Avaliação in vitro da liberação e da recarga de flúor em cimentos de ionômero de vidro / In vitro evaluation of the fluoride release and uptake by glass ionomer cements
Rev. odontol. UNESP (Online)
; 42(1): 25-30, jan.-fev. 2013. ilus
Article
em Pt
| LILACS, BBO
| ID: lil-668233
Biblioteca responsável:
BR39.2
RESUMO
Objetivo:
Este estudo avaliou a absorção de íons flúor em cimentos de ionômero de vidro de manipulação mecânica e manual, por uma única aplicação tópica de flúor.Metodologia:
Os cimentos de ionômeros de vidro (CIVs) Riva Self Cure® (RSC-SDI) e Ketac Molar Easymix® (KME- 3M-ESPE) foram testados com um material controle (RC-resina composta ICE-SDI), após preparo de dez corpos de prova de cada um (n = 30). Esses corpos foram pesados e armazenados em água deionizada para as aferições da liberação de flúor (eletrodo específico, Orion 9606-BN) em dois períodos antes (PI 1, 2, 7 e 14 dias) e após aplicação tópica de flúor (PII 16, 17, 18, 20, 22, 24, 26, 28 e 30 dias). No 15.º dia, cinco espécimes de cada material (n = 15) foram submetidos à aplicação tópica de fluoreto de sódio neutro a 2% ou de gel placebo de Natrosol (n = 15).Resultado:
A maior liberação de íons flúor para ambos os CIVs ocorreu no primeiro dia do PI (KME = 13,44 ± 6,05; RSC = 6,88 ± 0,62) e a quantidade liberada foi semelhante no PII (KME = 6,22 ± 0,80; RSC = 6,67 ± 1,63). A comparação entre os períodos mostrou diferença significante somente para o KME, com maior liberação de flúor no PI (p < 0,05), e para o RSC, não foi detectada diferença entre PI e PII (p >0,05). A análise de variância e o teste de Tukey (p < 0,05) não indicaram diferenças significantes entre os materiais antes e após a recarga.Conclusão:
Os CIVs de manipulação mecânica ou manual possuem habilidade semelhante para captar íons flúor, quando submetidos a uma única aplicação tópica de fluoreto de sódio a 2%.ABSTRACT
Objective:
This study evaluated the uptake of fluoride ions on glass ionomer cements of manipulation mechanical and manual by a unique fluoride topical application.Methodology:
The glass ionomer cements (GICs) Riva Self Cure® (RSC-SDI) and Ketac Molar Easymix® (KME-3M-ESPE) were tested with a control material (RC-composite resin ICE-SDI) after making ten specimens of each one (n = 30).These were weighed and stored in deionized water for measurements of fluoride release (specific electrode, Orion 9606-BN) into two periods, before (PI 1, 2, 7 and 14 days) and after topical application of fluoride (PII 16, 17, 18, 20, 22, 24, 26, 28 and 30 days). On the 15th day, five specimens of each material (n = 15) were submitted to a topical application of sodium fluoride to 2% or placebo gel of Natrosol (n = 15).Result:
The high release of fluoride for both GICs occurred on the first day of the PI (KME = 13.44 ± 6.05; RSC = 6.88 ± 0.62) and the amount of fluoride released was similar for the PII (KME = 6.22 ± 0.80; RSC = 6.67 ± 1.63). The comparison between periods showed significant differences only for the KME with higher fluoride release in PI (p < 0.05) and no difference was detected between PI and PII (p > 0.05) for the RSC. The analysis of variance and the Tukey test (p < 0.05) indicated no significant differences between the materials before and after recharging.Conclusion:
The GICs of manipulation mechanical and manual have similar ability to uptake fluoride ions when subjected to a single topical application of sodium fluoride to 2%.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
BBO
/
LILACS
Assunto principal:
Fluoreto de Sódio
/
Técnicas In Vitro
/
Análise de Variância
/
Materiais Dentários
/
Flúor
/
Cimentos de Ionômeros de Vidro
Tipo de estudo:
Clinical_trials
Idioma:
Pt
Ano de publicação:
2013
Tipo de documento:
Article