Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.212
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Nucl Cardiol ; 36: 101867, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38697386

RESUMO

BACKGROUND: The segment of the latest mechanical contraction (LMC) does not always overlap with the site of the latest electrical activation (LEA). By integrating both mechanical and electrical dyssynchrony, this proof-of-concept study aimed to propose a new method for recommending left ventricular (LV) lead placements, with the goal of enhancing response to cardiac resynchronization therapy (CRT). METHODS: The LMC segment was determined by single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) phase analysis. The LEA site was detected by vectorcardiogram. The recommended segments for LV lead placement were as follows: (1) the LMC viable segments that overlapped with the LEA site; (2) the LMC viable segments adjacent to the LEA site; (3) If no segment met either of the above, the LV lateral wall was recommended. The response was defined as ≥15% reduction in left ventricular end-systolic volume (LVESV) 6-months after CRT. Patients with LV lead located in the recommended site were assigned to the recommended group, and those located in the non-recommended site were assigned to the non-recommended group. RESULTS: The cohort comprised of 76 patients, including 54 (71.1%) in the recommended group and 22 (28.9%) in the non-recommended group. Among the recommended group, 74.1% of the patients responded to CRT, while 36.4% in the non-recommended group were responders (P = .002). Compared to pacing at the non-recommended segments, pacing at the recommended segments showed an independent association with an increased response by univariate and multivariable analysis (odds ratio 5.00, 95% confidence interval 1.73-14.44, P = .003; odds ratio 7.33, 95% confidence interval 1.53-35.14, P = .013). Kaplan-Meier curves showed that pacing at the recommended LV lead position demonstrated a better long-term prognosis. CONCLUSION: Our findings indicate that pacing at the recommended segments, by integrating of mechanical and electrical dyssynchrony, is significantly associated with an improved CRT response and better long-term prognosis.


Assuntos
Terapia de Ressincronização Cardíaca , Ventrículos do Coração , Vetorcardiografia , Humanos , Terapia de Ressincronização Cardíaca/métodos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Vetorcardiografia/métodos , Resultado do Tratamento , Ventrículos do Coração/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Imagem de Perfusão do Miocárdio/métodos , Estudo de Prova de Conceito , Tomografia Computadorizada de Emissão de Fóton Único , Dispositivos de Terapia de Ressincronização Cardíaca
2.
Pacing Clin Electrophysiol ; 47(7): 974-976, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38529807

RESUMO

3DQRSarea is a strong marker for cardiac resynchronization therapy and can be obtained by taking the (i) summation or the (ii) difference of the areas subtended by positive and negative deflections in X, Y, Z vectorcardiographic electrocardiogram (ECG) leads. We correlated both methods with the instantaneous-absolute-3D-voltage-time-integral (VTIQRS-3D). 3DQRSarea consistently underestimated the VTIQRS -3D, but the summation method was a closer and more reliable approximation. The dissimilarity was less apparent in left bundle branch block (r2 summation .996 vs. difference .972) and biventricular paced ECGs (r2 .996 vs. .957) but was more apparent in normal ECGs (r2 .988 vs. .653).


Assuntos
Vetorcardiografia , Humanos , Vetorcardiografia/métodos , Terapia de Ressincronização Cardíaca/métodos , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Masculino , Eletrocardiografia/métodos , Reprodutibilidade dos Testes , Feminino , Sensibilidade e Especificidade , Diagnóstico por Computador/métodos , Algoritmos
3.
J Electrocardiol ; 84: 81-87, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38574634

RESUMO

BACKGROUND: Precordial Bipolar Leads (PBLs) provide new electrocardiographic information derived from standard 12­lead ECG recordings. OBJECTIVES: To explore the usefulness of PBLs in patients with acute circumflex coronary artery (CxCA) occlusion. METHODS: Twelve patients undergoing elective percutaneous transluminal coronary angioplasty (PTCA) were studied before and after acute CxCA occlusion and their data were processed with new methods based on PBLs. RESULTS: The findings were: 1. In right PBL V2-V1, a strong systolic current of injury moving in the left-to-right direction coexists with a strong right-to-left current of injury displayed in left standard unipolar precordial leads (V4, V5 and V6). 2. Ischemic changes lead to a significant increase (approximately 10 ms) in the QRS duration in different leads, although changes in the QRS loop rotation and folding were absent. 3. In the transverse, sagittal, and frontal planes, superimposing two PBLs and the corresponding Regional VCG facilitates the location of the J-point. 4. In the Regional VCGs of this group of patients, J-point and ST segment shifts produced an image that reminds the Greek letter omega (Ω). 5. The currents of injury flowing in opposite directions could result in electrical cancellation that minimizes ECG changes in the standard 12­lead recordings. CONCLUSIONS: Computerized processing of digital, standard 12­lead ECG recordings, provides new valuable diagnostic data in patients with acute CxCA occlusion. The loops revealed important information related to systolic currents of injury. Because these methods use routine 12­lead ECG data, the procedure is based only in software applications. CONDENSED ABSTRACT: Twelve patients undergoing PTCA were studied before and after acute CxCA occlusion and their data were processed with the new methods based on Precordial Bipolar Leads (PBLs) to explore their usefulness. The results showed strong systolic currents of injury in different and sometimes opposite directions in the right-to-left axis and ischemic alterations in the time and amplitude of the QRS waves. The superimposition of two-dimensional coordinates planes (x-y, x-z or z-y) helped to locate the J-point and to display the Regional VCG omega sign (Ω) of myocardial injury. In conclusion, computerized processing of digital ECG data provides new diagnostic information in patients with acute CxCA occlusion.


Assuntos
Vetorcardiografia , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Vetorcardiografia/métodos , Reprodutibilidade dos Testes , Idoso , Sensibilidade e Especificidade , Ventrículos do Coração/fisiopatologia , Eletrodos , Eletrocardiografia , Diagnóstico por Computador/métodos
4.
J Electrocardiol ; 85: 78-86, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38876821

RESUMO

BACKGROUND: Limited data exists on interpreting vectorcardiography (VCG) parameters in the Fontan population. OBJECTIVE: The purpose of this study was to demonstrate the associations between ECG/VCG parameters and Fontan failure (FF). METHODS/RESULTS: 107 patients with a Fontan operation after 1990 and without significant ventricular pacing were included. FF and Fontan survival (FS) groups were compared. The average follow-up after Fontan operation was 11.8 years ±7.1 years. 14 patients had FF (13.1%) which was defined as having protein-losing-enteropathy (1.9%), plastic bronchitis (2.8%), Fontan takedown (1.9%), heart transplant (5.6%), NYHA class III-IV (2.8%) or death (0.9%). A 12­lead ECG at last follow up or prior to FF was assessed for heart rate, PR interval, QRS duration, Qtc and left/right sided precordial measures (P-wave, QRS and T-wave vector magnitudes, spatial P-R and QRS-T angles). Transthoracic echocardiogram evaluated atrioventricular valve regurgitation and ventricular dysfunction at FF or last follow up. A cox multivariate regression analysis adjusted for LV dominance, ventricular dysfunction, HR, PR, QTc, Pvm, QRSvm, SPQRST-angle, RtPvm, RtQRSvm and RtTvm. Ventricular dysfunction, increased heart rate and prolonged PR interval were significantly associated to FF at the multivariate analysis. ROC analysis and Kaplan-meier analysis revealed an increased total mortality associated with a heart rate > 93 bpm, PR interval > 155 mv, QRSvm >1.91 mV, RtQRSvm >1.8 mV and SPQRST angle >92.3 mV with p values <0.001 to 0.018. CONCLUSION: We demonstrate the importance of ECG/VCG monitoring in the Fontan population and suggest specific indicators of late complications and mortality.


Assuntos
Técnica de Fontan , Frequência Cardíaca , Vetorcardiografia , Humanos , Masculino , Feminino , Vetorcardiografia/métodos , Criança , Eletrocardiografia , Taxa de Sobrevida , Sensibilidade e Especificidade , Falha de Tratamento , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/mortalidade , Adolescente
5.
J Electrocardiol ; 82: 100-112, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38113771

RESUMO

BACKGROUND: The vectocardiogram (VCG) offers a three-dimensional view of the heart's electrical activity, yet many VCG parameters remain unexplored in diverse clinical contexts. OBJECTIVES: This study aims to explore the relationships between various VCG parameters and specific patient characteristics. METHODS: ECG signals from adults were transformed into VCGs utilizing the Kors matrix, yielding 315 parameters per patient from the P, QRS and T loops. Univariable analysis, circular statistics, and stepwise logistic regression were employed to examine the relationships between VCG parameters and factors such as age, sex, BMI, hypertension, echocardiographic ischemic heart disease (Echo-IHD), and left ventricular hypertrophy (Echo-LVH). RESULTS: We included 664 adults and considered an alpha value of 0.05 and a power of 90%. The study revealed significant associations, such as age with P loop roundness index (RI) (OR = 3.825, 95% confidence interval [95%CI] = 2.079-7.04), male sex with QRS loop RI (OR = 6.08, 95%CI = 1.835-20.153), abnormal BMI with the T loop's RI (OR = 0.544, 95%CI = 0.325-0.909), hypertension with the T loop planarity index (PI) (OR = 8.01, 95%CI = 2.134-30.117), Echo-IHD with QRS loop curvature at the 4/10th segment (OR = 7.58, 95%CI = 1.954-29.458), and Echo-LVH with the T loop lag-1/10 dihedral angle (OR = 10.3, 95%CI = 1.822-58.101). In the study, several additional VCG parameters demonstrated statistically significant, albeit smaller, associations with patient demographics and cardiovascular conditions. CONCLUSIONS: The findings enhance our understanding of the intricate relationships between VCG parameters and patient characteristics, emphasizing the potential role of VCG analysis in assessing cardiovascular diseases. These insights may guide future research and clinical applications in cardiology.


Assuntos
Doenças Cardiovasculares , Cardiopatias , Hipertensão , Isquemia Miocárdica , Adulto , Masculino , Humanos , Eletrocardiografia/métodos , Índice de Massa Corporal , Vetorcardiografia/métodos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem
6.
Am J Physiol Heart Circ Physiol ; 325(6): H1279-H1289, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37773058

RESUMO

Congenital long QT syndrome (LQTS) carries an increased risk for syncope and sudden death. QT prolongation promotes ventricular extrasystoles, which, in the presence of an arrhythmia substrate, might trigger ventricular tachycardia degenerating into fibrillation. Increased electrical heterogeneity (dispersion) is the suggested arrhythmia substrate in LQTS. In the most common subtype LQT1, physical exercise predisposes for arrhythmia and spatiotemporal dispersion was therefore studied in this context. Thirty-seven patients (57% on ß-blockers) and 37 healthy controls (mean age, 31 vs. 35; range, 6-68 vs. 6-72 yr) performed an exercise test. Frank vectorcardiography was used to assess spatiotemporal dispersion as Tampl, Tarea, the ventricular gradient (VG), and the Tpeak-end interval from 10-s signal averages before and 7 ± 2 min after exercise; during exercise too much signal disturbance excluded analysis. Baseline and maximum heart rates as well as estimated exercise intensity were similar, but heart rate recovery was slower in patients. At baseline, QT and heart rate-corrected QT (QTcB) were significantly longer in patients (as expected), whereas dispersion parameters were numerically larger in controls. After exercise, QTpeakcB and Tpeak-endcB increased significantly more in patients (18 ± 23 vs. 7 ± 10 ms and 12 ± 17 vs. 2 ± 6 ms; P < 0.001 and P < 0.01). There was, however, no difference in the change in Tampl, Tarea, and VG between groups. In conclusion, although temporal dispersion of repolarization increased significantly more after exercise in patients with LQT1, there were no signs of exercise-induced increase in global dispersion of action potential duration and morphology. The arrhythmia substrate/mechanism in LQT1 warrants further study.NEW & NOTEWORTHY Physical activity increases the risk for life-threatening arrhythmias in LQTS type 1 (LQT1). The arrhythmia substrate is presumably altered electrical heterogeneity (a.k.a. dispersion). Spatiotemporal dispersion parameters were therefore compared before and after exercise in patients versus healthy controls using Frank vectorcardiography, a novelty. Physical exercise prolonged the time between the earliest and latest complete repolarization in patients versus controls, but did not increase parameters reflecting global dispersion of action potential duration and morphology, another novelty.


Assuntos
Síndrome do QT Longo , Síndrome de Romano-Ward , Humanos , Adulto , Eletrocardiografia , Síndrome do QT Longo/diagnóstico , Vetorcardiografia , Teste de Esforço , Ventrículos do Coração , Exercício Físico/fisiologia
7.
Am J Physiol Heart Circ Physiol ; 323(5): H996-H1003, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36206051

RESUMO

There are numerous sex-related differences in cardiac electrophysiology and arrhythmia propensity but very little knowledge about the reasons. Difference in body size has been proposed as one reason and was tested in this study of >20 cardiac electrophysiology parameters in 319 (158 women) apparently healthy 50- to 64-yr-old subjects from a randomly enrolled population sample, the pilot SCAPIS (Swedish Cardiopulmonary Bioimaging Study), using Frank vectorcardiography. We studied conventional conduction intervals, parameters reflecting electrical heterogeneity (dispersion) in the ventricles, QRS- and T-vector directions, spatial QRS-T angles, and T-vector loop morphology. Body surface area (BSA; 2 methods) and lean body mass (LBM), both estimated from body weight and height, were used as body size parameters. According to multivariable linear regression analysis adjusted for sex, there was no association between electrophysiological parameters and body size apart from QRS duration and QRSarea. In conclusion, most electrophysiological parameters assessed completely noninvasively and showing statistically significant differences between women and men on the group level show no association with BSA or LBM. Scaling (indexing) the electrophysiological parameters for body size parameters is therefore not an option. Consequently, the explanation for the sex-related electrophysiological differences should be sought along other lines.NEW & NOTEWORTHY We sought explanations for sex-related differences in >20 cardiac electrophysiology parameters including conventional conduction intervals in 319 (158 women) apparently healthy 50- to 64-yr-old subjects using Frank vectorcardiography, a novelty. Our hypothesis that body size was partly explanatory for such differences had to be refuted apart from QRS duration and QRSarea. Scaling (indexing) electrophysiological parameters for body size is therefore not an option and explanations for electrophysiological sex-related differences are to be sought elsewhere.


Assuntos
Coração , Vetorcardiografia , Feminino , Humanos , Masculino , Arritmias Cardíacas , Tamanho Corporal , Coração/fisiologia , Ventrículos do Coração , Vetorcardiografia/métodos , Pessoa de Meia-Idade
8.
Pacing Clin Electrophysiol ; 45(3): 393-400, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35000207

RESUMO

BACKGROUND: QRS area, a three-dimensional QRS complex, is a novel vectorcardiography method of measuring the magnitude of electrical forces in the heart. Hypothetically, a greater QRS area denotes higher dyssynchrony and indicates potential benefits from cardiac resynchronization therapy (CRT). Previous studies suggest a positive correlation between QRS area and the degree of response to CRT, but its clinical use remains unclear. We performed a meta-analysis of the relationship between QRS area and survival benefit following CRT. METHODS: We comprehensively searched the MEDLINE, EMBASE, and Cochrane databases from inception to August 2021. We included studies with prospective and retrospective cohort designs that reported QRS area before CRT and total mortality. Data from each study were analyzed using a random-effects model. The results were reported as a hazard ratio (HR) and 95% confidence intervals. RESULTS: Five observational studies including 4931 patients were identified. The cut-off values between large and small QRS areas ranged from 102 to 116 µVs. Our analysis showed a larger QRS area was statistically associated with increased 5-year survival in patients implanted with CRT (HR pooled 0.48, 95% CI 0.46-0.51, I2  = 54%, p < .0001). Greater QRS area reduction (pre- and post-implantation) were associated with a lower total mortality rate (HR pooled 0.45, 95% CI 0.38-0.52, I2  = 0%, p < .0001). CONCLUSION: Larger pre-implantation QRS area was associated with increased survival after CRT. QRS area reduction following CRT implantation was also associated with lower mortality. QRS area may potentially become an additional selection criterion for CRT implantations.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia , Insuficiência Cardíaca/terapia , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento , Vetorcardiografia/métodos
9.
J Electrocardiol ; 70: 79-83, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34971852

RESUMO

BACKGROUND: Patients with atrial septal defects and pulmonary hypertension would benefit from early identification and treatment of pulmonary hypertension prior to closure. Noninvasive screening tools for pulmonary hypertension are inadequate. Electrocardiography, though readily available, has so far been of limited screening utility in patients with pulmonary hypertension. We hypothesize that derived vectorcardiographic parameters will aid in identifying increased right ventricular afterload and thus provide an additional screening tool for pulmonary hypertension in patients with secundum atrial septal defects. OBJECTIVE: Establish whether vectorcardiography can be used to screen for pulmonary hypertension. METHODS: A retrospective review of patients with secundum atrial septal defects (ASD) who underwent cardiac catheterization at the University of Minnesota from 2012 to 2020 was performed. We excluded patients with other congenital heart diagnoses, insufficient hemodynamic data, or lacking sinus rhythm electrocardiogram at time of cardiac catheterization. Parameters analyzed included: Sokolow-Lion right ventricular hypertrophy criteria, PR duration, QRS duration, corrected QT intervals, QRS and T wave frontal plane axes, rSR', R' amplitude, as well as vectorcardiographic parameters (Kors regression-related method), the QRS vector magnitude, T wave vector magnitude, and the spatial QRS-T angle. These were compared to measures of pulmonary hypertension obtained at cardiac catheterization. RESULTS: The spatial QRS-T angle significantly differentiated ASD patients with pulmonary hypertension (median 104 degrees, interquartile range 55-137 degrees) from ASD patients without pulmonary hypertension (median 37 degrees, interquartile range 21-63 degrees, p-value of 0.002). At a cut-off of 124 degrees, the positive and negative predictive values for identification of pulmonary hypertension were 36.4% and 96.4%, respectively, with an odds ratio of 13.4 (95% confidence interval of 2.9 to 63.7). The positive predictive value was significantly improved when combined with echocardiographic data to screen for pulmonary hypertension. CONCLUSION: The spatial QRS-T angle is associated with pulmonary hypertension in patients with secundum atrial septal defects.


Assuntos
Comunicação Interatrial , Hipertensão Pulmonar , Ecocardiografia , Eletrocardiografia , Comunicação Interatrial/diagnóstico , Ventrículos do Coração , Humanos , Hipertensão Pulmonar/diagnóstico , Vetorcardiografia/métodos
10.
Ter Arkh ; 94(9): 1122-1125, 2022 Oct 24.
Artigo em Russo | MEDLINE | ID: mdl-36286765

RESUMO

The vector concept in the analysis of the electrical signals of the heart began to be used at the dawn of the development of electrocardiology. For several decades, vectorcardiography has developed in parallel with electrocardiography; reached its peak in the 60s, and after a period of cooling experienced a resurgence since the early 90s, when it became possible to mathematically synthesize vectorcardiograms (VCG) from digital electrocardiograms in 12 leads. VCG reflects the same phenomena as electrocardiography, but allows you to calculate and visualize a number of three-dimensional characteristics of the electrical signals of the heart. The article describes the main milestones in the development of the VCG, the history of international cooperation in this area, the contribution of domestic scientists to this field of science. Modern promising areas of research related to the vector concept of the analysis of the electrical signals of the heart are briefly reflected.


Assuntos
Eletrocardiografia , Vetorcardiografia , Humanos , Vetorcardiografia/métodos , Eletrocardiografia/métodos , Coração
11.
Neuroimage ; 236: 118078, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33878376

RESUMO

The cardiac cycle induces blood volume pulsations in the cerebral microvasculature that cause subtle deformation of the surrounding tissue. These tissue deformations are highly relevant as a potential source of information on the brain's microvasculature as well as of tissue condition. Besides, cyclic brain tissue deformations may be a driving force in clearance of brain waste products. We have developed a high-field magnetic resonance imaging (MRI) technique to capture these tissue deformations with full brain coverage and sufficient signal-to-noise to derive the cardiac-induced strain tensor on a voxel by voxel basis, that could not be assessed non-invasively before. We acquired the strain tensor with 3 mm isotropic resolution in 9 subjects with repeated measurements for 8 subjects. The strain tensor yielded both positive and negative eigenvalues (principle strains), reflecting the Poison effect in tissue. The principle strain associated with expansion followed the known funnel shaped brain motion pattern pointing towards the foramen magnum. Furthermore, we evaluate two scalar quantities from the strain tensor: the volumetric strain and octahedral shear strain. These quantities showed consistent patterns between subjects, and yielded repeatable results: the peak systolic volumetric strain (relative to end-diastolic strain) was 4.19⋅10-4 ± 0.78⋅10-4 and 3.98⋅10-4 ± 0.44⋅10-4 (mean ± standard deviation for first and second measurement, respectively), and the peak octahedral shear strain was 2.16⋅10-3 ± 0.31⋅10-3 and 2.31⋅10-3 ± 0.38⋅10-3, for the first and second measurement, respectively. The volumetric strain was typically highest in the cortex and lowest in the periventricular white matter, while anisotropy was highest in the subcortical white matter and basal ganglia. This technique thus reveals new, regional information on the brain's cardiac-induced deformation characteristics, and has the potential to advance our understanding of the role of microvascular pulsations in health and disease.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Microvasos/diagnóstico por imagem , Neuroimagem/métodos , Vetorcardiografia , Adulto , Encéfalo/irrigação sanguínea , Feminino , Humanos , Masculino
12.
Am J Physiol Heart Circ Physiol ; 320(1): H381-H392, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33164576

RESUMO

Adequate adaptation of ventricular repolarization (VR) duration to changes in heart rate (HR) is important for cardiac electromechanical function and electrical stability. We studied the QT and QTpeak adaptation in response to abrupt start and stop of atrial and ventricular pacing on two occasions with an interval of at least 1 mo in 25 study subjects with permanent pacemakers. Frank vectorcardiography was used for data collection. Atrial or ventricular pacing was performed for 8 min aiming at a cycle length (CL) of 500 ms. We measured the immediate response (IR), the time constant (τ) of the exponential phase, and T90 End, the time to reach 90% change of QT and QTpeak from baseline to steady state during and after pacing. During atrial pacing, the CL decreased on average 45% from mean (SD) 944 (120) to 518 (46) ms and QT decreased on average 18% from 388 (20) to 318 (17) ms. For QT, T90 End was 103 (24) s and 126 (15) s after start versus stop of atrial pacing; a difference of 24 (27) s (P = 0.006). The response pattern was similar for τ but IR did not differ significantly between pacing start and stop. The response pattern was similar for QTpeak and also for QT and QTpeak following ventricular pacing start and stop. The coefficients of variation for repeated measures were 7%-21% for T90 End and τ. In conclusion, the adaptation of VR duration was significantly more rapid following increasing than decreasing HR and intraindividually a relatively reproducible process.NEW & NOTEWORTHY We studied the duration of ventricular repolarization (VR) adaptation and its hysteresis, following increasing and decreasing heart rate by abrupt start and stop of 8-min atrial or ventricular pacing in study subjects with permanent pacemakers and repeated the protocol with ≥1 mo interval, a novel approach. VR adaptation was significantly longer following decreasing than increasing heart rate corroborating previous observations. Furthermore, VR adaptation was intraindividually a reproducible and, hence, robust phenomenon, a novel finding.


Assuntos
Potenciais de Ação , Estimulação Cardíaca Artificial , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Marca-Passo Artificial , Síndrome do Nó Sinusal/terapia , Adaptação Fisiológica , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Síndrome do Nó Sinusal/diagnóstico , Síndrome do Nó Sinusal/fisiopatologia , Fatores de Tempo , Vetorcardiografia
13.
J Electrocardiol ; 68: 90-100, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34411881

RESUMO

BACKGROUND: Regional differences in ventricular activation sequence and action potential duration and morphology result in dispersion in ventricular repolarization (VR). VR dispersion is a key factor in arrhythmogenesis. We studied the adaptation of global VR dispersion in humans during normal and abnormal ventricular activation, and the relation to the QT adaptation (hysteresis). METHODS: We measured global VR dispersion as T amplitude, T area, and ventricular gradient (VG), using continuous Frank vectorcardiography, in response to abrupt and sustained atrial (AP) or ventricular pacing (VP) aiming at 120 bpm, in 21 subjects with permanent pacemakers. RESULTS: Following pacing start, VR adaptation showed an initially rapid and complex tri-phasic pattern, most pronounced for T amplitude. There were major differences in the patterns of VR dispersion adaptation following abrupt AP vs VP, confirming that the adaptation pattern is activation dependent. In response to AP, an instantaneous decrease in VR dispersion occurred, followed by an increase and then a slow decrease, all at a lower level than baseline. In contrast, following VP there was an immediate increase to ~4× baseline in T amplitude and T area (but not in VG), with a subsequent biphasic adaptation lasting longer during VP than AP. The initial rapid changes occurred within the time for QT adaptation to reach steady-state. CONCLUSIONS: Our results corroborate and expand data from animal and invasive human studies, showing similarities of the adaptation pattern on different scales. The initial rapidly changing VR adaptation phase presumably reflects a window of increased vulnerability to arrhythmias.


Assuntos
Adaptação Fisiológica , Eletrocardiografia , Animais , Arritmias Cardíacas , Frequência Cardíaca , Ventrículos do Coração , Humanos , Vetorcardiografia
14.
J Electrocardiol ; 68: 80-84, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34392139

RESUMO

BACKGROUND: Vectorcardiography (VCG) has demonstrated diagnostic value in the assessment of hypertrophic cardiomyopathy (HCM), however, determining its prognostic value over time has not yet been investigated. This study sought to assess the correlation of VCG parameters with the progression of HCM. METHODS: A retrospective chart review of 119 pediatric patients with diagnosis of HCM at the University of Minnesota. Eighty-three cases were excluded because of age, presence of congenital heart disease, not meeting criteria for HCM or negative phenotype. Sample was divided into 2 groups based on the presence or not of cardiac events (ventricular tachycardia, cardiac arrest, ventricular assist device, heart transplant). Derived vectorcardiography from standard 12­lead ECG was obtained for the first ECG and last available or prior to sentinel event. RESULTS: Of the 36 cases that met inclusion criteria, 9 (25%) developed a sentinel event. The median age for the event group was 10.1 ± 7.5 years and for the non-event group was 8.7 ± 6.35 years. There was no significant difference in age or sex between the groups. The T wave vector magnitude value was significantly smaller in the event group than in the non-event group (0.302 ± 0.146 mV Vs. 0.561 ± 0.305 mV, p 0.002), with a hazard ratio of 0.651 (95% CI 0.463 to 0.915). No other parameter showed significant difference between the two groups. CONCLUSIONS: The T wave vector magnitude may predict sentinel events in HCM. Prospective studies are necessary to evaluate the utility of the evolution of VCG parameters.


Assuntos
Cardiomiopatia Hipertrófica , Morte Súbita Cardíaca , Adolescente , Cardiomiopatia Hipertrófica/diagnóstico , Criança , Pré-Escolar , Humanos , Prognóstico , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco , Vetorcardiografia
15.
J Cardiovasc Electrophysiol ; 31(2): 410-416, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31840899

RESUMO

BACKGROUND: Radiofrequency catheter ablation of idiopathic ventricular arrhythmias (VAs) is performed to eliminate symptoms and to prevent or reverse arrhythmia-induced cardiomyopathy. Preprocedural prediction of the chamber of VA origin is critical for patient counseling, procedure planning, and guidance of invasive mapping. OBJECTIVE: We aimed to assess the performance of manual expert versus automated 12-lead electrocardiogram (ECG) analysis in the prediction of VA origin. METHODS: Patients with ablation of idiopathic VA and sustained success were included. The VA origin was defined as the site where ablation caused arrhythmia suppression. Standard baseline 12-lead ECGs with documentation of the VA were analyzed manually in a blinded fashion by three electrophysiologists and three electrophysiology (EP) fellows. In addition, the same standard 12-lead ECG was analyzed by an automated computer algorithm using a vectorcardiographic approach. RESULTS: Thirty-eight patients (median age, 47 [interquartile range, 37-58]; 68% female) were enrolled. The VA originated from the right ventricle in 24 (63%) and the left ventricle in 14 (37%) patients. The electrophysiologists and EP fellows identified the VA chamber of origin with a similar accuracy of 73% and 72% (P = .72). The automated algorithm showed a higher accuracy of 89% (P = .03 compared with electrophysiologists and EP fellows). This resulted in a sensitivity of 95% and specificity of 86%. CONCLUSION: While the manual ECG analysis of the standard 12-lead ECG by both electrophysiologists and EP fellows correctly identified the chamber of VA origin in around 75% of cases, an automated vectorcardiographic computer algorithm achieved an accuracy of 89% with clinically acceptable diagnostic parameters.


Assuntos
Potenciais de Ação , Eletrocardiografia , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Processamento de Sinais Assistido por Computador , Taquicardia Ventricular/diagnóstico , Função Ventricular Esquerda , Função Ventricular Direita , Complexos Ventriculares Prematuros/diagnóstico , Adulto , Idoso , Automação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Vetorcardiografia , Complexos Ventriculares Prematuros/fisiopatologia
16.
Cardiology ; 145(12): 784-794, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32957097

RESUMO

BACKGROUND: There is a need for refined risk stratification of sudden cardiac death and prediction of ventricular arrhythmias to correctly identify patients who are expected to benefit the most from implantable cardioverter-defibrillator (ICD) therapy. METHODS: We conducted a registry-based retrospective observational study on patients with either ischemic (ICMP) or nonischemic dilated cardiomyopathy (NICMP) treated with ICD between 2002 and 2013 at a tertiary referral center. We evaluated 3 vectorcardiography (VCG) indices; spatial QRS-T angle, QRS vector magnitude (QRSvm), and T-wave vector magnitude (Twvm), and their association with all-cause mortality and ventricular arrhythmias. The VCG indices were automatically computed from resting 12-lead electrocardiograms before ICD implantation. RESULTS: 178 patients were included in the study; 53.4% had ICMP, 79.2% were male, and mean ejection fraction was 27.4%. During the follow-up (median 89 months), 40 patients (23%) died; 31% had appropriate ICD therapy. In multivariate analysis with dichotomized variables, QRS-T angle >152° and Twvm <0.38 mV were significantly associated with increased mortality: HR 2.64 (95% CI 1.14-6.12, p = 0.02) and HR 5.30 (95% CI 2.31-12.11, p < 0.001), respectively. QRSvm <1.54 mV was borderline significant with mortality outcome (p = 0.10). The composite score of all 3 VCG indices, a score of 3, conferred an increased risk of mortality (including heart failure mortality) in multivariate analysis: HR 13.80 (95% CI 3.44-55.39, p < 0.001). CONCLUSION: The spatial QRS-T angle and Twvm are emerging VCG indices which are independently associated with mortality in patients with reduced left ventricular ejection fraction due to ICMP or NICMP. Using a composite score of all 3 vector indices, a maximum score was associated with poor long-term survival.


Assuntos
Arritmias Cardíacas , Desfibriladores Implantáveis , Insuficiência Cardíaca , Vetorcardiografia , Arritmias Cardíacas/mortalidade , Morte Súbita Cardíaca , Humanos , Masculino , Fatores de Risco , Volume Sistólico , Função Ventricular Esquerda
17.
J Electrocardiol ; 59: 164-170, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32160573

RESUMO

INTRODUCTION: The vectorcardiography (VCG) is a method of representing the heart's electrical activity in three dimensions that is not frequently used in clinical practice due to the higher complexity compared to electrocardiography (ECG). A way around this problem was the development of regression techniques to obtain the VCG from the 12­lead ECG and the evaluation of these techniques is done by comparing the parameters obtained by the gold standard method and by the VCG obtained by the alternative methods. In this paper it is proposed instead a comparison between the images of the VCG planes using the values returned by digital image processing metrics such as PSNR, SSIM and PW-SSIM. METHODS: The signals used were obtained from the Physikalisch-Technische Bundesanstalt Diagnostic ECG Database, which contains both the VCGs obtained by the gold standard method and the 12 lead ECG signals. They were divided into five groups that contained a control group and according to the region of the wall infarction. The ECG signals were then filtered using a Butterworth Finite Impulse Response bandpass filter, with cutoff frequencies of 3 Hz and 45 Hz and then the VCGs were by a computer application using the Kors inverse matrix method, the Kors quasi-orthogonal method and the Dower Inverse Matrix method. The reconstructed signals were then compared using the PSNR, SSIM and PW-SSIM methods. The returned values were presented in tables for each group containing the average value and standard deviance for each method in each VCG plane. RESULTS: Using image processing techniques, it was possible to perceive that the alternative methods to obtain the VCG have a high confiability that could be compared to the gold standard in signals from healthy subjects. However, signals from pathological subjects present variations that could be caused by a deficit of these alternative methods to represent the pathology in these cases. Considering the PW-SSIM, the Frontal plane by the reconstructions was considered the most similar to the gold standard, having PW-SSIM values higher than 0.93 and for the Horizontal plane two groups had PW-SSIM values lower than 0.90 and for the Sagittal plane all groups had values lower than this value. DISCUSSION: The values yielded by the PSNR and SSIM had low variance, worsening the perception of the effect of the reconstruction method used or the infarction effect over the reconstruction. The values lower than 0.90 could indicate that these planes have their generation most affected by the infarction. CONCLUSION: The three methods of obtaining the VCG Frank leads, the Kors Quasi-Orthogonal method, the Kors Linear Regression method and the Dower Inverse Matrix, presented differences in the metrics: PSNR, SSIM and PW-SSIM in normal subjects according to the planes frontal, horizontal and sagittal and in subjects with Myocardial Infarction according to its topography: anterior, inferolateral, inferior or multiarterials. Considering only the PW-SSIM, the QO method had the best performance in different signals, followed by the Dower method.


Assuntos
Eletrocardiografia , Infarto do Miocárdio , Humanos , Processamento de Imagem Assistida por Computador , Software , Vetorcardiografia
18.
J Electrocardiol ; 61: 112-120, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32599289

RESUMO

BACKGROUND: The spatial peak and mean QRS-T angles are scientifically but not clinically established risk factors for cardiovascular events including cardiac death. The study aims were to compare these angles, assess their association with hypertension (HT) and diabetes mellitus (DM), and explore the relation between the mean QRS-T angle and the ventricular gradient (VG; reflecting electrical heterogeneity), which both are derived from the QRSarea and Tarea vectors. METHODS: Altogether 1094 participants (aged 50-65 years, 550 women) from the pilot of the population-based Swedish CArdioPulmonary bioImage Study with Frank vectorcardiographic recordings were included and divided into 5 subgroups: apparently healthy n = 320; HT n = 311; DM n = 33; DM + HT n = 53; miscellaneous conditions n = 377. Abnormal peak and mean QRS-T angles were defined as >95th percentile. RESULTS: Peak QRS-T angles were generally narrower than the mean QRS-T angles; both were narrower in women than in men. Abnormal peak (>124°) and/or mean (>119°) QRS-T angles were found in 73 participants (6.7%). The concordance regarding abnormal versus normal-borderline QRS-T angles was good (Cohen's kappa 0.61). The prevalence of abnormal angles varied from 2.5% in healthy to 21.2% in DM. There was an inverse logarithmical relation between the mean QRS-T angle and the VG. CONCLUSIONS: The peak and mean QRS-T angles are not interchangeable but complementary. DM, HT, sex and absence of disease are important determinants of both QRS-T angles. The mean QRS-T angle and the VG relationship is complex. All three VCG derived measures reflect related but differing electrophysiological properties and have potential prognostic value vis-à-vis cardiovascular events.


Assuntos
Eletrocardiografia , Hipertensão , Morte , Feminino , Humanos , Masculino , Prognóstico , Fatores de Risco , Vetorcardiografia
19.
J Electrocardiol ; 58: 1-6, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31677533

RESUMO

BACKGROUND: Optimal timing of the atrioventricular delay in cardiac resynchronization therapy (CRT) can improve synchrony in patients suffering from heart failure. The purpose of this study was to evaluate the impact of SyncAV™ on electrical synchrony as measured by vectorcardiography (VCG) derived QRS metrics during bi-ventricular (BiV) pacing. METHODS: Patients implanted with a cardiac resynchronization therapy (CRT) device and quadripolar left ventricular (LV) lead underwent 12­lead ECG recordings. VCG metrics, including QRS duration (QRSd) and area, were derived from the ECG by a blinded observer during: intrinsic conduction, BiV with nominal atrioventricular delays (BiV Nominal), and BiV with SyncAV programmed to the optimal offset achieving maximal synchronization (BiV + SyncAV Opt). RESULTS: One hundred patients (71% male, 40% ischemic, 65% LBBB, 32 ±â€¯9% ejection fraction) completed VCG assessment. QRSd during intrinsic conduction (166 ±â€¯25 ms) was narrowed successively by BiV Nominal (137 ±â€¯23 ms, p < .05 vs. intrinsic) and BiV + SyncAV Opt (122 ±â€¯22 ms, p < .05 vs. BiV Nominal). Likewise, 3D QRS area during intrinsic conduction (90 ±â€¯42 mV ∗ ms) was reduced by BiV Nominal (65 ±â€¯39 mV ∗ ms, p < .05 vs. intrinsic) and further by BiV + SyncAV Opt (53 ±â€¯30 mV ∗ ms, p = .06 vs. BiV Nominal). CONCLUSION: With VCG-based, patient-specific optimization of the programmable offset, SyncAV reduced electrical dyssynchrony beyond conventional CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Feminino , Insuficiência Cardíaca/terapia , Frequência Cardíaca , Ventrículos do Coração , Humanos , Masculino , Resultado do Tratamento , Vetorcardiografia , Função Ventricular Esquerda
20.
J Electrocardiol ; 63: 159-163, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31324399

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) is an established treatment in patients with heart failure and conduction abnormalities. However, a significant number of patients do not respond to CRT. Currently employed criteria for selection of patients for this therapy (QRS duration and morphology) have several shortcomings. QRS area was recently shown to provide superior association with CRT response. However, its assessment was not fully automated and required the presence of an expert. OBJECTIVE: Our objective was to develop a fully automated method for the assessment of vector-cardiographic (VCG) QRS area from electrocardiographic (ECG) signals. METHODS: Pre-implantation ECG recordings (N = 864, 695 left-bundle-branch block, 589 men) in PDF files were converted to allow signal processing. QRS complexes were found and clustered into morphological groups. Signals were converted from 12­lead ECG to 3­lead VCG and an average QRS complex was built. QRS area was computed from individual areas in the X, Y and Z leads. Practical usability was evaluated using Kaplan-Meier plots and 5-year follow-up data. RESULTS: The automatically calculated QRS area values were 123 ±â€¯48 µV.s (mean values and SD), while the manually determined QRS area values were 116 ±â€¯51 ms; the correlation coefficient between the two was r = 0.97. The automated and manual methods showed the same ability to stratify the population (hazard ratios 2.09 vs 2.03, respectively). CONCLUSION: The presented approach allows the fully automatic and objective assessment of QRS area values. SIGNIFICANCE: Until this study, assessing QRS area values required an expert, which means both additional costs and a risk of subjectivity. The presented approach eliminates these disadvantages and is publicly available as part of free signal-processing software.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Eletrocardiografia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Masculino , Resultado do Tratamento , Vetorcardiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA