Your browser doesn't support javascript.
loading
Flow rate calibration II: a clinical evaluation study using PanLeucoGating as a single-platform protocol.
Storie, Ian; Sawle, Alex; Whitby, Liam; Goodfellow, Karen; Granger, Vivian; Reilly, John T; Barnett, David.
Afiliação
  • Storie I; UK NEQAS for Leucocyte Immunophenotyping, Royal Hallamshire Hospital, Sheffield, United Kingdom.
Cytometry B Clin Cytom ; 55(1): 8-13, 2003 Sep.
Article em En | MEDLINE | ID: mdl-12949954
ABSTRACT

BACKGROUND:

CD4(+) T-lymphocyte enumeration is vital for monitoring disease progression in individuals positive for the human immunodeficiency virus (HIV), and as a result, there is a need to develop cost-effective protocols that provide accuracy, precision, and affordability. Recently, PanLeucoGating has been shown to fulfill these requirements; however, although comparable to state-of-the-art single-platform protocols (SP), there is still a requirement for an accurate total white cell count. To overcome this limitation, we recently developed a flow-rate based calibration method that enables the PanLeucoGating protocol to be used as a SP approach, and in this study show that this approach can be used for CD4(+) T-lymphocyte enumeration.

METHODS:

A total of 113 HIV samples were analyzed using three protocols (a) state-of-the art SP bead-based method (MultiSet; predicate protocol), (b) PanLeucoGating protocol used as a dual-platform (DP) approach, and (c) the newly developed flow rate-based SP approach. We demonstrate that flow rate calibration can be achieved easily and that the method is highly comparable to the state-of-the-art SP method.

RESULTS:

A high correlation was observed between the predicate protocol and the SP PanLeucoGating approach over the whole range of CD4 counts tested (r(2) = 0.9928; bias 8 cells/microl), including the clinically relevant range (e.g., 0-200 CD4 cells/microl; bias 0 cells/microl). For batched samples, the cost of providing a CD4(+) T-lymphocyte count was reduced to approximately US $1.

CONCLUSIONS:

The SP PanLeucoGating is a cost-effective approach to CD4(+) T-lymphocyte enumeration that maintains accuracy and precision.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Contagem de Linfócito CD4 / Citometria de Fluxo Tipo de estudo: Diagnostic_studies / Evaluation_studies / Guideline / Prognostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2003 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Contagem de Linfócito CD4 / Citometria de Fluxo Tipo de estudo: Diagnostic_studies / Evaluation_studies / Guideline / Prognostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2003 Tipo de documento: Article