Quantification of elastic recoil after balloon angioplasty in the iliac arteries.
Gardiner, G A; Bonn, J; Sullivan, K L.
Afiliação
  • Gardiner GA; Department of Radiology, Suite 4200 Gibbon Building, Jefferson Medical College and Thomas Jefferson University Hospital, 111 South 11th Street, Philadelphia, Pennsylvania 19107, USA. geoffrrey.gardiner@mail.tju.edu
J Vasc Interv Radiol ; 12(12): 1389-93, 2001 Dec.
Article em En | MEDLINE | ID: mdl-11742011
ABSTRACT

PURPOSE:

Elastic recoil of the arterial wall has been shown to be responsible for a significant loss of luminal area after balloon angioplasty in the coronary arteries, but it has not been well studied in the peripheral arteries. Because elastic recoil depends on the presence of elastin in the arterial wall, and the amount of elastin varies by artery and proximity to the aorta, the importance of this response to angioplasty may be different in peripheral arteries. The purpose of this study is to document the degree of elastic recoil in the iliac arteries, and analyze variables that might influence the results. MATERIALS AND

METHODS:

A series of 19 patients with 25 iliac artery stenoses underwent balloon angioplasty followed by placement of a Palmaz stent with the same-sized angioplasty balloon. The minimum luminal diameter of the lesion was measured before treatment, immediately after balloon angioplasty, and again after stent placement. The arterial diameter after stent placement was defined as the diameter of the inflated balloon. The degree of recoil was correlated with nine variables patient age and sex, lesion location and length, lesion severity (as percent stenosis), the balloonartery ratio, and three factors related to lesion morphology--complex versus simple, eccentric versus concentric, and calcified versus noncalcified.

RESULTS:

Elastic recoil averaged 36% +/- 11% and ranged from 19% to 54% in this series of patients. The only variable that significantly influenced the degree of elastic recoil was the balloonartery ratio (P =.039), which was directly related.

CONCLUSION:

Elastic recoil is a significant limitation of balloon angioplasty in the iliac arteries. This study illustrates the importance of techniques that limit recoil, such as vascular stents, in angioplasty of the iliac arteries.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Arteriopatias Oclusivas / Angioplastia com Balão / Artéria Ilíaca Tipo de estudo: Diagnostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2001 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Arteriopatias Oclusivas / Angioplastia com Balão / Artéria Ilíaca Tipo de estudo: Diagnostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2001 Tipo de documento: Article