Clinical evaluation of the Gyro Pump C1E3 as a cardiopulmonary bypass pump.
Orime, Y; Shiono, M; Yagi, S; Yamamoto, T; Okumura, H; Kimura, S; Hata, M; Sezai, A; Kashiwazaki, S; Choh, S; Negishi, N; Sezai, Y; Matsui, T; Suzuki, M.
Afiliação
  • Orime Y; Second Department of Surgery, Nihon University School of Medicine, Japan.
ASAIO J ; 46(1): 128-33, 2000.
Article em En | MEDLINE | ID: mdl-10667731
ABSTRACT
The Gyro Pump C1E3 is a new centrifugal pump with numerous features, including a ceramic pivot bearing system, secondary vanes, and an eccentric inlet port. To evaluate its biocompatibility, antithrombogenicity, and produced hemolysis, we used the Gyro Pump during cardiopulmonary bypass (CPB) for coronary artery bypass grafting (CABG) cases to compare it with the BioMedicus pump. From September 1998 to February 1999, 30 consecutive patients underwent CABG under conventional CPB. Fifteen patients were supported by the Gyro Pump C1E3 (Group G), and the remaining 15 patients, by a BioMedicus BP-80 pump (Group B). In both groups, flow rate was equivalent. Blood samples were taken as follows preoperative, 60 minutes after the end of the procedure, and at postoperative days (POD) 0, 1, and 2. We evaluated the plasma free hemoglobin (free Hb) as an indication of hemolysis; beta-thromboglobulin (beta-TG) and platelet factor four (PF-4) as an indication of platelet deterioration; C3, C4, CH50 for complement activation; coagulation parameters, fibrinolytic factor, thrombomodulin, nitric oxide (NO), and endothelin as an indication of endothelial deterioration. This was the first clinical sized Gyro Pump CIE3. De-airing from the pump was easily accomplished via the eccentric oblique inlet port. The system, including its console, was easily and simply controlled. Perioperative laboratory data were not markedly changed in either group with demonstrated equivalence for biocompatibility and hemolysis. After pumping, no thrombus formation or pivot wear were observed inside the pump. This atraumatic, small centrifugal pump appears well suited not only for CPB but also for circulatory support.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ponte Cardiopulmonar / Coração Auxiliar Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2000 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ponte Cardiopulmonar / Coração Auxiliar Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2000 Tipo de documento: Article