Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 166: 109389, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32882652

RESUMO

Copper oxide nanoparticles (CuO NPs) are needed in various fields, especially in the biomedical field. CuO NPs was obtained from Aspergillus terreus filtrate. CuO NPs structure was confirmed by UV-Vis spectrophotometry, as well as Fourier transform infrared (FT-IR), X-ray diffraction (XRD), scanning electron microscopy (SEM) and transmission electron microscopy (TEM). XRD offers the nanoparticles purity of CuO biosynthesis. CuO NPs are spherical when examined with TEM. The average size of CuO NPs from TEM was 15.75 ± 3.95 nm. New composite of P (AA-AN)-NPs CuO was synthesized by biotechnology and the induced γ-radiation. The distribution coefficient value (Kd) of 47Sc(III) as well as 47Ca(II) ions for the synthetic new composite was determined by batch technique. Radiochemical separation of 47Sc(III) from irradiated calcium target was studied using chromatographic column packed with the new composite material. The recovery yield of 78 ± 1.2% for 47Sc(III) was obtained using 1 M HCl. The quality control tests (chemical, radionuclide and radiochemical purities) of the eluted 47Sc confirmed that it's adequate for nuclear medicine applications.


Assuntos
Cobre/metabolismo , Nanopartículas Metálicas/química , Radioisótopos/isolamento & purificação , Escândio/isolamento & purificação , Aspergillus/metabolismo , Cobre/efeitos da radiação , Humanos , Nanopartículas Metálicas/efeitos da radiação , Nanopartículas Metálicas/ultraestrutura , Nanocompostos/química , Nanocompostos/efeitos da radiação , Nanocompostos/ultraestrutura , Medicina Nuclear , Tamanho da Partícula , Controle de Qualidade , Radioquímica , Radioisótopos/normas , Compostos Radiofarmacêuticos/isolamento & purificação , Compostos Radiofarmacêuticos/normas , Escândio/normas , Nanomedicina Teranóstica/métodos
2.
Radiat Prot Dosimetry ; 126(1-4): 155-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17513857

RESUMO

We are developing a national standard of a monoenergetic kilo electron volt neutron field with the (45)Sc(p,n)(45)Ti resonance reaction. A wide resonance yields 27.4 keV neutrons at 0 degrees with respect to the proton beam. The proton energy was precisely determined in the measurement of the relative neutron yield as a function of the proton energy from the threshold energy to 2.942 MeV. Absolute measurement of the monoenergetic neutron fluence was performed using a (3)He proportional counter. Relative measurement was also carried out using a Bonner sphere calibrated at our 144 keV standard neutron field. Calibration factors were obtained between the count of a neutron monitor and the neutron fluence. A silicon-surface barrier detector with a (6)LiF foil converter was also being developed for the neutron fluence measurement. Successful results were obtained in the tests in the 144 keV standard neutron field.


Assuntos
Nêutrons , Radiometria/normas , Escândio/química , Escândio/normas , Titânio/química , Titânio/normas , Japão , Doses de Radiação , Radiometria/métodos , Padrões de Referência , Espalhamento de Radiação
3.
Radiat Prot Dosimetry ; 126(1-4): 8-12, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17496303

RESUMO

The 8 and 27 keV monoenergetic neutron calibration fields have been developed by using (45)Sc(p, n)(45)Ti reaction. Protons from a 4-MV Pelletron accelerator are used to bombard a thin scandium target evaporated onto a platinum disc. The proton energies are finely adjusted to the resonance to generate the 8 and 27 keV neutrons by applying a high voltage to the target assemblies. The neutron energies were measured using the time-of-flight method with a lithium glass scintillation detector. The neutron fluences at a calibration point located at 50 cm from the target were evaluated using Bonner spheres. A long counter was placed at 2.2 m from the target and at 60 degrees to the direction of the proton beam in order to monitor the fluence at the calibration point. Fluence and dose equivalent rates at the calibration point are sufficient to calibrate many types of the neutron survey metres.


Assuntos
Nêutrons , Radioisótopos/análise , Radiometria/instrumentação , Radiometria/normas , Escândio/análise , Titânio/análise , Calibragem , Desenho de Equipamento , Análise de Falha de Equipamento , Japão , Radioisótopos/normas , Padrões de Referência , Escândio/normas , Titânio/normas
4.
Appl Radiat Isot ; 109: 314-318, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26701659

RESUMO

The half-life of the positron-emitter (44)Sc has been determined by following the decay rate with two measurement systems; an Ionisation Chamber and a HPGe detector. The combination of seven results gives a value of T1/2=4.042 (25)h, about 2% higher than the recommended value of T1/2=3.97 (4)h (Browne, 2011) and with a lower uncertainty. This radionuclide has also been standardised by coincidence counting, and liquid scintillation counting techniques. A (44)Ti/(44)Sc generator developed at CIEMAT was used to obtain the (44)Sc solutions used in all measurements.


Assuntos
Meia-Vida , Dosímetros de Radiação/normas , Radioisótopos/análise , Radioisótopos/normas , Escândio/análise , Escândio/normas , Calibragem/normas , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espanha
5.
Biol Trace Elem Res ; 130(3): 273-82, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19221697

RESUMO

Some of the rare earth elements such as Sc are believed to be non-toxic and, at present, are widely utilized for the replacement of toxic heavy metals in technological applications, but they are not entirely free of toxicity, with hidden potential health risks. In this animal experiment, we report the urinary scandium (Sc) excretion rate and nephrotoxiciy in male Wistar rats. For this purpose, the rats were given a single dose of a solution of scandium chloride by intraperitoneal injection. The Sc excretion (U-Sc) was determined in 24-h urine samples by inductively coupled plasma-argon emission spectrometry along with the Sc nephrotoxicity, urine volume (UV), creatinine (Crt), beta-2-microglobulin (beta2-MG) and N-acetyl-beta-D-glucosaminidase (NAG). A dose-dependent Sc excretion of 0.0063% (r = 0.97) via 24-h urine was confirmed. The administration of Sc induced a significant decrease of UV and Crt and a significant increase of NAG and beta2-MG. These results suggest that U-Sc can be a useful tool for monitoring Sc exposure. The formation of Sc colloidal conjugates that deposit in glomeruli may be the cause of a reduction of the glomerular filtration rate. We propose that the analytical method and results described in this study will be of great importance for future toxicological studies on Sc exposure.


Assuntos
Cloretos/toxicidade , Rim/efeitos dos fármacos , Escândio/urina , Acetilglucosaminidase/urina , alfa-Globulinas/urina , Animais , Cloretos/administração & dosagem , Creatinina/urina , Exposição Ambiental/análise , Injeções Intraperitoneais , Rim/patologia , Masculino , Ratos , Ratos Wistar , Escândio/administração & dosagem , Escândio/normas , Escândio/toxicidade , Espectrofotometria Atômica/métodos , Microglobulina beta-2/urina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA