Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 139
Filtrar
1.
Audiol Neurootol ; 25(1-2): 50-59, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31505507

RESUMO

INTRODUCTION: Cochlear implantation (CI) has been reported to negatively affect vestibular function. The study of vestibular function has variably been conducted using different types of diagnostic tools. The combined use of modern, rapidly performing diagnostic tools could prove useful for standardization of the evaluation protocol. METHODS: In a group of 28 subjects undergoing CI, the video head impulse test (vHIT), the cervical vestibular evoked myogenic potentials (cVEMP) and the short form of the Dizziness Handicap Inventory (DHI) questionnaire were investigated preoperatively and postoperatively (implant on and off) in both the implanted and the contralateral, nonimplanted ear. All surgeries were performed with a round window approach (RWA), except for 3 otosclerosis cases in which the extended RWA (eRWA) was used. RESULTS: The vHIT of the lateral semicircular canal showed preoperative vestibular involvement in nearly 50% of the cases, while the 3 canals were contemporarily affected in only 14% of the cases. In all the hypofunctional subjects, cVEMP were absent. A low VOR gain in all of the investigated superior semicircular canals was found in 4 subjects (14%). In those subjects (21.7%) in whom cVEMP were preoperatively present and normal on the operated side, the absence of a response was postoperatively recorded. DISCUSSION/CONCLUSION: The vestibular protocol applied in this study was found to be appropriate for distinguishing between the CI-operated ear and the nonoperated ear. In this regard, cVEMP was found to be more sensitive than vHIT for revealing a vestibular sufferance after CI, though without statistical significance. Finally, the use of RWA surgery apparently did not reduce the occurrence of signs of vestibular impairment.


Assuntos
Implante Coclear/efeitos adversos , Implantes Cocleares , Tontura/diagnóstico , Perda Auditiva/cirurgia , Vertigem/diagnóstico , Testes de Função Vestibular , Vestíbulo do Labirinto/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Tontura/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/fisiopatologia , Período Pós-Operatório , Janela da Cóclea/fisiopatologia , Canais Semicirculares/fisiopatologia , Inquéritos e Questionários , Vertigem/fisiopatologia , Potenciais Evocados Miogênicos Vestibulares/fisiologia , Adulto Jovem
2.
Int J Audiol ; 59(5): 341-347, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31860369

RESUMO

Objective: Subjects implanted with a Direct Acoustic Cochlear Implant (DACI) show improvements in their bone conduction (BC) thresholds after surgery. We hypothesised that a new pathway for BC sound is created via the DACI. The aim of this study was to investigate the contribution of this pathway to the cochlear response via measurements of the promontory and round window membrane (RWM) velocities while stimulating with a conventional bone conductor.Design: This study was a cadaver head study with a repeated measures study design.Study Sample: Eight ears of five fresh-frozen cadaveric whole heads were investigated in this trial.Results: After DACI implantation the promontory and RWM velocities did not change significantly in the frequency range 0.5-2 kHz when the DACI was switched off.Conclusions: No significant changes in the relative vibration magnitude of the RWM after DACI implantation were observed. The improvements in BC thresholds seen in patients implanted with a DACI very likely have their origin in the changed impedance at the oval window after DACI surgery leading to a more efficient contribution from the inner ear components to BC sound.


Assuntos
Condução Óssea/fisiologia , Implantes Cocleares , Janela da Cóclea/fisiopatologia , Estimulação Acústica , Idoso , Idoso de 80 Anos ou mais , Limiar Auditivo/fisiologia , Cadáver , Implante Coclear , Orelha Interna/fisiopatologia , Feminino , Humanos , Masculino , Período Pós-Operatório , Janela da Cóclea/cirurgia , Vibração
3.
J Acoust Soc Am ; 146(6): 4122, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31893738

RESUMO

An active actuator coupled to the round window (RW) can transmit mechanical vibrations into the cochlea and has become a therapeutic option of hearing rehabilitation for patients with stapedial otosclerosis. A finite-element model of the human ear that includes sound transmission effects of the vestibular and cochlear aqueducts of the inner ear is adopted in this study for investigating the cochlear response to RW stimulation under stapes fixation. There are two effects due to otosclerosis of the stapes: the fixation of the stapedial annular ligament (SAL) and the increase of the stapes mass. The frequency responses of the middle ear and cochlea with normal and otosclerotic stapes are calculated under sound and RW stimulations. The results show that changes in the material property of the stapes have different effects on the cochlear responses under sound and RW stimulations. Because of the vestibuli aqueduct, the reduction in the low-frequency magnitude of the pressure difference across the cochlear partition due to SAL fixation is much smaller under RW stimulation than under sound stimulation. The results of this study help understand sound transmission during RW stimulation in patients with stapedial otosclerosis.


Assuntos
Análise de Elementos Finitos , Otosclerose/fisiopatologia , Janela da Cóclea/fisiopatologia , Estribo/fisiologia , Estimulação Acústica/métodos , Cóclea/fisiologia , Orelha Média/fisiologia , Audição/fisiologia , Humanos , Prótese Ossicular , Som
4.
Ear Hear ; 38(4): e241-e255, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28207578

RESUMO

OBJECTIVES: As a treatment for partial deafness with residual hearing in the lower frequency range, the combined acoustic and electric stimulation of the cochlea has become widespread. Acoustic stimulation is provided by a hearing aid's airborne sound and the electric stimulation by a cochlear implant electrode array, which may be inserted through the round window or a cochleostomy. To take advantage of that concept, it is essential to preserve residual hearing after surgery. Therefore, the intracochlear electrode array should not compromise the middle ear vibration transmission. This study investigates the influence of different electrode types and insertion paths on the middle ear transfer function and the inner ear fluid dynamics. DESIGN: Sound-induced oval and round window net volume velocities were calculated from vibration measurements with laser vibrometers on six nonfixated human temporal bones. After baseline measurements in the "natural" condition, a cochleostomy was drilled and closed with connective tissue. Then, four different electrode arrays were inserted through the cochleostomy. Afterwards, they were inserted through the round window while the cochleostomy was patched again with connective tissue. RESULTS: After having drilled a cochleostomy and electrode insertion, no systematic trends in the changes of oval and round window volume velocities were observed. Nearly all changes of middle ear transfer functions, as well as oval and round window volume velocity ratios, were statistically insignificant. CONCLUSIONS: Intracochlear electrode arrays do not significantly increase cochlear input impedance immediately after insertion. Any changes that may occur seem to be independent of electrode array type and insertion path.


Assuntos
Cóclea/cirurgia , Implante Coclear/métodos , Perda Auditiva/reabilitação , Janela do Vestíbulo/fisiopatologia , Janela da Cóclea/fisiopatologia , Estimulação Acústica , Implantes Cocleares , Orelha Média/fisiopatologia , Estimulação Elétrica , Auxiliares de Audição , Humanos , Período Pós-Operatório
5.
Ear Hear ; 36(2): 249-60, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25259669

RESUMO

OBJECTIVES: The goal was to measure the magnitude of cochlear responses to sound in pediatric cochlear implant recipients at the time of implantation and to correlate this magnitude with subsequent speech perception outcomes. DESIGN: A longitudinal cohort study of pediatric cochlear implant recipients was undertaken. Intraoperative electrocochleographic (ECoG) recordings were obtained from the round window in response to a frequency series at 90 dB nHL in 77 children totaling 89 ears (12 were second side surgeries) just before device insertion. The increase in intraoperative time was approximately 10 min. An ECoG "total response" metric was derived from the summed magnitudes of significant responses to the first, second, and third harmonics across a series of frequencies. A subset of these children reached at least 9 months of implant use and were old enough for the phonetically balanced kindergarten (PB-k) word test to be administered (n = 26 subjects and 28 ears). PB-k scores were compared to the ECoG total response and other biologic and audiologic variables using univariate and multiple linear regression analyses. RESULTS: ECoG responses were measurable in almost all ears (87 of 89). The range of ECoG total response covered about 60 dB (from ~0.05 to 50 µV). Analyzing individual ECoG recordings in bilaterally implanted children revealed poor concordance between the measured response in the first versus second ear implanted (r = 0.21; p = 0.13; n = 12). In a univariate linear regression, the ECoG total response was significantly correlated with PB-k scores in the subset of 26 subjects who were able to be tested and accounted for 32% of the variance (p = 0.002, n = 28). Preoperative pure-tone average (PTA) accounted for slightly more of the variance (r = 0.37, p = 0.001). However, ECoG total response and PTA were significantly but only weakly correlated (r = 0.14, p = 0.001). Other significant predictors of speech performance included hearing stability (stable versus progressive) and age at testing (22 and 16% of the variance, respectively). In multivariate analyses with these four factors, the ECoG accounted for the most weight (ß = 0.36), followed by PTA (ß = 0.26). In a hierarchical multiple regression analysis, the most parsimonious models that best predicted speech perception outcomes included three variables: ECoG total response, and any two of preoperative PTA, age at testing, or hearing stability. The various three factor models each predicted approximately 50% of the variance in word scores. Without the ECoG total response, the other three factors predicted 36% of variance. CONCLUSIONS: Intraoperative round window ECoG recordings are reliably and easily obtained in pediatric cochlear implant recipients. The ECoG total response is significantly correlated with speech perception outcomes in pediatric implant recipients and can account for a comparable or greater proportion of variance in speech perception than other bio-audiologic factors. Intraoperative recordings can potentially provide useful prognostic information about acquisition of open set speech perception in implanted children.


Assuntos
Perda Auditiva/reabilitação , Janela da Cóclea/fisiopatologia , Percepção da Fala , Adolescente , Audiometria de Resposta Evocada , Criança , Pré-Escolar , Implante Coclear/métodos , Estudos de Coortes , Feminino , Perda Auditiva/fisiopatologia , Humanos , Lactente , Cuidados Intraoperatórios , Modelos Lineares , Estudos Longitudinais , Masculino , Análise Multivariada , Prognóstico , Estudos Prospectivos , Resultado do Tratamento
6.
Eur Arch Otorhinolaryngol ; 272(4): 853-860, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24452773

RESUMO

Clinical conditions have been described in which one of the two cochlear windows is immobile (otosclerosis) or absent (round window atresia), but nevertheless bone conduction (BC) thresholds are relatively unaffected. To clarify this apparent paradox, experimental manipulations which would severely impede several of the classical osseous mechanisms of BC were induced in fat sand rats, including discontinuity or immobilization of the ossicular chain, coupled with window fixation. Effects of these manipulations were assessed by recording auditory nerve brainstem evoked response (ABR) thresholds to stimulation by air conduction (AC), by osseous BC and by non-osseous BC (also called soft tissue conduction-STC) in which the BC bone vibrator is applied to skin sites. Following the immobilization, discontinuity and window fixation, auditory stimulation was also delivered to cerebro-spinal fluid (CSF) and to saline applied to the middle ear cavity. While the manipulations (immobilization, discontinuity, window fixation) led to an elevation of AC thresholds, nevertheless, there was no change in osseous and non-osseous BC thresholds. On the other hand, ABR could be elicited in response to fluid pressure stimulation to CSF and middle ear saline, even in the presence of the severe restriction of ossicular chain and window mobility. The results of these experiments in which osseous and non-osseous BC thresholds remained unchanged in the presence of severe restriction of the classical middle ear mechanisms and in the absence of an efficient release window, while ABR could be recorded in response to fluid pressure auditory stimulation to fluid sites, indicate that it is possible that the inner ear may be activated at low sound intensities by fast fluid pressure stimulation. At higher sound intensities, a slower passive basilar membrane traveling wave may serve to excite the inner ear.


Assuntos
Membrana Basilar , Condução Óssea/fisiologia , Doenças Cocleares/congênito , Ossículos da Orelha , Otosclerose , Janela da Cóclea , Estimulação Acústica/métodos , Animais , Membrana Basilar/patologia , Membrana Basilar/fisiopatologia , Modelos Animais de Doenças , Ossículos da Orelha/patologia , Ossículos da Orelha/fisiopatologia , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Gerbillinae , Ratos , Janela da Cóclea/patologia , Janela da Cóclea/fisiopatologia
7.
Int J Audiol ; 54(6): 391-400, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25735204

RESUMO

OBJECTIVE: To compare audiological outcomes in mild-to-moderate mixed hearing loss patients treated with a bone-anchored hearing aid or an active middle-ear implant. Analysis aimed to refine criteria used in preoperative selection of implant type. DESIGN: Retrospective comparative analysis of audiological data. Follow-up time ranged between 0.55 and 8.8 years. STUDY SAMPLE: For detailed comparative analysis, 12 patients (six in each group) with comparable bone conduction thresholds and similar clinical characteristics were selected. A larger cohort of 48 patient files were used to evaluate overall audiological indication criteria (24 per group). RESULTS: In free-field tone audiometry, Baha patients showed mean aided thresholds between 40-48 dB, whereas hearing thresholds for VSB patients were 25-43 dB. Baha and VSB users had mean WRS of 56% and 82%, respectively, at 65 dB. Better speech understanding in noise was seen with the VSB. CONCLUSION: Analysis of the main cohort (n = 48) showed that treatment with round window vibroplasty leads to better hearing performance than treatment with a bone-anchored hearing device, if the bone conduction pure-tone average (0.5 to 4 kHz) is poorer than 35 dB HL. Audiological analysis in the smaller comparative analysis showed similar findings.


Assuntos
Estimulação Acústica/métodos , Correção de Deficiência Auditiva/métodos , Auxiliares de Audição , Perda Auditiva Condutiva-Neurossensorial Mista/reabilitação , Prótese Ossicular , Estimulação Acústica/instrumentação , Adulto , Idoso , Audiometria , Limiar Auditivo , Condução Óssea/fisiologia , Correção de Deficiência Auditiva/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ruído , Estudos Retrospectivos , Janela da Cóclea/fisiopatologia , Percepção da Fala , Adulto Jovem
8.
Int J Audiol ; 52(4): 209-18, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23527900

RESUMO

OBJECTIVE: This study was undertaken to determine the efficacy of the round window (RW) application of the vibrant soundbridge (VSB) in patients with mixed or conductive hearing loss. DESIGN: Speech in quiet and in noise were compared to preoperative data attained with conventional hearing aids so that each subject served as his or her own control in a single test protocol. STUDY SAMPLE: Eighteen adults implanted monaurally with the VSB in the poorer hearing ear. Experience with the VSB ranged from nine to 25 months. RESULTS: Sixteen of the 18 subjects were successful VSB users, wearing their device all waking hours. There was no significant deterioration in the averaged bone conduction results preoperatively versus post-operatively (p>0.05). Speech recognition in quiet results were not significantly different to performance attained whilst wearing hearing aids (p>0.05). Speech recognition in noise performance was substantially improved with use of the VSB in most test conditions. CONCLUSIONS: For the majority of the subjects, the VSB was an effective method of hearing restoration for their mixed and conductive hearing loss.


Assuntos
Correção de Deficiência Auditiva/instrumentação , Auxiliares de Audição , Perda Auditiva Condutiva/reabilitação , Perda Auditiva Condutiva-Neurossensorial Mista/reabilitação , Pessoas com Deficiência Auditiva/reabilitação , Implantação de Prótese/instrumentação , Janela da Cóclea/fisiopatologia , Adulto , Idoso , Audiometria de Tons Puros , Audiometria da Fala , Condução Óssea , Desenho de Equipamento , Feminino , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva/fisiopatologia , Perda Auditiva Condutiva/psicologia , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Perda Auditiva Condutiva-Neurossensorial Mista/fisiopatologia , Perda Auditiva Condutiva-Neurossensorial Mista/psicologia , Humanos , Masculino , Pessoa de Meia-Idade , Ruído/efeitos adversos , Mascaramento Perceptivo , Pessoas com Deficiência Auditiva/psicologia , Desenho de Prótese , Reconhecimento Psicológico , Inteligibilidade da Fala , Percepção da Fala , Terapêutica , Fatores de Tempo , Vibração , Adulto Jovem
9.
Laryngorhinootologie ; 92(6): 394-9, 2013 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-23670562

RESUMO

Drilling a promontory window and coupling an FMT into the scala tympani may be a surgical alternative to stapes surgery in obliterative tympanosclerosis. Aim of this experimental study on human temporal bones was to measure changes of the acoustic transfer function from the tympanic membrane to the round window membrane after drilling a promontory window and insertion of a floating mass transducer.Laser vibrometry and acoustic measurements were performed on 11 temporal bone preparations equipped with a microphone attached to the round window. Calibrations were carried out to allow determination of SPLs affecting the cochlea after drilling a promontory window leaving the membranous inner ear intact and after insertion of an FMT into the cavity (with or without slight pressure).Drilling a promontory window does influence the transfer function. Insertion of the FMT with additional slight pressure further changes the transfer function.The presence of a promontory window changes the acoustic transfer function to the round window. Further investigations are needed to correlate the qualitative results with the audiological results after "third window vibroplasty" (inserted floating mass transducer without stimulation).


Assuntos
Fenestração do Labirinto , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Miringoesclerose/diagnóstico por imagem , Complicações Pós-Operatórias/fisiopatologia , Janela da Cóclea/fisiopatologia , Vibração , Estimulação Acústica , Perda Auditiva Condutiva-Neurossensorial Mista/fisiopatologia , Humanos , Modelos Anatômicos , Radiografia , Som , Espectrografia do Som , Estribo/fisiopatologia , Membrana Timpânica/fisiologia
10.
Ear Hear ; 33(5): e24-31, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22699658

RESUMO

OBJECTIVES: As prostheses and techniques related to stapes surgery develop and improve, there is a need to assess the functional outcomes of the surgery objectively. This study provides a bench test method to assess the functional results of stapes surgery by measuring volume displacement at the round window (RW), which is closely related to pressure propagation of the travelling wave inside the cochlea and thus to hearing. DESIGN: Motion of the RW membrane in fresh temporal bones was measured using a scanning laser Doppler interferometry system for normal and reconstructed conditions, and the performance of the reconstruction with stapes surgery was quantitatively assessed by comparison of the volume displacements at the RW between the two conditions. To obtain optimal measurements, reflectivity of the laser beam of the scanning laser Doppler interferometry system was improved by retroreflective beads coated onto the surface of the RW, and orientation of the RW membrane relative to the laser beam was obtained using micro-computed tomography imaging. RESULTS: From measurements in 12 temporal bones, difference in the RW volume displacement between normal ears and ears reconstructed with stapes surgery was approximately 15 dB below 2 kHz and approximately 10 dB above 4 kHz, which was comparable with air-bone gaps in patients after stapes surgery. Two different sizes of the stapes prostheses were also tested (n = 3), and a tendency toward a better outcome with a larger diameter was found. CONCLUSION: The method developed in this study can be used to assess various prostheses and surgical conditions objectively in controlled laboratory environments. It may also have potential for providing ways to assess other middle- and inner-ear surgeries, and to study other aspects of hearing science.


Assuntos
Interferometria/métodos , Prótese Ossicular , Janela do Vestíbulo/fisiologia , Janela da Cóclea/fisiologia , Cirurgia do Estribo/métodos , Osso Temporal/fisiologia , Estudos de Casos e Controles , Feminino , Audição/fisiologia , Testes Auditivos , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Janela do Vestíbulo/fisiopatologia , Janela da Cóclea/fisiopatologia , Som , Osso Temporal/fisiopatologia
11.
Sci Rep ; 11(1): 16775, 2021 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-34408166

RESUMO

Acoustic hearing aids generate amplified sound in the ear canal, and they are the standard of care for patients with mild to moderate sensorineural hearing loss. However, because of their limited frequency bandwidth, gain, and feedback, there is substantial room for improvement. Active middle ear implants, which directly vibrate the middle ear and cochlea, are an alternative approach to conventional acoustic hearing aids. They provide an opportunity to improve sound quality and speech understanding with amplification rehabilitation. For floating-mass type and direct-rod type (DRT) middle ear transducers, a differential floating-mass transducer (DFMT) and a tri-coil bellows transducer (TCBT), respectively, were fabricated to measure the output characteristics in four human temporal bones. Both were fabricated to have similar output forces per unit input and were placed in four human temporal bones to measure their output performances. The TCBT resulted in higher output than did the DFMT throughout the audible frequency range, and the output was more prominent at lower frequency ranges. In this study, we showed that DRT was a more effective method for round window stimulation. Because of its frequency characteristics and vibration efficiency, this implantation method can be utilized as a driving solution for middle ear implants.


Assuntos
Estimulação Acústica , Auxiliares de Audição , Perda Auditiva/fisiopatologia , Janela da Cóclea/fisiopatologia , Osso Temporal/fisiopatologia , Humanos
12.
Acta Otolaryngol ; 141(6): 588-593, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33823755

RESUMO

BACKGROUND: Long-term use of a unilateral cochlear implant (CI) may lead to abnormal development of contralateral auditory pathway. OBJECTIVES: To investigate the usefulness of measuring the electrically evoked auditory brainstem response (eABR) with the electrical stimulation at the round window membrane and the effect of unilateral CI use on the contralateral auditory pathway functions. MATERIALS AND METHODS: According to duration of unilateral CI use, 45 children with severe or profound sensorineural hearing loss were divided into sCI (≤12 months), lCI (≥24 months) and nCI (no CI use) groups. Intra-operative eABRs evoked by electrical stimulation at the round window membrane were recorded. RESULTS: The latencies of eIII and eV were significantly longer in lCI group than in sCI group and in nCI group, respectively, but not significantly different between sCI group and nCI group. The eABR thresholds and eIII-eV latency intervals were not significantly different among three groups. CONCLUSIONS AND SIGNIFICANCE: The eABR evoked by the electrical stimulation at the round window membrane is a reliable and effective way of evaluating functions of the auditory pathway in deaf children. Long-term use of a unilateral CI may promote the degenerative process of the contralateral auditory pathway to the level of the brainstem.


Assuntos
Vias Auditivas/fisiopatologia , Implantes Cocleares , Potenciais Evocados Auditivos do Tronco Encefálico , Perda Auditiva Neurossensorial/fisiopatologia , Janela da Cóclea/fisiopatologia , Adolescente , Limiar Auditivo/fisiologia , Criança , Pré-Escolar , Estimulação Elétrica , Feminino , Humanos , Lactente , Masculino
13.
Acta Otolaryngol ; 141(6): 557-566, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33881381

RESUMO

Background: In operations of cochlea implantation (CI), many surgeons choose to drill a window on the bone wall of cochlea basic rotation, when more and more patients receive CI with residual hearing, what damage this step would result in is unclear.Objective: To study the effect to inner ear hair cells which is caused by drilling during CI.Methods: 6 miniature pigs are equally divided into two groups, Round window niche of each pig in the experimental group was milled, while the pigs in control group wasn't. After implanting depth of 6.5, 11.5 and 20 mm, round window electrocochleography was recorded to analyze the change of cochlea microphonic (CM) potentials respectively, histomorphological changes was observed.Results: Thresholds of CM in experimental group were higher than that of control group at different depth, amplitudes were smaller. In further group, cilia of inner hair cells (IHC) at bottom rotation were significantly damaged. After operation, ABR hearing threshold of experimental group was higher, differences at low frequency region were more obvious.Conclusions: Damage caused by mulling round window niche may seriously affect the function of the hair cells. Damage of the IHC is greater than OHC. CI through round window may protect residual hearing.


Assuntos
Potenciais Microfônicos da Cóclea , Células Ciliadas Auditivas/fisiologia , Janela da Cóclea/fisiopatologia , Animais , Orelha Interna , Potenciais Evocados Auditivos do Tronco Encefálico , Células Ciliadas Auditivas/patologia , Modelos Animais , Janela da Cóclea/lesões , Janela da Cóclea/patologia , Suínos , Porco Miniatura
14.
Eur Arch Otorhinolaryngol ; 267(5): 691-9, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-19847455

RESUMO

Gacyclidine, a non-competitive NMDA receptor antagonist, is a phencyclidine derivative with neuroprotective properties. It has been previously safely administered intravenously to acute traumatic brain-injured patients. Experiments in guinea pigs have shown that local administration of gacyclidine to the cochlea can suppress salicylate-induced tinnitus. Thus, we thought that patients with therapy-resistant sensorineural tinnitus might benefit from a local therapy with gacyclidine. As a compassionate treatment, we administered aqueous gacyclidine solution via a Durect RWmuCath(TM) into the round window niche in six patients with unilateral deafness associated with tinnitus. The response of each patient to the drug treatment was given a numerical value by the use of a visual analogue scale (VAS) on a scale of 0-10 for tinnitus intensity, where 0 represented no tinnitus and 10 represented unbearable tinnitus-intensity or -annoyance (subjective). After constant perfusion of gacyclidine for 40-63 h, four out of six patients experienced a temporary relief from their tinnitus. No serious side effects were recorded in any of the cases. Gacyclidine might present a potent drug for the suppression of sensorineural tinnitus in humans and therefore should be considered for future double-blinded, placebo-controlled clinical trials. For lasting effective treatment, controlled intracochlear and long-term delivery of the drug seems to be necessary. Further studies investigating the toxicological effects of gacyclidine intracochlear perfusion as well as different dosages and therapy durations are under way to ensure the safety of the drug for long-term human use and warrant clinical trials.


Assuntos
Cóclea/efeitos dos fármacos , Cicloexenos/farmacologia , Cicloexenos/uso terapêutico , Fármacos Neuroprotetores/farmacologia , Fármacos Neuroprotetores/uso terapêutico , Piperidinas/farmacologia , Piperidinas/uso terapêutico , Zumbido/tratamento farmacológico , Administração Tópica , Adolescente , Adulto , Audiometria de Tons Puros/métodos , Feminino , Perda Auditiva Neurossensorial/complicações , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Receptores de N-Metil-D-Aspartato/antagonistas & inibidores , Janela da Cóclea/efeitos dos fármacos , Janela da Cóclea/fisiopatologia , Zumbido/complicações , Zumbido/fisiopatologia , Adulto Jovem
15.
Audiol Neurootol ; 14(3): 172-80, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19005251

RESUMO

OBJECTIVES: The safety and performance of the Otologics fully implantable hearing device were assessed in adult patients with mixed conductive and sensorineural hearing loss. METHODS: The subcutaneous microphone of this fully implantable device picks up ambient sounds, converts them into an electrical signal, amplifies the signal according to the user's needs, and sends it to an electromechanical transducer. The transducer tip is customized with a prosthesis in order to be in contact with the round window membrane and is protected by fascia; this translates the electrical signal into a mechanical motion that directly stimulates the round window membrane and enables the user to perceive sound. The implanted battery is recharged daily via an external charger and the user can turn the implant on and off as well as adjust the volume with a hand-held remote control. In this pilot study, 6 patients with mixed conductive and sensorineural hearing loss were implanted with the Otologics fully implantable hearing device. Pre- and postoperative air conduction, bone conduction, as well as aided and unaided thresholds and speech scores were measured. RESULTS: No significant differences between preoperative and postoperative pure-tone averages were noted. Average improvement ranged from 19.16 to 35.8 dB of functional gain across audiometric frequencies with a mean of 26.17 +/- 5.15 dB. Long-term average functional gain at 12 months was 20.83 +/- 6.22 dB. Word recognition scores demonstrated significant differences between unaided and implant-aided conditions. CONCLUSIONS: Preliminary results of this trial of the Otologics fully implantable hearing device provide evidence that this fully implantable device is capable of efficiently transferring the sound to the inner ear via the round window membrane in patients with mixed hearing loss.


Assuntos
Perda Auditiva Condutiva/cirurgia , Perda Auditiva Neurossensorial/cirurgia , Implantação de Prótese/métodos , Janela da Cóclea/cirurgia , Percepção da Fala , Estimulação Acústica , Audiometria de Tons Puros , Limiar Auditivo , Potenciais Evocados Auditivos , Seguimentos , Perda Auditiva Condutiva/fisiopatologia , Perda Auditiva Neurossensorial/fisiopatologia , Humanos , Monitorização Intraoperatória , Projetos Piloto , Janela da Cóclea/fisiopatologia , Segurança
16.
J Acoust Soc Am ; 125(4): 2129-45, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19354389

RESUMO

Distortion products in the cochlear microphonic (CM) and in the ear canal in the form of distortion product otoacoustic emissions (DPOAEs) are generated by nonlinear transduction in the cochlea and are related to the resting position of the organ of Corti (OC). A 4.8 Hz acoustic bias tone was used to displace the OC, while the relative amplitude and phase of distortion products evoked by a single tone [most often 500 Hz, 90 dB SPL (sound pressure level)] or two simultaneously presented tones (most often 4 kHz and 4.8 kHz, 80 dB SPL) were monitored. Electrical responses recorded from the round window, scala tympani and scala media of the basal turn, and acoustic emissions in the ear canal were simultaneously measured and compared during the bias. Bias-induced changes in the distortion products were similar to those predicted from computer models of a saturating transducer with a first-order Boltzmann distribution. Our results suggest that biased DPOAEs can be used to non-invasively estimate the OC displacement, producing a measurement equivalent to the transducer operating point obtained via Boltzmann analysis of the basal turn CM. Low-frequency biased DPOAEs might provide a diagnostic tool to objectively diagnose abnormal displacements of the OC, as might occur with endolymphatic hydrops.


Assuntos
Cóclea/fisiologia , Órgão Espiral/fisiologia , Estimulação Acústica , Animais , Cóclea/fisiopatologia , Ducto Coclear/fisiologia , Ducto Coclear/fisiopatologia , Potenciais Microfônicos da Cóclea , Meato Acústico Externo/fisiologia , Meato Acústico Externo/fisiopatologia , Potenciais Evocados Auditivos , Feminino , Cobaias , Hipóxia/fisiopatologia , Masculino , Microeletrodos , Órgão Espiral/fisiopatologia , Emissões Otoacústicas Espontâneas , Janela da Cóclea/fisiologia , Janela da Cóclea/fisiopatologia , Membrana Timpânica/fisiologia , Membrana Timpânica/fisiopatologia
17.
Nat Neurosci ; 8(8): 1035-42, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15995703

RESUMO

Alpha-tectorin (encoded by Tecta) is a component of the tectorial membrane, an extracellular matrix of the cochlea. In humans, the Y1870C missense mutation in TECTA causes a 50- to 80-dB hearing loss. In transgenic mice with the Y1870C mutation in Tecta, the tectorial membrane's matrix structure is disrupted, and its adhesion zone is reduced in thickness. These abnormalities do not seriously influence the tectorial membrane's known role in ensuring that cochlear feedback is optimal, because the sensitivity and frequency tuning of the mechanical responses of the cochlea are little changed. However, neural thresholds are elevated, neural tuning is broadened, and a sharp decrease in sensitivity is seen at the tip of the neural tuning curve. Thus, using Tecta(Y1870C/+) mice, we have genetically isolated a second major role for the tectorial membrane in hearing: it enables the motion of the basilar membrane to optimally drive the inner hair cells at their best frequency.


Assuntos
Surdez/fisiopatologia , Proteínas da Matriz Extracelular/genética , Audição/fisiologia , Glicoproteínas de Membrana/genética , Mutação de Sentido Incorreto , Membrana Tectorial/fisiologia , Estimulação Acústica , Potenciais de Ação , Animais , Cóclea/fisiopatologia , Potenciais Microfônicos da Cóclea , Surdez/genética , Limiar Diferencial , Proteínas Ligadas por GPI , Células Ciliadas Auditivas/patologia , Células Ciliadas Auditivas Externas , Mecanotransdução Celular , Camundongos , Camundongos Transgênicos , Emissões Otoacústicas Espontâneas , Janela da Cóclea/fisiopatologia , Membrana Tectorial/patologia
18.
Acta Otolaryngol ; 139(4): 351-356, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30987498

RESUMO

BACKGROUND: Thiel conservation is mainly based on a watery solution of salts. We have shown that bone conduction (BC) evokes motion in normal middle ears of Thiel embalmed specimens that is comparable to the motion for other cadaveric models. AIMS/OBJECTIVES: We evaluated whether promontory and round window (RW) motion identifies differences in BC transmission for different middle ear conditions. METHODS: We investigated the conditions of mobile ossicle chain, cement-fixed stapes and stapedectomy in seven ears. A retroauricular bone anchored hearing system provided BC stimulation. The motions of the promontory and the RW were measured using single point laser Doppler vibrometer (LDV, HLV1000, Polytec). RESULTS: The averaged differences between the conditions were small for RW motion and for promontory motion. However, for RW motion we found differences of more than one standard deviation at some frequencies. These differences in RW motion were more apparent when we limited the analysis to three selected specimens. CONCLUSIONS AND SIGNIFICANCE: Extracochlear measurement of the RW motion with LDV allowed differentiation between BC for different middle ear conditions. These changes could be detected best in a small frequency range in selected specimens. Promontory motion could not be used to differentiate between different conditions of the middle ear. ABBREVIATIONS: LDV: laser Doppler vibrometry; Prom: cochlear promontory; RW: round window; ST: stapes; TM: tympanic membrane; VProm: velocity of the promontory; VRW: velocity of the round window.


Assuntos
Condução Óssea , Otopatias/fisiopatologia , Janela da Cóclea/fisiopatologia , Estribo/fisiopatologia , Embalsamamento , Humanos , Cirurgia do Estribo
19.
IEEE Trans Biomed Eng ; 66(6): 1609-1617, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30334746

RESUMO

Residual hearing loss in cochlear implant users is investigated using the mechanical-human-cochlear model. Hearing loss due to stiffening of the round window increases significantly as input frequencies decrease from 3 kHz to 1 kHz but remains constant at lower frequencies, whereas loss due to the presence of an electrode insert becomes significantly higher at lower frequencies ([Formula: see text] kHz). The latter also shifts the characteristic frequency map toward the basal end of the cochlea. In the region away from the end of the electrode insert, cochlear function recovers, but the user still suffers from hearing loss caused by round window stiffening.


Assuntos
Implantes Cocleares/efeitos adversos , Transtornos da Audição/fisiopatologia , Janela da Cóclea/fisiopatologia , Percepção da Fala/fisiologia , Estimulação Acústica/instrumentação , Membrana Basilar/fisiopatologia , Audição/fisiologia , Transtornos da Audição/cirurgia , Humanos , Modelos Biológicos , Processamento de Sinais Assistido por Computador
20.
Int Tinnitus J ; 14(2): 101-7, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19205159

RESUMO

In an animal model, we examined the extratympanic electrocochleographic response to static pressure changes (middle-ear pressure and intracranial pressure [ICP]) with attention to the summating potential (SP), action potential (AP), and the SP/AP ratio. With a closed middle ear, raised or lowered middle-ear pressure and raised or lowered ICP resulted in congruent increases of the SP and the SP/AP ratio, while the AP remained at a steady voltage. With a closed middle ear, raising or lowering ICP by positioning also had the effect of raising or lowering middle-ear pressure. With an open middle ear, raising or lowering middle-ear pressure resulted in congruent increases of the SP and the SP/AP ratio and, though the AP remained steady, it showed much higher voltage values. With an open middle ear, the baseline SP and baseline SP/AP ratio were reduced, but the reduction of the SP/AP ratio was mainly due to an increased AP. With an open middle ear, the SP, the SP/AP ratio, and the AP did not change appreciably during positioning-induced ICP changes. This suggests that ICP changes by positioning are not very effective in the rat when the middle ear is open. Thus, the effect of ICP changes with the middle ear closed are mainly due to positioning-induced pressure changes in the middle ear. Our findings confirm that static middle-ear pressure is critical for the cochlea and that good eustachian tube function is essential to keeping the pressure gradient across the round-window membrane as small as possible, the latter possibly assisted by a Windkessel function of the round-window membrane. However, relatively small pressure changes in the middle ear can overwhelm it, which suggests a very limited Windkessel function. In Ménière's disease, sensitivity to static pressure changes is possibly exaggerated. The insertion of a middle-ear ventilation tube, as practiced in treating selected cases of Ménière's disease, could restore Windkessel function. It has a stabilizing effect, as the inner ear appears less pressure-sensitive. This effect decreases Ménière's disease symptoms, but it is not without consequences. After the insertion of a middle-ear ventilation tube, a reduced SP/AP ratio is no evidence of improved inner-ear function. Its consequences are enlarged AP voltages, very likely loss of middle-ear dampening, and possible increased ringing.


Assuntos
Potenciais de Ação/fisiologia , Audiometria de Resposta Evocada , Orelha Média/fisiopatologia , Pressão Intracraniana/fisiologia , Animais , Deglutição/fisiologia , Tuba Auditiva/fisiopatologia , Doença de Meniere/fisiopatologia , Ventilação da Orelha Média , Postura/fisiologia , Ratos , Ratos Sprague-Dawley , Janela da Cóclea/fisiopatologia , Membrana Timpânica/fisiopatologia , Membrana Timpânica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA