Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 328
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Sleep Breath ; 24(4): 1339-1347, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31768931

RESUMO

PURPOSE: Oral appliances (OA) are used to treat patients with obstructive sleep apnea (OSA). The purpose of this study is to evaluate the efficacy of OA treatment in patients with rapid eye movement (REM)-related OSA. METHODS: Forty-six patients with REM-related OSA and 107 with non-stage-specific OSA were prescribed OA treatment after diagnosis by polysomnography (PSG) and a follow-up sleep test by PSG was conducted. Efficacy and treatment outcome predictors were evaluated according to the following criteria for treatment success: #1, reduction of the apnea-hypopnea index (AHI) to less than 5 and > 50% compared with baseline; #2, AHI reduction to less than 10 and > 50% compared with baseline; and #3, > 50% AHI reduction compared with baseline. RESULTS: Success rates according to criteria #1, #2, and #3 were 45.7%, 50.0%, and 50.0% in REM-related OSA and 36.4%, 52.3%, and 63.6% in non-stage-specific OSA, respectively. No significant differences in success rate were found between the two groups. In multivariate logistic regression analysis with each criterion as the response variable, only BMI was extracted as a significant predictor. The BMI cutoff values defined based on the maximum Youden index according to the three criteria were 26.2 kg/m2, 25.6 kg/m2, and 26.2 kg/m2, respectively. CONCLUSIONS: No significant differences in success rate of OA treatment were found between REM-related OSA and non-stage-specific OSA. BMI has greater impact on treatment outcome of OA in patients with REM-related OSA.


Assuntos
Ortodontia/instrumentação , Ortodontia/métodos , Apneia Obstrutiva do Sono/terapia , Sono REM/fisiologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Estudos Retrospectivos , Apneia Obstrutiva do Sono/fisiopatologia , Resultado do Tratamento
2.
Ann Pharm Fr ; 77(3): 232-240, 2019 May.
Artigo em Francês | MEDLINE | ID: mdl-30961889

RESUMO

OBJECTIVES: As a university teaching hospital, the call for tender for dental medical devices (dental implants and consumables) is done with the help of a team of hospital pharmacists and users. In order to optimize the definition of needs and evaluation criteria, an exhaustive review of the products was carried out. METHODS: Dental medical devices suppliers were consulted in 2017 for reviewing their products. Their technical, clinical and economic data were compared. The products have been gathered into categories and its results had been submitted to a commission of dental experts of our university hospital for clinical opinion. RESULTS: More than 30,000 references from 30 different suppliers were analyzed (orthodontics, dental implants, membranes and bone substitutes, various dental consumables). Relating to oral implantology, the opinions converged on clinical studies. On the contrary, diverging opinions have been proffered on the systematic use of single-use drills and customized guides for surgery and on the implant's choice. The definition of needs has been specified for orthodontics and consumables. Other criteria played a great role: single packaging (unit doses), product's sterility, paediatric needs, presence of allergens, traceability of devices and supplier diversity. CONCLUSIONS: This review led to the identification of new needs in more precise terms. The complexity and diversity of dental products and techniques requires this careful review and a better collaboration with practitioners.


Assuntos
Odontologia/normas , Equipamentos e Provisões/normas , Alérgenos/análise , Substitutos Ósseos , Implantes Dentários , Instrumentos Odontológicos , França , Hospitais Universitários , Humanos , Ortodontia/instrumentação , Farmacêuticos , Serviço de Farmácia Hospitalar , Esterilização/normas , Cirurgia Bucal/instrumentação
3.
Niger J Clin Pract ; 22(12): 1644-1653, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31793469

RESUMO

OBJECTIVES: To assess the validity of using the calibration ruler for correcting magnification of linear measurements and to explore and compare the vertical and horizontal magnification of four digital cephalometric units. METHODS: An acrylic box was imaged at seven sagittal positions using four digital cephalometric units: Orthopantomograph OC100, Orthopantomograph OC200, Sirona Orthophos CD, and Sirona Orthophos DS. The true linear lengths of the phantom, corrected, and uncorrected linear lengths on the images were measured and compared. The validity of measurements using the calibration ruler was assessed. The magnification values and distortion indices were calculated and compared among the four cephalometric units. RESULTS: For linear measurements on the mid-sagittal plane and averaged linear measurements on bilateral symmetric sagittal planes, the bias 1.96 STD of the calibration ruler ranged from 1% to 2% for the four cephalometric testing units. For linear measurements on the single lateral sagittal plane, the bias 1.96 STD ranged from 3% to 6%. The vertical scanning charge-coupled device cephalometric unit produced the greatest distortion, ranging from 1.029 to 0.964. CONCLUSION: The metal millimeter calibration ruler is an accurate reference for linear measurement magnification correction. Because of unpredictability and machine specificity, the magnification and distortion of a cephalometric unit should be calibrated for the estimation of cephalometric measurement error.


Assuntos
Calibragem/normas , Cefalometria/métodos , Radiografia Dentária Digital/instrumentação , Algoritmos , Cefalometria/normas , Humanos , Ortodontia/instrumentação , Imagens de Fantasmas , Ampliação Radiográfica , Radiografia Dentária Digital/métodos , Radiografia Panorâmica , Ecrans Intensificadores para Raios X
4.
J Contemp Dent Pract ; 19(6): 698-703, 2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-29959299

RESUMO

AIM: This study aimed to compare the efficiency of various sterilization procedures using conventional spore monitoring method, i.e., by using swab test and biological indicators and to determine the efficiency of cold sterilization by using Bioclenz-G (2% glutaraldehyde) solution. MATERIALS AND METHODS: Each group was divided into medium load (containing 15 sets of instruments) and heavy load (containing 30 sets of instruments). Each group was tested 15 times for medium and heavy loads. Two groups are swab tested control group and experimental group with three different methods of sterilization: hot air oven, cold sterilization, and ethylene dioxide sterilization. RESULTS: Spores were present in all the groups tested for 10 minutes cycle, in comparison with no spore growth in any of the groups tested for a 10-hour cycle. CONCLUSION: All methods of sterilization showed complete sterilization of instruments when monitored with biological indicators. One group of heavy load in steam autoclave and one group each of medium load and heavy load in hot air oven sterilizer showed sterilization failure when monitored with the conventional swab test method. CLINICAL SIGNIFICANCE: This study proves the efficacy and durability of various sterilization procedures.


Assuntos
Ortodontia/instrumentação , Esterilização/métodos , Temperatura Baixa , Contaminação de Equipamentos , Temperatura Alta , Ortodontia/métodos , Esporos Bacterianos/efeitos dos fármacos
5.
Am J Orthod Dentofacial Orthop ; 151(5): 995-1003, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28457278

RESUMO

INTRODUCTION: Accurate articulation of the digital dental casts is crucial in orthodontic diagnosis and treatment planning. We aimed to determine the accuracy of manufacturing digital dental casts from computed tomography scanning of plaster casts regarding linear dimensions and interarch relationships and to test whether eventual differences in interarch relationships between plaster and digital casts would affect orthodontic diagnostics. METHODS: Plaster casts with the wax bites of 2 patients were used to create digital dental casts with a computed tomography scanner. This was repeated 4 times with a 1-week interval. Linear distances were measured on plaster and digital models twice by 2 observers. Next, the 4 digital models of each patient were scored twice by 5 observers for interarch variables. RESULTS: Digital vs plaster measurements showed high Pearson correlation coefficients (>0.954), whereas the mean difference was small (<0.1 mm) and not significant. The interarch scorings, however, showed significant differences for all variables, except overjet for model 1. CONCLUSIONS: We found substantial interarch inaccuracies of the digital models. These inaccuracies are probably due to a lack of built-in "collision control" in the software and manual articulation of the digital models by a human operator.


Assuntos
Modelos Dentários , Ortodontia/métodos , Tomografia Computadorizada por Raios X , Arco Dental/diagnóstico por imagem , Arco Dental/patologia , Humanos , Má Oclusão/diagnóstico por imagem , Má Oclusão/patologia , Maxila/diagnóstico por imagem , Maxila/patologia , Ortodontia/instrumentação , Reprodutibilidade dos Testes , Dente/diagnóstico por imagem , Dente/patologia
6.
Evid Based Dent ; 18(1): 26-27, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28338029

RESUMO

Data sourcesCochrane Oral Health Group's Trials Register, the Cochrane Central Register of Controlled Trials (CENTRAL), Medline, Embase, LILACS, the metaRegister of Controlled Trials, the US National Institutes of Health Trials Register and the WHO International Clinical Trials Registry Platform.Study selectionRandomised controlled trials of orthodontic treatment using fixed appliances along with non-surgical adjunctive interventions to accelerate tooth movement.Data extraction and synthesisTwo reviewers independently selected studies, abstracted data and assessed risk of bias. Meta-analysis was not possible.ResultsTwo studies involving a total of 111 patients were included, both were at high risk of bias. The studies compared the use of Tooth Masseuse and OrthoAccel with conventional treatment mechanics. Using OrthoAccel with 30 Hz at 0.25 N for 20 minutes daily produced a higher rate of maxillary canine distalisation in comparison to the control group (MD 0.37 mm/month; 95% CI -0.07 to 0.81; P = 0.05). Whilst this difference suggested 50% faster tooth movement using the vibrational appliance, the absolute differences were marginal and deemed clinically unimportant. Similar levels of non-serious adverse effects were reported in the intervention and control groups with a risk ratio of 0.96 (95% CI 0.32 to 2.85). Overall, the quality of the evidence was very low and therefore we cannot rely on the findings.ConclusionsThere is very little clinical research concerning the effectiveness of non-surgical interventions to accelerate orthodontic treatment. The available evidence is of very low quality and so it is not possible to determine if there is a positive effect of non-surgical adjunctive interventions to accelerate tooth movement. Although there have been claims that there may be a positive effect of light vibrational forces, results of the current studies do not reach either statistical or clinical significance. Further well-designed and rigorous RCTs with longer follow-up periods are required to determine whether non-surgical interventions may result in a clinically important reduction in the duration of orthodontic treatment, without any adverse effects.


Assuntos
Odontologia Baseada em Evidências/instrumentação , Odontologia Baseada em Evidências/métodos , Aparelhos Ortodônticos , Ortodontia/instrumentação , Ortodontia/métodos , Técnicas de Movimentação Dentária , Adolescente , Feminino , Humanos , Masculino , Estados Unidos , Adulto Jovem
7.
Am J Orthod Dentofacial Orthop ; 150(6): 1056-1062, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27894527

RESUMO

INTRODUCTION: Dental models fabricated with 3-dimensional printing technologies are revolutionizing the practice of orthodontics, but they generally comprise polymeric materials that may not be suitable for certain applications, such as soldering appliances. The objective of this study was to investigate the dimensional accuracy and mechanical properties of 3-dimensional printed ceramic-based models before and after various treatments intended to improve their mechanical properties. METHODS: Thirty identical models were printed 3-dimensionally from a calcium sulfate-based substrate and divided into 3 groups for treatment: high heat (250°C for 30 minutes), low heat (150°C for 30 minutes), and Epsom salt treatment. Each model was scanned before and after treatment with a laser scanner, and dimensional stability was analyzed by digital superimpositions using a best-fit algorithm. The models were weighed before and after treatment to evaluate mass changes. Additionally, 3-dimensional printed cylinders treated as described above and an untreated control group were subjected to compressive mechanical testing (n = 11 per group). RESULTS: The Epsom salt treatment group had statistically significant increases in both peak compressive stress and modulus of elasticity when compared with the other treatment groups. All treatment groups had statistically significant changes in mass, with the Epsom salt group gaining mass and the 2 heat-treatment groups losing mass. The low-temperature treatment group had a statistically significantly lower mean average for dimensional deviations (0.026 ± 0.010 mm) than did the other treatment groups (0.069 ± 0.006 and 0.059 ± 0.010 mm for high temperature and Epsom salt, respectively). CONCLUSIONS: Dental models printed 3-dimensionally with calcium sulfate and treated with Epsom salt showed significant improvement in compressive mechanical properties and retained clinically acceptable dimensional stability.


Assuntos
Modelos Dentários , Impressão Tridimensional/normas , Sulfato de Cálcio/uso terapêutico , Cerâmica/uso terapêutico , Força Compressiva , Elasticidade , Humanos , Modelos Dentários/normas , Ortodontia/instrumentação , Ortodontia/métodos , Reprodutibilidade dos Testes , Estresse Mecânico
8.
J Mater Sci Mater Med ; 26(1): 5391, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25595723

RESUMO

This study investigated the possibility of electrical and laser welding to connect titanium-based alloy (beta-titanium and nickel-titanium) wires and stainless-steel or cobalt-chromium alloy wires for fabrication of combination arch-wires. Four kinds of straight orthodontic rectangular wires (0.017 × 0.025 inch) were used: stainless-steel (S-S), cobalt-chromium (Co-Cr), beta-titanium alloy (ß-Ti), and nickel-titanium (Ni-Ti). Homogeneous and heterogeneous end-to-end joints (15 mm long each) were made by electrical welding and laser welding. Non-welded wires (30 mm long) were also used as a control. Maximum loads at fracture (N) and elongation (%) were measured by conducting tensile test. The data (n = 10) were statistically analyzed using analysis of variance/Tukey test (P < 0.05).The S-S/S-S and Co-Cr/Co-Cr specimens showed significantly higher values of the maximum load (ML) at fracture and elongation (EL) than those of the Ni-Ti/Ni-Ti and ß-Ti/ß-Ti specimens for electrical welding and those of the S-S/S-S and Co-Cr/Co-Cr specimens welded by laser. On the other hand, the laser-welded Ni-Ti/Ni-Ti and ß-Ti/ß-Ti specimens exhibited higher values of the ML and EL compared to those of the corresponding specimens welded by electrical method. In the heterogeneously welded combinations, the electrically welded Ni-Ti/S-S, ß-Ti/S-S and ß-Ti/Co-Cr specimens showed significantly (P < 0.05) higher ML and EL than those of the corresponding specimens welded by laser. Electrical welding exhibited the higher values of maximum load at fracture and elongation for heterogeneously welded combinations than laser-welding.


Assuntos
Fios Ortodônticos , Ortodontia/instrumentação , Ortodontia/métodos , Titânio/química , Ligas , Cromo/química , Cobalto/química , Humanos , Lasers , Teste de Materiais , Níquel/química , Reprodutibilidade dos Testes , Aço Inoxidável , Estresse Mecânico , Resistência à Tração , Dente
9.
Lasers Med Sci ; 30(2): 611-6, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23812850

RESUMO

One possible undesirable consequence of orthodontic therapy is the development of incipient caries lesions of enamel around brackets. The aim of this study was to compare the effects of CO2 (λ = 10.6 µm) and Nd:YAG (λ = 1,064 nm) lasers associated or not with topical fluoride application on the prevention of caries lesions around brackets. Brackets were bonded to the enamel of 65 premolars. The experimental groups (n = 13) were: G1--application of 1.23% acidulated fluoride phosphate gel (AFP, control); G2--Nd:YAG laser irradiation (0.6 W, 84.9 J/cm(2), 10 Hz, 110 µs, contact mode); G3--Nd:YAG laser irradiation associated with AFP; G4--CO2 laser irradiation (0.5 W, 28.6 J/cm(2), 50 Hz, 5 µs, and 10 mm focal distance); and G5--CO2 laser irradiation associated with AFP. Quantitative light-induced fluorescence was used to assess enamel demineralization. The data were statistically compared (α = 5%). The highest demineralization occurred in the Nd:YAG laser group (G2, 26.15% ± 1.94). The demineralization of all other groups was similar to that of the control group. In conclusion, CO2 laser alone was able to control enamel demineralization around brackets at the same level as that obtained with topical fluoride application.


Assuntos
Dente Pré-Molar/cirurgia , Cárie Dentária/prevenção & controle , Esmalte Dentário/efeitos da radiação , Lasers de Gás , Lasers de Estado Sólido , Braquetes Ortodônticos/efeitos adversos , Fluoretos/química , Humanos , Metais , Neodímio , Ortodontia/instrumentação , Fosfatos/química
10.
J Orthod ; 42(2): 136-43, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25939980

RESUMO

The popularity and availability of virtual technology in orthodontics for the replacement of hard-copy records with electronic records is growing rapidly, with a move towards a 'digital' patient for diagnosis, treatment planning, monitoring of treatment progress and outcome. As part of this ongoing development, three-dimensional digital models of the dental arches have the potential to replace traditional plaster models and their associated limitations for treatment planning, appliance construction and simulated treatment outcomes. This article provides the reader with a summary of the currently available benchtop model scanners and intraoral scanners. It is likely that this technology will become increasingly common-place within the orthodontic profession over the next decade.


Assuntos
Imagem Óptica/instrumentação , Ortodontia/instrumentação , Computação em Nuvem , Técnica de Moldagem Odontológica/instrumentação , Registros Odontológicos , Registros Eletrônicos de Saúde , Desenho de Equipamento , Humanos , Imageamento Tridimensional/métodos , Armazenamento e Recuperação da Informação , Modelos Dentários , Tecnologia Odontológica/instrumentação , Interface Usuário-Computador
11.
J Contemp Dent Pract ; 16(8): 619-23, 2015 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-26423496

RESUMO

AIM: To compare the antimicrobial activity of the chemical substances--70% isopropyl alcohol, 2% glutaraldehyde (GTA) and 0.25% peracetic acid (PAA) in disinfecting orthodontic pliers contaminated in vitro with Streptococcui mutani, Staphylococci aureui and Candida albicani. MATERIALS AND METHODS: Distal end cutter pliers were divided into five groups: group 1 (negative control--sterilized pliers), group 2 (positive control--sterilized plier, subsequently contaminated), group 3 (disinfected with 70% isopropyl alcohol, friction method), group 4 (disinfected with 2% GTA, immersion method for 30 minutes), group 5 (disinfected with 0.25% peracetic acid (PAA), immersion method for 10 minutes). After the pliers were treated with one disinfectant and submitted to microbiological evaluation (by counting colony forming units), they were submitted to the same cleansing, sterilizing and contaminating processes, and were used in the following groups (crossover and washout study). The two-factor analysis of variance (ANOVA) test, followed by the Tukey test, was used to compare the groups. RESULTS: The results showed that there was no statistically significant difference between the three tested disinfectants. CONCLUSION: Although there were no statistically significant differences between the disinfectants, the chemical agents 2% glutaraldehyde and 0.25% PAA were effective in inhibiting the growth of the three microorganisms tested; however, 70% isopropyl alcohol was unable to completely eliminate S. aureui. CLINICAL SIGNIFICANCE: The chemical substances 2% glutaraldehyde and 0.25% PAA completely eliminated the microorganisms tested.


Assuntos
Anti-Infecciosos/farmacologia , Bactérias/efeitos dos fármacos , Instrumentos Odontológicos/microbiologia , Desinfecção/métodos , Contaminação de Equipamentos/prevenção & controle , Ortodontia/instrumentação , 2-Propanol/farmacologia , Candida albicans/efeitos dos fármacos , Contagem de Colônia Microbiana , Glutaral/farmacologia , Humanos , Ácido Peracético/farmacologia , Streptococcus/efeitos dos fármacos
12.
Lasers Med Sci ; 29(5): 1563-8, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23568626

RESUMO

Rebonding of a dislodge bracket is considered as an economic saving option which can be done with use of in-office methods or by commercial recycling. The aim of this study was to compare the shear rebond strength (SRS) of brackets recycled with different resin removal methods. Eighty premolars were divided into four experimental groups. The teeth were bonded with metal brackets. The brackets were debonded and adhesive remnants were removed from bracket bases by means of Er:YAG laser, sandblasting, direct flame, and CO2 laser, respectively. Following adhesive removal from enamel surfaces with carbide bur, recycled brackets were rebonded. Finally, all brackets were debonded with a Dartec testing machine and the SRS values were determined. The SRS values of groups 3 and 4 were significantly lower compare to other groups (P value < 0.001). SEM examination showed complete adhesive removal from bracket base cleaned with Er:YAG laser irradiation. Microroughening of the base of sandblasted bracket was observed in the SEM image. Resin removal with direct flame and CO2 laser irradiation was incomplete. Er:YAG laser recycling of brackets is an efficient in-office method of reconditioning which caused minimum damage to the bracket base.


Assuntos
Colagem Dentária/instrumentação , Braquetes Ortodônticos , Adesividade , Adesivos , Dente Pré-Molar , Dióxido de Carbono , Colagem Dentária/métodos , Esmalte Dentário , Humanos , Lasers , Lasers de Estado Sólido , Teste de Materiais , Microscopia Eletrônica de Varredura , Ortodontia/instrumentação , Ortodontia/métodos , Pressão , Resistência ao Cisalhamento , Propriedades de Superfície
14.
Eur J Orthod ; 36(3): 303-13, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23873818

RESUMO

INTRODUCTION: The aim of this study was to review the literature and evaluate the failure rates and factors that affect the stability and success of temporary anchorage devices (TADs) used as orthodontic anchorage. METHODS: Data were collected from electronic databases: MEDLINE database, Scopus, and Web of Knowledge. Four combinations of term were used as keywords: screw orthodontic failure, screw orthodontic success, implant orthodontic failure, and implant orthodontic success. The following selection criteria were used to select appropriate articles: articles on implants and screws used as orthodontic anchorage, data only from human subjects, studies published in English, studies with more than 50 implants/screws, and both prospective and retrospective clinical studies. RESULTS: The search provided 209 abstracts about TADs used as anchorage. After reading and applying the selection criteria, 26 articles were included in the study. The data obtained were divided into two topics: which factors affected TAD success and to what degree and in how many articles they were quoted. Clinical factors were divided into three main groups: patient-related, implant-related, and management-related factors. CONCLUSIONS: Although all articles included in this meta-analysis reported success rates of greater than 80 per cent, the factors determining success rates were inconsistent between the studies analysed and this made conclusions difficult.


Assuntos
Procedimentos de Ancoragem Ortodôntica/instrumentação , Placas Ósseas , Parafusos Ósseos , Implantes Dentários , Humanos , Desenho de Aparelho Ortodôntico , Ortodontia/instrumentação , Estudos Prospectivos , Falha de Prótese , Estudos Retrospectivos
15.
Int J Orthod Milwaukee ; 25(2): 21-30, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25109055

RESUMO

Sterilization and disinfection have been a matter of concern amongst dental health care workers since long. Delicate materials, electrical parts, orthodontic pliers, orthodontic wire cutters, are to be treated according to the manufacturer's instructions to safe guard the life of the instrument as well as to claim warranty for any damage incurred. Sterilization procedures used in Orthodontics should be simple but effective and of relatively short duration so that there is a readily available supply of sterile instruments and materials. The procedure should not cause any appreciable damage to dental instruments and other materials. An attempt has been made through this article, to provide information concerning methods and means of disinfection and sterilization of orthodontic clinics, instruments, materials and also waste disposal which can be adopted in private clinics as well as in hospital set ups.


Assuntos
Consultórios Odontológicos , Ortodontia , Esterilização/métodos , Desinfetantes de Equipamento Odontológico/uso terapêutico , Equipamentos Odontológicos/microbiologia , Instrumentos Odontológicos/microbiologia , Materiais Dentários/química , Resíduos Odontológicos , Desinfetantes/uso terapêutico , Desinfecção/métodos , Equipamentos e Provisões Elétricas/microbiologia , Monitoramento Ambiental/métodos , Contaminação de Equipamentos/prevenção & controle , Arquitetura de Instituições de Saúde , Pisos e Cobertura de Pisos , Desinfecção das Mãos/métodos , Humanos , Controle de Infecções Dentárias/métodos , Eliminação de Resíduos de Serviços de Saúde/métodos , Aparelhos Ortodônticos/microbiologia , Ortodontia/instrumentação , Roupa de Proteção , Esterilização/instrumentação , Precauções Universais
16.
Angle Orthod ; 94(4): 375-382, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-39229951

RESUMO

OBJECTIVES: To determine the impact of build orientation, increased layer thickness, and dental crowding on the trueness of three-dimensional (3D)-printed models, and to evaluate how these parameters affect the fit of thermoformed appliances. MATERIALS AND METHODS: Ninety-six dental models were printed horizontally and vertically on the building platform using different 3D-printing technologies: (1) a stereolithography (SLA) printer with layer thicknesses of 160 µm and 300 µm and (2) a digital light processing (DLP) printer with layer thicknesses of 100 µm and 200 µm. Each printed model was digitalized and superimposed on the corresponding source file using 3D rendering software, and deviations were quantified by the root mean square values. Subsequently, a total of 32 thermoformed appliances were fabricated on top of the most accurate 3D-printed models, and their fit was evaluated by digital superimposition and inspection by three blinded orthodontists. Paired t-tests were used to analyze the data. RESULTS: Significant differences (P < .05) between printing technologies used were identified for models printed horizontally, with the SLA system achieving better trueness, especially in crowded dentitions. No significant differences between technology were found when models were printed vertically. The highest values of deviation were recorded in appliances fabricated on top of DLP-printed models. The results of the qualitative evaluation indicated that appliances fabricated on top of SLA models outperformed the DLP-modeled appliances. CONCLUSIONS: Three-dimensional printing with increased layer height seems to produce accurate working models for orthodontic applications.


Assuntos
Modelos Dentários , Impressão Tridimensional , Humanos , Estereolitografia , Desenho de Aparelho Ortodôntico , Desenho Assistido por Computador , Ortodontia/métodos , Ortodontia/instrumentação
17.
Minerva Dent Oral Sci ; 73(3): 134-141, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38743249

RESUMO

BACKGROUND: Mobile phone applications (apps) can potentially enhance patient care as they are easy to use and offer multifunctions. In 2019, 305 orthodontic apps were documented, many of which were patient-focused; however, there was little information on how popular these applications are with orthodontic patients. The main aim of this study was to evaluate how well patients were now aware of orthodontic applications. METHODS: A survey asking 700 orthodontic patients about their knowledge of, access to, and use of orthodontic apps to facilitate their treatment resulted in 615 responses. RESULTS: The results showed that a smartphone was owned by 96% of patients. Apple (Apple Inc., Cupertino, CA, USA) was the most used platform, followed by Android (Google LLC, Mountain View, CA, USA). Seventy-five percent of patients have previously used social media to research information, with YouTube (YouTube, San Mateo, CA, USA) being the most popular site. Only 3% of patients knew that applications were available to aid with orthodontic therapy and 12 patients had utilized an app linked to orthodontics. Nevertheless, 88% of patients said they would be open to using an app to supplement their treatment. CONCLUSIONS: Although 88% of patients said they would be prepared to use an app to help with orthodontic treatment, there is currently a low level of knowledge of the existence of apps. Given the availability of applications geared toward those patients, it is necessary to evaluate these apps' quality and, when critical, direct patients toward high-quality, efficient apps.


Assuntos
Aplicativos Móveis , Smartphone , Humanos , Masculino , Feminino , Adulto , Adolescente , Ortodontia/métodos , Ortodontia/instrumentação , Inquéritos e Questionários , Adulto Jovem , Pessoa de Meia-Idade , Conhecimentos, Atitudes e Prática em Saúde
18.
Curr Pharm Des ; 30(19): 1490-1506, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38644722

RESUMO

Orthodontic pain is characterized by sensations of tingling, tooth discomfort, and intolerance. According to the oral health report, over forty percent of children and adolescents have undergone orthodontic treatment. The efficacy of orthodontic treatment involving braces can be compromised by the diverse levels of discomfort and suffering experienced by patients, leading to suboptimal treatment outcomes and reduced patient adherence. Nanotechnology has entered all areas of science and technology. This review provides an overview of nanoscience, its application in orthodontics, the underlying processes of orthodontic pain, effective treatment options, and a summary of recent research in Nano-dentistry. The uses of this technology in healthcare span a wide range, including enhanced diagnostics, biosensors, and targeted drug delivery. The reason for this is that nanomaterials possess distinct qualities that depend on their size, which can greatly enhance human well-being and contribute to better health when effectively utilized. The field of dentistry has also experienced significant advancements, particularly in the past decade, especially in the utilization of nanomaterials and technology. Over time, there has been an increase in the availability of dental nanomaterials, and a diverse array of these materials have been extensively studied for both commercial and therapeutic purposes.


Assuntos
Sistemas de Liberação de Medicamentos , Nanoestruturas , Ortodontia , Dor , Ortodontia/instrumentação , Ortodontia/métodos , Ortodontia/tendências , Dor/tratamento farmacológico , Dor/etiologia , Dor/patologia , Nanoestruturas/química , Nanoestruturas/uso terapêutico , Sistemas de Liberação de Medicamentos/tendências , Humanos , Aparelhos Ortodônticos/efeitos adversos , Manejo da Dor/tendências , Analgésicos/química , Analgésicos/uso terapêutico
19.
Sensors (Basel) ; 13(2): 2033-50, 2013 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-23385416

RESUMO

In the field of dental health care, plaster models combined with 2D radiographs are widely used in clinical practice for orthodontic diagnoses. However, complex malocclusions can be better analyzed by exploiting 3D digital dental models, which allow virtual simulations and treatment planning processes. In this paper, dental data captured by independent imaging sensors are fused to create multi-body orthodontic models composed of teeth, oral soft tissues and alveolar bone structures. The methodology is based on integrating Cone-Beam Computed Tomography (CBCT) and surface structured light scanning. The optical scanner is used to reconstruct tooth crowns and soft tissues (visible surfaces) through the digitalization of both patients' mouth impressions and plaster casts. These data are also used to guide the segmentation of internal dental tissues by processing CBCT data sets. The 3D individual dental tissues obtained by the optical scanner and the CBCT sensor are fused within multi-body orthodontic models without human supervisions to identify target anatomical structures. The final multi-body models represent valuable virtual platforms to clinical diagnostic and treatment planning.


Assuntos
Imageamento Tridimensional/instrumentação , Modelos Dentários , Ortodontia/instrumentação , Adolescente , Tomografia Computadorizada de Feixe Cônico , Feminino , Humanos , Boca/anatomia & histologia
20.
Am J Orthod Dentofacial Orthop ; 144(6): 802-17, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24286904

RESUMO

INTRODUCTION: The increasing use of cone-beam computed tomography in orthodontics has been coupled with heightened concern about the long-term risks of x-ray exposure in orthodontic populations. An industry response to this has been to offer low-exposure alternative scanning options in newer cone-beam computed tomography models. METHODS: Effective doses resulting from various combinations of field of view size and field location comparing child and adult anthropomorphic phantoms with the recently introduced i-CAT FLX cone-beam computed tomography unit (Imaging Sciences, Hatfield, Pa) were measured with optical stimulated dosimetry using previously validated protocols. Scan protocols included high resolution (360° rotation, 600 image frames, 120 kV[p], 5 mA, 7.4 seconds), standard (360°, 300 frames, 120 kV[p], 5 mA, 3.7 seconds), QuickScan (180°, 160 frames, 120 kV[p], 5 mA, 2 seconds), and QuickScan+ (180°, 160 frames, 90 kV[p], 3 mA, 2 seconds). Contrast-to-noise ratio was calculated as a quantitative measure of image quality for the various exposure options using the QUART DVT phantom. RESULTS: Child phantom doses were on average 36% greater than adult phantom doses. QuickScan+ protocols resulted in significantly lower doses than standard protocols for the child (P = 0.0167) and adult (P = 0.0055) phantoms. The 13 × 16-cm cephalometric fields of view ranged from 11 to 85 µSv in the adult phantom and 18 to 120 µSv in the child phantom for the QuickScan+ and standard protocols, respectively. The contrast-to-noise ratio was reduced by approximately two thirds when comparing QuickScan+ with standard exposure parameters. CONCLUSIONS: QuickScan+ effective doses are comparable with conventional panoramic examinations. Significant dose reductions are accompanied by significant reductions in image quality. However, this trade-off might be acceptable for certain diagnostic tasks such as interim assessment of treatment results.


Assuntos
Tomografia Computadorizada de Feixe Cônico/instrumentação , Ortodontia/instrumentação , Imagens de Fantasmas , Doses de Radiação , Radiometria/métodos , Adulto , Análise de Variância , Cefalometria , Criança , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Ortodontia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA