Your browser doesn't support javascript.
loading
Comparison between human pharmacokinetics and imaging properties of two conjugation methods for 99mTc-annexin A5.
Boersma, H H; Liem, I H; Kemerink, G J; Thimister, P W L; Hofstra, L; Stolk, L M L; van Heerde, W L; Pakbiers, M-T W; Janssen, D; Beysens, A J; Reutelingsperger, C P M; Heidendal, G A K.
Afiliação
  • Boersma HH; Department of Nuclear Medicine, University Hospital Maastricht, P.O. Box 5800, NL-6202 AZ Maastricht, The Netherlands.
Br J Radiol ; 76(908): 553-60, 2003 Aug.
Article em En | MEDLINE | ID: mdl-12893698
Annexin A5 (AnxA5) is a protein with high affinity for phosphatidyl serine, a phospholipid exposed on the cell surface during apoptosis. This phenomenon has been used for determination of cell death after myocardial infarction. To evaluate the potential of (99m)Tc-AnxA5 for in vivo scintigraphy of apoptotic cells, the pharmacokinetics and imaging properties of two radiopharmaceuticals, (99m)Tc-(n-1-imino-4-mercaptobutyl)-AnxA5 (I-AnxA5) and (99m)Tc-(4,5-bis(thioacetamido)pentanoyl)-AnxA5 (B-AnxA5), were studied. I-AnxA5 was administered intravenously to seven patients and one healthy volunteer, and B-AnxA5 was administered to 12 patients. All patients in the pharmacokinetic study had myocardial disease. Additionally, imaging was performed in a patient with acute myocardial infarction, as well as in three patients with different malignancies. The plasma concentration, excretion and biodistribution of (99m)Tc-AnxA5 were measured, as well as levels of AnxA5 antigen. The kinetic data of both radiopharmaceuticals in plasma fitted a two-compartment model. Both preparations had similar half-lives, but a different distribution over the two compartments. Plasma levels of AnxA5 antigen showed a broad variation. Both radiopharmaceuticals accumulated in the kidney, liver and gut. B-AnxA5 was excreted significantly faster than I-AnxA5. Both compounds can be used for imaging of the head/neck region, the thorax and the extremities. B-AnxA5 has a faster clearance and a lower radiation dose. Imaging of apoptosis in the abdomen will be difficult with both radiopharmaceuticals, and especially with B-AnxA5 because of its faster appearance in the gut.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos de Organotecnécio / Anexina A5 / Compostos Radiofarmacêuticos / Cardiomiopatias Limite: Adult / Aged / Aged80 / Humans / Middle aged Idioma: En Ano de publicação: 2003 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos de Organotecnécio / Anexina A5 / Compostos Radiofarmacêuticos / Cardiomiopatias Limite: Adult / Aged / Aged80 / Humans / Middle aged Idioma: En Ano de publicação: 2003 Tipo de documento: Article