His-bundle parasystole masquerading as exercise-induced 2:1 atrioventricular block.
J Cardiovasc Electrophysiol
; 12(8): 965-7, 2001 Aug.
Article
em En
| MEDLINE
| ID: mdl-11513450
We describe a case of symptomatic pseudo-AV block due to His-bundle parasystole masquerading as exercise-induced 2:1 AV block. Electrophysiologic study revealed the presence of His-bundle parasystole, and the fluctuation of parasystolic cycle length could be explained by the concept of modulated parasystole. Modulated parasystole is a possible explanation for maintenance of stable 2:1 AV conduction at an atrial rate of specific range during exercise.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Fascículo Atrioventricular
/
Exercício Físico
/
Parassístole
/
Átrios do Coração
/
Bloqueio Cardíaco
Tipo de estudo:
Diagnostic_studies
Limite:
Aged
/
Aged80
/
Humans
/
Male
Idioma:
En
Ano de publicação:
2001
Tipo de documento:
Article