Assessment of myocardial perfusion with intravenous contrast echocardiography: comparison with (99) Tc-tetrofosmin single photon emission computed tomography and dobutamine echocardiography.
Echocardiography ; 20(1): 37-45, 2003 Jan.
Article em En | MEDLINE | ID: mdl-12848696
ABSTRACT
The aim of the study was to evaluate the accuracy of intermittent, harmonic power Doppler (HPD) during intravenous Levovist infusion in identifying myocardial perfusion abnormalities in patients with recent infarction. Fifty-five patients with first acute myocardial infarction, successfully treated by primary PTCA, were studied after 1 month by myocardial contrast echocardiography (MCE), 99mTc tetrofosmin single photon emission computed tomography (SPECT), and low dose dobutamine echocardiography (DE). Scoring myocardial perfusion as normal, moderately, or severely reduced; MCE and SPECT were in agreement in 71% of segments(k = 0.414). Discordance was mainly due to ventricular walls with normal enhancement by MCE and moderate perfusion abnormalities by SPECT. Scoring perfusion as present or absent, the agreement significantly improved up to 86% (k = 0.59). Sensitivity and specificity of HPD for identifying SPECT perfusion defects were 63% and 93%, respectively. The agreement between MCE and SPECT was higher(85%, k = 0.627)in patients with anterior infarction. An improvement in regional contractile function was noted after dobutamine in 79 dysfunctional segments. A normal perfusion or a moderate perfusion defect by MCE were detected in 71 of 79 of these segments, while a severe perfusion defect was observed in 59 of 85 ventricular segments without dobutamine-induced wall-motion improvement. Sensitivity and specificity by HPD in detecting segments with contractile reserve were 90% and 69%, respectively. Thus, intermittent HPD during Levovist infusion allows myocardial perfusion abnormalities to be detected in patients with recent infarction. This method has a limited sensitivity but a high specificity in detecting SPECT perfusion defects, and a good sensitivity but a limited specificity in detecting contractile reserve.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos Organofosforados / Polissacarídeos / Ecocardiografia / Compostos de Organotecnécio / Tomografia Computadorizada de Emissão de Fóton Único / Circulação Coronária / Coração Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2003 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos Organofosforados / Polissacarídeos / Ecocardiografia / Compostos de Organotecnécio / Tomografia Computadorizada de Emissão de Fóton Único / Circulação Coronária / Coração Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2003 Tipo de documento: Article