Your browser doesn't support javascript.
loading
Fluid modeling of the laser ablation depth as a function of the pulse duration for conductors.
Laville, S; Vidal, F; Johnston, T W; Barthélemy, O; Chaker, M; Drogoff, B Le; Margot, J; Sabsabi, M.
Afiliação
  • Laville S; Institut National de la Recherche Scientifique, Varennes, Québec, J3X 1S2 Canada.
Phys Rev E Stat Nonlin Soft Matter Phys ; 66(6 Pt 2): 066415, 2002 Dec.
Article em En | MEDLINE | ID: mdl-12513420
ABSTRACT
Laser ablation of an aluminum target as a function of the pulse duration, for fluences up to 30 J/cm(2) and a wavelength of 0.8 microm, is investigated by means of a fluid code. For a given fluence, the ablation depth shows a minimum for a pulse duration of approximately 10 ps between a maximum obtained for pulses shorter than approximately 1 ps and a lower maximum obtained for pulses in the nanosecond range, in qualitative agreement with published experimental results. The decrease in ablation depth with increase in pulse duration observed between 1 and 10 ps results from the reduced temperature rise near the surface due to increased inward heat transport. The increase in the ablation depth above approximately 10 ps is due to the increase in electron density gradient length while the laser pulse intensity is close to maximum, which thus enables the plasma to absorb more of the laser pulse energy for increased ablation.
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Qualitative_research Idioma: En Ano de publicação: 2002 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Qualitative_research Idioma: En Ano de publicação: 2002 Tipo de documento: Article