Results of replacement of cardiac valves by homologous dura mater valves.
Chest ; 67(6): 706-10, 1975 Jun.
Article em En | MEDLINE | ID: mdl-123848
ABSTRACT
Homologous dura mater valve was employed in a series of 533 patients in the period between January 1971 and May 1974. The dura mater was sterilized and preserved in 98 percent glycerol solution at room temperature. Important data were the following (1) no significant pressure gradient through the vale at rest; (2) no bacterial endocarditis; (3) two cases of fungal endocarditis; (4) no degeneration or retraction of the leaflets; (5) no thrombus formation in the valve; and (6) no anticoagulants were used in this series.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Próteses Valvulares Cardíacas / Dura-Máter Tipo de estudo: Diagnostic_studies / Etiology_studies / Evaluation_studies Limite: Humans Idioma: En Ano de publicação: 1975 Tipo de documento: Article
Buscar no Google