An experimental teleradiology transmission system using a high-speed ATM backbone network.
J Telemed Telecare
; 6(2): 114-8, 2000.
Article
em En
| MEDLINE
| ID: mdl-10824380
We evaluated the performance of an experimental teleradiology system based on a high-speed ATM backbone network. Image acquisition, transmission and the disk-to-display processing times were measured. Computerized tomography (CT) scans printed on 14 inch x 17 inch (36 cm x 43 cm) films were digitized and transferred over the network. The average time for the entire process was 1 min 30 s. Three radiologists interpreted 20 cases. For CT image interpretation, the reading time for one case ranged from 2 to 12 min (mean 6 min 46 s) on a monitor, and from 1 to 3 min (mean 1 min 31 s) with the original film. The ATM backbone network operating at 156 Mbit/s provided sufficient speed for remote consultation. However, further improvements in the operability of the system, especially the image viewing station, are necessary before it will be satisfactory for clinical use.