Your browser doesn't support javascript.
loading
Rapid evaluation of left ventricular volume and mass without breath-holding using real-time interactive cardiac magnetic resonance imaging system.
Kaji, S; Yang, P C; Kerr, A B; Tang, W H; Meyer, C H; Macovski, A; Pauly, J M; Nishimura, D G; Hu, B S.
Afiliação
  • Kaji S; Department of Medicine, Stanford University, California, USA.
J Am Coll Cardiol ; 38(2): 527-33, 2001 Aug.
Article em En | MEDLINE | ID: mdl-11499748
ABSTRACT

OBJECTIVES:

The purpose of this study was to validate cardiac measurements derived from real-time cardiac magnetic resonance imaging (MRI) as compared with well-validated conventional cine MRI.

BACKGROUND:

Although cardiac MRI provides accurate assessment of left ventricular (LV) volume and mass, most techniques have been relatively slow and required electrocardiogram (ECG) gating over many heart beats. A newly developed real-time MRI system allows continuous real-time dynamic acquisition and display without cardiac gating or breath-holding.

METHODS:

Fourteen healthy volunteers and nine patients with heart failure underwent real-time and cine MRI in the standard short-axis orientation with a 1.5T MRI scanner. Nonbreath-holding cine MRI was performed with ECG gating and respiratory compensation. Left ventricular end-diastolic volume (LVEDV), left ventricular endsystolic volume (LVESV), ejection fraction (EF) and LV mass calculated from the images obtained by real-time MRI were compared to those obtained by cine MRI.

RESULTS:

The total study time including localization for real-time MRI was significantly shorter than cine MRI (8.6 +/- 2.3 vs. 24.7 +/- 3.5 min, p < 0.001). Both imaging techniques yielded good quality images allowing cardiac measurements. The measurements of LVEDV, LVESV, EF and LV mass obtained with real-time MRI showed close correlation with those obtained with cine MRI (LVEDV r = 0.985, p < 0.001; LVESV r = 0.994, p < 0.001; EF r = 0.975, p < 0.001; LV mass r = 0.977, p < 0.001).

CONCLUSIONS:

Real-time MRI provides accurate measurements of LV volume and mass in a time-efficient manner with respect to image acquisition.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Hipertrofia Ventricular Esquerda / Disfunção Ventricular Esquerda Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2001 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Hipertrofia Ventricular Esquerda / Disfunção Ventricular Esquerda Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2001 Tipo de documento: Article