Your browser doesn't support javascript.
loading
Ultrasound method applied to characterize healthy femoral diaphysis of Wistar rats in vivo
Fontes-Pereira, A.; Matusin, D.P.; Rosa, P.; Schanaider, A.; von Krüger, M.A.; Pereira, W.C.A..
Afiliação
  • Fontes-Pereira, A.; Universidade Federal do Rio de Janeiro. Programa de Engenharia Biomédica. Rio de Janeiro. BR
  • Matusin, D.P.; Universidade Federal do Rio de Janeiro. Programa de Engenharia Biomédica. Rio de Janeiro. BR
  • Rosa, P.; Universidade Federal do Rio de Janeiro. Programa de Engenharia Biomédica. Rio de Janeiro. BR
  • Schanaider, A.; Universidade Federal do Rio de Janeiro. Programa de Engenharia Biomédica. Rio de Janeiro. BR
  • von Krüger, M.A.; Universidade Federal do Rio de Janeiro. Programa de Engenharia Biomédica. Rio de Janeiro. BR
  • Pereira, W.C.A.; Universidade Federal do Rio de Janeiro. Programa de Engenharia Biomédica. Rio de Janeiro. BR
Braz. j. med. biol. res ; 47(5): 403-410, 02/05/2014. tab, graf
Article em En | LILACS | ID: lil-709440
Biblioteca responsável: BR1.1
ABSTRACT
A simple experimental protocol applying a quantitative ultrasound (QUS) pulse-echo technique was used to measure the acoustic parameters of healthy femoral diaphyses of Wistar rats in vivo. Five quantitative parameters [apparent integrated backscatter (AIB), frequency slope of apparent backscatter (FSAB), time slope of apparent backscatter (TSAB), integrated reflection coefficient (IRC), and frequency slope of integrated reflection (FSIR)] were calculated using the echoes from cortical and trabecular bone in the femurs of 14 Wistar rats. Signal acquisition was performed three times in each rat, with the ultrasound signal acquired along the femur's central region from three positions 1 mm apart from each other. The parameters estimated for the three positions were averaged to represent the femur diaphysis. The results showed that AIB, FSAB, TSAB, and IRC values were statistically similar, but the FSIR values from Experiments 1 and 3 were different. Furthermore, Pearson's correlation coefficient showed, in general, strong correlations among the parameters. The proposed protocol and calculated parameters demonstrated the potential to characterize the femur diaphysis of rats in vivo. The results are relevant because rats have a bone structure very similar to humans, and thus are an important step toward preclinical trials and subsequent application of QUS in humans.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Densidade Óssea / Ultrassonografia / Fêmur Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Densidade Óssea / Ultrassonografia / Fêmur Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2014 Tipo de documento: Article