Your browser doesn't support javascript.
loading
Comparative study of linear measurements performed in magnetic resonance and computed tomography images with the aid of an image realignment software / Estudo comparativo de medidas realizadas em imagens por ressonância magnética e por tomografia computadorizada com auxílio de um software de realinhamento de imagens
Aust, Scheila; Corrêa, Márcio; Abreu Junior, Murillo José Nunes; Grando, Liliane Janete; Melo, Saulo Leonardo Sousa; Abdala, Daniel Duarte; Bertoldi, Rafael Floriani.
Afiliação
  • Aust, Scheila; UFSC. Florianópolis. BR
  • Corrêa, Márcio; UFSC. Faculdade de Odontologia. Radiologia Odontológica. Florianópolis. BR
  • Abreu Junior, Murillo José Nunes; UFSC. Faculdade de Odontologia. Radiologia Odontológica. Florianópolis. BR
  • Grando, Liliane Janete; UFSC. Faculdade de Odontologia. Patologia Bucal. Florianópolis. BR
  • Melo, Saulo Leonardo Sousa; s.af
  • Abdala, Daniel Duarte; s.af
  • Bertoldi, Rafael Floriani; s.af
RPG rev. pos-grad ; 15(4): 243-250, out.-dez. 2008. ilus
Article em En | LILACS | ID: lil-556110
Biblioteca responsável: BR501.1
ABSTRACT
The aim of this study was to compare linear measurements of implant sites performed in magnetic resonance and computed tomography images with the aid of an image alignment software. Four patients from the Dental Implant Research and Teaching Center of Universidade Federal de Santa Catarina, Florianópolis, Brazil, were submitted to both computed tomography and magnetic resonance scans. An image realignment software was used to allow measuring the exact same sites on the images of both modalities. A total of eighty linear measuremensts of the posterior regions and twelve linear measurement of the anterior regions were performed with each modality. Measurements were carried out by one calibrated observer. Observer's reproducibility was higher than 97% (Dalberg's error). Student's t-test was used to compare the results of the height of the alveolar process in the computed tomography and magnetic resonance images. There was no statistically significant differences between the measurements performed in the computed tomography and magnetic resonance images (p = 0.4136). with a strong correlation between them (r = 0.8346). Similarly, there was no statistically significant differences between the measurements produced by the two modalities when the analysis discriminated the anterior and posterior regions (p = 0.7801 and p = 0.4381, respectively), with a strong correlation between the measurements in the posterior region of the jaws (r = 0.8547), and a weak correlation in the anterior region (r = 0.5472). Linear measurements of the alveolar process obtained from magnetic resonance and computed tomography images are comparable.
Assuntos
Palavras-chave
Buscar no Google
Coleções: 01-internacional Base de dados: LILACS Assunto principal: Validação de Programas de Computador / Imageamento por Ressonância Magnética / Tomografia Computadorizada por Raios X Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Idioma: En Ano de publicação: 2008 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: LILACS Assunto principal: Validação de Programas de Computador / Imageamento por Ressonância Magnética / Tomografia Computadorizada por Raios X Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Idioma: En Ano de publicação: 2008 Tipo de documento: Article