and serve as substrates themselves for the synthesis of other nucleotide sugars. NS analysis is complicated by the presence of multiple stereoisomers without diagnostic transition ions, therefore requiring separation by liquid chromatography. In this paper, we explored weak anion-exchange/reversed-phase chromatography on a hybrid column for the separation of 17 nucleotide sugars that can occur in humans. A robust and reproducible method was established with intra- and inter-day coefficients of variation below 10% and a linear range spanning three orders of magnitude. Application to patient fibroblasts with genetic defects in mannose-1-phosphate guanylyltransferase beta, CDP-L-ribitol pyrophosphorylase A, and UDP-N-acetylglucosamine 2-epimerase/N-acetylmannosamine kinase showed abnormal levels of guanosine-5'-diphosphate-α-D-mannose (GDP-Man), cytidine-5'-diphosphate-L-ribitol (CDP-ribitol), and cytidine-5'-monophosphate-N-acetyl-ß-D-neuraminic acid (CMP-Neu5Ac), respectively, in consonance with expectations based on the diagnosis. In conclusion, a novel, semi-quantitative method was established for the analysis of nucleotide sugars that can be applied to diagnose several genetic glycosylation disorders in fibroblasts and beyond.


Assuntos
Cromatografia de Fase Reversa , Fibroblastos , Espectrometria de Massas em Tandem , Humanos , Fibroblastos/metabolismo , Espectrometria de Massas em Tandem/métodos , Cromatografia por Troca Iônica/métodos , Cromatografia de Fase Reversa/métodos , Nucleotídeos/análise , Nucleotídeos/metabolismo , Ânions/análise , Espectrometria de Massa com Cromatografia Líquida
18.
Anal Bioanal Chem ; 416(15): 3501-3508, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38658402

RESUMO

Alginate is a commercially important polysaccharide composed of mannuronic acid and its C5 differential isomer guluronic acid. Comprehensive research on alginate and alginate lyases requires efficient and precise analytical methods for alginate oligosaccharides. In this research, high-performance anion exchange chromatography (HPAEC) in parallel with pulsed amperometric detection (PAD) and mass spectrometry (MS) was applied to the analysis of oligosaccharides obtained by alginate lyase. By optimizing the chromatographic conditions including mobile phase concentration, flow rate, and elution gradient, the analysis of a single sample could be completed in 30 min. Seven unsaturated alginate oligosaccharides were separated and identified through their analysis time observed with PAD, including all structurally different unsaturated disaccharides and trisaccharides. The quantitative analysis of seven oligosaccharides was performed based on the quantitative capability of PAD. The method exhibited adequate linearity and precision parameters. All the calibration curves showed good linearity at least in the concentration range of 0.002 to 0.1 mg/mL. The HPAEC-PAD/MS method provides a general and efficient online method to analyze alginate oligosaccharides.


Assuntos
Alginatos , Espectrometria de Massas , Oligossacarídeos , Alginatos/química , Oligossacarídeos/análise , Oligossacarídeos/química , Cromatografia por Troca Iônica/métodos , Espectrometria de Massas/métodos , Cromatografia Líquida de Alta Pressão/métodos , Polissacarídeo-Liases/química , Polissacarídeo-Liases/metabolismo , Ácidos Hexurônicos/química , Ácidos Hexurônicos/análise , Limite de Detecção
19.
J Sep Sci ; 47(11): e2400126, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38819781

RESUMO

Chromatography is a technique of separation based on adsorption and/or interaction of target molecules with stationary phases. Herein, we report the design and fabrication of BTDA@SiO2 core-shell microspheres as a new class of stationary phase and demonstrate its impressive performance for chromatographic separations. The silica microspheres of BTDA@SiO2 were synthesized by in situ method with 1,3,5-benzenetricarboxaldehyde and 3,5-diaminobenzoic to separate peptides and proteins on high-performance liquid chromatography. The BTDA@SiO2 core-shell structure has a high specific surface area and retention factor of 4.27 and 8.31 for anionic and cationic peptides, respectively. The separation factor and resolution were high as well. A typical chromatogram illustrated nearly baseline resolution of the two peptides in less than 3 min. The BTDA@SiO2 was also highly stable in the pH range of 1 to 14. Furthermore, the prepared BTDA@SiO2 core-shell material not only be used for chromatographic separation but also as heavy metal removal from water. Using a BTDA@SiO2, we also achieved a lysozyme enrichment with a maximum saturated adsorption capacity reaching 714 mg/g. In summary, BTDA@SiO2 has great application prospects and significance in separation and purification systems.


Assuntos
Metais Pesados , Microesferas , Muramidase , Dióxido de Silício , Dióxido de Silício/química , Muramidase/química , Muramidase/isolamento & purificação , Cromatografia por Troca Iônica/métodos , Metais Pesados/química , Metais Pesados/isolamento & purificação , Adsorção , Cromatografia Líquida de Alta Pressão , Tamanho da Partícula , Propriedades de Superfície , Poluentes Químicos da Água/química , Poluentes Químicos da Água/isolamento & purificação
20.
Biosci Biotechnol Biochem ; 88(5): 509-516, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38425056

RESUMO

Nutrient availability in hydroponic solutions must be accurately monitored to maintain crop productivity; however, few cost-effective, accurate, real-time, and long-term monitoring technologies have been developed. In this study, we describe the development and application of cation-/anion-exchange chromatography with a neutral eluent (20-mmol/L sodium formate, pH 7.87) for the simultaneous separation (within 50 min) of ionic nutrients, including K+, NH4+, NO2-, NO3-, and phosphate ion, in a hydroponic fertilizer solution. Using the neutral eluent avoided degradation of the separation column during precipitation of metal ion species, such as hydroxides, with an alkaline eluent and oxidation of NO2- to NO3- with an acidic eluent. The suitability of the current method for monitoring ionic components in a hydroponic fertilizer solution was confirmed. Based on our data, we propose a controlled fertilizer strategy to optimize fertilizer consumption and reduce the chemical load of drained fertilizer solutions.


Assuntos
Fertilizantes , Hidroponia , Soluções , Hidroponia/métodos , Cromatografia por Troca Iônica/métodos , Fertilizantes/análise , Nutrientes/análise , Cátions/análise , Fosfatos/análise , Concentração de Íons de Hidrogênio , Potássio/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA