Your browser doesn't support javascript.
loading
Correlación clínico-patológica de las Microvacuolas o ‘Glistenings’ en 100 lentes intraoculares (Lios) Acrysof Explantados / Clinicopathological correlation of microvacules or ‘glistenings’ in 100 explanted AcrySof intraocular lens (IOLs)
Escobar-Gómez, Marcela; Apple, David J; Borkenstein, Andreas F.
Afiliação
  • Escobar-Gómez, Marcela; s.af
  • Apple, David J; s.af
  • Borkenstein, Andreas F; s.af
Article em Es | LILACS | ID: lil-779442
Biblioteca responsável: CO176.1
RESUMEN
Resumen Propósito analizar los LIOs acrílicos hidrofóbicos AcryS of de nuestro banco de lentes explantados para establecer la presencia de microvacuolas(glistenings), determinar su frecuencia y definir si existe una correlación con los datos clínicos para cada uno.Materiales y

Métodos:

se realizó análisis clínico-patológico de todos los lentes hidrofóbicos AcrySof® (n=100) que hacen parte del banco de más de 5.000 explantes de nuestro laboratorio. Se efectuó evaluación microscópica y se determinó la presencia de las microvacuolas; adicionalmente se estimó la severidad de las mismas y se hizo una correlación con los datos clínicos para cada lente.

Resultados:

el análisis foto microscópico reveló la presencia de microvacuolas en 43 de los 100 LIOs evaluados las microvacuolas fueron clasificadas como...
ABSTRACT

Purpose:

To analyze the AcrySof hydrophobic intraocular lens from our database in order to establish the presence of the microvacuoles (glistenigs), determine its frequency, and define clinicopathological correlation in each case.Materials and

Methods:

A clinicopathological analysis was performed in all the explanted AcrySof IOLs (n=100) that were accessioned in ourlaboratory database of more than 5,000 explants. Applying photo microscopy, we estimated the number of ‘glistenings’cases, evaluated their severity, and correlated them with clinical findings.

Results:

The laboratory analysis revealed microvacules in 43 out of the 100 evaluated lenses. Of those cases, 14 were mild, 17 were moderate, and 12 were marked. Of the 43 lenses in which the vacuoles were identified, only 6 had been diagnosed clinically...
Assuntos
Palavras-chave
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Vacúolos / Lentes Intraoculares Tipo de estudo: Prognostic_studies Idioma: Es Ano de publicação: 2011 Tipo de documento: Article
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Vacúolos / Lentes Intraoculares Tipo de estudo: Prognostic_studies Idioma: Es Ano de publicação: 2011 Tipo de documento: Article