Your browser doesn't support javascript.
loading
A novel vacuum device for extremity immobilisation during digital angiography: preliminary clinical experiences.
Bale, R J; Lottersberger, C; Vogele, M; Prassl, A; Czermak, B; Dessl, A; Sweeney, R A; Waldenberger, P; Jaschke, W.
Afiliação
  • Bale RJ; Department of Radiology, Interdisciplinary Stereotactic Intervention- and Planning Laboratory (SIPLab), University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria. reto.bale@uibk.ac.at
Eur Radiol ; 12(12): 2890-4, 2002 Dec.
Article em En | MEDLINE | ID: mdl-12439566
ABSTRACT
Our objective was to develop and evaluate a non-invasive device for rigid immobilisation during extremity angiography. The patented BodyFix immobilisation device (Medical Intelligence, Schwabmünchen, Germany) consists of a vacuum pump connected to special cushions and a plastic foil that covers the body part to be immobilised. First, the patient's extremity is covered by a thin plastic bag and then wrapped in one of the cushions, placed on the top of the therapy couch, and covered with the plastic foil. The air is evacuated from the cushion under the covering foil by the vacuum pump, resulting a hardening of the cushion and thus immobilisation of the patient's extremity. The rigid immobilisation resulted in a complete absence of motion artefacts in the majority of patients. No pixeling of the images was required in any of the 100 patients vs 32% in the control group. Repetition of series could be avoided in all cases and a substantial increase in the quality of the images was obtained. Setup of the device takes an additional 1-2 min. Vacuum immobilisation allows for comfortable, effective immobilisation during digital subtraction angiography, eliminating motion artefacts. This device has become an indispensable tool in daily clinical routine at our department.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dispositivos de Fixação Ortopédica / Vácuo / Intensificação de Imagem Radiográfica / Extremidade Inferior / Imobilização Tipo de estudo: Etiology_studies / Evaluation_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2002 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dispositivos de Fixação Ortopédica / Vácuo / Intensificação de Imagem Radiográfica / Extremidade Inferior / Imobilização Tipo de estudo: Etiology_studies / Evaluation_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2002 Tipo de documento: Article