Your browser doesn't support javascript.
loading
Estudo do comportamento da PIO de 24 horas e frequência de glaucoma em pacientes com síndrome da apnéia obstrutiva do sono / Study on 24 hours IOP study and glaucoma frequency in patients with obstructive sleep apnea syndrome
Silva, Maria Rosa Bet de Moraes; Weber, Silke Anna Theresa.
Afiliação
  • Silva, Maria Rosa Bet de Moraes; Universidade Estadual Julio de Mesquita Filho. Faculdade de Medicina de Botucatu. Departamento de Oftalmologia, Otorrinolaringologia e Cirurgia de Cabeça e Pescoço. BR
  • Weber, Silke Anna Theresa; Universidade Estadual Julio de Mesquita Filho. Faculdade de Medicina de Botucatu. Departamento de Oftalmologia, Otorrinolaringologia e Cirurgia de Cabeça e Pescoço. BR
Rev. bras. oftalmol ; 68(6): 338-343, nov.-dez. 2009. tab, ilus
Article em Pt | LILACS | ID: lil-543765
Biblioteca responsável: BR1.2
RESUMO

OBJETIVO:

Determinar a frequência de glaucoma e avaliar o comportamento da pressão intraocular (PIO) de 24 horas em pacientes portadores da síndrome da apnéia obstrutiva do sono (SAOS).

MÉTODOS:

Foi realizado estudo transversal em 11 pacientes consecutivos portadores de SAOS diagnosticados por polissonografia. Foram analisados dados demográficos idade, sexo, raça/cor, peso, altura e doenças associadas. Os pacientes foram submetidos à avaliação oftalmológica completa que incluiu campo visual e também avaliação da pressão intraocular (PIO) de 24 horas com tonômetro de aplanação às 9h, 12h, 15h, 18h, 24h e 6h deitado e sentado. O critério para diagnóstico de glaucoma foi alteração de campo visual (CV) compatível com glaucoma e uma ou mais das seguintes alterações relação escavação disco ³ 0,7, hemorragia, defeito em cunha, vaso em baioneta, sinal de Hoyt, assimetria > que 0,2 entre as escavações dos dois olhos. O ângulo devia ser aberto sem alterações.

RESULTADOS:

9 (82 por cento) de 11 pacientes apresentaram glaucoma ou suspeita de glaucoma, sendo 9 por cento glaucoma de pressão normal e 73 por cento suspeita de glaucoma por apresentarem alterações do nervo óptico ou hipertensão ocular. A média dos valores de PIO dos 11 pacientes apresentou-se mais elevada às 6 horas quando os pacientes estavam deitados. Ocorreram flutuações de PIO ³ 5 mmHg em 7 (64 por cento) dos pacientes sendo que ocorreram flutuações de até 14 mmHg e picos de PIO de até 32 mmHg.

CONCLUSÃO:

A SAOS pode ser um fator de risco importante para o esenvolvimento de glaucoma principalmente de pressão normal. Pacientes com SAOS devem ser referidos para o oftalmologista e os oftalmologistas devem estar atentos para a associação de distúrbios do sono em pacientes com glaucoma de ângulo aberto.
ABSTRACT

PURPOSE:

To determine the frequency of glaucoma and evaluate the behavior of 24-hour intraocular pressure in patients with the obstructive sleep apnea syndrome (OSAS).

METHODS:

Eleven consecutive patients with OSAS, diagnosed by polysonography, were avaliated in a cross sectional study. Demographic data were analyzed age, sex, race/color, weight, height and associated diseases. The patients were submitted to complete ophthalmologic examination, including the visual field, as well as to 24-hour intra-ocular pressure (IOP) evaluation by an applanation tonometer at 9h, 12h, 15h, 18h, 24h and 6h in the lying and sitting positions. The diagnostic criterion for glaucoma was alteration of the visual field (VF) compatible with glaucoma and one or more of the following alterations cup-disc ratio ³ 0.7, hemorrhage, wedge-shaped defect, bayonet-shaped vessels, Hoyt's sign, asymmetry > than 0.2 between cup/disc ratio of the eyes. The angle should be opened without alterations.

RESULTS:

9 (82 percent) of 11 patients showed glaucoma or were suspected to have glaucoma, 9 percent of which exhibited normal tension glaucoma and 73 percent were suspected to have glaucoma for presenting alterations in the optic nerve or ocular hypertension. The mean for the IOP values of the 11 patients was observed to be the highest at 6 o'clock, when they were lying down. Variations of IOP ³ 5 mmHg occurred in 7 (64 percent) of the patients, and variations of up to 14 mmHg and IOP peaks of up to 32 mmHg were observed.

CONCLUSION:

OSAS may be an important risk factor for the development of glaucoma, particularly that of normal tension glaucoma. Patients with OSAS must be referred to an ophthalmologist and those professionals must be attentive to the association of sleep disorders in patients with open-angle glaucoma.
Assuntos
Palavras-chave
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Tonometria Ocular / Glaucoma de Ângulo Aberto / Hipertensão Ocular / Apneia Obstrutiva do Sono / Técnicas de Diagnóstico Oftalmológico / Pressão Intraocular Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies / Screening_studies Idioma: Pt Ano de publicação: 2009 Tipo de documento: Article
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Tonometria Ocular / Glaucoma de Ângulo Aberto / Hipertensão Ocular / Apneia Obstrutiva do Sono / Técnicas de Diagnóstico Oftalmológico / Pressão Intraocular Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies / Screening_studies Idioma: Pt Ano de publicação: 2009 Tipo de documento: Article