Oxygen availability during orthotopic liver transplantation.
Kostopanagiotou, Georgia; Smyrniotis, Vassilios; Theodoraki, Kassiani; Skalkidis, Yannis; Heaton, Nigel; Potter, Dennis.
Afiliação
  • Kostopanagiotou G; Department of Anesthesiology, Aretaieon Hospital, University of Athens, Greece. boulof@hol.gr
Liver Transpl ; 9(11): 1216-21, 2003 Nov.
Article em En | MEDLINE | ID: mdl-14586884
ABSTRACT
Studies have stressed the role of adequate tissue oxygenation in the light of an optimal patient outcome and allograft viability in liver transplantation. The practice of monitoring conventional hemodynamic parameters during liver transplantation could be complemented by parameters assessing real oxygen availability. In the present prospective study, real arterial available oxygen content (CavlO(2)) and its extraction ratio (O(2)ERavl) were calculated. These parameters include the effect of changes in oxyhemoglobin dissociation curve (ODC; expressed by P(50)) on oxygen availability, under the different circumstances occurring during liver transplantation. Sixteen adult cirrhotic patients were studied during orthotopic liver transplantation with the use of venovenous bypass. Classic hemodynamic measurements using a Swan-Ganz thermodilution catheter and arterial and mixed venous blood gas analysis were performed, and P(50), oxygen delivery index (DO(2 ind)), oxygen consumption index (VO(2 ind)), oxygen extraction ratio (O(2)ER), CavlO(2), and O(2)ERavl were calculated. Statistical analysis was performed using ANOVA for repeated measures and Spearman correlation coefficient matrix among the six variables (DO(2 ind), VO(2 ind), O(2)ER, P(50), CavlO(2), and O(2)ERavl) taken two at a time at every phase. Parameter P(50) changed from 25.98 +/- 1.10 to 23.15 +/- 2.24 (at the end of operation). A leftward shift of the ODC was observed. The results showed positive association between P(50) and CavlO(2) after the removal of the native liver, and a weak and inconsistent relation of DO(2 ind) with any of the other study variables. The intraoperative changes in P(50) values, which represent a shift of the ODC to the left, may reflect a more accurate estimation of O(2) release to the tissues, than the hemoglobin, Pao(2) and Sao(2) alone. Besides conventional hemodynamic parameters, P(50), which includes the effect of alterations in ODC on oxygen availability, could be of value in monitoring the systemic oxygenation during liver transplantation.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oxigênio / Transplante de Fígado Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2003 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oxigênio / Transplante de Fígado Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2003 Tipo de documento: Article