1.
Am J Otolaryngol ; 45(4): 104273, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38574515

RESUMO

OBJECTIVE: To summarize adverse events and their root causes reported to the United States Food and Drug Administration (FDA) on Vibrant Soundbridge (VSB) hearing device (Med-El, Innsbruck, Austria), an active middle ear implant for patients with moderate to severe hearing loss. MATERIALS AND METHODS: The FDA's Manufacturer and User Facility Device Experience (MAUDE) database was queried for reports of VSB adverse events from January 1, 2012, to July 27, 2022. RESULTS: Six hundred sixty-three total medical device reports were identified, from which 913 adverse events were extracted. Of these, 498 (54.5 %) were adverse events to patients (AEPs), while 415 (45.5 %) were device malfunctions (DMs). The most common AEPs were hearing performance issues 428 (85.9 %). The most common DMs were compromised conductive link 125 (30.1 %). Root causes identified for DMs were iatrogenic 85 (58.6 %), patient-related 28 (19.3 %), and trauma and external causes 32 (22.1 %). The most common iatrogenic root cause 12 (14.1 %) involved damage to the conductive link during revision surgery. The most common patient-related causes of DMs were excessive middle ear tissue growth 16 (57 %), and abrupt body movements 5 (28.6 %). The most common external cause of DM was cleaning of the ear canal or mastoid cavity 20 (62.5 %). CONCLUSIONS: Despite its well-known limitations, the MAUDE database provides valuable information on possible complications of VSB as it relates to device malfunction or adverse events for patients. Implementation of standardized reports with relevant and well-defined categories could certainly allow for a more meaningful analysis.


Assuntos
Prótese Ossicular , Humanos , Estados Unidos , United States Food and Drug Administration , Bases de Dados Factuais , Falha de Prótese , Perda Auditiva/etiologia
2.
Eur Arch Otorhinolaryngol ; 281(5): 2333-2340, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38070046

RESUMO

BACKGROUND: The objective-based methods for intraoperative monitoring have been suggested to assess the coupling and the outcomes of Vibrant Soundbridge (VSB). Although several techniques were proposed, they have not been widely adopted due to their complexity and invasiveness. PURPOSE: This study aimed to investigate the accuracy of a new coupling quality index using an intraoperative ABR threshold via AcoustiAP and its correlation with the perioperative measures. METHODS: This is a prospective study conducted at a tertiary center. The medical records were retrieved for all patients who underwent VSB implantation and had an intraoperative objective assessment for the coupling efficiency. AcoustiAP was used to evaluate the intraoperative ABR thresholds, which were assessed directly after the floating mass transducer (FMT) placement using acoustic CE-Chirp signals. The Vibrogram was used for the postoperative audiological evaluation. A new coupling quality index was calculated based on the intraoperative ABR thresholds. RESULTS: Ten patients were eligible for the present study. The ABR thresholds for good coupling ranged from 35 to 60 dBnHL. The loose coupling thresholds ranged considerably from 40 to 100 dBnHL. Overall, the median intraoperative ABR threshold at good coupling was 42.5 (40-60) dBnHL and 60 (40-100) dBnHL at loose coupling. The analysis showed that there was a significant change in the coupling quality index at the good and loose coupling points (24.3 ± 14 vs 38.8 ± 18.2, respectively, p < 0.001). At a cut-off value of 22.6 dB, the coupling quality index had a sensitivity of 70%  and specificity of 90% for discriminating good and loose coupling. CONCLUSION: This study provides evidence for the utility of intraoperative ABR measurements in predicting the coupling efficiency in patients with VSB. Our results showed that the coupling quality index had an acceptable accuracy in discriminating between good and poor coupling, which can help clinicians optimize the fitting process for individuals and may ultimately lead to improved patient outcomes.


Assuntos
Prótese Ossicular , Humanos , Estudos Prospectivos , Audiometria
3.
Eur Arch Otorhinolaryngol ; 281(5): 2353-2363, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38133806

RESUMO

PURPOSE: This multicentric, retrospective study aimed to analyze the short-term safety and effectiveness of the mCLIP Partial Prosthesis. METHODS: Patients underwent tympanoplasty with implantation of a mCLIP Partial Prosthesis. Follow-up examination included ear microscopy and pure-tone audiometry to determine the post-operative pure tone average of the frequencies 0.5, 1, 2 and 3 kHz (PTA4). The post-operative PTA4 air bone gap (ABG) was used to evaluate the audiological outcome. A post-operative minimum and maximum follow-up period was not defined. Thus, the follow-up times of each study center were different, which resulted in different follow-up times for the audiological analysis and for adverse events (AE). RESULTS: 72 (66 adults, 6 children) patients were implanted with the mCLIP Partial Prosthesis. 68 (62 adults, 6 children) patients underwent audiological examination; all 72 patients were examined for adverse events. All patients (N = 68): 72.1% of the patients showed a PTA4 ABG of ≤ 20 dB. Individual post-operative bone conduction (BC) PTA4 thresholds were stable in 67 patients. The mean post-operative follow-up time was 78 ± 46 days. Children (N = 6): 5 out of 6 children showed a PTA4 ABG of ≤ 20 dB. None of the children reported a BC PTA4 deterioration of > 10 dB HL after the implantation. The mean post-operative follow-up time was 101 ± 45 days. Adverse events (all patients, N = 72): 15 (14 adults, 1 child) patients had AEs (27 AEs and 2 Follow-Ups). The mean post-operative follow-up time was 375 days. CONCLUSION: Clinical data show satisfactory audiological parameters after implantation of the mCLIP Partial Prosthesis. The prosthesis is safe and effective for implantation in children and adults. TRIAL REGISTRATION NUMBER: NCT05565339, 09 September 2022, retrospectively registered.


Assuntos
Prótese Ossicular , Adulto , Criança , Humanos , Resultado do Tratamento , Estudos Retrospectivos , Seguimentos , Implantação de Prótese , Condução Óssea , Audiometria de Tons Puros
4.
Eur Arch Otorhinolaryngol ; 281(1): 141-151, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37442819

RESUMO

PURPOSE: The Vibrant Soundbridge (VSB) is an established active-middle-ear-implant for patients with moderate-to-profound hearing-loss. This surgery is referred to as "Vibroplasty". Sufficient transfer of the VSB's floating-mass-transducers (FMT) energy to the inner ear is a crucial factor influencing the coupling-quality (CQ). However, assessing CQ is hamper by two issues: the method of CQ-assessment itself and the method of FMT-fixation during Vibroplasty. METHODS: This prospective study explored the influence of intraoperative auditory-brainstem-response (+ ABR) measurements and various fixation methods on postoperative CQ after Vibroplasty as compared to matched-patients after Vibroplasty without intraoperative ABR (-ABR). Propensity-score-matching was performed based on preoperative bone-conduction-pure-tone-average-3 (BC-PTA3) at 1-, 2- and 4 kHz. Primary outcome parameters were postoperative CQ-PTA3, intraoperative ABR threshold for various fixation methods and postoperative BC-PTA3. RESULTS: A total of 28 patients were included, of which 14 were + ABR. Preoperative BC-PTA3, sex, age, and number of previous surgeries did not differ significantly between groups (all p > 0.301). Mean postoperative CQ-PTA3 was significantly better for + ABR (1.8 vs. 12.3 dB-HL; p = 0.006). Mean intraoperative ABR threshold was superior for cartilage-counter-bearing and cartilage-housing compared to additional fixation with injectable-platelet-rich- fibrin (53 vs. 56 & 57 dB-HL, respectively; p = 0.04; η2 = 0.33). Mean postoperative BC-PTA3 did not significantly differ between patients (41.4 vs. 41.8 dB-HL; p = 0.77). A total of 7% of the patients required intraoperative readjustment of the FMT based on unsatisfactory intraoperative ABR threshold. CONCLUSION: Intraoperative ABR measurement resulted in significantly better postoperative CQ. Cartilage-counter-bearing and cartilage-housing were observed to have superior CQ. A total of 7% of the patients could be spared revision-Vibroplasty due to intraoperative ABR measurement.


Assuntos
Perda Auditiva Condutiva-Neurossensorial Mista , Prótese Ossicular , Humanos , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Estudos Prospectivos , Potenciais Evocados Auditivos do Tronco Encefálico , Limiar Auditivo/fisiologia , Resultado do Tratamento
5.
Eur Arch Otorhinolaryngol ; 281(1): 171-179, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37522908

RESUMO

OBJECTIVE: To analyze and compare the early and late post-operative results of glass ionomer bone cement (GIBC) used in ossiculoplasty. METHODS: The pre-operative, early post-operative (3 months) and late post-operative (> 2 years) audiometric findings, namely the pure-tone average (PTA), bone conduction threshold (BCT) and air-bone gap (ABG) of 40 patients who underwent GIBC ossiculoplasty for different etiologies were analyzed. Early and late results were compared. Also, the patients were grouped in terms of prognostic factors and applied ossiculoplasty techniques, and the results were compared between the groups. RESULTS: There were statistically significant improvements in the pure-tone average and air-bone gap of the patients in the early post-operative period (PTA from 59.60 ± 15.95 to 40.37 ± 17.83 and ABG from 37.12 ± 11.18 to 19.78 ± 10.41, p < 0.001 for both). There were no statistically significant changes in any of the audiometric parameters in the late post-operative period (PTA from 40.37 ± 17.83 to 39.79 ± 17.91, ABG from 19.78 ± 10.41 to 19.32 ± 9.60, BCT from 17.99 ± 12.71 to 18.31 ± 13.99, p > 0.05 for all). Presence of tympanosclerosis was found to be the only prognostic factor to affect the outcome. CONCLUSION: GIBC is a safe and reliable material for ossiculoplasty, which maintains its ability to conduct sound in the long-term follow-up.


Assuntos
Prótese Ossicular , Substituição Ossicular , Humanos , Resultado do Tratamento , Perda Auditiva Condutiva/etiologia , Perda Auditiva Condutiva/cirurgia , Audiometria de Tons Puros , Estudos Retrospectivos , Timpanoplastia/métodos , Substituição Ossicular/métodos
6.
Eur Arch Otorhinolaryngol ; 281(1): 129-139, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37603051

RESUMO

PURPOSE: The aim of this study was to evaluate the long-term effectiveness and acceptance of the active middle ear implant system Vibrant Soundbridge (VSB®, MED-EL, Austria) in patients with aural atresia or aplasia (children and adults). METHODS: Data from 51 patients (mean age 13.9 ± 11.3 years), 42 (79.2%) children and adolescents, and 11 (20.8%) adults) who received a VSB implant between 2009 and 2019 at the Department of Otolaryngology at LMU Clinic Großhadern, Munich were included in the study. Pure-tone audiometry, speech recognition in a quiet environment and in a noisy environment were performed preoperatively, during the first fitting of the audio processor, after 1-3 years, after 3-5 years, and after 5 years (if possible). The follow-up period ranged from 11 to 157 months with a mean of 58.6 months (4.8 years). Furthermore, the benefit of the VSB was evaluated by self-assessment questionnaires (Speech, Spatial, and Qualities of Hearing Scale, respectively, for parents). RESULTS: Significant improvements were observed in hearing and speech comprehension immediately after the initial fitting of the VSB system (mean hearing gain 38.4 ± 9.4 dB HL) and at follow-up intervals (1-3, 3-5 and after 5 years) for children and adults (p < 0.01). The values remained stable over the long-term, indicating a sustained functional gain from the VSB (mean hearing gain 38.9 ± 9.2 dB HL). The results of the self-assessments affirm the positive influence on hearing and speech comprehension with the VSB. With the VSB, there was an improvement of 41.3 ± 13.7% in the Freiburg monosyllable test. CONCLUSION: These results (a stable hearing gain over the long term, a good tolerance of the implant and an improvement in quality of life) affirm the recommendation for using the active middle ear implant VSB as early as permitted for aural atresia and aplasia patients. This study represents the audiometric results with the (to date) largest collective of aural atresia patients and with a long follow-up period.


Assuntos
Auxiliares de Audição , Prótese Ossicular , Adulto , Criança , Adolescente , Humanos , Pré-Escolar , Adulto Jovem , Qualidade de Vida , Resultado do Tratamento , Orelha/anormalidades , Audiometria de Tons Puros , Perda Auditiva Condutiva/cirurgia
7.
Eur Arch Otorhinolaryngol ; 281(7): 3569-3575, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38324057

RESUMO

PURPOSE: The aim of the presented study was to compare the audiological benefit achieved in cochlear implant (CI) patients who, in principle, could still have been treated with an active middle ear implant (AMEI) with a group of AMEI users. METHODS: Results of 20 CI patients with a pure-tone average (PTA) of 70 dB HL prior to surgery were compared with a group of 12 subjects treated with a Vibrant Soundbridge (VSB). Pre-surgical comparison included PTA for air conduction and bone conduction, maximum speech recognition score for monosyllabic words (WRSmax), and aided monosyllabic word recognition at 65 dB SPL. One year after surgery, aided monosyllabic speech recognition score at 65 dB SPL was compared. RESULTS: Mean PTA for air conduction in the VSB group was significantly lower than in the CI group (4.8 dB, Z = - 2.011, p < 0.05). Mean PTA for bone conduction in the VSB group was also significantly lower than in the CI group (23.4 dB, Z = - 4.673, p < 0.001). WRSmax in the VSB group was significantly better than in the CI group (40.7%, Z = - 3.705, p < 0.001). One year after treatment, there was no significant difference in aided speech perception in quiet between both subject groups. CONCLUSION: Comparison of the two methods showed equivalent results for both treatments in subjects with a borderline indication. Not only pure-tone audiometry results but, particularly, speech perception scores pre-surgery should be taken into account in preoperative counseling.


Assuntos
Audiometria de Tons Puros , Implantes Cocleares , Percepção da Fala , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Adulto , Percepção da Fala/fisiologia , Idoso , Prótese Ossicular , Condução Óssea/fisiologia , Resultado do Tratamento , Aconselhamento , Implante Coclear/métodos , Cuidados Pré-Operatórios/métodos , Tomada de Decisão Clínica
8.
Eur Arch Otorhinolaryngol ; 281(2): 711-718, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37542562

RESUMO

PURPOSE: In primary cholesteatoma patients, incus destruction with an intact and mobile stapes is a frequent finding. Different techniques have been described to restore the ossicular chain, including incus interposition, stapes augmentation and type III tympanoplasty. Controversy about postoperative hearing results in open versus closed surgical techniques exist. METHODS: We performed a retrospective analysis of clinical, surgical and audiometric data of patients with primary cholesteatoma surgery operated between 2010 and 2020, and a mobile stapes and one-stage ossicular reconstruction. Pre- and post-operative audiograms were compared for the different surgical groups, mainly focusing on postoperative air-bone gap. Mastoid pneumatization and ventilation was also considered. RESULTS: The mean postoperative air-bone gap (0.5-4 kHz) of the 126 included patients was 20 dB. Hearing after type III tympanoplasty (26 dB) was worse than incus interposition (19 dB) and stapes augmentation (20 dB). Hearing after an open (23 dB) versus closed (19 dB) surgical technique was significantly different. No improvement in air-bone gap was observed for the higher frequencies. CONCLUSION: A residual postoperative air-bone gap should be considered after primary cholesteatoma surgery with intact and mobile stapes. Incus interposition in closed cavity operation is the optimal situation, but open cavity surgery should not be avoided because of hearing. Extent of the disease is prioritized and poorer ventilation before and after surgery may affect postoperative hearing.


Assuntos
Colesteatoma da Orelha Média , Prótese Ossicular , Substituição Ossicular , Humanos , Estribo , Timpanoplastia/métodos , Bigorna/cirurgia , Estudos Retrospectivos , Colesteatoma da Orelha Média/complicações , Colesteatoma da Orelha Média/cirurgia , Resultado do Tratamento , Substituição Ossicular/métodos
9.
Eur Arch Otorhinolaryngol ; 281(6): 2931-2939, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38273045

RESUMO

PURPOSE: To evaluate the effect of piston diameter in patients undergoing primary stapes surgery on audiometric results and postoperative complications. METHODS: A retrospective single-center cohort study was performed. Adult patients who underwent primary stapes surgery between January 2013 and April 2022 and received a 0.4-mm-diameter piston or a 0.6-mm-diameter piston were included. The primary and secondary outcomes were pre- and postoperative pure-tone audiometry, pre- and postoperative speech audiometry, postoperative complications, intraoperative anatomical difficulties, and the need for revision stapes surgery. The pure-tone audiometry included air conduction, bone conduction, and air-bone gap averaged over 0.5, 1, 2 and 3 kHz. RESULTS: In total, 280 otosclerosis patients who underwent 321 primary stapes surgeries were included. The audiometric outcomes were significantly better in the 0.6 mm group compared to the 0.4 mm group in terms of gain in air conduction (median = 24 and 20 dB, respectively), postoperative air-bone gap (median = 7.5 and 9.4 dB, respectively), gain in air-bone gap (median = 20.0 and 18.1 dB, respectively), air-bone gap closure to 10 dB or less (75% and 59%, respectively) and 100% speech reception (median = 75 and 80 dB, respectively). We found no statistically significant difference in postoperative dizziness, postoperative complications and the need for revision stapes surgery between the 0.4 and 0.6 mm group. The incidence of anatomical difficulties was higher in the 0.4 mm group. CONCLUSION: The use of a 0.6-mm-diameter piston during stapes surgery seems to provide better audiometric results compared to a 0.4-mm-diameter piston, and should be the preferred piston size in otosclerosis surgery. We found no statistically significant difference in postoperative complications between the 0.4- and 0.6-mm-diameter piston. Based on the results, we recommend always using a 0.6-mm-diameter piston during primary stapes surgery unless anatomical difficulties do not allow it.


Assuntos
Audiometria de Tons Puros , Condução Óssea , Otosclerose , Complicações Pós-Operatórias , Cirurgia do Estribo , Humanos , Cirurgia do Estribo/métodos , Estudos Retrospectivos , Masculino , Otosclerose/cirurgia , Feminino , Pessoa de Meia-Idade , Adulto , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento , Prótese Ossicular , Idoso , Desenho de Prótese , Reoperação , Audiometria da Fala
10.
BMC Med Educ ; 24(1): 451, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658934

RESUMO

BACKGROUND: In otosurgical training, cadaveric temporal bones are primarily used to provide a realistic tactile experience. However, using cadaveric temporal bones is challenging due to their limited availability, high cost, and potential for infection. Utilizing current three-dimensional (3D) technologies could overcome the limitations associated with cadaveric bones. This study focused on how a 3D-printed middle ear model can be used in otosurgical training. METHODS: A cadaveric temporal bone was imaged using microcomputed tomography (micro-CT) to generate a 3D model of the middle ear. The final model was printed from transparent photopolymers using a laser-based 3D printer (vat photopolymerization), yielding a 3D-printed phantom of the external ear canal and middle ear. The feasibility of this phantom for otosurgical training was evaluated through an ossiculoplasty simulation involving ten otosurgeons and ten otolaryngology-head and neck surgery (ORL-HNS) residents. The participants were tasked with drilling, scooping, and placing a 3D-printed partial ossicular replacement prosthesis (PORP). Following the simulation, a questionnaire was used to collect the participants' opinions and feedback. RESULTS: A transparent photopolymer was deemed suitable for both the middle ear phantom and PORP. The printing procedure was precise, and the anatomical landmarks were recognizable. Based on the evaluations, the phantom had realistic maneuverability, although the haptic feedback during drilling and scooping received some criticism from ORL-HNS residents. Both otosurgeons and ORL-HNS residents were optimistic about the application of these 3D-printed models as training tools. CONCLUSIONS: The 3D-printed middle ear phantom and PORP used in this study can be used for low-threshold training in the future. The integration of 3D-printed models in conventional otosurgical training holds significant promise.


Assuntos
Cadáver , Orelha Média , Modelos Anatômicos , Impressão Tridimensional , Osso Temporal , Humanos , Orelha Média/cirurgia , Osso Temporal/cirurgia , Osso Temporal/diagnóstico por imagem , Prótese Ossicular , Otolaringologia/educação , Microtomografia por Raio-X , Treinamento por Simulação , Procedimentos Cirúrgicos Otológicos/educação , Procedimentos Cirúrgicos Otológicos/instrumentação , Internato e Residência
11.
ORL J Otorhinolaryngol Relat Spec ; 86(2): 101-106, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38432225

RESUMO

INTRODUCTION: Congenital ossicular chain anomalies are rare conductive hearing loss conditions that remain difficult to diagnose even with high-resolution computed tomography (CT). The preoperative diagnosis is helpful for surgical planning and counseling patients regarding treatment outcomes. CASE PRESENTATION: We report a case involving a 14-year-old boy presenting with left conductive hearing loss without history of trauma for 5 years, physical examination showed normal otoscopic examination bilaterally and high-resolution CT showed absent of stapes suprastructure and footplate. Subsequent diagnosis was done via endoscopic middle ear exploration which revealed an absent long process of the incus, stapes suprastructure and footplate, but with intact oval window membrane. The residual incus was removed, and a tragal perichondrium graft was used over the oval window. A total ossicular replacement prosthesis was placed between the malleus and oval window to repair the chain. Postoperatively, the patient had no complications. Preoperative pure tone average revealed an air/bone result of 52/8 dB. Follow-up after surgery at 6 months showed a pure tone average air/bone result of 15/3 dB. The air-bone gap was reduced from 44 to 12 dB. CONCLUSION: Congenital absence of the stapes suprastructure and footplate remains a rare condition compared to the myriad of middle ear anomalies in the literature.


Assuntos
Perda Auditiva Condutiva , Substituição Ossicular , Estribo , Tomografia Computadorizada por Raios X , Humanos , Masculino , Adolescente , Perda Auditiva Condutiva/cirurgia , Perda Auditiva Condutiva/etiologia , Estribo/anormalidades , Estribo/diagnóstico por imagem , Substituição Ossicular/métodos , Prótese Ossicular , Audiometria de Tons Puros
12.
Audiol Neurootol ; 28(3): 211-218, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36634639

RESUMO

INTRODUCTION: The amount of listening effort needed to understand speech in every-day life is an important outcome measure of the effectiveness of a hearing device. The main goal of this study was to assess subjective listening effort in patients implanted with an active middle ear implant Vibrant Soundbridge (VSB) with and without using their speech processor in complex acoustic scenarios. METHODS: Ten VSB users were measured using the adaptive categorical listening effort scaling (ACALES) method in four different acoustic scenarios, realized using a multichannel loudspeaker array. The four acoustic scenarios included both spatially simple and complex speech and noise arrangements that realistically simulated challenging every-day listening situations. Signal-to-noise ratios (SNRs) were adaptively varied during the measurement. Twelve normal-hearing (NH) listeners performed the same experiment as a control group. RESULTS: Listening effort was significantly reduced in all tested acoustic scenarios when participants used their VSB. When using the VSB, SNRs corresponding to mild-to-moderate listening effort were found not to be statistically different from SNRs found in the NH control group. SNRs corresponding to extreme listening effort of VSB users approached NH values, indicating partial restoration of listening effort. DISCUSSION AND CONCLUSIONS: Usage of the middle ear implant VSB was found to restore subjective listening effort to normal at high SNRs completely, and at lower SNRs partially. The remaining gap at low SNRs may be due to lower effectiveness of signal processing at high noise levels or due to the microphone location effect.


Assuntos
Prótese Ossicular , Percepção da Fala , Humanos , Esforço de Escuta , Ruído , Percepção Auditiva , Acústica
13.
Ear Hear ; 44(1): 135-145, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35913925

RESUMO

OBJECTIVES: The active middle ear implant, Vibrant Soundbridge (VSB), can be implanted with a variety of couplers. Hearing outcome after implantation has been investigated in both temporal bone (TB) experiments and patient studies, but the relationship between experimental and clinical data is still weak in the literature. Therefore, experimental data from TB experiments should be compared with patient data in a retrospective study, in which the floating mass transducer is used with couplers of the third generation. Actuator coupling structures included the long (LP coupler) and short (SP coupler) incus process, the stapes head (Clip coupler), and the round window membrane (RW soft coupler). METHODS: In the TB experiments, the sound transmission after vibroplasty on the above-mentioned actuator coupling structures was determined in 32 specimens by means of laser Doppler vibrometry on the stapes footplate. Data of 69 patients were analyzed. The main target audiometric parameters were the postoperative aided word recognition score (WRS) in the free field at 65 dB SPL (WRS 65 dB in %), the preoperative and postoperative pure-tone average (PTA4, including the frequencies 0.5, 1, 2, and 4 kHz) of the bone conduction hearing threshold (PTA4BC), the aided postoperative air conduction hearing threshold in the free field (PTA4FF) and the direct threshold (Vibrogram) at least 6 months postoperatively. The coupling efficiency of the actuator (Vibrogram-PTA4BC) as well as the effective hearing gain (PTA4FF-PTA4BC) was compared between the couplers. RESULTS: The analysis in the main speech range (0.5-4 kHz) indicated that in the TB experiments, the LP coupler tends to have the best coupling quality at low frequencies (500-1000 Hz). This was up to 15 dB above the worst actuator (RW soft coupler). However, the results missed the significance level ( p > 0.05). In the high frequencies (2000-4000 Hz), the Clip coupler showed the best coupling quality. This was 15 dB above the worst actuator (SP coupler). However, the results missed the significance level ( p > 0.05), too. The postoperative WRS at 65 dB SPL and the postoperative PTA4FF were independent of the actuator coupling structure. The PTA4BC was stable at 6 months postoperatively. For the PTA4 of the coupling efficiency, there were no significant differences between the actuator coupling structures (LP 8.9 dB ± 12.9; SP 9.5 ± 6.5 dB; Clip 5.2 ± 10.5 dB; RW 12.7 ± 11.0 dB). However, the tendential inferiority of the RW soft coupler with regard to transmission in the low-frequency range and the tendential superiority of the Clip coupler in the high-frequency range that have already been displayed experimentally could be confirmed in the clinical results. However, the clinical results missed the significance level, too ( p > 0.05). CONCLUSIONS: In vivo, there are no significant differences in the postoperative outcome stratified according to coupling the target structure. The differences known from the experimental setting were repressed by individual biasing factors. However, to ensure sufficient postoperative speech intelligibility, the frequency-specific transmission behavior of the couplers should be taken into account when setting the indication for VSB implantation.


Assuntos
Perda Auditiva Condutiva-Neurossensorial Mista , Prótese Ossicular , Humanos , Estudos Retrospectivos , Audição , Osso Temporal/cirurgia , Resultado do Tratamento
14.
Med Sci Monit ; 29: e940337, 2023 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-37480226

RESUMO

BACKGROUND We explored a new method for measuring the length of artificial stapes during stapedotomy in otoendoscopic middle-ear surgery using a flexible ruler. MATERIAL AND METHODS A retrospective analysis was conducted on 56 cases of otosclerosis, comprising 56 ears with a follow-up of over 6 months and complete data. Patients were admitted to the Department of Otology, Huazhong University of Science and Technology Union Shenzhen Hospital from July 2020 to June 2022. SPSS statistical software was used for efficacy analysis. The results of different measurement methods on the implantation time of the prosthesis and postoperative hearing follow-up were compared. RESULTS The 56 patients were randomly divided into 2 groups. In 1 case measured by the metal measuring stick, the prosthesis was too short and was replaced during the operation; 2 patients experienced transient dizziness postoperatively, and the other patients had no surgical complications. All 56 patients had varying degrees of hearing improvement after surgery, and no dislocation of the ossicular chain was observed during the follow-up. There was a statistically significant difference in the implantation time of the prosthesis between the different measurement methods (P<0.05). The improvement in hearing in the flexible ruler group was statistically significant (P<0.05). CONCLUSIONS The selection of the length of the ossicular prosthesis is a crucial step in the operation and can directly affect hearing outcomes. The use of a flexible ruler to measure prosthesis length can significantly shorten operation time and improve hearing, and the ruler is easily obtainable. It is worth promoting its application in ear endoscopic stapedotomy.


Assuntos
Membros Artificiais , Prótese Ossicular , Humanos , Estribo , Estudos Retrospectivos , Implantação de Prótese
15.
Am J Otolaryngol ; 44(6): 103969, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37437334

RESUMO

OBJECTIVES: Sometimes performing PORP adequately is challenging when the stapes is tilted or the suprastructure is partially damaged owing to inflammation or infection. In such cases, the implementation of a TORP bypassing the stapes can be a useful alternative. This study aimed to investigate whether bypassing the stapes suprastructure during total ossicular replacement prosthesis (TORP) affects postoperative complications or audiological outcomes. MATERIAL AND METHODS: Among 104 patients who underwent open cavity mastoidectomy and ossiculoplasty using a titanium prosthesis at Korea University Ansan Hospital between January 2012 and December 2019, we compared the preoperative and postoperative audiological results and surgical complications of 52, 21, and 31 patients who underwent partial ossicular replacement prosthesis (PORP), TORP bypassing the remaining stapes suprastructure, and TORP on the stapes footplate or oval window, respectively. RESULTS: The air-bone gap before surgery was significantly different in the TORP on the stapes footplate group (34.2 ± 12.0 dB) than that in the PORP (22.9 ± 13.8 dB) and TORP bypassing the stapes groups (20.7 ± 11.5 dB, p < 0.001). After surgery, there were no significant differences among the groups (p = 0.818). The air-bone gap difference before surgery was associated with the presence of stapes before surgery (p < 0.001). There was no difference in the proportion of postoperative tympanic perforation, whether it was a revision surgery, malleus status, or the size of perforation of the tympanic membrane among the three groups. CONCLUSION: When performing ossiculoplasty using TORP, bypassing the stapes did not affect surgical and audiologic outcomes.


Assuntos
Prótese Ossicular , Substituição Ossicular , Humanos , Estribo , Substituição Ossicular/métodos , Mastoidectomia , Resultado do Tratamento , Estudos Retrospectivos
16.
Am J Otolaryngol ; 44(1): 103658, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36347062

RESUMO

OBJECTIVES: To compare the mean pre-operative air-bone gaps (ABG), mean post-operative ABGs, and extrusion rates between pediatric recipients of partial ossicular reconstruction prostheses (PORPs) and pediatric recipients of total ossicular reconstruction prostheses (TORPs) via a systematic review and meta-analysis. METHODS: A quantitative systematic review last updated on September 29, 2021 of PubMed, Scopus, and Embase databases was conducted for studies reporting mean post-operative ABGs or numbers of children with post-operative ABG ≤ 20 dB following PORP and TORP procedures in at least five children aged 0-18 years. Studies were excluded if they were review articles, conference abstracts, or not in English. Studies that primarily reported data on congenital aural atresia, stapedectomy/stapedotomy, congenital stapes fixation, or juvenile otosclerosis were also excluded. NIH Quality Assessment Tool for Observational Cohort and Cross-Sectional Studies was used to assess for risk of bias. Review Manager (RevMan) version 5.4.1 was used to perform the meta-analysis and generate forest plots. RESULTS: Out of 648 unique abstracts retrieved, 11 papers were included in this systematic review with meta-analysis. Data from 449 children (247 TORP recipients and 202 TORP recipients) are represented among the various analyses. Data from nine studies, representing 84.2 % of all children in the systematic review, demonstrated that PORP recipients presented with a pre-operative ABG 6.30 dB less than TORP recipients (mean difference: -6.30, 95 %CI: -7.4, -5.18, p < 0.01). Data from these same children demonstrated that PORP recipients had a 1.80 dB less post-operative ABG compared to TORP recipients (mean difference: -1.80 dB, 95 %CI: -2.84, -0.77, p < 0.001). Data from seven studies, representing 49.4 % of all children in the systematic review, demonstrated that PORP recipients were more likely to have a successful closure of the post-operative ABG to ≤20 dB (OR: 2.12, 95 %CI: 1.18, 3.79, p = 0.01). In these same children, 62.5 % of PORP recipients had a post-operative ABG ≤ 20 dB and 48.3 % of TORP recipients had a post-operative ABG ≤ 20 dB. There was no difference in extrusion rates between PORP recipients compared to TORP recipients (OR: 1.08, 95 %CI: 0.31, 3.78, p = 0.90) from five studies representing 45.9 % children in the systematic review. CONCLUSION: Children who receive a PORP have better pre-operative hearing baselines and post-operative hearing outcomes compared to those who receive TORP with similar rates of extrusion. More pediatric studies should report their mean pre- and post-operative ABGs stratifying by various material types, surgical indications, and surgical details to facilitate future meta-analyses.


Assuntos
Prótese Ossicular , Substituição Ossicular , Cirurgia do Estribo , Criança , Humanos , Substituição Ossicular/métodos , Estudos Transversais , Resultado do Tratamento , Estudos Retrospectivos
17.
Am J Otolaryngol ; 44(5): 103928, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37245325

RESUMO

OBJECTIVE: Investigation of ossicular chain (OC) status before surgery is important for preoperative patient consultation. This research aimed to investigate the relationship between pre-operative audiometric values and intra-operative OC condition in a relatively large population of chronic otitis media (COM) surgeries. METHODS: In this descriptive-analytic cross-sectional study, we evaluated 694 patients who underwent COM surgeries. We analyzed pre-operative audiometric data and intraoperative findings including ossicular anatomy, ossicular mobility, and the condition of middle ear mucosa. RESULTS: The optimal cut-off values of pre-operative speech reception threshold (SRT), mean air-conduction (AC), and mean air-bone gap (ABG) for predicting OC discontinuity were 37.5 dB, 37.2 dB, and 28.4 dB, respectively. For the prediction of OC fixation, the optimal cut-off points of SRT, mean AC, and mean ABG were 37.5 dB, 40.3 dB, and 32.8 dB, respectively. The computing of Cohen's d (95 % confidence interval) demonstrated the greater mean ABG in ears with OC discontinuity in comparison with ears with normal ossicles in all types of pathologies. There was a descending trend of Cohen's d from cholesteatoma to tympanosclerosis and then to granulation tissue and hypertrophic mucosa. There was a substantial relation between the type of pathology and OC status (P < 0.001). Ears with tympanosclerosis plaque had the most fixed OC among all types of pathologies (40 ears, 30.8 %), and ears with no pathology had the most normal OC (135 ears, 83.3 %). CONCLUSIONS: The results supported the view that pre-operative hearing is a key determining factor for the prediction of OC status.


Assuntos
Colesteatoma da Orelha Média , Prótese Ossicular , Otite Média , Humanos , Estudos Transversais , Audiometria de Tons Puros , Condução Óssea , Ossículos da Orelha/cirurgia , Otite Média/diagnóstico , Otite Média/cirurgia , Otite Média/patologia , Colesteatoma da Orelha Média/diagnóstico , Colesteatoma da Orelha Média/cirurgia , Colesteatoma da Orelha Média/patologia , Doença Crônica , Estudos Retrospectivos , Resultado do Tratamento
18.
Eur Arch Otorhinolaryngol ; 280(5): 2387-2396, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36441245

RESUMO

INTRODUCTION: The Vibrant Soundbridge (VSB) is a semi-implantable hearing aid for patients with various types of hearing loss and has been available for over 25 years. Recently, new audio processors with advanced signal processing, noise reduction, and multi-microphone technology have appeared. The aim of this study is to compare the benefits of using the newest Samba 2 processor to the previous generation processors in a group of experienced VSB users. METHODS: There were 22 experienced VSB users (mean time of using VSB was 9 years, SD = 2) who had their processor (D404 or Amadé) upgraded to the newest model (Samba 2). The mean age of the subjects was 56 years (SD = 20). Assessments were made by free-field audiometry, speech reception in quiet and noise, and Patient-Reported Outcome Measures (PROMs). RESULTS: Hearing tests in free field showed statistically significant improvements in hearing sensitivity and speech discrimination in quiet and noise with the Samba 2 audio processor compared to the earlier technology. PROMs confirmed the benefits of using the newest audio processor and there was more satisfaction in terms of usability. CONCLUSIONS: Access to modern technology for VSB patients provides measurable benefits.


Assuntos
Auxiliares de Audição , Perda Auditiva , Prótese Ossicular , Percepção da Fala , Humanos , Pessoa de Meia-Idade , Audição , Audiometria , Ruído
19.
Eur Arch Otorhinolaryngol ; 280(10): 4381-4389, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37000276

RESUMO

PURPOSE: Due to smaller bone thickness, young children with conductive or mixed hearing loss or single-sided deafness were previously most commonly treated with a percutaneous osseointegrated bone-anchored hearing aid (BAHA) or an active middle-ear implant. While the BAHA increases the risk of implant infections, skin infection, overgrowth of the screw or involvement of the implant in head trauma, middle-ear implant surgery involves manipulation of the ossicles with possible risk of surgical trauma. These complications can be omitted with transcutaneous bone conduction implant systems like the MED-EL Bonebridge system. The purpose of this study was to analyze whether the second generation of the Bonebridge (BCI 602) that features a decreased implant thickness with a reduced surgical drilling depth can be implanted safely in young children with good postoperative hearing performance. METHODS: In this study, 14 patients under 12 years were implanted with the second generation of the Bonebridge. Preoperative workup comprised a CT scan, an MRI scan, pure tone audiometry, or alternatively a BERA (bone conduction, air conduction). Since children under 12 years often have a lower bone thickness, the CT was performed to determine the suitability of the temporal bone for optimal implant placement using the Otoplan software. RESULTS: All patients (including three under the age of five) were successfully implanted and showed a good postoperative hearing performance. CONCLUSION: With adequate preoperative workup, this device can be safely implanted in children and even children under 5 years of age and allows for an extension of indication criteria toward younger children.


Assuntos
Auxiliares de Audição , Perda Auditiva Condutiva-Neurossensorial Mista , Prótese Ossicular , Humanos , Criança , Pré-Escolar , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Perda Auditiva Condutiva-Neurossensorial Mista/reabilitação , Condução Óssea , Audiometria de Tons Puros
20.
Eur Arch Otorhinolaryngol ; 280(8): 3567-3575, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36715736

RESUMO

PURPOSE: Comparison of the hearing outcomes of titanium partial ossicular replacement prosthesis (PORP) vs. titanium total ossicular replacement prosthesis (TORP) with footplate shoe (Omega Connector) in second stage ossicular chain reconstruction surgeries. METHODS: In this retrospective cohort study in a tertiary hospital, we compared the hearing outcomes in 248 patients who had undergone ossicular chain reconstruction with titanium prostheses PORP (n = 115) vs. TORP (n = 133) from August 2017 to June 2021. Pre-and post-operative audiometric data were assessed. RESULTS: In general, we found that there were no significant differences between PORP and TORP groups in gains of BC (P = 0.080), AC (P = 0.454), ABG (P = 0.928), SRT (P = 0.065), and SDS (P = 0.363). There were no significant differences in terms of ABG gain between the two groups. Regarding ABG gains frequency-specific analysis in the ears with pre-operative conductive hearing loss, there were no significant differences between low-frequencies (P = 0.260) and high-frequencies (P = 0.973) between the two groups. CONCLUSION: To sum up, this research provided additional evidence with respect to hearing outcomes after staged ossicular chain reconstruction with PORP and TORP. The practical application of our study is that TORP with footplate shoe (Omega Connector) is comparable with PORP in staged ossiculoplasty.


Assuntos
Prótese Ossicular , Substituição Ossicular , Humanos , Substituição Ossicular/métodos , Titânio , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS