Your browser doesn't support javascript.
loading
Sirolimus-eluting stents for the treatment of obstructive superficial femoral artery disease: six-month results.
Duda, Stephan H; Pusich, Benjamin; Richter, Goetz; Landwehr, Peter; Oliva, Vincent L; Tielbeek, Alexander; Wiesinger, Benjamin; Hak, Jan Bart; Tielemans, Hans; Ziemer, Gerhard; Cristea, Ecatarina; Lansky, Alexandra; Bérégi, Jean P.
Afiliação
  • Duda SH; Department of Diagnostic Radiology, University of Tübingen, Tübingen, Germany. stephan.duda@med.uni-tuebingen.de
Circulation ; 106(12): 1505-9, 2002 Sep 17.
Article em En | MEDLINE | ID: mdl-12234956
ABSTRACT

BACKGROUND:

Stent implantation for obstructive femoropopliteal artery disease has been associated with poor long-term outcomes. This study evaluated the effectiveness of shape memory alloy recoverable technology (SMART) nitinol self-expanding stents coated with a polymer impregnated with sirolimus (rapamycin) versus uncoated SMART stents in superficial femoral artery obstructions. METHODS AND

RESULTS:

Thirty-six patients were recruited for this double-blind, randomized, prospective trial. All patients had chronic limb ischemia and femoral artery occlusions (57%) or stenoses (average lesion length, 85+/-57 mm). Patients were eligible for randomization after successful guidewire passage across the lesion. Eighteen patients received sirolimus-eluting SMART stents and 18 patients received uncoated SMART stents. The primary end point of the study was the in-stent mean percent diameter stenosis, as measured by quantitative angiography at 6 months. The in-stent mean percent diameter stenosis was 22.6% in the sirolimus-eluting stent group versus 30.9% in the uncoated stent group (P=0.294). The in-stent mean lumen diameter was significantly larger in the sirolimus-eluting stent group (4.95 mm versus 4.31 mm in the uncoated stent group; P=0.047). No serious adverse events (death or prolonged hospitalization) were reported.

CONCLUSIONS:

The use of sirolimus-eluting SMART stents for superficial femoral artery occlusion is feasible, with a trend toward reducing late loss compared with uncoated stents. The coated stent also proved to be safe and was not associated with any serious adverse events.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Arteriopatias Oclusivas / Stents / Sirolimo / Artéria Femoral / Imunossupressores Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2002 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Arteriopatias Oclusivas / Stents / Sirolimo / Artéria Femoral / Imunossupressores Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2002 Tipo de documento: Article