Your browser doesn't support javascript.
loading
Reproducibility of an automatic quantitation of regional myocardial wall motion and systolic thickening on gated 99mTc-sestamibi myocardial SPECT.
Paeng, J C; Lee, D S; Cheon, G J; Lee, M M; Chung, J K; Lee, M C.
Afiliação
  • Paeng JC; Department of Nuclear Medicine and Internal Medicine, Seoul National University College of Medicine, Seoul, Korea.
J Nucl Med ; 42(5): 695-700, 2001 May.
Article em En | MEDLINE | ID: mdl-11337562
UNLABELLED: We investigated the reproducibility of an automatic quantitative algorithm for measuring regional myocardial wall motion and systolic thickening. METHODS: 99mTc-sestamibi gated myocardial SPECT with dipyridamole stress was performed twice consecutively on 31 patients with known or suspected coronary artery disease, with the patients in the same position for each scan. With AutoQUANT software, segmental wall motion and systolic thickening were quantified automatically and expressed in millimeters and percentage increase, respectively, for 20 segments. Afterward, the correlation and agreement between repeated measurements were investigated, and the influences of wall location, perfusion grade, and partitioning of the myocardium on reproducibility were evaluated by ANOVA and t testing. RESULTS: High correlations (r = 0.95 for wall motion and 0.88 for systolic thickening) and good agreements (weighted kappa = 0.81 and 0.71, respectively) were obtained from repeated measurements on consecutive gated SPECT. Changes in wall location and perfusion grade did not cause significant differences between repeated measurements (P > 0.05 in ANOVA and t testing), but a change in partitioning did. On Bland-Altman analysis, 2 SDs for repeated wall motion and for systolic thickening were 2.0 mm and 20%, respectively. CONCLUSION: The automatic quantitative algorithm for myocardial SPECT provided by AutoQUANT software has good reproducibility under diverse conditions. A change of motion > 2.0 mm or a change of systolic thickening > 20% can be regarded as significant during a follow-up study using this software.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imagem do Acúmulo Cardíaco de Comporta / Tomografia Computadorizada de Emissão de Fóton Único / Tecnécio Tc 99m Sestamibi / Compostos Radiofarmacêuticos / Doença das Coronárias / Contração Miocárdica Tipo de estudo: Observational_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2001 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imagem do Acúmulo Cardíaco de Comporta / Tomografia Computadorizada de Emissão de Fóton Único / Tecnécio Tc 99m Sestamibi / Compostos Radiofarmacêuticos / Doença das Coronárias / Contração Miocárdica Tipo de estudo: Observational_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2001 Tipo de documento: Article